• Title/Summary/Keyword: 상하 직경

Search Result 719, Processing Time 0.032 seconds

Normal Glenoid Size of the Korean in 7th and 8th Decades (한국인 60~70대의 정상 견갑골 관절와의 크기)

  • Moon, Young-Lae;Ha, Sang-Ho;Noh, Kyung-Hwan
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.1
    • /
    • pp.37-40
    • /
    • 2008
  • Purpose: We wanted to evaluate the normal glenoid size of Koreans in their 7th and 8th decades by conducting Computed tomographic (CT) studies. Materials and Methods: The CT images were obtained from the normal scapulae of the patients (mean age: 68.8) who had humeral fracture. A display workstation version 2.0.73.315 was used to measure the scans to determine the maximal superoinferior (SI) and anteroposterior (AP) diameters of the glenoid vault. Results: The average diameters of curvature of the glenoid were 31.2 mm (range: 27 to 34 mm) in the superior-inferior direction and 26.1mm (range: 22 to 31mm) in the anterior-posterior direction. Conclusion: This study showed the normal glenoid size of Koreans and it is different from the size that the international literature reported. It should be an important factor for the treatment of fracture or in designing arthroplasty implants.

Relationships between Airborne Droplet and Impression Diameters in Small Droplets (작은 분무입자(噴霧粒子)에 있어서 원형분무입자(原形噴霧粒子) 직경(直徑)과 살포(撒布)된 입자직경(粒子直徑)의 관계(關係))

  • Lee, Sang-Woo
    • Korean Journal of Agricultural Science
    • /
    • v.6 no.2
    • /
    • pp.192-197
    • /
    • 1979
  • Spread factors were tried to determine the diameter of airborne droplet emitted: from the sprayer by the measurements of airborne droplet diameter emitted from the uniform size droplet producer and impression diameter on Kromekote card or Eucalypt's leaf in the different dilute concentration with Geigy Red Herbicide Dye from 0.5% to 2% by weight. The results abtained were as follows; The general form of the equation in the relationship between airborne droplet and impression diameter on Kromekote card or Eucalypt's leaf was an exponential equation as follows; $$Y=aX^b$$ which gave a linear relation on log-log graph paper. The spread factor seemed to be larger in the thin dilute concentration than in the thick dilute concentration. The spread factor was remarkably smaller on Eucalypt's leaf than on Kromekote card due to the penetration of liquid into the leaf and the stomata of the epidermis. The calculated equation of the mean depth of the droplet sprayed on Eucalypt's leaf was the same form as $Y=aX^b$, which implied that the spray liquid was distributed in surplus in accordance with the diameter of the droplet larger than the optimum size droplet to control insect and disease.

  • PDF

Study on the Energy Separation Characteristics of the $100Nm^3$/hr Level Vortex Tube ($100Nm^3$/hr급 볼텍스튜브의 온도 분리 특성 연구)

  • Kim, Chang-Su;Park, Sung-Young
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05b
    • /
    • pp.996-999
    • /
    • 2010
  • 고압의 가스를 이용하여 고온 가스와 저온 가스를 분리하거나 입자상 물질의 분리에 사용할 수 있는 장치인 볼텍스 튜브의 에너지 분리 특성을 파악하기 위하여 $100Nm^3$/hr급 볼텍스 튜브를 제작하고 이에 대한 실험을 진행하였다. 저온측의 유량비와 오리피스 직경 및 볼텍스 튜브의 길이가 온도에 미치는 영향을 분석하였다. 오리피스 직경 0.6D에서 최적의 온도 분리 효과를 나타내었으며, 0.8D의 경우 그 효과가 미미하였다. 또 한 오리피스 직경이나 길이에 관계없이 저온유량비가 약 0.9부근에서 고온측의 온도가 최고점을 나타내었고, 볼텍스 튜브 길이는 저온측 온도 변화에 미미한 영향을 미치나, 오리피스 직경의 변화는 최저 온도점이 나타나는 저온 유량비에 상당한 영향을 미쳤다. 본 연구의 결과는 $100Nm^3$/hr급 볼텍스 튜브의 최적화를 위한 기초자료로 활용될 수 있을 것이다.

  • PDF

Application of CFD model for the design of multi-layer settling basin structure (이층 침전지 설계를 위한 CFD모형의 적용)

  • Yu, Chang-Hwan;Kim, Tae-Won;Kim, Nam-Il;Lee, Kil-Seoung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1677-1680
    • /
    • 2006
  • 하수처리장의 침전지 구조물은 고형물(SS) 및 현탁물을 침전, 제거하여 하수의 정화를 도모하는 시설로 초기 유입 하수의 생물학적 처리로 인해 발생되는 슬러지와 처리수를 분리함에 그 목적을 두고 있다. 침전지 구조물은 장소의 제약 및 침전지의 효율성 측면에서 많은 공법이 제안되고 있으며, 그중 이층 침전지의 경우 구조물의 시공비용 절감 및 공간 활용측면에서 단층 침전지에 비해 우수성을 인정받고 있다. 하지만 상 하 층에 위치하고 있는 침전지 유입부의 위치적 특성으로 인해 균등한 유량의 분배가 이루어지지 않고 유량이 한곳에 집중되는 현상으로 보일 수 있다. 본 연구에서는 3차원 수치모형인 FLOW-3D를 이용하여 이층 침전지의 유량분배 최적화를 위한 설계인자를 도출 하였다. 특히 상 하층에 위치하고 있는 유입부의 위치적인 특성을 고려하여 유입부의 직경을 상층 $500mm{\sim}600mm$, 하층 $500mm{\sim}700mm$으로 변화시키며 수치모의를 수행하였으며, 유입량의 분배효과를 확인하기 위해 각 동일한 위치에서 유입량을 산정하였다. 각 케이스별 분배효과를 분석한 결과 상 하층의 유입부 직경을 상층 600mm 와 하층 700mm를 적용했을 경우 유입량의 표준편차가 가장 작게 발생하며, 침전지 내부의 흐름이 원활하게 이루어지는 것으로 확인되었다. 본 연구에서는 상용 CFD모형인 FLOW-3D를 계획 중인 H하수처리장의 이층 침전지 설계에 적용하였으며 유입부 직경에 따른 분배효과를 분석하였다.

  • PDF

Scaling of Gas-Slurry Mass transfer in Three-phase Bubble Column Reactors (삼상슬러리 기포탑 반응기에서 기체-슬러리 물질전달의 Scaling)

  • Lim, Hyunoh;Seo, Myungjae;Kang, Yong;Jung, Heon;Lee, Hotae;Kim, Sangdon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.111.2-111.2
    • /
    • 2010
  • 삼상슬러리 기포탑 반응기의 설계 및 Scale-up을 위하여 기포탑의 직경변화에 따른 기체-슬러리 계면에서의 물질전달 현상의 Similarity를 검토하고, 기체-슬러리 계면에서의 물질전달 현상과 슬러리 기포탑 반응기의 운전변수 및 반응물들의 물성들과의 연관성을 고찰하기 위하여 삼상슬러리 기포탑의 물질전달계(System)에서 주요 파라메타를 도출하였으며, 이들 파라메터들을 이용하여 슬러리 기포탑반응기의 물질전달 Scaling을 검토하였다. 물질전달계의 주요제어인자로는 기체-액체 부피물질전달계수($k_La$), 슬러리상의 확산도($D_{SL}$), 기포탑의 직경(D), 기포탑 반응기에 유입되는 기체의 유입속도($U_G$), 기포탑 반응기 내부의 연속상인 슬러리상의 표면장력(${\sigma}_{SL}$), 슬러리상과 기체상간의 밀도차(${\rho}_{SL}-{\rho}_G$) 그리고 슬러리상의 점도(${\mu}_{SL}$)등 슬러리 상의 물성을 선정하였으며 중력가속도(g)를 선정하였다. 물질전달계의 Scling을 검토하기위하여 이를 재구성하였으며 기포탑 반응기의 구조와 직경이 변화함에 따라 이들 무차원군의 변화양상을 고찰하였다. 실험적으로 측정된 물질전달계수와 Scaling에 의해 예측된 물질전달계수를 비교 검토함으로써 본 연구의 Correlation의 적용범위를 제시하였다.

  • PDF

The Influence of the Front Surface Power and the Refraction Index on RMS Spot Diameter (전면 굴절력과 굴절률이 착락원의 크기에 미치는 영향)

  • Park, Seong-Jong;Shin, Cheol-Guen;Ju, Seok-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.57-63
    • /
    • 2003
  • To investigate the RMS SD(Root Mean Square Spot Diameter) in a back focal plane as the front surface power, the center thickness, and the refraction index vary, we use programs which are Cove V and LOSA 2.0, and consider a spectacle lens with back vertex power of -4.00D and diameter of 70 mm. We also consider the front surface power varied from 0.00 to 10.00D, the center thickness varied from 1.1 to 2.0 mm, and the indices which are $n_d$ = 1.498, 1.523, 1.586, and 1.660, respectively. As the front surface power increases the RMS SD in the back focal plane increase rapidly. When the refraction index increases, the RMS SD in the back focal plane decrease and the variation of RMS SD in the back focal plane decreases as the front surface power increases. When the center thickness of spectacle lens increases, the RMS SD in the back focal plane is constant and the edge thickness of that increases. We know from these results that the image in the back focal plane of a spherical spectacle lens improves as the front surface power increases and the refraction index decreases.

  • PDF

Comparison of defect size measured by transthoracic and transesophageal echocardiography with balloon occlusive diameter measured during transcatheter closure of atrial septal defect (경피적 심방중격결손 폐쇄술 시 경흉부 및 경식도 초음파 검사 상의 결손의 크기와 풍선 폐쇄 직경과의 관계)

  • Hur, Kyong;Kim, Jeong Eun;Kim, Yuria;Kwon, Hae Sik;Yoo, Byung Won;Choi, Jae Young;Sul, Jun Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.10
    • /
    • pp.970-975
    • /
    • 2007
  • Purpose : Accurate measurement of defect size is important in transcatheter closure of atrial septal defect (ASD). We performed this study to analyze the difference between the measured ASD size and balloon occlusive diameter (BOD) by transthoracic (TTE) or transesophageal echocardiography (TEE). Methods : We investigated 78 patients who underwent transcatheter closure of ASD. The defect size and the distance between the surrounding structures were measured by TTE and TEE. The BOD was measured by TEE during cardiac catheterization. Clinical characteristics and echocardiographic data were compared and analyzed. Results : The difference between BOD and diameter by TTE was $4.8{\pm}3.6mm$ on short axis view, $5.4{\pm}3.2mm$ on long axis view. The difference between BOD and diameter by TEE was $3.6{\pm}2.2mm$ on short axis view, $4.2{\pm}3.1mm$ on long axis view. The difference between BOD and the diameter of defects on TTE, TEE had statistically significant positive correlations with the age of the patients, distance between the, defect and posterior atrial septal wall, the distance between the defect and the mitral valve leaflet, and the diameter of defects and the length of the atrial septum on TTE (P<0.05). Conclusion : BOD of ASD can be estimated by the diameter on TTE and TEE. BOD is expected to measure larger, depending on the size of defects, the distance from surrounding structures and the location of defects on echocardiography. Our data offers important information on details of transcatheter ASD closure which can be helpful in predicting suitability and judging the procedural appropriateness during the procedure.

Development of Coaxial Propeller Test Facility and Experimental Study on Hover Performance Characteristics for Drone (드론용 동축 프로펠러 시험장치 개발 및 제자리비행 성능특성에 대한 실험적 연구)

  • Song, Youn-Ha;Kim, Deog-Kwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.1
    • /
    • pp.59-67
    • /
    • 2018
  • In this paper, the test facility for coaxial propellers at low Reynolds developed and validated by measured data. The test equipment was designed to measure the hovering performance of propellers according to distances between the upper/lower propellers. Thrust, torque, rotational speed, vibration, and amperage of upper and lower propellers can be measured separately. The data acquisition system was built to collect signals of sensors, and LabVIEW software was used to control the motor and collect the signal. The hover performance tests of single propellers were preceded for the facility validation, and then the performance values of coaxial propellers were measured according to distances and diameter differences between the upper/lower propellers. The results showed that the high efficiency is achieved at 20%~30% distance between the upper propeller and lower one. The configuration that the upper propeller has shorter diameter than the lower one has the highest efficiency than other configuration.

영상처리방법에 의한 핵연료봉의 직경측정

  • 구대서;이원상;전용범;민덕기;노성기
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.515-520
    • /
    • 1998
  • 영상처리방법에 의한 핵연료봉의 제원을 측정하기 위하여 영상처리 소프트웨어를 개발하였으며, 이 영상처리방법에 의하여 핵연료봉의 직경에 대한 백분을 측정상대오차는 $\pm$2.09% 이내이며 영상처리방법이 아닌 기존 방법에 의한 백분율 측정상대오차 $\pm$9.70 %보다 측정정확도가 약 5배정도 향상되었다.

  • PDF