• Title/Summary/Keyword: 선예도

Search Result 49, Processing Time 0.021 seconds

A Composite DorsoPlantar Axial X-ray Projection Study on the Bones of the Whole Infant's Foot (유아 발 전체의 뼈에 대한 합성 전후축방향 엑스선촬영법 연구)

  • Park, Yun;Ahn, Byung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.1007-1013
    • /
    • 2021
  • A Study that Cronbach Alpha values were Significantly higher at 0.813 in the Composite AP axial Radiography Signal to Noise Ratio(SNR) for Evaluating uniform Density and Advanced Images of the Entire Foot without overlap with the legs. The Subjective Evaluation ROC also scored a high score of 18 on Foot Calcaneus bone 10° from the Foot Metatarsal bone, and 18 on the Examination by tilting the Sharpness X-ray Tube 20° from the Foot Calcaneus bone. Results show uniform Density and images at 10° rearward of Foot Metatarsal bone and 20° forward of Foot Calcaneus bone during the Composite AP axial Radiography X-ray Examination of Infants.

미국의 사서직 윤리강령

  • Kim, Jeong-Geun
    • KLA journal
    • /
    • v.9 no.8
    • /
    • pp.21-22
    • /
    • 1968
  • 전문직의 특징을 우리는 두가지로 말할 수 있다. 첫째 전문직이 수행하는 일의 성격이 관례적이며 일상적인 것이 아니고 지적인 판단력을 요하는 것이라는 점이다. 둘째 전문지그이 일은 그 목적이 개인의 금전적 이익에 있지 아니 하고 대사회봉사에 있다는 점이다. 바로 이 점이 전문직단체에서 윤리강령을 표방하게 되는 소이이다. 그래서 어떤 이들은 전문직의 특징을 말할 때 첫째 일의 성격이 지적이란 것과 둘째 직업윤리강령을 갖고 있다는 것을 들기도 한다. 지금 우리나라에서는 사서직이 전문직으로서 그 기반을 굳히려고 안간힘을 쓰는 중에 있다. 여러 가지 방면의 노력이 요구되겠지만, 외국의 선예에 따라 한국사서직의 윤리강령을 제정하는 일이 우리 앞에 놓인 한가지 중대한 과제가 아닐 수 없다. 우리가 이 작업을 시작할 때 참고가 될까싶어 미국의 사서직윤리강령을 번역ㆍ소개하는 바이다. 여기에 싣는 전문을 포함하여 28조목에 걸친 내용은 1938년 ALA에 의하여 채택된 이래 지금까지 통용되고 있는 것으로서 현재 미국에서는 본강령에 대한 개정안이 제시되어 관계인들에 의하여 검사중에 있음을 부기하여 둔다.

  • PDF

Study on the auto focus digital camera uses a Liquid Lens. (Liquid Lens를 사용하는 디지털 카메라의 자동초점조절에 관한 연구)

  • Kim, Nam-woo;Hur, Chang-Wu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.557-560
    • /
    • 2015
  • 자동초점이란 영상을 획득하는 시스템에서 고정된 촬상면에 자동으로 초점이 맺히도록 렌즈를 구동시키는 방식으로 컴퓨터비전과 카메라 등에서 매우 중요하게 사용된다. 소형 카메라의 경우 자동초점에서 렌즈구동부인 actuator의 기술은 대량생산이 이용이하고, 위치센서가 불필요하며, 회로구성이 용이한 VCM방식이 널리 사용되고 있으며, 구동의 안정성에 비해 크기와 소음이 큰 스테핑모터 방식, 크기는 가장 작지만 납 함유문제 및 습도 취약성을 갖는 피에조 방식이 있다. 그 외에 액체렌즈방식이 있는데, 소형 구조에 저전력의 장점이 있지만 화질 및 신뢰성 검증 그리고 고압이 필요한 특징을 가지는 구조도 있다. 본 논문에서 5Mpixel급 이미지 센서를 통해 획득한 영상의 선예도를 이용하여 VCM의 actuator처럼 액체렌지를 제어하여 자동으로 초점을 맞추는 제어방식을 구현하고 검증하였다.

  • PDF

Optimization of the Empirical Method to the Enhancement Image of the Four Chambers at the Same Time in the Pediatric Cardiac Computed Tomography (소아 심장 전산화단층촬영 검사에서 4 chamber의 동시 조영증강 영상에 대한 최적화 방안)

  • Park, Chanhyuk;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.279-285
    • /
    • 2014
  • This study is to have dose reduction and minimization of excessive use of contrast medium in the pediatric cardiac computed tomography and to suggest the optimization plan to acquire the enhancement image of the 4 chambers at the same time by formulating scan delay time in empirical method with considering variables such as contrast medium injection velocity and cardiac approaching time. Quantitative, qualitative and dose assessment were carried out for 30 pediatric patients who had taken the cardiac examination. In conclusion, image enhancement in 4 chambers of the cardiac shows over 300 HU which is proper to pediatric cardiac reading by applying the empirical method with calculating scan delay time according to weight and contrast medium volume and injection velocity. Qualitative image assessments in confidence sharpness and noise have excellence qualitatively. Exposure dose to pediatrics also decreases precisely. Therefore this study is judged to take a important role of making optimization images with advantages of dose reduction and less side effects caused by it's excessive use in clinic.

Quality Improvement on Upper Gastrointestinal Series (위장조영검사에서 화질 개선 방법)

  • Lim, Byung-Hak;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.395-401
    • /
    • 2016
  • Upper gastrointestinal series is a diagnostic test that X-ray passes through the stomach after administering contrast media such as barium or gastrografin. Upper gastrointestinal series with an advantage of no side effect except temporary constipation or abdominal pain has been widely used to diagnose diseases of the gastrointestinal system. However, image degradation and diagnostic accuracy frequently occurred when improper movement and breath control were carried out by lack of understanding the overall inspection process for the upper gastrointestinal series. The movie of the upper gastrointestinal series was made for improving inspection accuracy and image quality. The examinees encouraged to see the movie for waiting time before doing upper gastrointestinal series. In this study, image quality and diagnostic accuracy was examined for the effect of the movie about upper gastrointestinal series. 60 patients composed of each 10 people from 30s to 80s were selected randomly among both 2,940 examinees in 2014 and 3,076 examinees in 2015. Image quality was evaluated by the full width at half maximum of profile for each image using the Image J. The measurement of the full width at half maximum showed 0.208 mm and 0.133 mm for after and before seeing the movie. Thus it was verified that the movie education could improve the image quality and diagnostic accuracy for upper gastrointestinal series.

A Study Radiograph Techniques for Diagnosis of Axillary Fracture Ribs in X-ray (X-ray 갈비뼈 촬영에서 겨드랑이쪽의 골절된 갈비뼈 진단을 위한 촬영법 연구)

  • Ahn, Byung-Ju;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.979-986
    • /
    • 2019
  • The purpose of this study devised a method for the examination of the images of the first and second rib fractures of the axillary using Rib Rando Phantom. The position of the phantom and the angle of the X-ray tube were changed to vertical, head 5° and foot 5°. The Radiological Technologists subjectively evaluated the acquired images and the evaluation data were analyzed by SPSS 3.0 ver. The signal to noise ratio(SNR) was calculated using the ImageJ Program. As a result, the cronbach alpha value was significantly higher at 0.789. The SNR was highest at 6.038 when the X-ray tube was tilted 5° toward the head in the front of the ribs and highest at 7.860 when the X-ray tube was tilted 5° toward the foot. Radiographic Techniques proposed axillary ribs this study are as follows. The anterior rib scan is examined by elevating the fractured area and changing the X-ray tube angle by 5° towards the head. The posterior ribs scan is examined by attaching the fractured area and changing to the X-ray tube angle by 5° towards the foot. It is considered that such an inspection method can obtain a sharp image.

Change of MTF for Sampling Interval in Digital Detector (디지털 검출기에서 샘플링 간격에 따른 MTF의 변화)

  • Cho, Hyungwook;Chon, Kwonsu
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.5
    • /
    • pp.225-230
    • /
    • 2014
  • Assessments of medical image was improved in accordance with development of medical imaging systems. One of them is edge method to determining MTF(Modulation Transfer Function) based on the Fujita method. Fujita was reduced sampling interval used slightly angulated slit to the direction of pixel array and composited finely sampled LSF to determine presampling MTF. In this study, we investigate the effect of sampling interval on the MTF under a digital imaging system by changing wire angle. The wire method was equivalent to the slit method except signal appearance. A Simens's MAMMOMAT Inspiration with $0.085{\times}0.085mm^2$ pixel size made by amorphous selenium was used and 96% accuracy on MTF in twice sampling interval compared with Fujita was obtained. However, three times of sampling interval showed 93% accuracy on 50% of MTF and 85% accuracy on 10% of MTF.

Portal Vein Thrombosis in a Dog with Dirofilariasis (심장사상충에 감염된 개에서 발생한 문정맥혈전증)

  • Yun, Seok-Ju;Cheon, Haeng-Bok;Han, Jae-Ik;Kang, Ji-Houn;Chang, Jin-Hwa;Na, Ki-Jeong;Chang, Dong-Woo
    • Journal of Veterinary Clinics
    • /
    • v.27 no.5
    • /
    • pp.600-604
    • /
    • 2010
  • A ten-year-old female mongrel dog was presented to Veterinary Medical Center, Chungbuk National University with the signs of anorexia, weakness, and hemoglobinuria. Patient had been diagnosed as dirofilariasis based on heartworm antigen test and treated with adulticide (melarsomine) at local hospital one day before admission. On laboratory examinations, there were hypochromic and microcytic regenerative anemia, thrombocytopenia, moderate neutrophilia, and increase ALT, AST, and ALP. Radiographic exam showed main pulmonary artery bulging, pulmonary infiltration and hypervascularity, reduced abdominal serosal detail and mild hepatomegaly. Abdominal ultrasonographic exam showed mild peritoneal effusion and large hyperechoic thrombi at trifurcation of the porta hepatica and the splenic vein. In addition, intraluminal low density area and intravascular filling defect were confirmed on contrast enhanced CT scanning at the same anatomic locations. Patient was treated with anticoagulant and thrombolytic therapy. On day 42 after treatment, complete resolution of thrombi was confirmed via ultrasonography and improvement of clinical signs was observed.

The MTF Measurement of the Conventional X-ray System by using the Computed Radiography (CR을 이용한 일반촬영장치의 MTF 측정)

  • Kim, Chang-Bok
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.111-115
    • /
    • 2005
  • The quality of image from the system that creates medical images by using X-ray depends on the various different reasons such as the X-ray generator, the subject and the image transmission medium. In other words, thereare various factors existing that can influence on the quality of image from the moment when the X-ray is generated and until the final image is created. Therefore, the operator who creates images at the clinical site should make continuous evaluation and observation from the final image. There are various methods of evaluating the medical images, but it is assumed that the MTF measurement method can be suitable for measuring actual or effective resolution. So in this study, the MTF measurement method by using X-ray film has been avoided and the MTF features according to the deterioration of the X-ray system have been measured by using the software (the program used Borland C++ builder software and LEAD tools software) that can measure the MTF of the digital medical images. As the result of this measurement, it has been found out through the MTF graph that the resolution and sharpness from the old x-ray generator with a many years of using and many numbers of times of using were deteriorated for the quality of image comparing to those from the new system. Also a simple and easy measurement method for the MTF from the digital medical images can be obtained in this study.

  • PDF

Evaluation of Image Quality for Compressed SENSE(CS) Method in Cerebrovascular MRI: Comparison with SENSE Method (뇌혈관자기공영영상에서 Compressed SENSE(CS) 기법에 대한 영상의 질 평가: SENSE 기법과 비교)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.999-1005
    • /
    • 2021
  • The object of this research is CS, which increases resolution while shortening inspection time, is applied to MRA to compare the quality of images for SENSE and CS techniques and to evaluate SNR and CNR to find out the optimal techniques and to provide them as clinical basic data based on this information. Data were analyzed on 32 patients who performed TOF MRA tests at a university hospital in Chung cheong-do (15 males, 17 females), ICA stenosis:10, M1 Aneurysm:10, and average age 53 ± 4.15). In the inspection, the inspection equipment was Ingenia CX 3.0T, Archieva 3.0T, and 32 channel head coil and 3D gradient echo as a method for equipment data. SNR and CNR of each image were measured by quantitative analysis, and the quality of the image was evaluated by dividing the observer's observation into 5 grades for qualitative evaluation. Imaging evaluation is described as being significant when the p-value is 0.05 or less when the paired T-test and Wilcoxon test are performed. Quantitative analysis of SNR and CNR in TOF MRA images Compared to the SENSE method, the CS method is a method measurement method (p <0.05). As an observer's evaluation, the sharpness of blood vessels: CS (4.45 ± 0.41), overall image quality: CS (4.77 ± 0.18), background suppression of images: CS (4.57 ± 0.18) all resulted in high CS technique (p = 0.000). In conclusion, the Compressed SENSE TOF MRA technique shows superior results when comparing and evaluating the SENSE and Compressed SENSE techniques in increased flow rate magnetic resonance angiography. The results are thought to be the clinical basis material in the 3D TOF MRA examination for brain disease.