• Title/Summary/Keyword: 생체역학적 평가

Search Result 74, Processing Time 0.026 seconds

Short-term Effects of Switching from Cigarette Smoking to Using Heated Tobacco Products on Cardiac Autonomic Regulation (담배 흡연에서 가열담배 사용으로의 단기간 전환에 따른 심장 자율신경 반응)

  • Dong Kyu Kim;Maeng Kyu Kim
    • Journal of Life Science
    • /
    • v.33 no.8
    • /
    • pp.639-650
    • /
    • 2023
  • The levels of harmful components in aerosols from heated tobacco products (HTPs) have been reported to be significantly lower than in cigarette smoke. However, it remains unclear whether the use of HTPs can mitigate the cardiovascular risks associated with cigarette smoking (CS). The objective of this study was to investigate the effects of a short-term switch from CS to HTP use on cardiac autonomic regulation (CAR). Seven healthy male smokers completed an open-label, randomized, cross-over trial consisting of five days of CS, use of three different HTPs (IQOS use, IQ; lil SOLID use, LS; lil HYBRID use, LH), or non-smoking (NS). Each session was separated by a one-week washout period, and levels of exhaled carbon monoxide (CO) and carboxyhemoglobin (COHb), systolic (SBP) and diastolic blood pressure (DBP), and heart rate variability (HRV) reflecting CAR were assessed before use of the product assigned to each session and at 24, 48, 72, 96, and 120 hr after use. Levels of exhaled CO and COHb were statistically significantly reduced only during NS. There were no statistical changes in SBP and DBP within any session. However, in HRV spectral analysis, log-transformed high frequency (lnHF) increased statistically significantly in IQ, LS, and NS, respectively. Normalized HF (HFnu) was significantly increased in NS and LH, respectively. lnHF and HFnu showed significant interaction effects. The findings of this study suggest that a short-term switch to HTPs instead of CS may lead to different distribution patterns of CAR, primarily driven by enhanced cardiac vagal tone.

Biomechanical Properties of the Cervical Muscles Depending on Using of a Smartphone (스마트 폰 사용에 따른 경추부 근육의 생체역학성)

  • Kim, Yong-Woo;Kim, Maeng-Kyu
    • 한국체육학회지인문사회과학편
    • /
    • v.55 no.3
    • /
    • pp.543-551
    • /
    • 2016
  • The study was aimed at investigating the relationship between biomechanical properties of cervical muscles and smartphone addiction score in fifty healthy males using smartphone more than 60 minutes each day. The usage of smartphone was evaluated by smartphone addiction survey developed from Korean International Society Agency. Biomechanical properties of three major cervical muscles; splenius capitis, sternocleidomastoid and upper trapezius, were measured by Myoton, and conducted five parameters; frequency, decrement, stiffness, creep, and relaxation time. As results, all parameters had less than 2% of coefficient of variation(CV) between measurement intervals. Also, intra-class correlation coefficient(ICC) indicated a high reliability(ICC>.9, p<.01). Moreover, the smartphone addiction score was significantly different in frequency(r=.353, p<.05) and stiffness(r=.346, p<.05) on upper trapezius; in addition, in decrement(r=-.284, p<.05) and creep(r=.288, p<.05) on sternocleidomastoid. Especially, splenius capitis was closely related with the overuse of smartphone(frequency, r=-.368, p<.01; decrement, r=-.405, p<.01; stiffness, r=-.424, p<.01). In conclusion, this study implied that the overuse of smartphone is significantly related with the damage of cervical muscles, cervical pain, and headache; furthermore, Myoton can be used as an effective device to assess mechanical properties of cervical muscles.

Mechanical Response of Changes in Design of Compression Hip Screws with Biomechanical Analysis (생체 역학적 분석에 의한 Compression Hip Screw의 디자인 요소에 대한 평가)

  • 문수정;이희성;권순영;이성재;안세영;이훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1172-1175
    • /
    • 2004
  • At present, CHS(Compression Hip Screw) is one of the best prosthesis for the intertrochanteric fracture. There is nothing to evaluate the CHS itself with the finite element analysis and mechanical tests. They have same ways of the experimental test of the ASTM standards. The purpose of this study is to evaluate the existing CHS and the new CHS which have transformational design factors with finite element analysis and mechanical tests. The mechanical tests are divided into compression tests and fatigue test for evaluating the failure load, strength and fatigue life. This finite element method is same as the experimental test of the ASTM standards. Under 300N of compression load at the lag screw head. There are less differences between Group (5H, basic type) and Group which has 8 screw holes. However, there are lots of big differences between Group and Group which is reinforced about thickness of the neck range. Moreover, the comparison of Group and Group shows similar tendency of the comparison of Group and Group . The Group is reinforced the neck range from Group. After the experimental tests and the finite element analysis, the most effective design factor of the compression hip screws is the reinforcement of the thickness, even though, there are lots of design factors. Moreover, to unite the lag screw with the plate and to analyze by static analysis, the result of this method can be used with experimental test or instead of it.

  • PDF

Bio-mechanical Analysis on the Lower Back using Human Model during Pushing the Manual Vehicles (인체모델을 이용한 농작업자의 밀기 작업시 요추부 생체 역학적 평가)

  • Lim, Dae-Seob;Lee, Kyoung-Suk;Choi, Ahn-Ryul;Kim, Young-Jin;Mun, Joung-Hwan
    • Journal of Biosystems Engineering
    • /
    • v.34 no.4
    • /
    • pp.286-294
    • /
    • 2009
  • A high prevalence of protected horticulture farmer's work-related musculo-skeletal disorders (MSDs) have been reported in precedent studies. One of the tasks required ergonomic intervention to reduce the musculo-skeletal risks is the task of product transporting. The purpose of this study is to evaluate quantitatively the spinal load of operator using manual vehicles to predict and prevent musculo-skeletal risks. Spinal load in operators using 4 kinds of manual vehicle were analyzed. Before evaluating spinal load on operator using the manual vehicles by bio-mechanical approach, it is needed to validate human model. In this study, ADAMS LifeMOD human model shows satisfactory results, comparing with already validated model's results or measured results. While Operators pushed the manual vehicles(wheelbarrow, Trolley, 2 wheel cart, and 4 wheel cart) contained loads that were 0 N and 800 N, their spinal loads(compression force, shear force) were evaluated. The compression force demonstrated under the NIOSH action limits - 3410N - for all 4 manual vehicle's operators(McGill 1997; Marras 2000). However, the lateral shear force demonstrated over the University of Waterloo - 500N - for all 3 manual vehicle's operators except 4Wheel cart (Yingline and McGill, 1999). Therefore, operators have risks in prevalence of the musculo-skeletal disorders due to shear force. The findings of this study suggest that it need to be determine the spinal load, especially lateral shear force in designing the manual vehicles in the future.

Analysis on Relation between Rehabilitation Training Movement and Muscle Activation using Weighted Association Rule Discovery (가중연관규칙 탐사를 이용한 재활훈련운동과 근육 활성의 연관성 분석)

  • Lee, Ah-Reum;Piao, Youn-Jun;Kwon, Tae-Kyu;Kim, Jung-Ja
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.46 no.6
    • /
    • pp.7-17
    • /
    • 2009
  • The precise analysis of exercise data for designing an effective rehabilitation system is very important as a feedback for planing the next exercising step. Many subjective and reliable research outcomes that were obtained by analysis and evaluation for the human motor ability by various methods of biomechanical experiments have been introduced. Most of them include quantitative analysis based on basic statistical methods, which are not practical enough for application to real clinical problems. In this situation, data mining technology can be a promising approach for clinical decision support system by discovering meaningful hidden rules and patterns from large volume of data obtained from the problem domain. In this research, in order to find relational rules between posture training type and muscle activation pattern, we investigated an application of the WAR(Weishted Association Rule) to the biomechanical data obtained mainly for evaluation of postural control ability. The discovered rules can be used as a quantitative prior knowledge for expert's decision making for rehabilitation plan. The discovered rules can be used as a more qualitative and useful priori knowledge for the rehabilitation and clinical expert's decision-making, and as a index for planning an optimal rehabilitation exercise model for a patient.

In vivo Evaluation of Osteoporotic Fracture Prevention of the site to which low Intensity Ultrasound is Irradiated using Mechanical Strength Simulations (역학적 강도 분석을 이용한 저강도 초음파의 조사 부위의 골다공증 골절 방지 효과 평가)

  • Woo, Dae-Gon;Kim, Chi-Hoon;Park, Ji-Hyung;Ko, Chang-Young;Kim, Han-Sung;Kim, Jin-Man;Kim, Sang-Hee;Lim, Do-Hyung
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.2
    • /
    • pp.135-141
    • /
    • 2009
  • Purpose: The aim of present study is to evaluate a possibility of clinical application for the effect of low intensity ultrasound stimulation (LIUS) in mechanical characteristics of bone on osteoporotic fractures prevention. Materials and Methods: Eight virgin ICR mice (14 weeks old, approximate weight 25g) were ovariectomized (OVX) to induce osteoporosis. The right hind limbs were then stimulated with LIDS (US Group), whereas left hind limbs were not stimulated (CON Group). Both hind limbs of all mice were scanned by in-vivo micro-CT to acquire two-dimensional (2D) images at 0 week before stimulation and 3 weeks and 6 weeks after stimulation. Three-dimensional (3D) finite element (FE) models generated by scanned 2D images were used to determine quantitatively the effect of LIUS on strength related to bone structure. Additionally, distributions of Hounsfield units and elastic moduli, which are related to the bone quality, for the bones in the US and CON groups were determined to analyze quantitatively a degree of improvement of bone qualities achieved by LIUS. Results: The result of FE analysis showed that the structural strength in US Group was significantly increased over time (p<0.05), while that in CON Group was statistically constant over time (p>0.05). High values of Hounsfield units obtained from voxels on micro-CT images and high values of elastic moduli converted from the Hounsfield units were dominantly appeared in US Group compared with those in CON Group. Conclusion: These finding indicated that LIUS would improve the mechanical characteristics of osteoporotic bone via the effects of bone structure (bone strength) and quality (Hounsfield unit and elastic modulus). Therefore, the LIUS may decrease effectively the risk of osteoporotic fracture in clinics.

Assessment of Hemodynamic Properties of Trileaflet Polymer Heart Valve Manufactured By Vacuum Forming Process (진공성형을 이용한 삼엽식 고분자 심장판막의 제작과 혈류역학적 성능평가)

  • Kim, K.H.;Hwang, C.M.;Jeong, G.S.;Ahn, C.B.;Kim, B.S.;Lee, J.J.;Nam, K.W.;Sun, K.
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.6
    • /
    • pp.418-426
    • /
    • 2006
  • In the artificial heart application, productivity and hemodynamic properties of artificial heart valves are crucial in successiful application to long term in vivo trials. This paper is about manufacture and assessment of trileaflet polymer heart valves using vacuum forming process(VFP). The VFP has many advantages such as reduced fabrication time, reproducibility due to relatively easy and simple process for manufacturing. Prior to VFP of trileaflet polymer heart valves, polyurethane(Pellethane 2363 80AE, Dow Chemical) sheet was prepared by extrusion. The sheets were heated and formed to mold shape by vacuum pressure. The vacuum formed trileaflet polymer heart valves fabrication is composed of two step method, first, leaflet forming and second, conduit forming. This two-step forming process made the leaflet-conduit bonding stable with any organic solvents. Hydrodynamic properties and hemocompatibility of the vacuum formed trileaflet polymer heart valves was compared with sorin bicarbon bileaflet heart valve. The percent effective orifice area of vacuum formed trileaflet polymer heart valves was inferior to bileaflet heart valve, but the increase of plasma free hemoglobin level which reflect blood damage was superior in vacuum formed trileaflet polymer heart valves Vacuum formed trileaflet polymer heart valves has high productivity, and superior hemodynamic property than bileaflet heart valves. Low manufacturing cost and blood compatible trileaflet polymer heart valves shows the advantages of vacuum forming process, and these results give feasibility in in vivo animal trials in near future, and the clinical artificial heart development program.

Biomechanical Evaluation for Washing Machine Design Suggested Newly for Prevention of Musculoskeletal Disorders (근골격계 질환 예방을 위하여 새로이 제시된 세탁기 디자인에 대한 생체역학적 평가)

  • Cho, Young-Kuen;Choi, Hue-Seok;Kim, Hyun-Dong;Choi, Hyun-Ho;Youn, Join-In;Kim, Young-Ho;Shin, Tae-Min;Kim, Han-Sung;Lim, Do-Hyung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.27 no.4
    • /
    • pp.27-35
    • /
    • 2008
  • Recently, many studies have reported the fact that an excessively accumulated psychological and physical burden induced from physical labor conducted routinely in home and industry can be one of main reasons of musculoskeletal disorders in the working population. This fact makes increase interests in studies to reduce a risk of musculoskeletal disorders through grafting ergonomic considerations on working environment. However, there are currently limited methodologies in quantitative evaluations of new ergonomic suggestions to reduce a risk of musculoskeletal disorders. The current study is therefore performed to evaluate quantitatively effects of a design of washing machine as a new ergonomic suggestion onto prevention of musculoskeletal disorders, through application of a biomechanical evaluation methodology. For this, three-dimensional motion analysis by using musculoskeletal models with Rapid Entire Body Assessment (REBA), which has been generally used for a simple evaluation of a degree of harmfulness of the human body at specific working postures to be considered, was performed. The results of REBA did not give us enough information and their results were somewhat simple and inaccurate, but the results of the three-dimensional motion analysis give us enough information such as alteration of main muscle forces and joint moments required during washing work. All results showed that the main muscle strengths and joint moments were decreased effectively for reduction of a risk of musculoskeletal disorders during the washing work with newly designed washing machine evaluated in the current study, compared with those generated during the washing work with general washing machine. From these results, it can be concluded that a risk of the musculoskeletal disorders, which may be induced by a repetitive washing work, may be reduced through using the washing machine designed ergonomically and newly. Also, it is thought that if our ergonomic design can be applied for improvement of working environment in lifting and laying works conducted repeatedly for a treatment work of goods, which have a strong resemblance to the behaviors generated frequently during the washing work, a possibility of occurrence of the musculoskeletal disorders by the lifting and laying works may be reduced highly.

Evaluation of Bio-Mechanical Character istics According to Loading Deviation Methods dur ing Rowing Exercise (로잉운동의 부하편차 방식 적용에 따른 상하지 생체 역학적 평가)

  • Kang, Seung-Rok;Jung, Gu-Young;Moon, Dong-An;Jeong, Jang-Sik;Kim, Jung-Ja;Kwon, Tae-Kyu
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.3
    • /
    • pp.369-382
    • /
    • 2011
  • The purpose of this study was to verify the validation of exercise effect with loading deviation during rowing exercise. We performed evaluation of based physical fitness and joint torque before the experiment for finding muscle unbalance. So we recruited twenty four subjects who have bigger muscle strength in more 20% than average one. Subjects divided two groups. One is dominant upper limbs(DU) and the other was dominant lower limbs(DL). Subjects performed rowing exercise using electric equipment (Robo.gym.Humonic.korea). Exercise is performed four sets a day including 25 times a set, and three days a week. Measurement consist of evaluation of based physical fitness and joint torque using biodex(biodex system3.USA). Evaluation of exercise effect performed each week in joint torque of shoulder, lumbar and knee joint and each month in based physical fitness. Also we adapted 30% of 1RM for muscular endurance and 70% of 1RM for muscle strength as exercise load. The results showed that the difference of maximal peak torque were getting increase significantly during exercise. Also difference of various factor in based physical fitness were getting increase significantly except flexibility and agility. This interpreted that rowing exercise with loading deviation types could provide muscle strength and muscular endurance exercise in same time. These results could be interpret to two ways. One is effect of improving physical fitness for rowing exercise and the other meaned validation of loading deviation in rowing exercise. Our study is going to verify the validation of loading deviation during rowing and we found out that loading deviation could provide muscle strength and muscular endurance exercise for improving muscle unbalance. Our study can be used development of exercise equipment and program for normal people with muscle unbalance. Also that provide effect of whole body exercise to anybody.

Evaluation of Insole-equipped Ankle Foot Or thosis for Effect on Gait based on Biomechanical Analysis (인솔 장착형 단하지 보조기의 생체 역학적 분석을 통한 보행 영향성 평가)

  • Jung, Ji-Yong;Kim, Jin-Ho;Kim, Kyung;Trieu, Pham Hai;Won, Yong-Gwan;Kwon, Dae-Kyu;Kim, Jung-Ja
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.4
    • /
    • pp.469-477
    • /
    • 2010
  • The purpose of this study was to evaluate the effects of insole-equipped ankle-foot-orthoses (AFO) on gait. 10 healthy males who had no history of injury in the lower extremity participated in this study as the subjects. The foot of each subject was first scanned, and the insole fit to the plantar was made using BDI-PCO(Pedcad Gmbh, Germany). The subject then was made to walk on a treadmill under four experimental conditions: 1) normal walking, 2) walking wearing AFO, 3) walking wearing AFO equipped with the insole, 4) walking wearing pneumatic-ankle-foot-orthosis (pAFO) equipped with the insole. During walking, foot pressure data such as maximum force, contacting area, peak pressure, and mean pressure was collected using Pedar-X system (Novel Gmbh, Germany) and EMG activity of lower limb muscles such as gastrocnemius medial head, gastrocnemius lateral head, and soleus was recorded using MP150 EMG module (BIOPAC System Inc., USA). Collected data was then analyzed using paired t-test in order to investigate the effects of the insole. As a result of the analysis, when insole was equipped, overall contacting area was increased while both the highest peak pressure and the mean pressure were significantly decreased, and EMG activity of the lower limb muscles was decreased. On the contrary, the cases of wearing AFO showed the decreased contacting area and the increased pressures. Therefore, the AFO equipped with a proper insole fit well to the foot can help comfortable walking by spreading the pressure over the entire plantar.