Analysis of Earthquake Countermeasure for Electrical Facility Building on Domestic and Foreign (국내외 건축물에 시설되는 수변전설비 지진 대책에 관한 조사 분석)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Bae, Suk-Myong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.150-156
    • /
    • 2008
  • Recently life and properties damage at Japan and China by generating earthquake. For establishing measure for earthquake in domestic, earthquake disaster measure law was enacted on March, 2008 from a natural disaster of earthquake and present the detail part and enforce the measures. This paper analyzes domestic site and problems of electrical facility earthquake measures at transformer vault which the power supply the emergence situation at generating earthquake. Also we present the domestic seismic design and construction direction from research and analysis related law and regulation for the seismic design and construction in domestic and foreign for electrical facility. Afterward we will need to study reliability inspection for electrical facility seismic design method and construction at buildings transformer vault.

Surge Protection Method of the Underground Distribution System in Korea (국내 지중배전시스템의 서어지 보호방안)

  • Lee, Jae-Bong;Jung, Yeon-Ha;Park, Chul-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.84-88
    • /
    • 2008
  • This paper deals with the part of the surge protection method of the underground distribution system in Korea using arrestors by simulating with ATP-EMTP(Electro-Magnetic Transient Program) based on the "A Study on the Surge Propagation Property of Underground Distribution Cables by Field Tests" which was published in 2007. Although domestic underground distribution system is protected by arrester which installed at a riser pole, we need to additional protection method because lightning surge can be doubled and affect underground distribution facilities when it is injected into the mixed distribution line of overhead and underground through a riser pole. In this paper, it is proposed that scout method that arresters are attached to the sides of a riser pole is better than developing of a elbow arrester on a viewpoint of economics and maintenance, because of the situation of the domestic underground distribution system.

A Study on Fault Model end Performance Evaluation under Power Switch Open Fault in an Inverter-Driven Permanent Magnets Synchronous Motor (영구자석 동기전동기 구동 인버터 스위치의 개방 고장에 의한 제어 특성해석 및 고장모델 연구)

  • Kim, Kyeong-Hwa;Choi, Dong-Uk;Gu, Bon-Gwan;Jung, In-Soung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.6
    • /
    • pp.40-51
    • /
    • 2009
  • To analyze influences under open faults in switching devices of the PWM inverter and under the isolation between the inverter and motor terminal, a faulty model for the inverter-driven permanent magnet synchronous motor is presented. Even though the conventional dq motor model obtained through the transformation of phase voltage model is widely used to analyze and control AC motor, it can not be used under open faults in switching devices since the 3-phase balanced condition is no longer hold under the open fault and it is not easy to obtain motor input voltages in open phase from the pole voltage. To deal with this problem, a faulty model for an inverter-driven permanent magnet synchronous motor is derived by using the line voltage of motor according to switch open, which can be effectively used for performance evaluation of the diagnostic algorithm. The validity of the proposed faulty model is verified through comparative simulations and experiments using DSP TMS320F28335.

A Sensor Value Validation Technique for Supporting Stable Operations of Thermal Power Plants (화력발전소의 안정운전 지원을 위한 계측값 검증 기법에 관한 연구)

  • Lee, Seung-Chul;Kim, Seung-Jin;Han, Seung-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.201-209
    • /
    • 2009
  • In power plant operations, sensor values often exhibit erroneous values due to their failures or the intrusions of various noises. However, most of the power plant monitoring and fault diagnosis systems perform their tasks based on the assumptions that the collected sensor values are correct all the times. These assumptions, which are not valid, often lead to serious consequences such as power plant trips. In this paper, we propose a power plant sensor value validation technique that can utilize the relationships existing among the sensor values as the sensor redundancy. The proposed technique is applied to the flow meters installed along boiler feed water systems of a typical tubular type boiler thermal power plant and shows a good potential of future applications.

A Characteristic Study on the Power Factor Correction Application for Induction Motor (유도전동기에 대한 역률 보상설비의 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.25-31
    • /
    • 2008
  • The field of induction motor is magnetized and demagnetized for each reversal of the current. This field component of the motor accounts for most of the reactive component of inductive load. Reactive power needs to sustain the electromagnetic field required for the induction motor to operate. Power factor of induction motor is usually low and power factor correction needs. Power factor becomes low by the effect of the reduction operation of load capacity. In most cases, Capacitor capacity for the power factor correction should be complied with the recommendation by the motor capacity. But Capacitor value for power factor correction can't change during the normal operation. In this paper, we analyzed characteristics of power and power factor changing by load fluctuation of low-voltage small size induction motor and show that lower power factor correction's parameter of existing recommendation should be revised by new value.

Dynamic Traffic Information Provision and Dismissal Strategy for Before and After Traffic Incident (교통사고 전후 동적 정보 제공 및 해제 전략)

  • Jeon, Gyo-Seok;Kim, Tae-Wan;Lee, Hyun-Mi;Jang, Jeong-Ah
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.5
    • /
    • pp.867-878
    • /
    • 2021
  • Recently, there has been active research on smart street lamps that can collect real-time traffic data and provide traffic information by attaching images and radars to road lighting facilities. Smart street light technology can detect, identify, and provide dense information compared to existing technologies. In order to effectively utilize the smart streetlight as a high-resolution information delivery medium, a branch-type operation strategy that is different from the existing centralized operation strategy is required. This study presents dynamic information delivery strategies, release strategies, and their criteria for various purposes in a spatial range, separated by the context before and after the occurrence of smart street lights-based accidents. Through this, it is expected that smart road lighting facilities can be used more effectively.

Design and Implementation of Convenience System Based on IoT (IoT를 기반한 편의 시스템 설계 및 구현)

  • Ui-Do Kim;Seung-Jin Yu;Jae-Won Lee;Seok-Tae Cho;Jae-Wook Kim
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.19 no.1
    • /
    • pp.165-172
    • /
    • 2024
  • In this paper, we designed a smart home system that can be used intuitively and easily in everyday life, such as sending text messages to users, providing various information and scheduling using smart AI, and providing lighting and atmosphere suitable for the atmosphere in situations such as listening to music using neopixels, as well as using ESP32, RFID, and Google Cloude Console using raspberry pie. As a result of the experiment, it was confirmed that security characters were normally sent to users when RFID was recognized on ESP32 connected to Wi-Fi even if the power was reconnected, and smart AI using Neopixel lighting, Raspberry Pie, and voice recognition, which calculated frequency, also changed the recognition rate over distance, but it worked.

Constructing the Forest Fire Extinguishment Helicopter Management System by Integrating GPS and GIS (GPS와 GIS를 통합한 산불진화 헬기 관리시스템 구축)

  • Jo, Myung-Hee;Kim, Joon-Bum;Jo, Yun-Won;Shin, Dong-Ho
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.6 no.1
    • /
    • pp.48-58
    • /
    • 2003
  • Recently in order to extinguish the large scale of forest fire efficiently and rapidly the forest fire extinguishment equipment such as helicopters and vehicles has been mobilized. In this situation, the most consideration for the effective extinguishment is to understand the forest fire surrounding area and situation very well and arrange and manage the extinguishment equipment timely. In this paper, the client/serve-based forest fire extinguishment helicopter management system was constructed by integrating GPS(global positioning system) and GIS(geographic information system) technologies. This system manages and considers not only extinguishment equipment information such as helicopters and vehicles including manpower arrangement but also extinguishment environment information such as storing reservoir status and road situation and so on. For this, the real time tracking of helicopter location was first acquired through GPS technology then all the information about forest fire surrounding area was offered through the user-friendly interface of GIS concept. The result of constructing this system helps to extinguish a large scale of forest fire rapidly and effectively within shorter time then reduces physical damage and much manpower mobilization.

  • PDF

A Methodology Development for Estimating the Retroreflectivity of Pavement Markings and Traffic Guide Signs Using Digital Images (디지털 이미지를 이용한 노면표시 및 교통안내표지의 재귀반사 성능 평가 방법론 개발)

  • Choi, Keechoo;Lee, Seunghyeon;Yun, Ilsoo;Yi, Yongju
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.1
    • /
    • pp.185-194
    • /
    • 2014
  • This study investigates the methodology to evaluate the quantified performance of pavement markings and traffic guide signs using digital images. This methodology is significant to attempt to quantify their performance without large brightness photometer at the nighttime and bad weather. The retroreflective performance of pavement markings are evaluated through the contrast of gray levels of pavements and markings in collected digital images under the case of rain, dampness, and dryness. In addition, the appraisal of retroreflective performance of traffic guide signs are implemented through the comparison between interior illuminated and the existing retroreflective traffic guide signs using the contrast of luminance extracted from the value of RGB of backgrounds and legends in collected digital images according to geometric design, driving lanes, and the distance between the car and the sign. As a result, the retroreflective performance of pavement markings deteriorates about 3.5 times and 2 times under the case of rain and dampness respectively than dryness. Also, the performance of the existing traffic guide signs is significantly influenced by geometric design, driving lanes, and the distance, otherwise interior illuminated traffic guide signs. This methodology can be utilized to construct objective information of performance of traffic safety facilities to select appropriate position of expensive high reflective pavement markings and interior illuminated traffic guide signs considering diverse weather and geometric design.

The Developed Study for SMPS to Protect the Noise and Inrush Current at LED Lighting Source (LED 광원에서 잡음 및 돌입전류 방지를 위한 스위칭모드 전원공급 장치 (SMPS) 개발 연구)

  • Chung, Chansoo;Hong, Gyujang;We, Sungbok;Yu, Geonsu;Kim, Mijin
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.4
    • /
    • pp.577-582
    • /
    • 2016
  • This Study focused on the development of SMPS (Switching Mode Power Supply) to supply the constant votage and current nevertheless LED fluorescent Light generated the electric noise (with Harmonics) and Inrush current at instant time of turn-on and off. Recently, according to the Green policy in government, the LED fluorescent Lighter showed the rapidly increasing tend as indoor and outdoor Lighter. But, because of costs, LED fluorescent Light not considered and neglected the following items; power factor, efficiency, Harmonics and Inrush current. So, we are developed the SMPS about 3 key issues as follows: 1st, power factor and efficiency is 85%. 2nd, the switching noisy by harmonic is minimized. 3rd, the Inrush current at turn on and off time is reduced the minimum 0.3 A after $100{\mu}sec$ on turnon time. The proposed SMPS adjusted by LNK 409 driver (included the high frequency modulation function). Although, the developed SMPS maintained the about 85% of power factor and efficiency. but, the SMPS must be generated low heat by the variation of minute load current at switching timing. To improve the above weak point, the developed SMPS have the feedback monitoring circuit between input side and output side to maintain the power factor and efficiency. Also, we are studied the time-constant of control circuit to output the constant voltage and current nevertheless the load disturbance of LED lighting. The LED fluorescent Light of 46W is checked the above items.