• Title/Summary/Keyword: 설계순환

Search Result 884, Processing Time 0.041 seconds

Research Background and Plan of Enhanced Geothermal System Project for MW Power Generation in Korea (MW급 EGS 지열발전 상용화 기술개발사업의 추진 배경 및 계획)

  • Yoon, Woon-Sang;Song, Yoon-Ho;Lee, Tae-Jong;Kim, Kwang-Yeom;Min, Ki-Bok;Cho, Yong-Hee;Jeon, Jong-Ug
    • Tunnel and Underground Space
    • /
    • v.21 no.1
    • /
    • pp.11-19
    • /
    • 2011
  • Geothermal energy is believed to be an important source among the renewable energy sources to provide the base load electricity. Although there has been a drastic increase in the use of geothermal heat pump in Korea, there is no geothermal power plant in operation in Korea. Fortunately, the first EGS (Enhanced Geothermal System) Project in Korea has started in Dec 2010. This five year project is divided into two stages; two years for exploration and drilling of 3 km depth to confirm the minimum target temperature of 100 degrees, and another three years composed drilling 5 km doublet, hydraulic stimulation of geothermal reservoir with expected temperature of 180 degrees (40 kg/s) and construction of MW geothermal power plant in the surface. This EGS project would be a landmark effort that invited a consortium of industry, research institutes and university with expertises in the fields of geology, hydrogeology, geophysics, geomechanics and plant engineering.

GIS spatial D/B formation of geothermal data and Distribution of Heat Flow of Korea (한국의 지열자료 GIS 공간 D/B 구축과 지열류량 분포)

  • Kim, Hyoung-Chan;Lee, Young-Min;Park, Jeong-Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.459-460
    • /
    • 2006
  • 현재 남한의 지열류량 측정값으로는 총 363개 지점의 자료가 측정 및 수집되어 있다. 이것은 Mizutani et at. (1970), 장정진 외(1970), 그리고 서정희(1976) 등의 자료, 총 35개의 자료도 추가된 것이다. 1989년 이후부터 측정된 지열류량 자료는 217개 자료이며(임정웅 외, 1989; 임정웅 외, 1996; Lim and Kim, 1997; 염병우 외, 1997), 모두 직접 측정한 것이나, 1989년 이후 보고된 지열류량 자료에 약간의 오류가 있어 이번 연구에서 수정 보완하였다. 또한 과거의 자료 35개 자료는 이미 지열류량 측정치가 논문화 되어 있는 것으로 암석시료는 없다 1989년 이후 2004년까지 자료 217개 2005년도 추가 자료 111개의 지열류량 자료는 암석시료도 있으며, 측정기기가 서로 달라 오차가 있을 수 있어 서로 보정을 해야 할 필요가 있어 시추공 주변 암석을 새로 수집해서 신장비로 다시 측정 보정하였다. 지열류량 D/B 구축은 각 자료의 일련번호, 고유번호 (Sn.), 위경도 좌표 (longitude, lattitude), 암석의 열전도도(thermal conductivity), 지온경사 (thermal gradient), 지열류량 (heat flow)등으로 구성되어 있다. 지열류량 자료 공간 데이터베이스는 점 속성을 가지며 자료형태는 각종 소프트웨어와 호환성이 좋은 shape 파일 형태로 작성하였다. 또만 최근 천부 토양 및 암석 열물성을 이용한 냉난방시스템 즉, Heat Pump System 설계를 위하여 반드시 들어가야 하는 요소인 열확산율, 공극율, 밀도, 비열 등 열물성 특성을 추가하여 GIS 공간 D/B구축하였다. 대륙붕 자료 4개 자료를 제외하고 359개의 지열류량 자료를 이용하여 한반도 남부, 즉 남한의 지열류량 분포도를 작성 분석해 본 결과(그림 1), 우리나라의 지열류량 이상대는 아산만 주변, 보령, 유성, 진안, 울진, 포항, 부산 지역과 포천, 속초, 충주, 수안보 등 지역에서 나타난다 이러한 이상대 주변에는 대개 온천이 발달되어 있었거나 새로 개발되어 있는 곳이다. 온천에 이용하고 있는 시추공의 자료는 배제하였으나 온천이응으로 직접적으로 영향을 받지 않은 시추공의 자료는 사용하였다 이러한 온천 주변 지역이라 하더라도 실제는 온천의 pumping 으로 인한 대류현상으로 주변 일대의 온도를 올려놓았기 때문에 비교적 높은 지열류량 값을 보인다. 한편 한반도 남동부 일대는 이번 추가된 자료에 의해 새로운 지열류량 분포 변화가 나타났다 강원 북부 오색온천지역 부근에서 높은 지열류량 분포를 보이며 또한 우리나라 대단층 중의 하나인 양산단층과 같은 방향으로 발달한 밀양단층, 모량단층, 동래단층 등 주변부로 NNE-SSW 방향의 지열류량 이상대가 발달한다. 이것으로 볼 때 지열류량은 지질구조와 무관하지 않음을 파악할 수 있다. 특히 이러한 단층대 주변은 지열수의 순환이 깊은 심도까지 가능하므로 이러한 대류현상으로 지표부근까지 높은 지온 전달이 되어 나타나는 것으로 판단된다.

  • PDF

The Cooling Effect of Fog Cooling System as Affected by Air Exchange Rate in Natural Ventilation Greenhouse (자연환기 온실의 환기회수에 따른 포그냉방시스템의 냉방효과)

  • 김문기;김기성;권혁진
    • Journal of Bio-Environment Control
    • /
    • v.10 no.1
    • /
    • pp.10-14
    • /
    • 2001
  • The cooling effect of a fog cooling system has a close relationship to air flow and relative humidity in the greenhouse. From the VETH chart for cooling design, a cooling efficiency can be improved by means of increasing the air exchange rate and the amount of sprayed water. In the no shading experimental greenhouse by time control, when average air exchange rate was 0.77 times.min$^{-1}$ and spray water amount was 2,009g, inside temperature of the greenhouse was 31$^{\circ}C$ that was almost close to outside temperature and cooling efficiency was 82%. When average air exchange rate was close to temperature of the greenhouse that was no cooling and 70% shading greenhouse environment. When average air exchange rate was 2.59times.min$^{-1}$ , spray water amount was 2,009g and shading rate was 70%, inside relative humidity of the greenhouse was increased was 2,009 g and shading rate was 70%, inside relative humidity of the greenhouse was increased, but temperature was not decreased. When average air exchange rate was 2.33 times.min$^{-1}$ and spray water amount was 2,009g, inside temperature was 31.4 and at that time maximum wind speed at the air inlet of greenhouse was 1.9m.s$^{-1}$ . Since time controller sprayed amount of constant water at a given interval, some of sprayed water remained not to be evaporated, which increased relative humidity and decreased cooling efficiency. Because the shading screen prevented air flow in the greenhouse, it also caused the evaporation efficiency to be decreased. In order to increase cooling efficiency, it was necessary to study on controling by relative humidity and air circulation in the greenhouse.

  • PDF

Pulsed Laser System of Ultra-scan Way for Uterus Rehabilitation Treatment (자궁 재활치료를 위한 울트라-스캔 방식의 펄스형 레이저시스템)

  • Kim, Whi-Young
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.6
    • /
    • pp.256-265
    • /
    • 2009
  • Laser output becomes output adjustment from 20 w to 100 w consecutively and time of exposure is available adjustment through water plant in 0.01 seconds. Pulse action can intercept laser beam periodically and supermarket pulse 0.1 $\sim$ between 1ms discharge consist and momentary laser output is increased to 5 $\sim$ 10. Specially, that must remove malignancy cell in womb nine escarps in the case of uterine cancer first of all stability of tube output about pulse by weight very, stable soft switching action area is defined without high frequency transformer leakage inductance ($L_1$) increase and additional series inductor insertion to converter the first main circuit securing zero voltage and marks of switching action in this research specially, because circulation current path of inductor ($L_f$) current is intercepted, converter the first main circuit switching component and spiritual enlightenment damage of high frequency transformer take decreasing greatly and high frequency the second stoppage department ($D_5,\;D_6$) becomes soft switching, and also, switching damage absorption quantity characteristic that can come to life again as subordinate have, and to become tube stabilization design and result that manufacture and experiment, brought result that improve of 10% than existing equipment, and if supplement as systematic late, it becomes thought to get into superior result.

A Study on the Improvement of Injection Molding Process Using CAE and Decision-tree (CAE와 Decision-tree를 이용한 사출성형 공정개선에 관한 연구)

  • Hwang, Soonhwan;Han, Seong-Ryeol;Lee, Hoojin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.580-586
    • /
    • 2021
  • The CAT methodology is a numerical analysis technique using CAE. Recently, a methodology of applying artificial intelligence techniques to a simulation has been studied. A previous study compared the deformation results according to the injection molding process using a machine learning technique. Although MLP has excellent prediction performance, it lacks an explanation of the decision process and is like a black box. In this study, data was generated using Autodesk Moldflow 2018, an injection molding analysis software. Several Machine Learning Algorithms models were developed using RapidMiner version 9.5, a machine learning platform software, and the root mean square error was compared. The decision-tree showed better prediction performance than other machine learning techniques with the RMSE values. The classification criterion can be increased according to the Maximal Depth that determines the size of the Decision-tree, but the complexity also increases. The simulation showed that by selecting an intermediate value that satisfies the constraint based on the changed position, there was 7.7% improvement compared to the previous simulation.

Performance Evaluation of Rough Rice Low Temperature Drying Using Heat Pump (열펌프를 이용한 벼의 저온건조성능평가)

  • Kim, Hoon;Han, Jae-Woong
    • Food Engineering Progress
    • /
    • v.13 no.4
    • /
    • pp.308-313
    • /
    • 2009
  • This study was conducted to design and fabricate a heat pump that can produce some weather conditions similar to those of the dry season of the rough rice in Korea, and to investigate basic performances of the apparatus. During the drying test, the amount of energy consumption and drying characteristics were measured at four different temperature levels ranging between 20$^{\circ}C$ and 50${^{\circ}C}$. In the psychrometric chart, the freezing capacity and refrigerant circulation ratio of the heat pump were 173 kJ/kg and 49.6 kg/hr, respectively. Therefore, coefficient of performance was 5.5, which was superior to that of refrigerant R-22 (4.0) in standard refrigeration cycle. In addition, the time to reach target drying temperature (30${^{\circ}C}$) and relative humidity (40%) were 6 minutes and 7 minutes, respectively. Temperature differences between the drying temperature and the rice were 1.5${^{\circ}C}$ and 8.5${^{\circ}C}$ at the drying temperatures of 21.9${^{\circ}C}$ and 48.7${^{\circ}C}$, respectively. This result demonstrated that the increased temperature of the rice in the drying section decreased sufficiently in the tempering section. At the drying temperatures of 21.9, 30.7 38.8, and 48.7${^{\circ}C}$, drying rates were 0.29, 0.61, 0.85, and 1.26%/hr, respectively, which were similar to those of commercial dryer. In addition, the amounts of energy consumption were 325, 667, 692, and 776 kJ/kg, respectively. These results showed that this dryer saved up to 86% of energy consumption compared with the commercial dryer, which uses 4,000-5,000 kJ/kg of fossil fuel.

Sectoral System of Innovation and R&D Support Service: Focused on the Case of NUC Electronics (산업별 혁신시스템과 R&D 지원서비스 : 엔유씨전자 사례를 중심으로)

  • Kim, Yong-yul
    • Journal of Korea Technology Innovation Society
    • /
    • v.22 no.3
    • /
    • pp.362-381
    • /
    • 2019
  • The purpose of this study is to examine how two factors among various affecting factors of technological innovation, i.e. sectoral system of innovation and R&D support service, were actually applied in the case of NUC Electronics. This company has achieved high level of innovation performance through change of injection port and improvement of extracting rate. This was possible because each component of sectoral system of innovation system was matched with the innovation activity. The improvement of the performance in NUC Electronics was attributable to its own innovation efforts and R&D support service of government research institute. In the process of technological innovation, the company could receive high-level services in areas such as product design and virtual experiments that companies can not solve themselves. It can be said that the role of government and public institutions to support the shortage of SMEs was important. In terms of each component of sectoral system of innovation, we found that there were many opportunities of new technology; sustainability was low; imitation was easy; appropriability was low but it has dualily; accumulation of technology was relatively high, availability of external knowledge was high. At the same time, both of the company and the network played an important role, and market conditions were very favorable. In terms of R&D support services, it is a direct effect that a great deal of time and cost savings have been achieved through virtual experiments on the material and shape of the screw. As an indirect effect, the core competence of the company has been greatly strengthened by utilizing the momentum of technology development through external support, hence the company could establish the structure of virtuous circle of innovation.

Implementation of a citizen-driven smart city living lab community platform to improve pedestrian environment of school zone (스쿨존 보행환경 개선을 위한 시민참여형 스마트시티 리빙랩 커뮤니티 플랫폼 구현)

  • Jang, Sun-Young;Kim, Dusik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.415-423
    • /
    • 2021
  • Citizen participation and Living Lab are attracting interest as one of the major strategies for the success of smart cities. In a Living Lab, citizens, who are the end-users of technology, participate in the search for alternatives to define and solve problems and repeat experiments to verify alternatives in a circular process. The purpose of this research was to present an operating model of a citizen-participating online community platform to improve urban problems, implement and test it, and show its applicability. To this end, an operation model of a citizen-participating online community platform was proposed to improve urban problems. An online platform was designed and implemented to reflect the functions pursued by the operation model. Finally, a pilot test for the function was performed using the Oma Elementary School case located in Ilsan, Goyang-si, Gyeonggi-do. The operating model was designed with the city's pedestrian environment and children. As a result, the sharing and communicating process of urban issues among community members worked appropriately according to the designed intention. The Living Lab coordinator could visualize and view urban issues posted by users on a map based on location information. Visualizing the urban problem as a heat map confirmed that urban problems were concentrated in a specific area.

Comparison of heavy metal uptake of LID and roadside plants (도로변 및 LID 시설 식재 식물의 중금속 축적량 비교)

  • Lee, YooKyung;Choi, Hyeseon;Reyes, Nash Jett;Kim, Leehyung
    • Journal of Wetlands Research
    • /
    • v.23 no.1
    • /
    • pp.44-53
    • /
    • 2021
  • Urban stormwater runoff contains heavy metals that accumulate in on-site treatment systems, thus resulting to facility deterioration and maintenance problems. In order to resolve these problems, low impact development (LID) technologies that promote natural materials circulation are widely used. LID facilities are capable of treating heavy metals in the runoff by means of plant uptake; however, the uptake or phytoremediation capabilities of plants have not been studied extensively, making it difficult to select the most suitable plant species for a certain LID design. This study investigated the vegetative components of an LID facility, roadside plants, and plants in landscape areas with different heavy metal exposure and frequency to determine the uptake capabilities of different plant species. The plants harvested inside the LID facilities and roadsides with high vehicular traffic exhibited greater heavy metal concentrations in their tissues as compared with the plants in landscape areas. Generally, the accumulation of heavy metals in the plant tissues were found to be influenced by the environmental characteristics (i.e. influent water quality, air pollution level, etc.). Dianthus, Metasequoia, Rhododendron lateritium, and Mugwort were found to be effective in removing Zn in the urban stormwater runoff. Additionally, Dianthus, Metasequoia, Mugwort, and Ginkgo Biloba exhibited excellent removal of Cu. Cherry Tree, Metasequoia, and mugwort efficiently removed Pb, whereas Dianthus was also found to be effective in treating As, Cr, and Cd in stormwater. Overall, different plant species showed varying heavy metal uptake capabilities. The results of this study can be used as an effective tool in selecting suitable plant species for removing heavy metals in the runoff from different land use types.

Numerical Study on the Effect of a Groove of D-type on Internal Flow and Pressure Drop in a Corrugated Pipe (주름관 내부 유동과 압력강하에 대한 D형 그루브의 영향에 관한 수치해석)

  • Hong, Ki Bea;Kim, Dong Woo;Ryou, Hong Sun
    • Journal of Korean Society of Disaster and Security
    • /
    • v.14 no.1
    • /
    • pp.1-8
    • /
    • 2021
  • A corrugated pipe is widely used in firefighting equipment and sprinkler pipes because of its elasticity, which is less damaged by deformation and convenient facilities. However, the corrugated shape of the wall results in complex internal turbulent flow, and it is difficult to predict the pressure drop, which is an important design factor for pipe flow. The pressure drop in the corrugated tube is a function of the shape factors of the pipe wall, such as groove height, length, and pitch. Existing studies have only shown a study of pressure drop due to length changes in the case of D-shaped tubes with less than 5 pitch (P) and height (K) of the rectangular grooves in the tube. In this work, we conduct a numerical study of pressure drop for P/Ks with length and height changes of 2.8, 3.5 and 4.67 with Re Numbers of 55,000, 70,000 and 85,000. The pressure drop in the corrugated tube was interpreted to decrease with smaller P/K. We show that the pressure drop is affected by the change in the groove aspect ratio, and the increase in the height of the groove increases the recirculation area, and the larger the Reynolds number, the greater the pressure drop.