• Title/Summary/Keyword: 선량-반응

Search Result 349, Processing Time 0.026 seconds

The ionization chamber response function from the measured and the corrected by Monte Carlo simulation. (측정된 원통형 전리함 반응함수의 몬테카를로 시뮬레이션 보정)

  • 이병용;김미화;조병철;나상균;김종훈;최은경;장혜숙
    • Progress in Medical Physics
    • /
    • v.7 no.1
    • /
    • pp.9-17
    • /
    • 1996
  • The response function of ionization chambers are measured in the narrow radiation field Nominal photon energies are 4MV, 6MV and 15MV. the Radii of the chambers are 0.5cm~3.05cm and the field size is 0.2$\times$20$\textrm{cm}^2$. The measurements are taken in the water phantom at 10cm depth. The beam kernel (radiation distribution profile) for narrow radiation field in the phantom are obtained from Monte Carlo simulation (EGS4, Electron Gamma Shower 4). The beam kernel components in the measured chamber response function are deconvolved in order to get the ideal chamber response function of the $\delta$-shaped function radiation field. The chamber response functions have energy dependent tendency before deconvolution, while they show energy invariant properties, after the components of beam kernels are removed by deconvolution method.

  • PDF

Response for Lead Block Thickness of Parallel Plate Detector using Dielectric Film (유전체필름을 이용한 평행판검출기의 납 차폐물 두께변화에 대한 반응)

  • Kim Yong-Eun;Cho Moon-June;Kim Jun-Sang;Oh Young-Kee;Kim Jhin-Kee;Shin Kyo-Chul;Kim Jeung-Kee;Jeong Dong-Hyeok;Kim Ki-Hwan
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • A parallel plate detector containing PTFE films in FEP film for relative dosimetry was designed to measure the response of detectors to S and 10 MV X-rays from a medical linear accelerator through different thicknesses of lead. The dielectric materials were 100 m thick. The set-up conditions for measurements with this detector were as follows: SSD=100 cm the test detector was at a depth of 5 cm and the reference chamber was at a depth of 10 cm from the phantom surface for 6 and 10 MV X-rays. Lead blocks were designed to cover the irradiated field. They were added to the tray to increase thickness sequentially. We found that the detector response decreased exponentially with the thickness of lead added. The linear attenuation coefficients of the test detector and reference chamber were 0.1414 and 0.541, respectively, for 6 MV X-rays and 0.1358 and 0.5279 for 10 MV X-rays. The test detector response was greater than that of the reference chamber. The response function was calculated from the measured values of the test detector and reference chamber using optimization. These optimized constants for the detector response function were independent of theenergy. As a result of optimizing the response function between detectors, the use of a relative dosimeter was validated, because the response of the test detector was 1% for 6 MV X-rays and 4% for 10 MV X-rays.

  • PDF

Effects of Low Dose $\gamma$-Radiation on the Growth, Activities of Enzymes and Photosynthetic Activities of Gourd (Lagenaria siceraria) (저선량 $\gamma$선 조사가 참박의 초기 생육과 효소 활성 및 광합성 능에 미치는 영향)

  • 이혜연;김재성;백명화;이영근;임돈순
    • Korean Journal of Environmental Biology
    • /
    • v.20 no.3
    • /
    • pp.197-204
    • /
    • 2002
  • Gourd seeds were irradiated with the doses of 0-20 Gy to investigate the effect of the low dose $\gamma$-radiation on the early growth and physiological activity. The stimulating effects of the low dose y- radiation on the early growth were not noticeably high, but were increased generally at 4-16 Gy irradiation group. The catalase and peroxidase activity of cotyledon from seeds irradiated with $\gamma$- radiation were increased at 8 Gy irradiation group. The photochemical activity of leaf was noticeably high at 4 Gy irradiation group. The photochemical yield of PSII, estimated as Fv/Fm, decreased with increasing illumination time by 50% after 4 hrs in the control and 8 Gy irradiation group, while Fo slightly increased. However, Fv/Em in the 4 Gy irradiation group decreased by 40% of inhibition, indicating that photoinhibition decreased by the low dose $\gamma$- radiation. Changes in the effective quantum yield of PSII, $\varphi_{PSII}$ and 1/Fo- l/Fm, a measure of the rate constant of excitation trapping by the PSII reaction center, showed similar pattern to Fv/Em. NPQ decreased by 70% after photoinhibitory treatment with showing similar pattern between the control and the irradiation group. These results showed the positive effect of low dose $\gamma$- radiation on the seedling growth and the reduction of photoinhibition in the 4 Gy irradiation group.

Neutron Dose Measurements Using TLDs in a 252Cf Neutron Field (252Cf 중성자장에서 열형광선량계(TLD)를 이용한 중성자 방사선량 측정)

  • Chang, Insu;Kim, Sang In;Lee, Jung Il;Kim, Jang Lyurl;Kim, Bong Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.1
    • /
    • pp.37-43
    • /
    • 2013
  • In case of neutron dose measurement using TLDs (thermo-luminescence dosimeters), because the neutron energy dependence of the TLD is very high, the calibration of the energy response according to the characteristics of the neutron spectrum of workplace is required. In the present study, the ambient dose equivalent rates inside and around the Long-Counter (neutron detector) with narrow and complex inside in the neutron field of $^{252}Cf$ were evaluated. The calibration factors to account for the neutron energy dependence of TLDs were established for both the bare and $D_2O$ modulated $^{252}Cf$ neutron beams, respectively. The values of the TLD's measurement were compared with the computational results of the MCNPX (Monte Carlo N-Particles transport code). When using the two calibration factors of the TLD than a single calibration factor, the measured and the calculated values at the point of verification outside and inside the Long-Counter were in more good agreement. This results show that TLD should be calibrated in the reference neutron field similar to workplace situation.

Dosimetric Properties of LiF:Mg,Cu,Na,Si TL pellets (LiF:Mg,Cu,Na,Si TL 소자의 선량계적 특성)

  • Nam, Young-Mi;Kim, Jang-Lyul;Chang, Si-Young
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.1
    • /
    • pp.7-12
    • /
    • 2001
  • Sintered LiF:Mg,Cu,Na,Si thermoluminescence (TL) pellets were developed for application in radiation dosimetry. In the present study, the TL dosimetric properties of LiF:Mg,Cu,Na,Si TL pellets have been investigated for emission spectrum, dose response, energy response, and fading characteristics. LiF:Mg,Cu,Na,Si TL pellets were made by using a sintering process, that is, pressing and heat treatment from TL powders. Photon irradiations for the experiments were carried out using X-ray beams and a $^{137}Cs$ gamma source at the Korea Atomic Energy Research Institute (KAERI). The average energies and the dose were in the range of 20-662 keV and $10^{-6}-10^{-2}\;Gy$, respectively. The glow curves were measured with a manual type TLD reader(System 310, Teledyne) at a constant nitrogen flux and a linear heating rate. For a constant heating rate of $5^{\circ}C\;s^{-1}$, the main dosimetric peak of glow curve appeared at $234^{\circ}C$, the activation energy was 2.34 eV and frequency factor was $1.00{\times}10^{23}$. TL emission spectrum is appeared at the blue region centered at 410 nm. A linearity of photon dose response was maintained up to 100 Gy. The photon energy responses relative to $^{137}Cs$ response were within ${\pm}20%$ at overall photon energy region. The fading of TL sensitivity of the pellets stored at the room temperature was not found for one year.

  • PDF

Effects of Combined Irradiation of Neutrons and ${\gamma}$-Rays on the Pink Mutation Frequencies in Tradescantia (중성자와 감마선 중복 조사가 자주달재비 분홍돌연변이율에 미치는 영향)

  • Kim, Jin-Kyu;Lee, Young-Keun;Kim, Jae-Sung;Shin, Hae-Shick;Hyun, Soung-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.2
    • /
    • pp.67-73
    • /
    • 2000
  • The effects of combined irradiation of neutrons and ${\gamma}$-rays were analysed by means of Tradescantia stamen hair (TSH) assay. Potted plants were irradiated with $0{\sim}2$ Gy of ${\gamma}$-rays. For the combined treatments, the plants were irradiated with neutrons from $^{252}Cf$ 24 hours before or after ${\gamma}$-irradiation. The slopes of dose-response curves were 5.98, 6.17 and 7.48, in ${\gamma}$-rays, ${\gamma}$-rays+neutrons, and neutrons+${\gamma}$ -rays irradiated groups, respectively. The biological efficacy of radiations in the induction of pink mutations increased by 25% in neutrons+${\gamma}$-rays irradiated group, while it increased by 12% in ${\gamma}$-rays+neutrons irradiated group. The combined irradiation with two kinds of radiations results in the different efficacy of radiation depending on the order of irradiations, which is of great importance in the related fields such as sterilization and radiotherapy.

  • PDF

The cytokinesis-block micronucleus assay as a biological dosimeter in irradiated lymphocyte : Comparison of the response of mouse and human (임파구의 미세핵 분석법을 이용한 생물학적 방사선 피폭선량 측정 : 마우스와 인체에서의 반응비교)

  • Kim, Sung-ho;Cho, Chul-koo;Kim, Tae-hwan;Yoo, Seong-yul;Koh, Kyoung-hwan;Yun, Hyong-geun;Koh, Joo-hwan;Choi, Soo-yong
    • Korean Journal of Veterinary Research
    • /
    • v.33 no.3
    • /
    • pp.487-492
    • /
    • 1993
  • 정상인 말초혈액임파구 및 C57BL/6마우스 비장임파구에 $^{60}Co{\gamma}-rays$를 in vitro상태에서 조사한 후 500개 또는 1000개의 cytokinesis-blocked(CB) lymphocytes의 미세핵(micronuclei)의 발생빈도를 측정하였다. 방사선조사량에 따라 미세핵의 발생빈도는 증가하였으며 linear-quadratic model로 측정한 결과 선량반응곡선의 식은 인체의 경우 $Y=(0.31{\pm}0.049)D+(0.0022{\pm}0.0002)D^2+13.19$($r^2=1.000$)이었으며, 마우스의 경우 $Y=(1.31{\pm}0.264)D+(0.0015{\pm}0.0006)+8.7$($r^2=0.988$)이었다(Y는 1000개의 CB cell 당 미세핵발생빈도, D는 cGy로 표시되는 조사선량). 인체 말초혈액임파구에 대한 마우스 비장임파구의 상대적 생물학적 효과(relative biological effectiveness)는 미세핵의 발생율이 세포당 0.05~0.8의 범위에서 $1.84{\pm}0.48$이었다. 미세핵분석법은 인체 및 동물의 방사선 피폭시 간편하고 빠른 생물학적 선량측정법으로 사용될 수 있을 것이다.

  • PDF

Fast Neutron Flux Determination by Using Ex-vessel Dosimetry (노외 감시자를 이용한 압력용기 중성자 조사량 결정)

  • Yoo, Choon-Sung;Park, Jong-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.4
    • /
    • pp.158-167
    • /
    • 2007
  • It is required that the neutron dosimetry be present to monitor the reactor vessel throughout its plant life. The Ex-vessel Neutron Dosimetry Systems which consist of sensor sets, radiometric monitors, gradient chains, and support hardware have been installed for 3-Loop plants after a complete withdrawal of all six in-vessel surveillance capsules. The systems have been installed in the reactor cavity annulus in order to characterize the neutron energy spectrum over the beltline region of the reactor vessel. The installed dosimetry were withdrawn and evaluated after a irradiation during one cycle and then compared to the cycle specific neutron transport calculations. The reaction rates from the measurement and calculation were compared and the results show good agreements each other.

Effect of Additives on the Radiation-Induced Grafting of Styrene onto Polypropylene Fabric (폴리프로필렌 부직포에 스틸렌의 방사선 그라프트 반응에서 첨가제의 영향)

  • Park, Jong Shin;Nho, Young Chang;Jin, Joon-Ha;Lee, Myun Zu
    • Applied Chemistry for Engineering
    • /
    • v.7 no.5
    • /
    • pp.938-945
    • /
    • 1996
  • The present studies are to describe the grafting reaction of styrene in various solvents to polypropylene fabric by the simultaneous method using Co-60. The influence of various factors such as absorbed dose, dose rate, type of solvent, acid and multifunctional monomer were evaluated. At constant absorbed dose, the grafting yield was found to be higher at low dose rate. The initial rate of grafting was found to be proportional to a 0.56 power of dose rate. The inclusion of mineral acid in the grafting solution led to an increase in radiation grafting yield at almost all monomer concentration examined. Multifunctional monomer was also effective to increase grafting yield. The addition of both acid and multifunctional monomer was found to accelerate the grafting yield much more than the separate addition of two additives.

  • PDF

Comparative Study on Biological Effects of Gamma-Radiation and Bisphenol A with Tradescantia Micronucleus Assay (자주달개비 미세핵 분석법을 이용한 비스페놀 에이 및 감마선의 생물학적 영향 비교 연구)

  • 신해식;송희섭;현성희;이진홍;김진규
    • Korean Journal of Environmental Biology
    • /
    • v.20 no.2
    • /
    • pp.158-164
    • /
    • 2002
  • Some of synthetic chemicals can net as an endocrine disrupting substance in higher animals. Dioxins, DDT, PCBs and bisphenol A (BPA) are classified into endocrine disruptors and aye under a strict control in many countries. This research was designed to compare the clastogenic effects of BPA to those of ionizng radiation to establish the relaltive effectiveness of BPA by means of Tradescantia micronucleus assay. For the uptake of the BPA through the stems, groups of fresh cuttings of Tradescantia BNL 4430 weve placed in BPA solutions of 0 to 4 $\mu$M for 6 hours under continuous aeration. The other groups of the cuttings were irradiated with 0 to 0.5 Gy of gamma- rays. The frequencies of micronucleus showed a positive dose- response relationship in the range of 0 to 0.5 Gy, and a clear concentration-response relationship in the experimental range of BPA concentrations. By comparing the two experimental results, it is possible to estimate the BPA concentration and its equivalent radiation dose for a fixed value of MCN frequency. BPA of $ll.8\mu{M}$ can give rise to 53.3 MCN/100 tetrads, which is the same frequency induced by 25 cGy of gamma- rays. It is of biological importance that clinical symptoms start to develop after a whole body exposure to radiation higher than 25 cGy. The results indicate that the pollen mother cells are an excellent biological end- point for toxicity test of suspected endocrine disrupting chemicals such as bisphenol A, cotylphenol and nonylphenol.