• Title/Summary/Keyword: 선형 측정법

Search Result 609, Processing Time 0.034 seconds

Comparison of Contact Resistivity Measurements of Silver Paste for a Silicon Solar Cell Using TLM and CTLM (TLM 및 CTLM을 이용한 실리콘 태양전지 전면전극소재의 접촉 비저항 측정 비교연구)

  • Shin, Dong-Youn;Kim, Yu-Ri
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.6
    • /
    • pp.539-545
    • /
    • 2014
  • Contact resistivity between silver electrodes and the emitter layer of a silicon solar cell wafer has been measured using either the circular transmission line method or the linear transmission line method. The circular transmission line method has an advantage over the linear transmission line method, in that it does not require an additional process for mesa etching to eliminate the leakage current. In contrast, the linear transmission line method has the advantage that its specimen can be acquired directly from a silicon solar cell. In this study, measured resistance data for the calculation of contact resistivity is compared for these two methods, and the mechanism by which the linear transmission line method can more realistically reflect the impact of the width and thickness of a silver electrode on contact resistivity is investigated.

Characteristics of Conducting Polymer-based Urea Sensors with Planar Pt Electrode on Silicon Substrate (전도성 고분자를 이용한 요소 측정용 반도체 바이오센서의 특성)

  • Park, Sung-Ho;Jin, Joon-Hyung;Min, Nam-Ki;Hong, Suk-In
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1454-1456
    • /
    • 2001
  • 신장병 진단에 중요한 요소의 농도를 측정하기 위한 요소 센서를 반도체 위에 개발이 연구의 목적이다. 센서의 감도 측정은 선형 전위 주사법(Linear sweep voltammtry)을 이용하였다. 선형 전위 주사법은 가역적이든 비가역적이든 관계없이 cottrell 식에 의한 전류와 농도의 직선관계로부터 감도를 측정할 수 있는 장점이 있고 또한 저 농도에서 민감하게 반응한다. 따라서 기존 전위차 측정형 바이오 센서(Potentiometric biosensor)에서 규명할 수 없는 감도 문제를 선형 전위 주사법으로 규명하고자 하였다. 센서전극은 p-type 실리콘 웨이퍼 위에 전극을 제작했다. 그 위에 cyclic voltammetry 법을 사용하여 전도성 고분자를 전기 중합 하였고, 그위에 다시 chronoamperometry법을 사용하여 우레아제를 고정화 하여 작업전극으로 제작하였다. 센서의 감도는 phosphate buffer 용액(pH7.4)속에서 온도 35$^{\circ}C$를 유지하며 측정하였다.

  • PDF

공정 플라즈마 진단을 위한 고조화파 분석법 및 진단 결과

  • Jeong, Jin-Uk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.29-29
    • /
    • 2011
  • 플라즈마 진단법은 플라즈마를 분석 및 이해하는데 매우 중요하다. 최근 플라즈마 쉬스의 비선형성을 이용한 고조화파 분석법이 개발되었다. 플라즈마 쉬스에 정현 전압을 인가하면, 쉬스의 비선형성 때문에 고조화 전류들이 발생하게 되는데, 이 고조파 전류들을 분석하면 플라즈마밀도와 전자 온도를 측정할 수 있다. 이 방법은 실시간 또는 고속으로 플라즈마 측정이 가능하고, 부도체 탐침을 사용할 수 있기 때문에, 식각 또는 증착 플라즈마에서는 측정이 가능한 장점이 있다. 본 발표에서는 진단법의 원리와 공정 플라즈마 장비에서 진단 결과들을 소개하고자 한다.

  • PDF

공정 플라즈마에서 실시간 유전박막두께 측정법의 보상연구

  • Lee, Yeong-Ho;Choe, Ik-Jin;Kim, Yu-Sin;Jang, Seong-Ho;Jeong, Jin-Uk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.442-442
    • /
    • 2010
  • 공정 플라즈마 장치에서 이중 주파수법을 이용하여 실시간 유전박막 두께 측정법에 대한 보상연구를 하였다. 이중 주파수법은 유전박막과 플라즈마 쉬스를 간단한 전기적인 등가회로로 모델링하여 유전박막의 두께를 측정하는 방법이다. 이중 주파수법의 문제는 측정탐침의 인가전압에 따른 유전박막의 두께 측정치가 다르다는 점이다. 플라즈마 쉬스를 선형 저항만으로 등가하였기 때문에, 쉬스의 인가전압에 상관없이 쉬스 저항의 값이 일정하다는 가정이 존재한다. 그러나 쉬스 저항은 쉬스의 인가전압에 종속적이면서 비선형적인 특성을 갖는다. 측정 탐침에 출력 전압이 인가될 때 쉬스 양단에서 인가전압에 따른 쉬스의 등가저항의 비선형성을 고려하여 측정 탐침에 증착된 유전박막의 커패시턴스성분에 대한 방정식을 Numerical analysis로 풀어 유전박막의 두께 측정값을 보상하였다. 보상된 위의 방법으로 다양한 RF파워, 압력에 따라 $Al_2O_3$박막의 두께를 실시간으로 측정하여 비교하였다. 그 결과 이 방법은 낮은 플라즈마 밀도(${\sim}10^9cm^{-3}$)에서도 인가전압에 따른 유전 박막두께측정의 오차를 줄일 수 있었다.

  • PDF

Measurement of the Nonlinear Optical Properties by use of the Far-Field Phase Modulation Method (Far-field 위상 변조량 측정법을 이용한 광학매질의 비선형 특성 측정)

  • 김성훈;양준목;김용평;이영우;신동주;정영붕
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.3
    • /
    • pp.168-174
    • /
    • 1998
  • We have measured nonlinear refractive index and nonlinear absorption coefficient of optical materials by using a far-field phase modulation technique. The phase variation of the probe beam in the nonlinear material is transformed into the spatial phase modulation in the far-field so that the spatial distribution of the optical intensity in conjunction with the computer simulation analysis can give the nonlinear optical constants. We have obtained the nonlinear refractive indices and nonlinear absorption coefficient of $CS_2$ and $BaF_2$ by fitting the experimental values and numerical simulation analysis of far-field measurements. The nonlinear refractive indices of $CS_2$ and $BaF_2$were obtained as $1.2{\times}10^{-11}$ esu and $1.0{\times}10^{-13}$ esu, respectively at 616 nm, and the nonlinear absorption coefficient of BaF$_2$as $5.0{\times}10^{-11}$cm/W at 308nm. These measured values were in good agreement with previous reports.

  • PDF

Measurement of Elastic Modulus of Structural Ceramics by Acoustic Resonance Method (공진법을 이용한 구조용 세라믹의 탄성계수 측정)

  • An, Bong-Yeong;Kim, Yeong-Gil;Lee, Seung-Seok
    • Korean Journal of Materials Research
    • /
    • v.5 no.3
    • /
    • pp.268-274
    • /
    • 1995
  • 세라믹재료의 동탄성계수 측정을 위한 공진주파수 측정장치를 구성하였다. 구조용 세라믹 재료로 이용되는 $Al_{2}$O_{3}$, SiC, $Si_{3}$N_{4}$의 온도를 120$0^{\circ}C$까지 5$0^{\circ}C$의 온도간격으로 올리면서 torsional resonant frequency와 flexural resonant frequency를 측정하고, 측정된 공진주파수로부터 각 재료의 탄성계수를 구하였다. SiC의 경우는 120$0^{\circ}C$의 온도까지 탄성계수가 선형적으로 감소하였으나, $Al_{2}$O_{3}$와 $Si_{3}$N_{4}$의 경우에는 각각 100$0^{\circ}C$와 80$0^{\circ}C$까지는 선형적으로 감소하나, 그 이상의 온도에서는 탄성게수의 감소폭이 증가하는 현상을 보였다. 이러한 현상은 다결정재료에서의 grain boundary sliding에 의한 것으로 알려져 있다. 상온에서 공진법으로 측정된 동탄성계수의 측정결과는 초음파법으로 측정한 결과와 비교하였는데, 4% 내에서 서로 일치하는 결과를 보였다.

  • PDF

Investigating Uncertainty in Flow Measurement and Developing Rating Curves (유량측정시 불확실성의 검토와 수위-유량곡선식의 개발)

  • Lee, Kil Seong;Lee, Kyung Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.1242-1246
    • /
    • 2004
  • 본 연구에서는 유속계와 봉부자를 동한 측정값의 불확실성를 검토한 후, 한강의 7개 지류의 실측 자료들의 불확실성을 ISO 규정을 통하여 추정하였다. Simulated Annealing 기법과 황금비 분할법을 이용한 비선형회귀식을 적용하여 기존의 수위-유량 곡선식자 비교해보았다. 불확실성 추정결과 유량 측정치들의 불확실성이 ISO 규정의 기준에 비해 높게 추정되었으며, 특히 무작위 오차와 계통 오차 중에 무작위 오차의 불착실성이 높게 나타났다. 또한, 기존 수위-유량곡선식과 Simulated Annealing 기법과 황금비 분할법을 이용한 방법을 비교해본 결과 황금비 분할법이 가장 좋은 결과를 얻었다. 이때 수위-유량곡선식의 영수위값을 황금비 분할법을 이용해 구한 후 비교해 본 결과는 기존의 선형회귀방법과 비선형방법에서 큰 차이를 보이지 않았다. 또한 곡선 분리시에는 하나의 수위-유량곡선일때보다 오차가 줄어드는 경향을 보였다.

  • PDF

Compensation of Laser system using Optimization Methods in Multiple Environments (다중 환경에서의 최적화 기법을 이용한 레이저 시스템의 비선형성 보정)

  • Hong, Min-Suk;Lee, U-Ram;Choi, In-Sung;Heo, Gun-Hang;Kim, Jong-Eul;You, Kwan-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1773-1774
    • /
    • 2006
  • 나노 기술의 급격한 발달에 따라 나노미터 수준의 정밀도를 갖는 초정밀 측정 기술이 여러 분야에서 요구되고 있다. 헤테로다인 레이저 간섭계를 이용하여 초정밀 위치 측정을 하려고 할 때, 광학기기 자체의 불완전함에서 발생하는 비선형성 오차는 주요한 요소로 작용한다. 본 논문에서는 헤테로다인 레이저 간섭계 시스템에서의 비선형성을 보정해주기 위해 적응형 알고리즘을 제안한다. 기준 입력인 정전용량센서와 최소자승법을 이용하여 보정변수를 구한 후, 반복 최소자승법을 이용하여 비선형성에 따른 타원 위상을 비선형성이 보정된 원 위의 위상으로 사상시킨다.

  • PDF

Deformation Characteristics of Diaphragm Wall Induced by Deep Excavation(II) -Numerical Analysis- (대규모 굴착공사에 따른 지중연속벽체의 변형특성(II) -수치해석-)

  • 김동준;이병철;김동수;양구승
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.4
    • /
    • pp.107-115
    • /
    • 2001
  • 해성토층 위에 준설매립된 수도권 해안매립지역에서 원형의 대심도 굴착공사로 인하여 발생하는 지중연속벽의 수평변위를 예측하기 위하여 수치해석을 수행하였고, 이러한 수치해석결과와 현장측정값을 비교하여 각각의 수치해석방법의 적용성을 평가하였다. 수치해석법으로는 지반반력해석, 선형 유한요소법 그리고 비선형 유한요소법이 수행되었다. 각각의 방법들에서는 미소변형률에서의 지반거동특성인 비선형성과 굴착으로 인한 구속압감소효과를 고려한 경우와 고려하지 않은 경우에 대하여 수치해석을 수행하여 각각 그 결과들을 비교.분석하였다. 이러한 분석결과 미소변형률에서의 비선형성과 굴착으로 인한 구속압감소 효과를 고려한 비선형 유한요소해석법이 가장 정확하게 수평변위를 예측할 수 있는 방법임을 알 수 있었다.

  • PDF