• Title/Summary/Keyword: 성과 정보

Search Result 66,319, Processing Time 0.105 seconds

Preliminary Diagnosis of Fishing Ground Environment for Establishing the Management System in Fisheries Resources Protection Area (수산자원보호구역 관리체제 구축을 위한 어장환경 예비진단)

  • Lee, Dae-In;Park, Dal-Soo;Jeon, Kyeong-Am;Eom, Ki-Hyuk;Park, Jong-Soo;Kim, Gui-Young
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.15 no.2
    • /
    • pp.79-89
    • /
    • 2009
  • For preliminary diagnosis on current fishing ground environment and basic information for establishment of effective and rational management policy in fisheries resources protection area, water and sediment quality and changes of total area in the 10 marine protection areas designated for fisheries resources management in Korea were assessed. Results showed that environmental quality in these areas has been degraded by pollution sources, coastal utilization and development stress, etc. The pattern and degree of contamination differed by protection areas, suggesting that it is necessary for optimum environmental management plan considering the regional characteristics. The total designated area of protection areas in 2003 changed by $-22.9{\sim}2.4%$, on average -6.4%, compared with the first year of designation; Wando-Doam Bay showd the highest increase rate (2.4%), and Hansan Bay has the highest decrease rate (-22.9%) Decrease rate of land and sea in total area showd 6.1% and 6.6%. An integrated management of environmental data in protection areas is required for systematic assessment. Therefore, the suitable environmental and information management is needed specifically considering the environment characteristics such as development and utilization conditions of land and sea area Furthermore, bemuse urbanization and industrialization threats the junctions of the protection areas, authorized ministry (MIFAFF) should develope and establish monitoring and management procedures based on the related laws.

  • PDF

Estimation of Near Surface Air Temperature Using MODIS Land Surface Temperature Data and Geostatistics (MODIS 지표면 온도 자료와 지구통계기법을 이용한 지상 기온 추정)

  • Shin, HyuSeok;Chang, Eunmi;Hong, Sungwook
    • Spatial Information Research
    • /
    • v.22 no.1
    • /
    • pp.55-63
    • /
    • 2014
  • Near surface air temperature data which are one of the essential factors in hydrology, meteorology and climatology, have drawn a substantial amount of attention from various academic domains and societies. Meteorological observations, however, have high spatio-temporal constraints with the limits in the number and distribution over the earth surface. To overcome such limits, many studies have sought to estimate the near surface air temperature from satellite image data at a regional or continental scale with simple regression methods. Alternatively, we applied various Kriging methods such as ordinary Kriging, universal Kriging, Cokriging, Regression Kriging in search of an optimal estimation method based on near surface air temperature data observed from automatic weather stations (AWS) in South Korea throughout 2010 (365 days) and MODIS land surface temperature (LST) data (MOD11A1, 365 images). Due to high spatial heterogeneity, auxiliary data have been also analyzed such as land cover, DEM (digital elevation model) to consider factors that can affect near surface air temperature. Prior to the main estimation, we calculated root mean square error (RMSE) of temperature differences from the 365-days LST and AWS data by season and landcover. The results show that the coefficient of variation (CV) of RMSE by season is 0.86, but the equivalent value of CV by landcover is 0.00746. Seasonal differences between LST and AWS data were greater than that those by landcover. Seasonal RMSE was the lowest in winter (3.72). The results from a linear regression analysis for examining the relationship among AWS, LST, and auxiliary data show that the coefficient of determination was the highest in winter (0.818) but the lowest in summer (0.078), thereby indicating a significant level of seasonal variation. Based on these results, we utilized a variety of Kriging techniques to estimate the surface temperature. The results of cross-validation in each Kriging model show that the measure of model accuracy was 1.71, 1.71, 1.848, and 1.630 for universal Kriging, ordinary Kriging, cokriging, and regression Kriging, respectively. The estimates from regression Kriging thus proved to be the most accurate among the Kriging methods compared.

The Gains To Bidding Firms' Stock Returns From Merger (기업합병의 성과에 영향을 주는 요인에 대한 실증적 연구)

  • Kim, Yong-Kap
    • Management & Information Systems Review
    • /
    • v.23
    • /
    • pp.41-74
    • /
    • 2007
  • In Korea, corporate merger activities were activated since 1980, and nowadays(particuarly since 1986) the changes in domestic and international economic circumstances have made corporate managers have strong interests in merger. Korea and America have different business environments and it is easily conceivable that there exists many differences in motives, methods, and effects of mergers between the two countries. According to recent studies on takeover bids in America, takeover bids have information effects, tax implications, and co-insurance effects, and the form of payment(cash versus securities), the relative size of target and bidder, the leverage effect, Tobin's q, number of bidders(single versus multiple bidder), the time period (before 1968, 1968-1980, 1981 and later), and the target firm reaction (hostile versus friendly) are important determinants of the magnitude of takeover gains and their distribution between targets and bidders at the announcement of takeover bids. This study examines the theory of takeover bids, the status quo and problems of merger in Korea, and then investigates how the announcement of merger are reflected in common stock returns of bidding firms, finally explores empirically the factors influencing abnormal returns of bidding firms' stock price. The hypotheses of this study are as follows ; Shareholders of bidding firms benefit from mergers. And common stock returns of bidding firms at the announcement of takeover bids, shows significant differences according to the condition of the ratio of target size relative to bidding firm, whether the target being a member of the conglomerate to which bidding firm belongs, whether the target being a listed company, the time period(before 1986, 1986, and later), the number of bidding firm's stock in exchange for a stock of the target, whether the merger being a horizontal and vertical merger or a conglomerate merger, and the ratios of debt to equity capital of target and bidding firm. The data analyzed in this study were drawn from public announcements of proposals to acquire a target firm by means of merger. The sample contains all bidding firms which were listed in the stock market and also engaged in successful mergers in the period 1980 through 1992 for which there are daily stock returns. A merger bid was considered successful if it resulted in a completed merger and the target firm disappeared as a separate entity. The final sample contains 113 acquiring firms. The research hypotheses examined in this study are tested by applying an event-type methodology similar to that described in Dodd and Warner. The ordinary-least-squares coefficients of the market-model regression were estimated over the period t=-135 to t=-16 relative to the date of the proposal's initial announcement, t=0. Daily abnormal common stock returns were calculated for each firm i over the interval t=-15 to t=+15. A daily average abnormal return(AR) for each day t was computed. Average cumulative abnormal returns($CART_{T_1,T_2}$) were also derived by summing the $AR_t's$ over various intervals. The expected values of $AR_t$ and $CART_{T_1,T_2}$ are zero in the absence of abnormal performance. The test statistics of $AR_t$ and $CAR_{T_1,T_2}$ are based on the average standardized abnormal return($ASAR_t$) and the average standardized cumulative abnormal return ($ASCAR_{T_1,T_2}$), respectively. Assuming that the individual abnormal returns are normal and independent across t and across securities, the statistics $Z_t$ and $Z_{T_1,T_2}$ which follow a unit-normal distribution(Dodd and Warner), are used to test the hypotheses that the average standardized abnormal returns and the average cumulative standardized abnormal returns equal zero.

  • PDF

Comparison of Growth Characteristics and Flavonoids Content by Different Cultivation Seasons in Buckwheat Germplasm (메밀 유전자원 재배시기별 생육특성 및 플라보노이드 함량 비교)

  • Hyun, Do Yoon;Rauf, Muhammad;Lee, Sukyeung;Ko, Ho Cheol;Oh, Sejong;Lee, Myung-Chul;Choi, Yu-Mi
    • Korean Journal of Plant Resources
    • /
    • v.31 no.5
    • /
    • pp.489-497
    • /
    • 2018
  • In Korea, common and Tartary buckwheat are cultivated mainly in spring and fall, however the available buckwheat varieties are still very limited. In this study, we have evaluated buckwheat germplasm for agronomic traits and compared flavonoids contents in different cultivation period and collection area. In common buckwheat, the number of days from sowing to flowering was 40 and 31 days and from sowing to maturity took 90 and 69 days in spring and fall cultivation, respectively. The number of nodes and branches were higher in spring cultivation while the hundred seed weight was higher in fall cultivation. The average flavonoids contents in common buckwheat were 0.20 mg/g dry weight (DW) and 0.40 mg/g DW in spring and fall cultivation, respectively. The highest flavonoids content was detected in Jeonnam accessions with 0.29 mg/g DW and 0.43 mg/g DW during spring and fall cultivation, respectively. The flavonoids contents were varied from 1.5 to 2.5 times according to the collection area. These results suggest that the agronomic traits and flavonoids contents were vary depending on the cultivation environment and germplasm collection area. Therefore, it is necessary to select the material by considering the characteristics of the germplasm for breeding of new varieties.

Electronic Structure and Si L2,3-edge X-ray Raman Scattering Spectra for SiO2 Polymorphs: Insights from Quantum Chemical Calculations (양자화학계산을 이용한 SiO2 동질이상의 전자 구조와 Si L2,3-edge X-선 라만 산란 스펙트럼 분석)

  • Kim, Yong-Hyun;Yi, Yoo Soo;Lee, Sung Keun
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.33 no.1
    • /
    • pp.1-10
    • /
    • 2020
  • The atomic structures of silicate liquids at high pressure provide insights into the transport properties including thermal conductivities or elemental partitioning behavior between rocks and magmas in Earth's interior. Whereas the local electronic structure around silicon may vary with the arrangement of the nearby oxygens, the detailed nature of such relationship remains to be established. Here, we explored the atomic origin of the pressure-induced changes in the electronic structure around silicon by calculating the partial electronic density of states and L3-edge X-ray absorption spectra of SiO2 polymorphs. The result showed that the Si PDOS at the conduction band varies with the crystal structure and local atomic environments. Particularly, d-orbital showed the distinct features at 108 and 130 eV upon the changes in the coordination number of Si. Calculated Si XAS spectra showed features due to the s,d-orbitals at the conduction band and varied similarly with those observed in s,d-orbitals upon changes in the crystal structures. The calculated Si XAS spectrum for α-quartz was analogous to the experimental Si XRS spectrum for SiO2 glass, implying the overall similarities in the local atomic environments around the Si. The edge energies at the center of gravity of XAS spectra were closely related to the Si-O distance, thus showing the systematic changes upon densification. Current results suggest that the Si L2,3-edge XRS, sensitive probe of the Si-O distance, would be useful in unveiling the densification mechanism of silicate glasses and melts at high pressure.

Isolation and Characterization of a Novel Flavonoid 3'-Hydroxylase (F3'H) Gene from a Chrysanthemum (Dendranthema grandiflorum) and Its Gamma-ray Irradiated Mutants (감마선 처리에 의한 스프레이형 국화 화색변이체로부터 Flavonoid 3'-Hydroxylase(F3'H) 유전자의 분리 및 특성 구명)

  • Chung, Sung-Jin;Lee, Geung-Joo;Kim, Jin-Baek;Kim, Dong-Sub;Kim, Sang-Hoon;Kang, Si-Yong
    • Horticultural Science & Technology
    • /
    • v.30 no.2
    • /
    • pp.162-170
    • /
    • 2012
  • The objectives of this study were to isolate and the sequence of novel $F3'H$ gene related to an anthocyanin pathway, and to confirm the expression patterns of the gene involved in the flower color variations of chrysanthemum mutants. In this study, we isolated the full-length cDNAs and the genomic DNAs of an $F3'H$ gene from a wild type (WT) chrysanthemum (cv. Argus) and its three color mutants. The sequence analysis revealed a putative open reading frame of 1,527 bp that encodes a polypeptide of 509 amino acids. Sequence homology ranged from 97% to 99% between 'Argus' and its three color mutants. The sequence analysis from the genomic DNA revealed that the chrysanthemum $DgF3'H$ gene consisted of three exons and two introns spanning a 3,830 bp length. The sizes of the gene for three mutants ranged from a shorter size of 3,828 bp to a longer size of 3,838 bp when compared to the size of WT. The total size of the two introns was 2,157 bp for WT, but those for three color mutants ranged from 2,154 bp to 2,159 bp. A result of an RT-PCR analysis indicated that the color variations of the mutants AM1 and AM2 can be partly explained by the structural modification derived from the sequencial changes in the gene caused by gamma ray. A Southern blot analysis revealed that the $DgF3'H$ gene existing as multiple copies in the chrysanthemum genome. A systemic study will be further needed to provide a genetic mechanism responsible for the color mutation and to uncover any involvement of genetic elements for the expression of the $DgF3'H$ gene for the color variation in chrysanthemum.

Comparison of pH, Water Holding Capacity and Color among Meats from Korean Native Chickens

  • Jung, Samooel;Kim, Hyun Joo;Lee, Hyun Jung;Seo, Dong Won;Lee, Jun Heon;Park, Hee Bok;Jo, Cheorun;Nam, Ki Chang
    • Korean Journal of Poultry Science
    • /
    • v.42 no.2
    • /
    • pp.101-108
    • /
    • 2015
  • This study investigated the initial pH measured at 15 min post-mortem, ultimate pH, water holding capacity (WHC), and color of meats obtained from five lines of Korean native chicken (KNC) for the development of breed for high-quality meat. In addition, the effect of sex was examined. In total, 595 $F_1$ progeny (Black [B], Grey-Brown [G], Red-Brown [R], White [W] and Yellow-Brown [Y]) from 70 full-sib families were used. Chickens were slaughtered at 20 wk of age and the measurement traits of all breast and thigh meats from 595 chickens were analyzed. The initial pH at 15 min post-slaughter of the breast and thigh meats was affected by the line and sex of Korean native chicken (P<0.05). However, there was no line and sex effect on ultimate pH and WHC of the breast and thigh meat except that the ultimate pH of thigh meat had line effect. Except for the $L^*$ value of breast meat, the meat color was significantly affected by line and sex (P<0.05). The ultimate pH showed consistently negative correlation with the $L^*$ value and positive correlation with the $a^*$ value in breast and thigh meats. Based on the results, we concluded that the line W in male chickens and the line G and W in female chickens may be good candidates for the selection to develop breed for high-quality meat because these lines showed property of high initial pH or/and ultimate pH.

The Effects of a MR Torso Coil on CT Attenuation Correction for PET (PET/CT 검사에 있어서 MR Torso Coil의 CT 감쇄보정에 대한 영향 평가)

  • Lee, Seung Jae;Bahn, Young Kag;Oh, Shin Hyun;Gang, Cheon-Gu;Lim, Han Sang;Kim, Jae Sam;Lee, Chang Ho;Seo, Soo-Hyun;Park, Yong Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.81-86
    • /
    • 2012
  • Purpose : Combined MR/PET scanners that use the MRI for PET AC face the challenge of absent surface coils in MR images and thus cannot directly account for attenuation in the coils. To make up for the weak point of MR attenuation correction, Three Modality System (PET/CT +MR) were used in Severance hospital. The goal of this work was to investigate the effects of MR Torso Coil on CT attenuation correction for PET. Materials and Methods : PET artifacts were evaluated when the MR Torso Coil was present of CTAC data with changing various kV and mA in uniformity water phantom and 1994 NEMA cylinderical phantom. They evaluated and compared the following two scenarios: (1) The uniform cylinder phantom and the MR Torso Coil scanned and reconstructed using CT-AC; (2) 1994 NEMA cylinderical phantom and the MR Torso Coil scanned and reconstructed using CT-AC. Results : Streak artifacts were present in CT images containing the MR Torso Coil due to metal components. These artifacts persisted after the CT images were converted for PET-AC. CT scans tended to over-estimate the linear attenuation coefficient when the kV and mA is increasing of the metal components when using conventional methods for converting from CT number. Conclusion : The presence of MR coils during PET/CT scanning can cause subtle artifacts and potentially important quantification errors. Alternative CT techniques that mitigate artifacts should be used to improve AC accuracy. When possible, removing segments of an MR coil prior to the PET/CT exam is recommended. Further, MR coils could be redesigned to reduce artifacts by rearranging placement of the most attenuating materials.

  • PDF

Comparison of Effectiveness about Image Quality and Scan Time According to Reconstruction Method in Bone SPECT (영상 재구성 방법에 따른 Bone SPECT 영상의 질과 검사시간에 대한 실효성 비교)

  • Kim, Woo-Hyun;Jung, Woo-Young;Lee, Ju-Young;Ryu, Jae-Kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2009
  • Purpose: Nowadays in the nuclear medicine, many studies and efforts are being made to reduce the scan time, as well as the waiting time to be needed to execute exams after injection of radionuclide medicines. Several methods are being used in clinic, such as developing new radionuclide compounds that enable to be absorbed into target organs more quickly and reducing acquisition scan time by increase the number of Gamma Camera detectors to examine. Each medical equipment manufacturer has improved the imaging process techniques to reduce scan time. In this paper, we tried to analyze the difference of image quality between FBP, 3D OSEM reconstruction methods that commercialized and being clinically applied, and Astonish reconstruction method (A kind of Iterative fast reconstruction method of Philips), also difference of image quality on scan time. Material and Methods: We investigated in 32 patients that examined the Bone SPECT from June to July 2008 at department of nuclear medicine, ASAN Medical Center in Seoul. 40sec/frame and 20sec/frame images were acquired that using Philips‘ PRECEDENCE 16 Gamma Camera and then reconstructed those images by using the Astonish (Philips’ Reconstruction Method), 3D OSEM and FBP methods. The blinded test was performed to the clinical interpreting physicians with all images analyzed by each reconstruction method for qualitative analysis. And we analyzed target to non target ratio by draws lesions as the center of disease for quantitative analysis. At this time, each image was analyzed with same location and size of ROI. Results: In a qualitative analysis, there was no significant difference by acquisition time changes in image quality. In a quantitative analysis, the images reconstructed Astonish method showed good quality due to better sharpness and distinguish sharply between lesions and peripheral lesions. After measuring each mean value and standard deviation value of target to non target ratio with 40 sec/frame and 20sec/frame images, those values are Astonish (40 sec-$13.91{\pm}5.62$ : 20 sec-$13.88{\pm}5.92$), 3D OSEM (40 sec-$10.60{\pm}3.55$ : 20 sec-$10.55{\pm}3.64$), FBP (40 sec-$8.30{\pm}4.44$ : 20 sec-$8.19{\pm}4.20$). We analyzed target to non target ratio from 20 sec and 40 sec images. And we analyzed the result, In Astonish (t=0.16, p=0.872), 3D OSEM (t=0.51, p=0.610), FBP (t=0.73, p=0.469) methods, there was no significant difference statistically by acquisition time change in image quality. But FBP indicates no statistical differences while some images indicate difference between 40 sec/frame and 20 sec/frame images by various factors. Conclusions: In the circumstance, try to find a solution to reduce nuclear medicine scan time, the development of nuclear medicine equipment hardware has decreased while software has marched forward at a relentless. Due to development of computer hardware, the image reconstruction time was reduced and the expanded capacity to restore enables iterative methods that couldn't be performed before due to technical limits. As imaging process technique developed, it reduced scan time and we could observe that image quality keep similar level. While keeping exam quality and reducing scan time can induce the reduction of patient's pain and sensory waiting time, also accessibility of nuclear medicine exam will be improved and it provide better service to patients and clinical physician who order exams. Consequently, those things make the image of department of nuclear medicine be improved. Concurrent Imaging - A new function that setting up each image acquisition parameter and enables to acquire images simultaneously with various parameters to once examine.

  • PDF

Comparison of Lens Dose in accordance with Bismuth shielding and Patient position in Brain perfusion CT (Brain Perfusion CT에서 Bismuth 차폐와 환자의 자세 변화에 따른 수정체 선량 비교 연구)

  • Gang, Eun Bo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.47-52
    • /
    • 2018
  • Brain perfusion CT scanning is often employed usefully in clinical conditions as it accurately and promptly provides information about the perfusion state of patients having acute ischemic stroke with a lot of time constraints and allows them to receive proper treatment. Despite those strengths of it, it also has a serious weakness that Lens may be exposed to a lot of dose of radiation in it. In this study, as a way to reduce the dose of radiation to Lens in brain perfusion CT scanning, this researcher conducted an experiment with Bismuth shielding and change of patients' position. TLD (TLD-100) was placed on both lens using the phantom (PBU-50), and then, in total 4 positions, parallel to IOML, parallel to IOML (Bismuth shielding), parallel to SOML, and parallel to SOML (Bismuth shielding), brain perfusion scanning was done 5 times for each position, and dose to Lens were measured. Also, to examine how the picture quality changed in different positions, 4 areas of interest were designated in 4 spots, and then, CT number and noise changes were measured and compared. According to the results of conducting one-way ANOVA on the doses measured, as the significance probability was found to be 0.000, so there was difference found in the doses of radiation to crystalline lenses. According to the results of Duncan's post-hoc test, with the scanning of being parallel to IOML as the reference, the reduction of 89.16% and 89.66% was observed in the scanning of being parallel to SOML and that of being parallel to SOML (Bismuth shielding) respectively, so the doses to Lens reduced significantly. Next, in the scanning of being parallel to IOML (Bismuth shielding), the reduction of 37.12% was found. According to the results, reduction in the doses of radiation was found the most significantly both in the scanning of being parallel to SOML and that of being parallel to SOML (Bismuth shielding). With the limit of the equivalent dose to Lens as the reference, this researcher conducted comparison with the dose to occupational exposure and dose to Public exposure in the scanning of being parallel to IOML and found 39.47% and 394.73% respectively; however in the scanning of being parallel to SOML (Bismuth shielding), considerable reduction was found as 4.08% and 40.8% respectively. According to the results of evaluation on picture quality, every image was found to meet the evaluative standards of phantom scanning in terms of the measurement of CT numbers and noise. In conclusion, it would be the most useful way to reduce the dose of radiation to Lens to use shields in brain perfusion CT scanning and adjust patients' position so that their lens will not be in the field of radiation.