DOI QR코드

DOI QR Code

Normal Glenoid Size of the Korean in 7th and 8th Decades

한국인 60~70대의 정상 견갑골 관절와의 크기

  • Moon, Young-Lae (Department of Orthopedic Surgery, Chosun University Hospital) ;
  • Ha, Sang-Ho (Department of Orthopedic Surgery, Chosun University Hospital) ;
  • Noh, Kyung-Hwan (Department of Orthopedic Surgery, Chosun University Hospital)
  • 문영래 (조선대학교 병원 정형외과) ;
  • 하상호 (조선대학교 병원 정형외과) ;
  • 노경환 (조선대학교 병원 정형외과)
  • Published : 2008.06.15

Abstract

Purpose: We wanted to evaluate the normal glenoid size of Koreans in their 7th and 8th decades by conducting Computed tomographic (CT) studies. Materials and Methods: The CT images were obtained from the normal scapulae of the patients (mean age: 68.8) who had humeral fracture. A display workstation version 2.0.73.315 was used to measure the scans to determine the maximal superoinferior (SI) and anteroposterior (AP) diameters of the glenoid vault. Results: The average diameters of curvature of the glenoid were 31.2 mm (range: 27 to 34 mm) in the superior-inferior direction and 26.1mm (range: 22 to 31mm) in the anterior-posterior direction. Conclusion: This study showed the normal glenoid size of Koreans and it is different from the size that the international literature reported. It should be an important factor for the treatment of fracture or in designing arthroplasty implants.

목적: 전산화단층촬영을 이용하여 한국인 60, 70대의 정상 견갑골 관절와의 크기를 평가하고자 하였다. 대상 및 방법: 견갑골의 손상이 없는 것으로 확인된 상완골 골절에서 시행된 견관절 전산화단층촬영 결과를 대상으로 하였다. 환자는 총 25명으로 남자가 14명, 여자가 11명이었다. 환자의 연령은 62세에서 76세 사이였으며, 평균 연령은 68.8세였다. 사용한 소프트 웨어는 Display workstation version 2.03.73.315 였으며 견관절 관절와의 최대 상하 및 전후방 직경을 측정하였다. 결과: 측정된 견관절 관절와의 최대 상하 직경은 평균 31.2 mm ($27{\sim}34\;mm$)였으며, 최대 전후방 직경은 평균 26.1 mm ($22{\sim}31\;mm$)였다. 결론: 이러한 결과는 다른 국제 학술지의 보고와는 다른 양상으로 국내 환자의 골절 치료 및 인공 관절 모델을 개발하는데 중요한 인자가 될 것으로 보인다.

Keywords

References

  1. Bohsali K, Wirth M, Rockwood CJ: Complications of total shoulder arthroplasty. J Bone Joint Surg Am, 88: 2279-2292, 2006. https://doi.org/10.2106/JBJS.F.00125
  2. Codsi MJ, Bennetts C, Gordiev K, et al: Normal glenoid vault anatomy and validation of a novel glenoid implant shape. J Shoulder Elbow Surg, 17: 471-478, 2008. https://doi.org/10.1016/j.jse.2007.08.010
  3. Codsi MJ, Bennetts C, Powell K, Iannotti JP: Locations for screw fixation beyond the glenoid vault for fixation of glenoid implants into the scapula: An anatomic study. J Shoulder Elbow Surg, 16: S84-89, 2007. https://doi.org/10.1016/j.jse.2006.07.009
  4. Harman M, Frankle M, Vasey M, Banks S: Initial glenoid component fixation in “reverse” total shoulder arthroplasty: A biomechanical evaluation. J Shoulder Elbow Surg, 14: S162-167, 2005. https://doi.org/10.1016/j.jse.2004.09.030
  5. Iannotti JP, Gabriel J, Schneck S, Evans B, Misra S: The normal glenohumeral relationships. An anatomical study of one hundred and forty shoulders. J Bone Joint Surg Am, 74: 491-500, 1992. https://doi.org/10.2106/00004623-199274040-00004
  6. Matsen FA, Boileau P, Walch G, Gerber C, Bicknell RT: The reverse total shoulder arthroplasty. J Bone Joint Surg Am, 89: 660-667, 2007.
  7. Middernacht B, De Roo PJ, Van Maele G, De Wilde LF: Consequences of Scapular Anatomy for Reversed Total Shoulder Arthroplasty. Clin Orthop Relat Res, 2008.
  8. Mimar R, Limb D, Hall RM: Evaluation of the mechanical and architectural properties of glenoid bone. J Shoulder Elbow Surg, 17: 336-341, 2008. https://doi.org/10.1016/j.jse.2007.07.024
  9. Valenti P, Sauzieres P, Cogswell L, O’Toole G, Katz D: The reverse shoulder prosthesis--surgical technique. Tech Hand Up Extrem Surg, 12: 46-55, 2008. https://doi.org/10.1097/BTH.0b013e3181572b14
  10. De Wilde LF, Berghs BM, Audenaert E, Sys G, Van Maele GO, Barbaix E: About the variability of the shape of the glenoid cavity. Surg Radiol Anat, 26: 54-59, 2004. https://doi.org/10.1007/s00276-003-0167-1

Cited by

  1. Penetration depth and size of the nonarthritic glenoid: Implications for glenoid replacement vol.25, pp.8, 2012, https://doi.org/10.1002/ca.22045
  2. Clinical and Radiological Results of Reverse Total Shoulder Arthroplasty Using a 25-mm Glenoid Baseplate vol.18, pp.4, 2015, https://doi.org/10.5397/cise.2015.18.4.242