• Title/Summary/Keyword: 성능시험 기준

Search Result 1,040, Processing Time 0.032 seconds

Applicability of the Tensile Test Performance Evaluation Baseline for Ground Anchors (지반앵커에 대한 인장시험 성능평가 기준선의 적용성 고찰)

  • Kim, Dae Gun;Park, Tae Kwang;Park, Lee Keun;Kim, Tae-Hyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.8
    • /
    • pp.75-84
    • /
    • 2022
  • Currently, tension ground anchors are divided into temporary and permanent based on their purpose and period of use, and their performance evaluations are presented separately. Therefore, applying the current performance evaluation's upper and lower limits to practice seems reasonable. However, because compression ground anchors have been mainly used as permanent, performance evaluation corresponding to permanent is conducted without distinction between temporary and permanent. This evaluation is a strict standard for ground anchors used as temporary, including the removal type. Because of examining the existing performance evaluation for the compression ground anchor, the lower limit can be applied without distinguishing between the temporary and permanent. However, the upper limit should be presented separately for the temporary and permanent. In applying the upper limit, it is necessary to adjust the upper limit of the anchor considering the anchored ground condition (rock or soil), the period of use, and particularly whether the load-displacement curve maintains the elastic state.

A Study on the Analysis of Safety Standard and Evaluation of Safety Performance for the 5 Nm3 /hr Class Alkaline Water Electrolysis System (5 Nm3 /hr급 알카라인 수전해 시스템 안전기준 분석 및 안전성능 평가에 관한 연구)

  • Kim, Ji-Hye;Lee, Eun-Kyung;Kim, Min-Woo;Oh, Gun-Woo;Lee, Jung-Woon;Kim, Woo-Seop
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.65-75
    • /
    • 2018
  • The wind energy produced at night is being discarded because of the excess power generated at night compared to daytime. To solve this problem, In this study, we analyzed the evaluation contents for evaluation of domestic and overseas water electrolysis systems and drew contents for safety performance contents test of the water electrolysis system based on the evaluation contents. The test contents produced the efficiency measurement test, the hydrogen generated pressure test, and the hydrogen purity test. And the safety performance evaluation of the alkaline water electrolysis system of $5Nm^3/hr$ was performed based on the results. As a result, the hydrogen generation was calculated as $5.10Nm^3/hr$ and the stack efficiency was $4.97kWh/Nm^3$. The purity of the hydrogen generated was 99.993% and it was confirmed that it produced high purity hydrogen. I think will help us assess and build safety performance of water electrolysis systems in the future.

Experimental Fatigue Characteristics of Composite Bridge Deck of Hollow Section (중공단면 복합소재 교량 바닥판의 실험적 피로특성 분석)

  • Lee, Sung-Woo;Hong, Kee-Jeung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.19 no.4 s.74
    • /
    • pp.337-345
    • /
    • 2006
  • In this study, to evaluate fatigue characteristics of developed composite bridge deck, compression fatigue test at girder support and flexural fatigue test for the 2.8m-long flexural test model were carried out. For the test specimen, DB 24 truck load was applied up to 2,000,000 cycles. In the compression fatigue test, behavior at deck tube and its bonded connection were evaluated. In the flexural fatigue test, deck behavior at mid-span and girder connection were evaluated.

A Study on Comparison and Analysis of Correlation Test Procedure for a Turbofan and Turboshaft Engine Test Cell (터보팬 및 터보샤프트 엔진 시운전실 Correlation 시험 절차 비교와 분석에 관한 연구)

  • Juhyeon Gwon;Kangmyung Ko
    • Journal of Aerospace System Engineering
    • /
    • v.18 no.1
    • /
    • pp.46-52
    • /
    • 2024
  • Engine test cell should provide controlled test environment to properly verify requirements of engine performance and operational characteristics. However, since test cells cannot be perfectly identical to each other, new test cell requires processes to verify reliability of test results and correct differences through correlation testing using a baseline test cell. This paper studies about what should be considered when correlation testing is performed based on commonalities and differences between turbofan and turboshaft engine. It provides examples of correlation test procedure. In the future, it is expected that this study will help set up a standard that can certify test facility according to engine type.

Wind Tunnel Test Results for 12% Wind Turbine Model(NREL Phase VI) (12% 축소형 풍력터빈 풍동시험 결과 NREL Phase VI 모델)

  • Cho, Tae-Hwan;Kim, Yang-Won;Chang, Byeong-Hee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.245-248
    • /
    • 2006
  • 풍력터빈 풍동시험의 경우 모델 축소에 의한 레이놀즈 수 감소가 ?V력터빈 성능에 미치는 영향이 적절히 고려되어야 한다. 본 연구를 통해 수치해석과 축소모델 풍동시험을 통해 모델 축소효과를 파악하여 이를 적절히 보상하는 기법을 개발하고자 한다. 이를 위해 풍력터빈 형상 및 실물모델 시험데이터가 공개되어 있는 NREL Phase VI 모델을 표준모델로 선정하여 수치해석 및 풍동시험을 수행하였다. 풍동시험은 KARI LSWT에서 2006. 10에 수행되었으며, 블레이드 끝단 속도를 실물 모델과 일치시켰으며 시험부 유속은 $0{\sim}25m/s$, 블레이드 설치각은 3도 조건을 기준조건으로 사용하였다. 축소모델 시험결과 최대토크는 약 10% 정도 감소현상을 보이고 있다.

  • PDF

KARI LSWT Wind Tunnel Test for Wind Turbine (NREL Phase VI 12% Model) (KARI LSWT 표준풍력터빈 풍동시험 : NREL Phase VI 12% 모델)

  • Cho, Tae-Hwan;Kim, Yang-Won;Chang, Byeong-Hee
    • New & Renewable Energy
    • /
    • v.2 no.4 s.8
    • /
    • pp.12-18
    • /
    • 2006
  • 풍력터빈 풍동시험의 경우 모델 축소에 의한 레이놀즈 수 감소가 풍력터빈 성능에 미치는 영향이 적절히 고려되어야 한다. 본 연구를 통해 수치해석과 축소모델 풍동시험을 통해 모델 축소효과를 파악하여 이를 적절히 보상하는 기법을 개발하고자 한다. 이를 위해 풍력터빈 형상 및 실물모델 시험데이터가 공개되어 있는 NREL Phase VI 모델을 표준모델로 선정하여 수치해석 및 풍동시험을 수행하였다. 풍동시험은 KARI LSWT에서 2006. 10에 수행되었으며, 블레이드 끝단 속도를 실물 모델과 일치시켰으며 시험부 유속은 0$\sim$25m/s, 블레이드 설치각은 3도 조건을 기준조건으로 사용하였다. 축소모델 시험결과 최대토크는 약 10% 정도 감소현상을 보이고 있다.

  • PDF

A Study on Establishment of Evaluation Criteria for Anti-Virus Performance Test (Anti-Virus 성능 시험을 위한 평가 기준 수립 연구)

  • Jeongho Lee;Kangsik Shin;Youngrak Ryu;Dong-Jae Jung;Ho-Mook Cho
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.33 no.5
    • /
    • pp.847-859
    • /
    • 2023
  • With the recent increase in damage caused by malcious codes using software vulnerabilities in Korea, it is essential to install anti-virus to prevent malicious codes, However, it is not easy for general users to know which anti-virus product has good performance or whether it is suitable for their environment. There are many institutions that provide information on anti-virus performance outside of korea, and these institutions have established their own test environments and test evaluation items, but they do not disclose detailed test environment information, detailed test evaluation items, and results. In addition, existing quality evaluation studies are not suitable for the evaluating the latest anti-virus products because there are many evaluation criteria that do not meet anti-virus product evaluation. Therefore, this paper establishes detailed anti-virus evaluation metrics suitable for the latest anti-virus evaluation and applies them to 9 domestic and foreign anti-virus products to verify the functions and performance of anti-viruses.

Performance Evaluation of Softwood Plywood as Structural and Concrete-Form Panels (침엽수 합판의 구조용 및 콘크리트 거푸집용으로서의 성능 평가)

  • Lee, Jun-Jae;Kim, Gwang-Chul;Lee, Guk-Sik
    • Journal of the Korean Wood Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.14-24
    • /
    • 2000
  • In present research, the plywoods made of radiata pine or Japanese larch, the potential softwood species in mass supply, were discussed to examine their feasibility as the structural and concrete form panels through the basic properties test. First, plywood qualities and its nail performance were tested. The performance test for concrete form or structural panel by concentrated and uniformly distributed load were conducted to investigate the possibility as structural material for light frame and concrete constructions. Test results of basic quality such as specific gravity, cupping, bowing, and twisting appeared to satisfy the criteria for structural use. Also, nail performance test results, for roof and wall sheathing panels, nail lateral resistance, nail withdrawal resistance, and nail push head resistance proved to meet the required standard for structural use. The test results on performance as structural panel by concentrated and uniformly distributed load and as concrete form panel showed that these two species could be used for structural sheathing, subfloor, and concrete form panels.

  • PDF

Comparison of acoustics performance measurement and evaluation standard of office space and office acoustics criteria of European countries (사무공간의 음향성능 측정, 평가 방법의 표준화와 유럽 국가들의 음향성능 기준 비교)

  • Jeong-Ho Jeong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.133-142
    • /
    • 2023
  • The office environment is changing according to work types, Information Technology (IT) advancements, and the Coronavirus disease (COVID)-19 situation. In order for office space users to perform their tasks comfortably and efficiently, it is necessary to secure individual privacy as well as easy communication among members. In Korea, the demand for improving the acoustic performance of office spaces is also increasing, but the related performance criteria and guidelines have not been established. In this study, standardization of office space acoustic performance measurement and evaluation methods and European countries' acoustic performance criteria were compared and reviewed. It is proposed to comprehensively review international standardization trends and acoustic performance standards in each country and to establish and utilize criteria for evaluating the acoustic performance and satisfaction of office spaces in Korea through our survey. Considering the international standardization direction and compatibility with communication and Public Address (PA) systems, it is appropriate to establish criteria using the speech transmission index or Speech Transmission Index (STI) application index. This criterion will be highly utilizable and compatible. In addition, since the office furniture industry is interested in improving the acoustic performance of office space, it is necessary to establish a labelling system for speech level reduction of office furniture.

Assessment of Smoke Risk of Combustible Materials in Fire (화재 시 가연성 물질의 연기 위험성 평가)

  • Chung, Yeong-Jin;Jin, Eui
    • Applied Chemistry for Engineering
    • /
    • v.31 no.3
    • /
    • pp.277-283
    • /
    • 2020
  • The smoke hazard assessment of building materials focusing on smoke performance index-II (SPI-II) and smoke growth index-II (SGI-II) was investigated. The test species used were Japanese cedar, spruce, lauan, and red pine. The smoke characteristics of wood specimen were investigated using a cone calorimeter (ISO 5660-1). SPI-II was measured after the combustion reaction increased by 1.31~2.15 times based on red pine. The fire risk by SPI-II increased in the order of spruce, lauan, Japanese ceda, and red pine. SGI-II increased by 1.18~2.55 times compared to that of Japnese ceda. The fire risk caused by SGI-II increased in the order of Japanese ceda, spruce, lauan, and red pine. COmean concentrations were ranged from 58 to 133 ppm, which was higher than permissible exposure limits of the occupational safety and health administration (OSHA), 50 ppm. Therefore, woods such as red pine containing various volatile organic substances, were considered to be highly smoke hazardous due to low SPI-II and high SGI-II.