• Title/Summary/Keyword: 센서 감도

Search Result 878, Processing Time 0.029 seconds

50-GHz AWG Interrogation of a Multiple-FBG Temperature Sensor (50-GHz AWG를 이용한 다중 광섬유격자 브래그 파장 계측)

  • Moon, HyungMyung;Kwak, SeungChan;Kim, JinBong;Yim, Ju-Wan;Park, Dong-Young;Im, Kiegon
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.6
    • /
    • pp.226-229
    • /
    • 2019
  • We investigated an interrogation system for fiber Bragg gratings by using a 50-GHz 96-channel array waveguide grating. Linearity of the sensitivity (the wavelength shift in response to the change in strain or temperature) is achieved for a Bragg grating of sufficiently wide bandwidth. The present wavelength-monitoring system could measure the change in Bragg wavelength with a resolution of 0.01 nm, at intervals of 10 seconds. When this interrogation system was used for a linear array of 12 acrylaterecoated fiber gratings, the wavelength sensitivity changed from 0.018 nm/℃ to 0.01 nm/℃ when the operating temperature changed from -25℃ to 85℃.

A Study on the Physical Properties of Impurity Doped $MgB_4O_7$ Porsphors (불순물을 첨가한 $MgB_4O_7$ 열형광체의 물리적 특성에 관한 연구)

  • Kim, Young-Kook;Sohn, In-Ho;Chae, Kun-Sik;Lee, Su-Dae;Sul, Chung-Sik;Noh, Kyong-Suk;Song, Jae-Heung;Lee, Sang-Yun;Doh, Sih-Hong
    • Korean Journal of Materials Research
    • /
    • v.8 no.2
    • /
    • pp.173-178
    • /
    • 1998
  • $MgB_4O_7$: Tb, Tm, Dy, La, Ho and Nd phosphors have been prepared by sintering around $580^{\circ}C$ for 2 hours followed by flowing Ar gas. Activation energy and kinetic order of main peak of glow curve were studied by two methods peak shape method and initial rise method. By these methods, the estimated activation energies were $0.76\pm0.02eV$(Tb doped), $0.94\pm0.03eV$(Tm doped), $0.72\pm0.02eV$(Dy doped), respectively. The TL phosphors prepared in this work may be utilized to radiation sensor elements becaue of their high sensitivity to low energy X-ray.

  • PDF

A study on the development of constant temperature hot wire type air flow meter for automobiles (자동차용 정온도 열선식 공기유량계의 개발에 관한 연구)

  • 조성권;유정열;고상근;김동성
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.12
    • /
    • pp.2407-2414
    • /
    • 1992
  • Constant temperature hot wire air flow meter for automobiles requires temperature compensation system because hot wire output signal is sensitive to ambient temperature variations as well as fluid velocity. The objectives of the present study are to design an air flow meter circuit which is capable of compensating the hot wire output signal for ambient temperature variations and to investigate the mechanism of such temperature compensation. This circuit is composed of platinum hot wire, platinum resistor, two variable resistors, a constant resistor and a DC-amplifier. In particular, by simply replacing a constant resistor in one of the bridge arms of the conventional circuit with platinum resistor and a variable resistor for the purpose of temperature compensation, the deviation of output signal with respect to ambient temperature variations between 27deg. C 70deg. C could be reduced to less than 2.5% for mass flow rate and to less than 5% for velocity respectively. The mechanism of temperature compensation against ambient temperature variations was explained by means of measuring the heat transfer coefficient with hot wire temperature variations and analyzing and analyzing conventional empirical equations qualitatively.

Measurement and Analysis of Electric Filed Distributions under 154[kV] Overhead Tranamission Lines (154[KV] 가공송전선로 아래에서 전장분포의 측정과 분석)

  • 이복희;이정기;안창환;이경옥;박동화;곽희로;송진호
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.1
    • /
    • pp.92-98
    • /
    • 1997
  • In this paper, the results of the measurement and analysis of extremely low freqency(ELF) eletric field in the vicinity of 154[kV] overhad transmission lines have been described. The planar-type electric field sensor has been fabricated by three dimensional structure with special consideration of taking the power frequency and lower components. The calibration experiments have been carried out according to the procedures of IEEE recommendation. The electric field measuring system has the frequency bandwidth of 7[Hz] to 2.7[MHz] and the response sensitivity of 0.094[mV/V/m]. Also the practical measurements of electric field under an 154[kV] double corcuit overhead transmission lines have been made abd abalyzed. It was known that the lateral electric field profiles under an 154[kV] double circuit overhead transmission lines show the asymmetrical distributions owing to the environmental metal frame structures and their maximum electric field magnitude is less than 3[kV/m]. It can be concluded that the measured results of the electric fields satisfy with all limits or guide -lines of the various authorized international institutes' recommendations.

  • PDF

도로터널 조명시설의 설계기준

  • 지철근;이진우
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.1
    • /
    • pp.14-23
    • /
    • 1997
  • In this paper, the results of the measurement and analysis of extremely low frequency(ELF) electric field in the vicinity of 154[kV] overhead transmission lines have been described. The planar-type electric field sensor has been fabricated by three dimensional structure with special consideration of taking the power frequency and lower components. The calibration experiments have been carried out according to the procedures of IEEE recommendation. The electric field measuring system has the frequency bandwidth of 7[Hz] to 2.7[MHz] and the response sensitivity of 0.094[mV/V/m]. Also the practical measurements of electric field under an 154[kV] double circuit overhead transmission lines have been made and analyzed. It was known that the lateral electric field profiles under an 154[kV] double circuit overhead transmission lines show the asymmetrical distributions owing to the environmental metal frame structures and their maximum electric field magnitude is less than 3[kV/m]. It can be concluded that the measured results of the electric fields satisfy with all limits or guidelines of the various authorized international institutes' recommendations.

  • PDF

Highly Sensitive Gas Sensors Based on Electrospun Indium Oxide Nanofibers for Indoor Toxic CO and HCHO Gases (전기방사법으로 제작한 In2O3 나노섬유 기반 고감도 실내독성 CO 및 HCHO 가스센서)

  • Im, Dong-Ha;Hwang, Sung-Hwan;Kwon, Se-Hun;Jung, Hyunsung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.12
    • /
    • pp.803-808
    • /
    • 2016
  • In this work, one dimension $In_2O_3$ nanostructures as detecting materials for indoor toxic gases were synthesized by an electrospinning process. The morphology of electrospun $In_2O_3$ nanofibers was controlled by electrolyte composition, applied voltage and working distance between a nozzle and a substrate. The synthesized $In_2O_3$ nanofibers-based paste with/without carbon black additives was prepared for the integration on a sensor device. The integration of $In_2O_3$ sensing materials was conducted by a hand-printing of the paste into the interdigit Au electrodes patterned on Si wafer. Gas sensing properties on CO and HCHO gases were characterized at $300^{\circ}C$. The evaluated sensing properties such as sensitivity, response time and recovery time were improved in $In_2O_3$ nanofiber pastes with carbon black, compared to the paste without carbon black.

Characteristics of Corrosion Damages in Bottom Plate of Above Ground Tank by Acoustic Emission Signal (지상탱크 저판부의 부식손상 평가를 위한 음향방출 신호의 분석)

  • Kim, Sung-Dai;Jung, Woo-Gwang;Lee, Jong-O
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.4
    • /
    • pp.64-72
    • /
    • 2007
  • Under the AE methods, the valid condition analysis and evaluation the leak etc, resulted by the AE signal pattern on the bottom plate of ground tank at full. In next more, the gradient of accumulation amplitude distribution analysis and comparison the energy, count, and duration time that noise of EMI signal were removed. EMI signal showed height-energy, count, and duration time, it also appeared great gradient of accumulation distribution. Then, with the pure remaining AE signals cluster analysis and location. It would possibly assume of damage with corrosion. Total cluster 20 and energy showed between the maximum 11,990 and 8,565 which is much lower than above figure and event number showed from 8 to 5. Even when it difficult to certify damage by open, as it is raised higher height-sensitivity and threshold by 60 dB. It would possibly presume of location source more accurately.

  • PDF

Comparison of Nondestructive Damage Sensitivity of Single Fiber/Epoxy Composites Using Ceramic PZT and Polymeric PVDF Sensors By Micromechanical Technique and Acoustic Emission (Micromechanical 시험법과 AE를 이용한 세라믹 PZT 및 고분자 PVDF 센서에 따른 단섬유 강화 에폭시 복합재료의 비파괴 손상감지능 비교)

  • Jung Jin-Kyu;Kim Dae-Sik;Park Joung-Man;Yoon Dong-Jin
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.04a
    • /
    • pp.135-138
    • /
    • 2004
  • Conventional piezoelectric lead-zirconate-titanate (PZT) senor has high sensitivity, but it is very brittle. Recently polymer films such as polyvinylidene fluoride (PVDF) and poly(vinylidene fluoride­trifluoroethylene) (P(VDF-TrFE)) copolymer have been used as a sensor. The advantages of polymer sensor are the flexibility and mechanical toughness. Simple process and possible several shapes are also additional advantages. Polymer sensor can be directly embedded in a structure. In this study, nondestructive damage sensitivity of single basalt fiber/epoxy composites was investigated with sensor type and thermal damage using AE and oscilloscope. And AE waveform for epoxy matrix with various damage types was compared to each other. The damage sensitivity of two polymer sensors was rather lower than that of PZT sensor. The damage sensitivity of PVDF sensor did not decrease until thermal damage temperature at $80^{\circ}C$ and they decreased significantly at $110^{\circ}C$ However, the damage sensitivity of P(VDF-TrFE) sensor at $110^{\circ}C$ was almost same in no damage sensor. For both top and side impacts, the difference in arrival time increased with increasing internal and surface damage density of epoxy matrix.

  • PDF

A Compensation for Distortion of Stereo-scopic Camera Image Using Neuro-Fuzzy Inference System (뉴로-퍼지 추론시스템을 이용한 입체 영상 카메라의 왜곡 영상 보정)

  • Seo, Han-Seog;Yim, Wha-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.5 no.3
    • /
    • pp.262-268
    • /
    • 2010
  • In this paper, this study restores the distorted image to its original image by compensating for the distortion of image from a fixed-focus camera lens. The various developments and applications of the imaging devices and the image sensors used in a wide range of industries and expanded use, but due to the needs of the small size and light weight of the camera, the distortion from acquiring images of the distorted curvature of the lens tends to affect many. In particular, the three-dimensional imaging camera, each different distortion of left and right lens cause the degradation of three-dimensional sensitivity and left-right image distortion ratio. we approached the way of generalizing the approximate equations to restore each part of left-right camera images to the coordinators of the original images. The adaptive Neuro-Fuzzy Inference System is configured for it. This system is divided from each membership function and is inferred by 1st order Sugeno Fuzzy model. The result is that the compensated images close to the left, right original images. Using low-cost and compact imaging lens by which also determine the exact three-dimensional image-sensing capabilities and will be able to expect from this study.

Magnetic Noise Reduction in MCG Using Spatial Filters (공간 필터를 이용한 심자도 신호에서의 자기잡음 제거)

  • Lee, Hana;Kim, Ki-Wang;Lee, Soo-Yeol;Cho, Min-Hyung;Heo, Young
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.287-292
    • /
    • 2003
  • Even though MCG has many advantages over ECG, MCG signa)s are easily corrupted by external magnetic noises Since multi-channel MCG signals are recorded simultaneously at many spatial positions, it is effective to apply spatial fitters as well as the conventional temporal filters to remove external magnetic noises. The spatial filters can be designed by utilizing the fact that the noise signals caused by external noise sources are more spatially correlated than the original MCG signals. In this paper, we introduce a spatial filtering method for the noise reduction in MCG based on the principal component analysis. Healthy volunteer study results obtained with a 61-channel MCG system are presented.