• Title/Summary/Keyword: 상분할

Search Result 926, Processing Time 0.03 seconds

Effect of Cytarabine, Melphalan, and Total Body Irradiation as Conditioning for Autologous Stem Cell Transplantation for Patients with AML in First Remission (1차 관해된 급성 골수성 백혈병에서 자가 조혈모세포 이식을 위한 Cytarabine, Melphalan, 전신 방사선치료의 효과)

  • Kang Ki Mun;Choi Byung Ock;Chai Gyu Young;Kang Young Nam;Jang Hong Sek;Kim Hee Jae;Min Wo Sung;Kim Chun Choo;Choi Ihl Bohng
    • Radiation Oncology Journal
    • /
    • v.21 no.3
    • /
    • pp.192-198
    • /
    • 2003
  • Purpose: Current results of autologous stem cell transplantation (SCT) suggest that this procedure may prolong disease free survival In patients with acute myeloid leukemia (AML). Autologous SCT is increasingly used as treatment for AML in first remission. The aim of this study was to evaluate the outcome of autologous SCT for patients with AML in first remission treated by autologous SCT using cytarabine, melphalan and total body irradiation (TBI) as the conditioning regimen. Materials and Methods: Between January 1995 and December 1999, 29 patients with AML in first remission underwent autologous SCT. The median age of patients was 33 years (range, 16 to 47). The conditioning regimen consisted of cytarabine ($3.0\;gm/m^2$ for 3 days), melphalan ($100\;gm/m^2$ for 1 day) and TBI (total 1000 cGy in five fractions over 3 days). Results: The median follow up was 40 months with a range of 3 to 58 months. The 4-year cumulative probability of disease free survival was 69.0%, and median survival was 41.5 months. The 4-year relapse rate was 27.6%. The factor Influencing disease free survival and relapse rate was the French-American-British (FAB) classification ($M_3$ group vs. other groups; p=0.048, p=0.043). One patient died from treatment-related toxicity. Conclusion:: Although the small number of patients does not allow us to draw any firm conclusion, our results were encouraging and suggest that the association of cytarabine, melphalan and TBI as a conditioning regimen for autologous SCT for AML on first remission appears to be safe and effective.

Treatment of Carcinoma of the Uterine Cervix with High-Dose-Rate Intracavitary Irradiation using Ralstron (고선량률 강내조사를 사용한 자궁경부암의 치료)

  • Suh Chang Ok;Kim Gwi Eon;Loh John J.K.
    • Radiation Oncology Journal
    • /
    • v.8 no.2
    • /
    • pp.231-239
    • /
    • 1990
  • From May 1979 through December 1981 a total of 524 patients with carcinoma of the uterine cervix were treated by radiation therapy with curative intent. Among the 524 patients, 350 were treated with a high-dose-rate (HDR), remote-controlled, afterloading intracavitary irradiation (ICR) system using a cobalt source (Ralstron), and 168 patients received a low-dose-rate (LDR) ICR using a radium source. External beam irradiation with a total dose of 40-50 Gy to the whole pelvis followed by intracavitary irradiation with a total dose of 30-39 Gy in 10-13 fractions to point A was the treatment protocol. ICR was given three times a week with a dose of 3 Gy per fraction. Five-year actuarial survival rates in the HDR-ICR group were $77.6{\%}$ in stage IB (N=20), $68.2{\%}$ in stage II (N=182), and $50.9{\%}$ in stage III (N=148). In LDR-ICR group, 5-year survival rates were $87.5{\%}$ in stage IB (N=22), $66.3{\%}$ in stage II (N=91), and $55.4{\%}$ in stage III (N=52). Survival rates showed a statistically significant difference by stage, but there was no significant difference between the two ICR groups. Late bowel complications after radiotherapy were noted in $3.7{\%}$ of the HDR-ICR group and $8.4{\%}$ of the LDR-ICR group. There was no severe complication requiring surgical management. The incidence of bladder complications was $1.4{\%}$ in the HDR-ICR group and $2.4{\%}$ in the LDR-ICR group. The application of HDR-ICR was technically simple and easily performed on an outpatient basis without anesthesia, and the patients tolerated it very well. Radiation exposure to personnel was virtually nil in contrast to that of LDR-ICR. Within a given period of time, more patients can be treated with HDR-ICR because of the short treatment time. Therefore, the HDR-ICR system is highly recommended for a cancer center, particularly one with a large number of patients to be treated. In order to achieve an improved outcome, however, the optimum dose-fractionation schedule of HDR-ICR and optimum combination of intracavitary irradiation with external beam irradiation should be determined through an extensive protocol.

  • PDF

Inter-fractional Target Displacement in the Prostate Image-Guided Radiotherapy using Cone Beam Computed Tomography (전립선암 영상유도 방사선 치료시 골반내장기의 체적변화에 따른 표적장기의 변화)

  • Dong, Kap Sang;Back, Chang Wook;Jeong, Yun Jeong;Bae, Jae Beom;Choi, Young Eun;Sung, Ki Hoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.161-169
    • /
    • 2016
  • Purpose : To quantify the inter-fractional variation in prostate displacement and their dosimetric effects for prostate cancer treatment. Materials and Methods : A total of 176 daily cone-beam CT (CBCT) sets acquired for 6 prostate cancer patients treated with volumetric-modulated arc therapy (VMAT) were retrospectively reviewed. For each patient, the planning CT (pCT) was registered to each daily CBCT by aligning the bony anatomy. The prostate, rectum, and bladder were delineated on daily CBCT, and the contours of these organs in the pCT were copied to the daily CBCT. The concordance of prostate displacement, deformation, and size variation between pCT and daily CBCT was evaluated using the Dice similarity coefficient (DSC). Results : The mean volume of prostate was 37.2 cm3 in the initial pCT, and the variation was around ${\pm}5%$ during the entire course of treatment for all patients. The mean DSC was 89.9%, ranging from 70% to 100% for prostate displacement. Although the volume change of bladder and rectum per treatment fraction did not show any correlation with the value of DSC (r=-0.084, p=0.268 and r=-0.162, p=0.032, respectively), a decrease in the DSC value was observed with increasing volume change of the bladder and rectum (r=-0.230,p=0.049 and r=-0.240,p=0.020, respectively). Conclusion : Consistency of the volume of the bladder and rectum cannot guarantee the accuracy of the treatment. Our results suggest that patient setup with the registration between the pCT and daily CBCT should be considered aligning soft tissue.

  • PDF

Utility Estimation of the Manufactured Stereotactic Body Radiotherapy Immobilization (자체 제작한 정위적체부방사선치료(Stereotactic Body Radiotherapy) 고정용구의 유용성 평가)

  • Lee, Dong-Hoon;Ahn, Jong-Ho;Seo, Jeong-Min;Shin, Eun-Hyeok;Choi, Byeong-Gi;Song, Gi-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • Purpose: Immobilizations used in order to maintain the reproducibility of a patient set-up and the stable posture for a long period are important more than anything else for the accurate treatment when the stereotactic body radiotherapy is underway. So the purpose of this study is to adapt the optimum immobilizations for the stereotactic body radiotherapy by comparing two commercial immobilizations with the self-manufactured immobilizations. Materials and Methods: Five people were selected for the experiment and three different immobilizations (A: Wing-board, B: BodyFix system, C: Arm up holder with vac-lock) were used to each target. After deciding on the target's most stable respiratory cycles, the targets were asked to wear a goggle monitor and maintain their respiration regularly for thirty minutes to obtain the respiratory signals. To analyze the respiratory signal, the standard deviation and the variation value of the peak value and the valley value of the respiratory signal were separated by time zone with the self-developed program at the hospital and each tie-downs were compared for the estimation by calculating a comparative index using the above. Results: The stability of each immobilizations were measured in consideration of deviation changes studied in each respiratory time lapse. Comparative indexes of each immobilizations of each experimenter are shown to be A: 11.20, B: 4.87, C: 1.63 / A: 3.94, B: 0.67, C: 0.13 / A: 2.41, B: 0.29, C: 0.04 / A: 0.16, B: 0.19, C: 0.007 / A: 35.70, B: 2.37, C: 1.86. And when all five experimenters wore the immobilizations C, the test proved the most stable value while four people wearing A and one man wearing D expressed relatively the most unstable respiratory outcomes. Conclusion: The self-developed immobilizations, so called the arm up holder vac-lock for the stereotactic body radiotherapy is expected to improve the effect of the treatment by decreasing the intra-fraction organ motions because it keeps the respiration more stable than other two immobilizations. Particularly in case of the stereotactic body therapy which requires the maintenance of set-up state for a long time, the self-developed immobilizations is thought to more useful for stereotactic body radiotherapy rather than the rest two immobilizations with instable respiratory cycle as time passes.

  • PDF

A Study on the Characteristics of Oddly Shaped Stone's Arrangement at Donggwoldo (동궐도(東闕圖)에 나타난 괴석(怪石)의 배치특성에 관한 연구)

  • Jung, Woo-Jin;Kim, Hwa-Ok;Park, Yool-Jin
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.32 no.2
    • /
    • pp.12-26
    • /
    • 2014
  • This study has researched the forms of arrangement and use of the oddly shaped stones which were used at palaces during Joseon Dynasty based on arrangements of stones as shown in Donggwoldo(東闕圖), and tried to identify its special features. The sorts of stone's arrangements which set formal patterns by assisting an axis in Donggwoldo can be classified as the single type using one stone, the symmetrical type using 2 stones symmetrically and the parallel type using 3 or more stones. The single type was used to endow a focal point and to accent centrality by arranging a stone on the axis performed from formal shaped buildings. The symmetrical type was used to show order and hierarchy by placing two odd-shaped stones on either side of a building. And the parallel type which is arranged three stones side by side, is put a middle stone on the central axis line to determine strong directional and frontality. Also similarity to method of arrangement of stones can be found from planting trees in a prominent way for scenery or planting trees symmetrically. Stones and trees can be chosen according to nature and scale of places and basically their effects of formation of axis and creating typical space is same. Based on these respect, the characteristics of arrangement of stones shown in Donggwoldo can be briefly summarized as follows. First, the oddly shaped stones were used by creating a centripetal space in order to show a grade of rank. Second, the distances among stones could be adjusted to the sizes of the architecture which was at the center. The aim was to provide stability through the balanced composition between the central axis and symmetrical structures. Third, the form of regularity was added by using stone vase in consideration of irregular shape of stone causing interference in forming regular symmetry. Fourth, a centrality was emphasized by adding change to central stones in the parallel type used 3 erect stones. Fifth, the sizes of stone were limited in order to make smooth for the mix and adjustment of its position with the types of other garden ornaments, so the oddly shaped stones in palace have portability. Sixth, the oddly shaped stones in palace which were appreciated as inspirational object basically were a sculpture of the same quality with suiseki (壽石), and the appreciative method, the composition and shape had developed in the same texture. Finally, the even number of stones by parallel type were arranged by equal partition. But odd number of stones followed the method with symmetrical arrangement on its center stone. These principles of stone arrangement are judged as distinguishing methods which oddly shaped stones was made and used in Joseon palaces.

Full mouth Rehabilitation with Orthognathic Surgery in Facial Asymmetry Patient : Case Report (안면 비대칭환자의 악교정 수술을 동반한 완전구강회복)

  • Im, So-Min;Shin, Hyoung-Joo;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.359-371
    • /
    • 2010
  • Facial asymmetry has been found with a higher frequency (70~84%) in skeletal class III malocclusion patients. Anticipating the poor prognosis of prosthesis due to malocclusion, occlusal stability must be obtained by orthodontic treatment. Moreover, orthodontic surgery would be needed in some severe cases for better functional and esthetic results. The orthognathic surgery is performed on one jaw or two jaw depending on the results of facial diagnosis. Genioplasty may change the vertical, horizontal, sagittal position of chin by osteotomy or augmentation using implants, also. This case is about a 24 year-old male patient who visited our clinic to solve the facial asymmetry and mandibular prognathism. Skeletal class III malocclusion, maxillary canting and menton deviation to left by 13 mm were detected. Multiple ill-fitting prostheses, unesthetic maxillary anterior prostheses, and several dental caries were found. After pre-operative orthodontic treatment, Le-Fort I osteotomy, sagittal split ramus osteotomy, genioplasty, right mandibular angle augmentation were done for the correction of jaw relation and asymmetry. By diagnostic wax-up after post-operative orthodontic treatment, maxillary full mouth rehabilitation and mandibular posterior restorations were planned out. For better result, clinical crown lengthening procedure was done on #11, 12 and implant was placed on left mandibular first molar area. The patient was satisfied with the final prostheses. Because of his high caries risk, long-term prognosis will depend on the consistent maintenance of oral hygiene and periodic follow-up.

Helicopter Pilot Metaphor for 3D Space Navigation and its implementation using a Joystick (3차원 공간 탐색을 위한 헬리콥터 조종사 메타포어와 그 구현)

  • Kim, Young-Kyoung;Jung, Moon-Ryul;Paik, Doowon;Kim, Dong-Hyun
    • Journal of the Korea Computer Graphics Society
    • /
    • v.3 no.1
    • /
    • pp.57-67
    • /
    • 1997
  • The navigation of virtual space comes down to the manipulation of the virtual camera. The movement of the virtual cameras has 6 degrees of freedom. However, input devices such as mouses and joysticks are 2D. So, the movement of the camera that corresponds to the input device is 2D movement at the given moment. Therefore, the 3D movement of the camera can be implemented by means of the combination of 2D and 1D movements of the camera. Many of the virtual space navigation browser use several navigation modes to solve this problem. But, the criteria for distinguishing different modes are not clear, somed of the manipulations in each mode are repeated in other modes, and the kinesthetic correspondence of the input devices is often confusing. Hence the user has difficulty in making correct decisions when navigating the virtual space. To solve this problem, we use a single navigation metaphore in which different modes are organically integrated. In this paper we propose a helicopter pilot metaphor. Using the helicopter pilot metaphore means that the user navigates the virtual space like a pilot of a helicopter flying in space. In this paper, we distinguished six 2D movement spaces of the helicopter: (1) the movement on the horizontal plane, (2) the movement on the vertical plane,k (3) the pitch and yaw rotations about the current position, (4) the roll and pitch rotations about the current position, (5) the horizontal and vertical turning, and (6) the rotation about the target object. The six 3D movement spaces are visualized and displayed as a sequence of auxiliary windows. The user can select the desired movement space simply by jumping from one window to another. The user can select the desired movement by looking at the displaced 2D movement spaces. The movement of the camera in each movement space is controlled by the usual movements of the joystick.

  • PDF

Postoperative Adiuvant Radiation Therapy in Endometrial Carcinoma (자궁내막암의 수술 후 보조적 방사선치료)

  • Shin Kyung Hwan;Choi Eun Kyung;Ahn Seung Do;Chang Hyesook;Mok Jung-Eun;Nam Joo Hyun;Kim Young Tak;Kim Yong Man;Kim Jong Hyeok
    • Radiation Oncology Journal
    • /
    • v.18 no.1
    • /
    • pp.40-45
    • /
    • 2000
  • Purpose : To evaluate the histopathological prognostic factors, relapse pattern and survival in patients with endometrial carcinoma who were treated with surgery and postoperative adjuvant radiotherapy (RT). Methods and Materials : From September 1991 to December 1997, 27 patients with endometrial carcinoma treated with surgery and postoperative adjuvant RT at Asan Medical Center were entered in this study. Surgery was peformed with total abdominal hysterectomy in six, total abdominal hysterectomy with pelvic lymph node dissection in eight and radical hysterectomy in 13 patients. External RT of 50.4 Gy was done to all patients and among these, additional high dose rate vaginal vault irradiation of 20$\~$25 Gy with fractional dose of 4$\~$5 Gy was boosted In 16 patients. The patients were followed for 6$\~$95 months(median 30). Results : The number of patients according to FIGO stage were I 18 (67$\%$), II 1 ($4\%$) and III 7 ($26\%$). Patients with poor histologic grade, deep myometrial invasion, adnexal involvement, lymphovascular invasion showed more pelvic lymph node involvement, but no statistical significance was indicated. The 5 year overall and disease free survival were 100$\%$ and 76.8$\%$, respectively. Relapse sites were pelvic, para-aortic lymph node, and multiple metastases including lung, and no vaginal relapse was developed. Factors that were associated with disease free survival were FIGO stage (p=0.01), lymphovascular invasion (p=0.03), pelvic lymph node involvement (p=0.0001). There was only one Grade 1 rectal bleeding without moderate to severe complications. Conclusion : Postoperative adjuvant RT is considered to reduce the loco-regional failure, resulting the improvement of survival. The group of patients with the risk of vaginal failure without vaginal vault irradiation should be investigated according to stage and grade.

  • PDF

THE PALATAL MORPHOLOGY OF THE CHILDREN WITH CLASS II DIV.1 MALOCCLUSION IN MIXED DENTITION : A STUDY USING THREE-DIMENSIONAL LASER SCANNER (혼합치열기 II급 1류 부정교합 어린이의 구개형태 : 3차원 레이저 스캐너를 이용한 연구)

  • Yang, Jung-Hyun;Lee, Sang-Hoon;Hahn, Se-Hyun;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.2
    • /
    • pp.270-277
    • /
    • 2005
  • The purpose of this study was to clarify the palatal volume and anterior palatal slope of the children with class II div.1 malocclusion and normal occlusion in mixed dentition(Hellman dental age III A) using three-dimensional laser scanner. Samples were consisted of 31 children with skeletal class II div.1 malocclusion in mixed dentition and 29 children with normal occlusion and profile among the contestants in 2000-2004 Healthy Dentition Contest in Seoul. Totally 60 maxillary study model were taken. Each cast was scanned by three-dimensional laser scanner (Breuckmann opto-TOP HE, INUS, Korea) and shaped into the three-dimension image by Rapidform 2004 program(INUS, Korea). And the palatal volume and anterior palatal slope of each cast were calculated by Rapidform 2004 program(INUS, Korea). The values were statistically compared and evaluated by independent samples t-test with 95% of significance level. The results were as follows: 1. Palatal volume was significantly lesser in children with class II div.1 malocclusion than that of normal occlusion in mixed dentition(p<0.05). 2. No significant difference in the anterior palatal slope and palatal height was found between the children with class II div.1 malocclusion and normal occlusion in mixed dentition(p>0.05). 3. Palatal length was significantly greater in children with class II div.1 malocclusion than that of normal occlusion in mixed dentition(p<0.01). 4. Intercanine and intermolar width were significantly lesser in children with class II div.1 malocclusion than those of normal occlusion in mixed dentition(respectively p<0.05 and p<0.01).

  • PDF

Crosshole EM 2.5D Modeling by the Extended Born Approximation (확장된 Born 근사에 의한 시추공간 전자탐사 2.5차원 모델링)

  • Cho, In-Ky;Suh, Jung-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.1 no.2
    • /
    • pp.127-135
    • /
    • 1998
  • The Born approximation is widely used for solving the complex scattering problems in electromagnetics. Approximating total internal electric field by the background field is reasonable for small material contrasts as long as scatterer is not too large and the frequency is not too high. However in many geophysical applications, moderate and high conductivity contrasts cause both real and imaginary part of internal electric field to differ greatly from background. In the extended Born approximation, which can improve the accuracy of Born approximation dramatically, the total electric field in the integral over the scattering volume is approximated by the background electric field projected to a depolarization tensor. The finite difference and elements methods are usually used in EM scattering problems with a 2D model and a 3D source, due to their capability for simulating complex subsurface conductivity distributions. The price paid for a 3D source is that many wavenumber domain solutions and their inverse Fourier transform must be computed. In these differential equation methods, all the area including homogeneous region should be discretized, which increases the number of nodes and matrix size. Therefore, the differential equation methods need a lot of computing time and large memory. In this study, EM modeling program for a 2D model and a 3D source is developed, which is based on the extended Born approximation. The solution is very fast and stable. Using the program, crosshole EM responses with a vertical magnetic dipole source are obtained and the results are compared with those of 3D integral equation solutions. The agreement between the integral equation solution and extended Born approximation is remarkable within the entire frequency range, but degrades with the increase of conductivity contrast between anomalous body and background medium. The extended Born approximation is accurate in the case conductivity contrast is lower than 1:10. Therefore, the location and conductivity of the anomalous body can be estimated effectively by the extended Born approximation although the quantitative estimate of conductivity is difficult for the case conductivity contrast is too high.

  • PDF