• Title/Summary/Keyword: 소구경화기

Search Result 9, Processing Time 0.025 seconds

Study on the Service Quality of Small Arms using Kano-SERVQUAL Integrated Approach (Kano-SERVQUAL 통합접근법을 이용한 소구경화기의 서비스 품질에 관한 연구)

  • Lee, Ho-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.56-64
    • /
    • 2020
  • Service quality research is being conducted actively to improve customer satisfaction in various fields, but no research has been done on the service quality of small arms in the national defense. To enhance the user satisfaction and quality of small arms, this study aimed to derive the main quality attributes, measure the current level of satisfaction, and explore the elements requiring improvement. For this, a questionnaire survey based on the Kano model and SERVQUAL model was conducted on the identified service quality factors through discussions of experts involved in the production, quality assurance, and operation. All service quality factors were classified as one-dimensional elements, and an analysis of the Kano-SERVQUAL integrated approach showed that the user's expectation and dissatisfaction coefficient had a strong positive correlation with a 1% significance level, and user's perception value and satisfaction coefficient had a negative correlation with the 1% significance level. Using the Kano-SERVQUAL integrated approach, the priority service quality attributes for small arms requiring improvement among the many areas of service quality could be identified. Overall, it is expected that service-quality-level measurements can be used to improve the quality level of munitions as well as user satisfaction.

A Study on the Prediction of the Remaining Life of the Barrel in Small Arms using Analyzing Dispersion (분산도 분석에 의한 총열 잔여수명 예측에 관한 연구)

  • Kim, Hyun-Jun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.139-145
    • /
    • 2009
  • This paper includes that there is the way to make the prediction of the remaining life of the barrel in small arms using analyzing dispersion. There are some ways to know the period to change the barrel such as the method of detecting the inner surface directly or inspecting the scratch using the optical sensor. However, it is a more easy way to check the dispersion for soldiers and the directors in a logistics command. Therefore, this study is conducted to focusing on the relation between firing round and dispersion. And the simple equation experimentally derives from pre-tests and analyses. Also, this equation is confirmed through the firing tests during the period of developing K11. In that sense, it can be easily applied to know the period of changing the barrel of small arms in the field army.

A CASE STUDY ON THE EFFECT OF NITRIDING FOR CHROME-PLATING LOSS OF SMALL ARMS BARREL (소구경화기 총열의 크롬도금 손실방지를 위한 질화 영향 사례연구)

  • Shin, JW;Shin, TS;Choi, SY;Chung, SH;Kim, BK;Kwon, HR
    • Journal of Korean Society for Quality Management
    • /
    • v.45 no.3
    • /
    • pp.327-333
    • /
    • 2017
  • Purpose: The purpose of this study is to research to protect to loss of chrome-plating of small arms barrel on high temperature in order to extend its life expectency. Methods: The reason why chrome-plating dropped out is main material is weak from heat. Therfore, to make barrel of small arms have higher heat-resistant property, nitriding for barrel before chrome-plating is needed and test of that barrel was handled to improve it. Results: Nitriding before chrome-plating is useful to protect to chrome-plating loss on high temperature. Conclusion: To protect loss of chome-plating of small arms barrel during on firing, pre-nitriding on barrel is effective finally it leads to extend to barrel's life expectency.

Study of Prediction of Reliability of Barrel in Small Arms by Dispersion Anlaysis (분산도 분석기법을 통한 총열 신뢰성 예측에 관한 연구)

  • Kim, Hyun Jun;Chae, Je Wook;Choe, Eui Jung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.2
    • /
    • pp.227-232
    • /
    • 2013
  • This study proposes a method for predicting the reliability of the barrel in small arms by analyzing the dispersion. The periodicity with which the barrel needs to be changed can be determined by detecting the inner surface directly or by inspecting scratches inside the barrel using an optical sensor. However, soldiers and directors in the logistics command need a more easy way to check the periodicity of barrel. Therefore, this study focuses on the relation between the firing round and the dispersion. A simple equation can be experimentally derived from pre-tests and analyses. This equation is confirmed through firing tests. In this sense, it can be easily applied to determine the periodicity with which the barrel of small arms needs to be changed in the field army.

Optimization of Inner Nitriding Process for Cr-Mo-V Steel of Small Arms Barrel by using Taguchi Experimental Design Method (다구찌 실험계획법을 이용한 소구경화기 총열 내부용 Cr-Mo-V강의 질화공정 최적화)

  • Kwon, Hyuk-Rin;Kim, Dong-Eun;Son, Hyung-Dong;Shin, Jea-Won;Park, Jae-Ha;Kang, Myung-Chang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.3
    • /
    • pp.148-154
    • /
    • 2018
  • When shooting small arms, the inner surface temperature is heated up to about $700{\sim}1,000^{\circ}C$ by the friction of the bullet and the inner wall of the barrel and the combustion of propellant. High-temperature propellant gas and high-speed movement of the bullet cause corrosion of the inner wall, which is noticeable immediately in front of the chamber. In this study, the mechanical properties of Cr-Mo-V steel, which is the base material, were tested using Taguchi experimental design to find the best nitriding treatment conditions. For the nitriding process, the working time, salt bath temperature, and salt concentration were combined as three conditions and placed in the $L_9(3^4)$, orthogonal array table. The thicknesses of the white layer and the nitrogen diffusion layer were measured after nitriding under each condition in a salt bath furnace. Durability was evaluated by measuring the degree of dispersion through actual shooting because it was difficult to evaluate the mechanical properties of the cylinder inner structure. As a result, it was confirmed that the durability was optimal at $565^{\circ}C$, 1 hour, 0.5%. These optimal conditions were selected by the statistical analysis of the Minitab program(ver.17).

Effects of light direction and exposure times of plasma arc light on shear bond strength of metal brackets (Plasma arc light를 이용한 금속 브라켓의 부착시 광조사 방향과 중합시간이 전단결합강도에 미치는 영향)

  • Roh, Sang-Jeong;Lee, Hyun-Jung;Jeon, Young-Mi;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.34 no.5 s.106
    • /
    • pp.429-438
    • /
    • 2004
  • The purpose of this study was to compare the effects of different light direction exposure times and setting times when using plasma arc light on shear bond strength of metal brackets. 240 extracted human premolars were randomly assigned to one of 16 groups Standardized brackets were bonded to enamel using different light curing units (Plasma arc light and Halogen light), exposure times (Plasma arc light 2. 4, 6 seconds and Halogen light 20 seconds). and light directions [Vertical direction [V] and Oblique direction [O]). 8 groups were tested after 5 minutes and the remaining 8 groups after 24 hours. The metal brackets were bonded with Transbond XT. Shear bond strength was measured by a universal testing machine. The results were as fellows: There were as differences between the shear bond strengths of the Vertical groups (V) and Oblique groups (O). regardless of exposure times and types of light curing units (p>0.05). The shear bond strength of the group with 2 seconds of plasma light were significantly lower than other exposure time groups (P<0.05). The shear bond strength tested after 5 minutes was lower than after 24 hours (p<0.05) The Adhesive Remment Index (ARI) score showed no statistically significant difference among the different groups. The results of this study suggested that the light direction of plasma arc light had no influence on the shear bond strength of metal brackets to enamel. and exposure times more than 4 seconds produced shear bond strengths similar to those Produced with a conventional halogen curing light.

Animal Experiments on an Antithrombogenic Small-Caliber Vascular Prostheses and Vascualr Patch : Observation in Canine Models (항혈전성 소구경 인조 혈관 및 봉합편에 대한 동물 실험)

  • 김수철;김원곤;유세영
    • Journal of Chest Surgery
    • /
    • v.36 no.2
    • /
    • pp.63-72
    • /
    • 2003
  • Although a variety of synthetic vascular grafts are available in modern vascular surgery, no ideal prosthesis ha,4 yet been developed. Small-caliber vascular grafts with low flow, as used in the lower extremity, continue to become thrombosed at unacceptable rates. We have developed and evaluated the new antithrombogenic blood contacting surfaces in canine model. Material and Method: Two now antithrombogenic blood contacting surfaces(Polyvinylalcohol -Polyurethane(PVA-PU) blend and natural Graphite-polyurethane(G-PU) blend) have been developed and evaluated in canine model, using vascular grafts and patches. The luminal surfaces of the test vascular grafts(5 mm ID) were fabricated by dipping a glass rod in PVA-PU blend solution(50 % PVA) using phase separation method. Mongrel dogs of either sex weighing 18-22 kg were anesthetized by endotracheal intubation using halothane and their lungs were ventilated with a volume-cycled ventilator, Maintenance anesthesia with 0.5-1.0% halothane and supplemental oxygen was used. Two pairs were used for comparison in the bilateral femoral arteries for both vascular grafts(PVA-PU vs. PU) and vascular patches(G-PU vs. PU). Bilateral groin incisions were made and the arteries were exposed and clamped. After an excision of 1 cm of the artery between clamps, a grail of 2.5 cm in length was implanted end-to-end using 6-0 polypropylene suture. The vascular patch was implanted as a form of on-lay patch. Animals were sacrificed at 1, 2, 4, 6, 8 and 16 weeks for vascular grafts and 1, 2. 4 and 6 weeks for vascular patches. Result The vascular grafts of PVA-PU blends showed patent lumina in the 2 and 16 weeks animals, while those of PU showed a patent lumen in 2 weeks animal. PVA-PU graft of 16 weeks showed a fairly clean luminal surface. A light microscopic finding of this graft demonstrated good tissue infiltration through porosity, The animals with vascular patches showed patent arteries in both groups except 2 weeks animal. Scanning electron microscopy of the luminal surfaces of G-PU patches in 4 and 6 weeks animals showed endothelial cell covering with microvilli. PU patches showed qualitatively less endothelial cell covering. Conclusion: In conclusion, PVA-PU and G-PU blends can be a promising blood contacting surfaces for application in a synthetic vascualr graft. However, further animal study is needed to determine the real long-term effects of these methods of surface modifications.