• Title/Summary/Keyword: 색조측정기

Search Result 8, Processing Time 0.025 seconds

Comparison of Shade Changes According to Dry/Wet Condition of Tooth using Intra-Oral Colorimeter (건조정도에 따른 자연치아의 색조비교)

  • Choi, Mee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.265-271
    • /
    • 2010
  • One of the most important aspect of esthetic dentistry is shade selection. Alterations to perception of color can occur as a result of numerous factors, including light source, tooth surface texture, observer's ability, surrounding colors, the angle of observation, light and dark adaptation and others. During the clinical procedures, tooth might be in dry or semi-dry condition. The purpose of this study was to compare the shade changes in wet and dry conditions of natural tooth. Groups of measurement are an initial wet condition as control, dry in 10seconds, 1 minute, 5minutes and 30seconds air dry. Using Shadeeye, color difference(${\Delta}E$) between measurements were analyzed and there were significant differences between groups. But most of the differneces were <3.7 ${\Delta}E$ unit. Such differences are below the threshold for perceivable color mismathces in intraoral condition. Shade selection with an intraoral colorimeter could be changes in dry and wet condition but there might be no significant differences in visual color mathing.

Shade comparative analysis of natural tooth measured by visual and spectrophotometric methods (육안과 분광 측정기를 이용한 자연 치아의 색조비교분석)

  • Kim, Bum-Suk;Shin, Soo-Yeon;Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.443-454
    • /
    • 2008
  • Statement of problem: A clinically successful color match is one of the important factor to get an esthetic dental restoration. Dental shade guides are commonly used to evaluate tooth color in restorative procedure. But numerous reports have indicated that common shade guides do not provide sufficient spectral coverage of the natural tooth colors. To address issues associated with the shade guide, distinct avenues have been pursued objective spectrophotometric / colorimetric assessment. Purpose: This study compared the accuracy of tooth color selection of spectrophotometer with that of human visual determination. Three main factors were investigated, namely, the effect of light, the individual variation and the experience of the observer. Material and methods: At the first experiment, on ten patients, one operator independently selected the best matching shade to the unrestored maxillary central incisor, using a Vita Classical Shade Guide in the morning, at noon and in the afternoon. The same teeth were measured by means of a reflectance spectrophotometer. At the second experiment, on ten patients, ten operators (5 experts, 5 novices) selected and measured by the same method above at noon. At the third experiment, the results of the second experiment were divided into two groups, expert and novice, and analyzed. Results: 1. There was significant difference between visual and spectrophotometric assessment (mean ${\Delta}E$ values) in experiment 1, 2, 3 (P < .05). 2. There was no significant difference between experts and novices group, when comparing with each visual and spectrophotometric assessment (mean ${\Delta}E$ values). Conclusion: Spectrophotometer could be used to analyze the shade of natural tooth objectively. Thereby, this method offers the potential tominimize considerably the need for corrections or even remakesafter intraoral try-in of restoration. Furthermore, to achieve its advantage, both the shade-matching environment and communication between dentist and technician should be optimized with use of visual and instrumental shade-matching systems.

미쓰비시의 MCCS측정기, 품질표준화를 위한 과정

  • Korean Printers Association
    • 프린팅코리아
    • /
    • v.7 no.9
    • /
    • pp.113-113
    • /
    • 2008
  • PPC 서버는 CIP3/4에 따른 프리프레스장비에 의해 생성된 미리보기 이미지를 통하여 회선율을 산출 및 인쇄조건 데이터를 변환하여 IPC로 전송하고 전송된 데이터는 IPC를 통해 인쇄기에 잉크키 등을 미리설정(프리셋)한다. 인쇄되는 인쇄물의 잉크 키 데이터와 화선율의 데이터를 MCCS(색조관리장치)로 보내고 MCCS에서는 인쇄된 칼라 패치를 분광계로 계측하고, 그 결과를 화면에 표시한다. MCCS는 목표치에 대하여 계측치의 차이를 기준으로 목표치에 가깝게 되도록 잉크키 개도를 조절해 피드백하며, IPC EXPERT 기능용 계측 데이터를 IPC로 보낸다. 따라서, 사람의 눈으로 관리하는 컬러매니지먼트(CMS가 아닌 CIP3/4 데이터의 화선율과 인쇄조건을 PPC서버가 변환하여 IPC에 전송하는 것이다. 인쇄한 인쇄결과물을 MCCS로 계측하여 항상 기준목표 농도치에 맞게 기계에 피드백하고 잉크키 개도를 조절, 색조관리를 함으로써 일정한 품질유지 및 농도관리를 가능(손지절감 및 색조관리의 일관성)하게 하는 시스템이다.

  • PDF

Power density of light curing units through resin inlays fabricated with direct and indirect composites (직접수복용 레진과 기공용 레진으로 제작한 레진 인레이를 투과한 광중합기의 광강도)

  • Chang, Hoon-Sang;Lim, Young-Jun;Kim, Jeong-Mi;Hong, Sung-Ok
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.5
    • /
    • pp.353-358
    • /
    • 2010
  • Objectives: The purpose of this study was to measure the power density of light curing units transmitted through resin inlays fabricated with direct composite (Filtek Z350, Filtek Supreme XT) and indirect composite (Sinfony). Materials and Methods: A3 shade of Z350, A3B and A3E shades of Supreme XT, and A3, E3, and T1 shades of Sinfony were used to fabricate the resin inlays in 1.5 mm thickness. The power density of a halogen light curing unit (Optilux 360) and an LED light curing unit (Elipar S10) through the fabricated resin inlays was measured with a hand held dental radiometer (Cure Rite). To investigate the effect of each composite layer consisting the resin inlays on light transmission, resin specimens of each shade were fabricated in 0.5 mm thickness and power density was measured through the resin specimens. Results: The power density through the resin inlays was lowest with the Z350 A3, followed by Supreme XT A3B and A3E. The power density was highest with Sinfony A3, E3, and T1 (p < 0.05). The power density through 0.5 mm thick resin specimens was lowest with dentin shades, Sinfony A3, Z350 A3, Supreme XT A3B, followed by enamel shades, Supreme XT A3E and Sinfony E3. The power density was highest with translucent shade, Sinfony T1 (p < 0.05). Conclusions: Using indirect lab composites with dentin, enamel, and translucent shades rather than direct composites with one or two shades could be advantageous in transmitting curing lights through resin inlays.

Shade Comparative Analysis of Natural Tooth using Spectrophotometric Methods (분광측정기를 이용한 자연 치아의 색조 비교 분석)

  • Kim, Sa-Hak;Hwang, Seong-Sig;Lee, Hye-Eun
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.2
    • /
    • pp.772-781
    • /
    • 2016
  • This study is to set the objective criteria on maxillary incisors shade selection by using the colorimetric Shade-Eye NCC as measuring in CIE $L^*$, $a^*$, $b^*$ values, and look into the meaning by analyzing its values. We explain the purpose of this study and gotten their agreement from patients visiting the dentist, 111 people's (men 50, women 61) three teeth, the maxillary central incisor, maxillary lateral incisor, maxillary canines, total of 333 teeth colorimetry. As a result of comparing the differences in colors between cervical margin and incisal edge, ${\Delta}E^*$ of canine is shown as low as $5.81({\pm}2.98)$, followed by lateral incisor of maxilla as $6.51({\pm}3.23)$ and central incisor of maxilla $7.51({\pm}3.04)$. Females show higher luminosity(L*) than males do in all teeth- central incisor, lateral incisor and canine; in yello chroma(b*) males' central incisor is slightly higher than that of females (p<0.05). Age significantly influences the luminosity and red (a*) and yellow chroma (b*) of central incisor(L*); the luminosity(L*), and yellow chroma(b*) of lateral incisor and canine (p<0.05). Smoking doesn't significantly influence the color of natural teeth. Drinking reduces the luminosity of central incisor as well as red chroma of lateral incisor(p<0.05). A chronic illness is likely to reduce the luminosity of central incisor and lateral incisor(p<0.05).

Study of the Tone Variation on Juniperus chinensis L. and Populus glandulosa Uyeki by Photographs (사진상(寫眞上)에 나타난 향나무(Juniperus chinensis L.)와 수원사시나무(Populus glandulosa Uyeki)의 색조변화(色調變化)에 관(關)한 연구(硏究))

  • Kim, Kap Duk
    • Journal of Korean Society of Forest Science
    • /
    • v.13 no.1
    • /
    • pp.1-24
    • /
    • 1971
  • In order to elucidate the feasibility to identify the plant species through the photographic tone this study was made. In this study the author made photographs of Juniperus chinensis L., and Populus glandulosa Uyeki, with the panchromatic film using either yellow filter or red filter in different seasons respectively. The author analyzed the value of tone variation at the level of stereoscopic view of the same photographs by using tone scale and Automatic Micro-Photo-Densitometer. The results obtained are summarized as follows: A. Tone scale reading 1. The tone of Populus glandulosa Uyeki was darker than that of Juniperus chinensis L. in a photograph. 2. Regardless of the tree species, tone of photographs obtained with yellow filter was darker than that with red filter. 3. Along the progresses of seasons, the photographic tone was changed. That is, from the spring to the summer it showed darker and than, from the summer to winter it changed lighter. 4. During winter and spring the discrimination between the both species of trees can be easily made by stereoscopic view whether there are leaves on the tree or not rather than by tone observation. 5. Regardless of tree species, variation of tone due to the age was noticed. The older trees have darker tone than the younger one. 6. It is recognized that the yearly difference depends on insolation quantities. 7. The highest reflex light-waves were in between $600m{\mu}$ and $660m{\mu}$ for both species of trees. B. Density reading 1. For the density reading, there was the same tendency as in tone scale reading. 2. The changes of peaks of the scanning curves with Populus glandulosa Uyeki is smoother and takes place in lower position than with Juniperus chinensis L. 3. The scanning curves on the 20th May was smoothest, and change of peaks increased gradually according to the season progresses. 4. In relation to the types of filter the photographs with yellow filter showed less changes of peaks then that with red filter.

  • PDF

The survey on the infection control of noncritical instruments used in dental treatment (치과 치료에 사용되는 비위험 기구의 감염 관리 실태 조사)

  • Kim, Jae Hyun;Lee, Jin-Han
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.1
    • /
    • pp.27-36
    • /
    • 2019
  • Purpose: The aims of this study were to evaluate the dentist's awareness and the actual status of infection control of noncritical dental instruments. Materials and Methods: 40 dental clinics in Daejeon, South Chungcheong, North Chungcheong and North Jeolla provinces were surveyed. The questionnaire was delivered to the dentists belonging to those clinics, and the awareness and the practice of infection control were examined. The microbial contamination on the surface of five noncritical instruments (impression gun, light curing unit, 3-way syringe, shade guide, and dental floss dispenser) used by them was measured with an ATP luminometer. Correlation analysis between the awareness and the actual state of infection control was conducted. Results: Awareness and frequency of infection control was highest in the 3-way syringe. Surface disinfection using disinfectant was most frequent in all instruments. 3-way syringes and shade guides were less contaminated than impression guns, light curing units, and dental floss dispensers. Conclusion: 3-way syringes had a significant correlation between user awareness of infection control and surface contamination, and the higher awareness, the lower the contamination measurement was shown.

REMINERALIZATION EFFECT OF SODIUM FLUORIDE VARNISH ON WHITE LESION BY APPLICATION INTERVALS (불화나트륨 바니쉬의 도포 주기에 따른 백색 병소의 재광화 효과)

  • Lee, Eun-Hui;Kim, Jong-Soo;Yoo, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.4
    • /
    • pp.403-411
    • /
    • 2010
  • This study is about the treatment effect of fluoride varnish on white lesion. The changes in microhardness values and lesion sizes were compared and analyzed in relation to application interval, frequency, etc. Resin blocks were fabricated with the crown portion of permanent molars. Samples were classified into group I(1 week), group II(2 weeks) and group III(3 weeks) based on fluoride application intervals, each with 15 samples. Samples were soaked into a decalcifying solution for 15 days, and stored in artificial saliva at $37^{\circ}C$ thermostat. The changes in microhardness values and lesion sizes, before/after decalcification and after fluoride application, were evaluated. The following results were obtained. 1. Microhardness values in group II and III exhibited almost twice the increasing rate than group I. There were significant differences between group I and II, and group I and III (p<0.05), but none between group II and III (p>0.05). 2. Change in lesion sizes showed no significant differences between group I and II, III (p>0.05). In conclusion, fluoride varnish application results in both qualitative and quantitative improvements in white lesions. The satisfactory results can be obtained when varnish is applied at more than 2 weeks interval.