• Title/Summary/Keyword: 선량지수

Search Result 159, Processing Time 0.028 seconds

Impact of Respiratory Motion on Breast Cancer Intensity-modulated Radiation Therapy (유방암 세기조절방사선치료에서의 호흡운동 영향)

  • Chung, Weon Kuu;Chung, Mijoo;Shin, Dong Oh;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.93-97
    • /
    • 2016
  • In this study, we evaluate the effect of respiration on the dose distribution in patient target volume (PTV) during intensity-modulated radiation therapy (IMRT) and research methods to reduce this impact. The dose distributions, homogeneity index (HI), coverage index (CVI), and conformity index of the PTV, which is calculated from the dose-volume histogram (DVH), are compared between the maximum intensity projection (MIP) image-based plan and other images at respiration phases of 30%, 60% and 90%. In addition, the reducing effect of complication caused by patient respiration is estimated in the case of a bolus and the expended PTV on the skin. The HI is increased by approximately twice, and the CVI is relatively decreased without the bolus at other respiration phases. With the bolus and expended PTV, the change in the dose distribution of the PTV is relatively small with patient respiration. Therefore, the usage of the bolus and expended PTV can be considered as one of the methods to improve the accuracy of IMRT in the treatment of breast cancer patients with respiratory motion.

A Study of The Correlation of The Area Dose with Residual CT Contrast Media and MRI Contrast Media during The Use of General Imaging Automatic Exposure Control System (일반촬영 자동노출제어장치 사용 시 잔존 CT 조영제와 MRI 조영제에 따른 면적선량의 상관성 연구)

  • Hong, Chan-Woo;Park, Jin-Hun;Lee, Jung-Min;Seo, Young-Deuk
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.619-627
    • /
    • 2016
  • The purpose of this study is to investigate the effect of CT contrast agent and MRI contrast agent on the area dose in the body when using automatic exposure control system in general radiography. After making rectangular holes in the center of the abdominal thickness paraffin phantom, CT contrast agent and MRI contrast agent were respectively diluted with physiological saline solution for contrast medium dilution ratio of 10:0, 9:1, 8:2, 7:3, 6:4, 5:5, 4:6, 3:7, 2:8, 1:9, 0:10%. Each experiment was set to 78 kVp, 320 mA, which is the proper condition for KUB photography, and thereafter a total of 30 inspections were made for each dilution ratio using an automatic exposure control device, and the area dose corresponding to the dilution ratio of each contrast agent, Average comparison and correlation analysis were performed on the exposure index. As a result, the CT contrast agent and the MRI contrast agent appeared different in area dose according to the dilution ratio(p<0.05), and as the dilution ratio increased, the area dose increased for CT contrast agent and MRI contrast agent(P<0.05). In each test, the exposure index showed the manufacturer's recommendation of 200-800 EI value, and the exposure index and area dose increased as the area dose increased(p<0.05). In conclusion, CT contrast agent and MRI contrast agent confirmed to increase the area dose by general imaging test using all automatic exposure control device. Therefore, it is considered that it is necessary to perform it after the contrast medium has been excreted sufficiently when using usual imaging test after using the contrast agent in CT and MRI examination.

Evaluation of Image Quality and dose with the Change of kVp and BMI in the Liver CT (CT 검사 시 관전압과 BMI 변화에 따른 화질 및 피폭평가)

  • Kim, Dong-Hyun;Ko, Sung-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Choi, Seok-Yoon;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.6
    • /
    • pp.331-338
    • /
    • 2013
  • CT for follow-up visits because of liver disease, body mass index (BMI) and kVp according to the change of the image quality and radiation dose to evaluate for changes. March 2010 to June 2011 at Pusan P University Hospital, abdominal CT scans a patient BMI (Body Mass Index. Less BMI) index was less than 25 in the treatment of subjects had a 48-person Noise and SNR at 100kVp abdominal image is lager than the 120kVp image. CTDI volume value at by the analysis of the radiation dose is 4.47mGy(100kVp) and 9.01mGy(120kVp). So CTDIvol in 100kVp is smaller than CTDIvol in 120kVp(decrease by 44.1%). And, effective dose is 7.1mSv(100kVp) and 12.51mSv(120kVp). So effective dose in 100kVp is smaller than effective dose in 120kVp(decrease by 43%). Evaluation of image quality is that Unacceptable 0 person, Suboptimal 0 person, Adequate 0 person, Good 1 person, Excellent 47 person. In case of repeatly patient, we examinate abdomianl CT scan by using low kVp and body mass index less than 25. We can has good quality image and benefit of low radiation dose.

Research on Image Quality and Effective dose by Exposure Index Variation (Exposure Index변화에 따른 Image Quality와 Effective dose에 대한 연구: a Monte Carlo Simulation Study)

  • Kim, Hyun Soo;Jeong, Jae Ho;Lee, Jong Woong
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.63-69
    • /
    • 2013
  • Comparing with film-screen system, flat-panel detector has extensive dynamic range. Focusing flat-panel detector, whole body human phantom PBU-50 (Kyoto, kagaku, Japan) was used to perform comparative study of the estimate of image quality and exposure dose. the exposure condition was 81kV and 20mAs, which is used for Abdomen supine exam in clinical area. As a result of the kV change of the interpreted medical image which has over 30dB of PSNR value, the value of DAP shows the difference of 19.6 times. Moreover, the result of comparing kV change with effective dose of ICRP 103 shows that stochastic effect was increased by over exposure. Therefore, it is significantly necessary that digital radiation technical chart will be used to obtain high quality image and make the standard of dose by educating radio-technologist continually.

Time Series Analysis of Gamma exposure rates in Gangneung Area (강릉 지역 공간 감마선량률의 시계열 분석)

  • Cha, Hohwan;Kim, Jaehwa
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.25-30
    • /
    • 2013
  • In this work, we investigate the statistical properties of gamma exposure rates using well-known analysis methods, such as Autocorrelation Function Analysis(ACF), Rescaled Range Analysis(R/S Analysis), and Detrended Fluctuation Analysis(DFA). Especially, DFA is an important method to reliably detect long-range correlations in non-stationary time series. Our data are measured by Gangneung regional radiation monitoring station over the period of 1998 to 2011. First, we find a crossover indicating two different governing regimes in fluctuations of gamma exposure rates. Within a year, they show a strong long-ranged memory while this property vanishes over the range of time period longer than one year. Second, our finding is very securely supported by a variety of analysis tools. Those tools yield many relevant exponents which satisfies the well known relation between them.

The Usability Evaluation Half Beam Radiation Treatment Technique on the Esophageal Cancer (식도암 환자에서의 Half Beam 치료법의 유용성 평가)

  • Park, Hochoon;Kim, Youngjae;Jang, Seongjoo
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.287-293
    • /
    • 2015
  • Because of esophageal cancer has the long length of the lesion and also inhomogeneous in depth. So, the radiation dose distribution was inhomogeneous in radiation therapy. To overcomes the dose distribution uniformity using half beam method. Patient's CT image was used radiation treatment planning. We used two planning methods that one is the using normal beam and another is using half beam. Than comparing the two radiotherapy planning using target coverage, dose volume histogram, conformity index, homogeneity index and normal tissues - heart, spinal cord, lung -. In results, Treatment planning using half beam is little more than normal beam in target coverage, dose volume histogram, conformity index, homogeneity index and normal tissues covering. However, If the patient is not correct position patients may arise a side effect. Thus, the using in Half beam involving the geometrically exact under lung cancer is considered to advantage.

A Study on the Optimization of Image Quality and Dose in Chest PA Digital Radiography (디지털 흉부 방사선 검사의 화질과 선량의 최적화에 관한 연구)

  • Park, Han Sol;Kim, Myeong Seong;Jung, Hong-Moon;Lee, Jong Woong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.55-61
    • /
    • 2017
  • There are no recommended test conditions for digital photography in Chest PA examinations. However, each company recommends shooting examinations of the high voltage applied to the previous analog examination. The condition that satisfies the value of 200 ~ 800 which is the recommended Exposure Index value recommended by Philips was selected, and the dose was evaluated by Monte Carlo simulation, and the SNR and CNR were compared. As a result, it was possible to reduce the effective dose up to 77% by controlling the tube voltage, tube current, and additional filter, not the conventional high voltage imaging method. Although there were some differences according to the test conditions, the image evaluation results were similar to the images. We will compare the exposure dose according to changes in tube voltage, tube current, and additional filter at the digital chest radiograph and evaluate the image quality of the image to propose optimal conditions.

The Evaluation of Non-Coplanar Volumetric Modulated Arc Therapy for Brain stereotactic radiosurgery (뇌 정위적 방사선수술 시 Non-Coplanar Volumetric Modulated Arc Therapy의 유용성 평가)

  • Lee, Doo Sang;Kang, Hyo Seok;Choi, Byoung Joon;Park, Sang Jun;Jung, Da Ee;Lee, Geon Ho;Ahn, Min Woo;Jeon, Myeong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.9-16
    • /
    • 2018
  • Purpose : Brain Stereotactic Radiosurgery can treat non-invasive diseases with high rates of complications due to surgical operations. However, brain stereotactic radiosurgery may be accompanied by radiation induced side effects such as fractionation radiation therapy because it uses radiation. The effects of Coplanar Volumetric Modulated Arc Therapy(C-VMAT) and Non-Coplanar Volumetric Modulated Arc Therapy(NC-VMAT) on surrounding normal tissues were analyzed in order to reduce the side effects caused fractionation radiation therapy such as head and neck. But, brain stereotactic radiosurgery these contents were not analyzed. In this study, we evaluated the usefulness of NC-VMAT by comparing and analyzing C-VMAT and NC-VMAT in patients who underwent brain stereotactic radiosurgery. Methods and materials : With C-VMAT and NC-VMAT, 13 treatment plans for brain stereotactic radiosurgery were established. The Planning Target Volume ranged from a minimum of 0.78 cc to a maximum of 12.26 cc, Prescription doses were prescribed between 15 and 24 Gy. Treatment machine was TrueBeam STx (Varian Medical Systems, USA). The energy used in the treatment plan was 6 MV Flattening Filter Free (6FFF) X-ray. The C-VMAT treatment plan used a half 2 arc or full 2 arc treatment plan, and the NC-VMAT treatment plan used 3 to 7 Arc 40 to 190 degrees. The angle of the couch was planned to be 3-7 angles. Results : The mean value of the maximum dose was $105.1{\pm}1.37%$ in C-VMAT and $105.8{\pm}1.71%$ in NC-VMAT. Conformity index of C-VMAT was $1.08{\pm}0.08$ and homogeneity index was $1.03{\pm}0.01$. Conformity index of NC-VMAT was $1.17{\pm}0.1$ and homogeneity index was $1.04{\pm}0.01$. $V_2$, $V_8$, $V_{12}$, $V_{18}$, $V_{24}$ of the brain were $176{\pm}149.36cc$, $31.50{\pm}25.03cc$, $16.53{\pm}12.63cc$, $8.60{\pm}6.87cc$ and $4.03{\pm}3.43cc$ in the C-VMAT and $135.55{\pm}115.93cc$, $24.34{\pm}17.68cc$, $14.74{\pm}10.97cc$, $8.55{\pm}6.79cc$, $4.23{\pm}3.48cc$. Conclusions : The maximum dose, conformity index, and homogeneity index showed no significant difference between C-VMAT and NC-VMAT. $V_2$ to $V_{18}$ of the brain showed a difference of at least 0.5 % to 48 %. $V_{19}$ to $V_{24}$ of the brain showed a difference of at least 0.4 % to 4.8 %. When we compare the mean value of $V_{12}$ that Radione-crosis begins to generate, NC-VMAT has about 12.2 % less amount than C-VMAT. These results suggest that if NC-VMAT is used, the volume of $V_2$ to $V_{18}$ can be reduced, which can reduce Radionecrosis.

  • PDF

Effects of Radiation Dose and Image Quality at the Coronary Angiography (관상동맥검사에서 선량과 화질에 관한 연구)

  • Ryu, Myung-Song;Choi, Nam-Gil;Han, Jae-Bok;Yang, Sook;Lee, Jong-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.4
    • /
    • pp.367-372
    • /
    • 2012
  • The aim of this study was to assess the effect of exposure factors such as kVp and mA applied by BMI on the image quality and patients absorbed dose of Coronary angiography in CT. Each data sets were into 4groups with different exposure values : Group A at 100kVp, 240mAs, Group B at 120kVp, 240mAs, Group C at 100kVp, 270mAs and Group D at 120kVp, 270mAs, and the mean of the scores of 4 groups was calculated for image quality as 4grades that is, 1(poor), 2(fair), 3(good) and 4(very good). Patient absorbed dose was calculated as DLP on the monitor. In case of absorbed dose, deviation in 2groups at 100kVp was 5.6 $mGy{\cdot}cm$, 11 $mGy{\cdot}cm$, was at 120kVp(DLP) with p<0.05. There was rather difference between groups with 100kVp or 120kVp respectively but the gaps were very little. No significant correlation was found between exposure factors and image quality in any images assessed(p>0.05), and the image quality was sufficient for diagnosis. As we applying coronary angiography, the selection of adequate exposure factors considering BMI identified might be effective for reduction of patient absorbed dose, improvement of image quality and diagnostic accuracy.

A Study of volumetric modulated arc therapy for stereotactic body radiation therapy in case of multi-target liver cancer using flattening filter free beam (다중표적 간암의 정위적체부방사선치료에서 무편평화여과기선질 용적변조회전치료의 유용성 평가)

  • Yeom, Misuk;Yoon, Inha;Hong, Donggi;Back, Geummun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.31-43
    • /
    • 2015
  • Purpose : Stereotactic body radiation therapy (SBRT) has proved its efficacy in several patient populations with primary and metastatic limited tumors. Because SBRT prescription is high dose level than Conventional radiation therapy. SBRT plan is necessary for effective Organ at risk (OAR) protection and sufficient Planning target volume (PTV) dose coverage. In particular, multi-target cases may result excessive doses to OAR and hot spot due to dose overlap. This study evaluate usefulness of Volumetric modulated arc therapy (VMAT) in dosimetric and technical considerations using Flattening filter free (FFF) beam. Materials and Methods : The treatment plans for five patients, being treated on TrueBeam STx(Varian$^{TM}$, USA) with VMAT using 10MV FFF beam and Standard conformal radiotherapy (CRT) using 15MV Flattening filter (FF) beam. PTV, liver, duodenum, bowel, spinal cord, esophagus, stomach dose were evaluated using the dose volume histogram(DVH). Conformity index(CI), homogeneity index(HI), Paddick's index(PCI) for the PTV was assessed. Total Monitor unit (MU) and beam on time was assessed. Results : Average value of CI, HI and PCI for PTV was $1.381{\pm}0.028$, $1.096{\pm}0.016$, $0.944{\pm}0.473$ in VMAT and $1.381{\pm}0.042$, $1.136{\pm}0.042$, $1.534{\pm}0.465$ in CRT respectively. OAR dose in CRT plans evaluated 1.8 times higher than VMAT. Total MU in VMAT evaluated 1.3 times increase than CRT. Average beam on time was 6.8 minute in VMAT and 21.3 minute in CRT. Conclusion : VMAT for SBRT in multi-target liver cancer using FFF beam is effective treatment techniqe in dosimetric and technical considerations. VMAT decrease intra-fraction error due to treatment time shortening using high dose rate of FFF beam.

  • PDF