• Title/Summary/Keyword: 상대불확도

Search Result 40, Processing Time 0.026 seconds

A short study of uncertainty for post column isotope dilution method in HPLC-ICP/MS (HPLC-ICP/MS에서 후 컬럼 동위원소 희석법의 기초적인 불확도 연구)

  • Joo, Mingyu;Pak, Yong-Nam
    • Analytical Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.269-276
    • /
    • 2014
  • A short study for the uncertainty of post column isotope dilution method has been performed for the analysis of Selenomethionine in HPLC-ICP/MS. Major error sources studied were concentration and the flow rate of Se isotope solution, atomic weights of Se in spike and sample, and isotope ratio measured for the spiked sample. Uncertainties were obtained for each factor and the contribution for the total concentration uncertainty was 54.4% and 0.61%, 0.0072% and 0.018%, and 45.0%, respectively. The biggest contribution factor was concentration of the spike solution and the second was the isotopic ratio measured for the spiked sample solution. The mass flow rate of spike and atomic weights did not show much contribution. The calculated total uncertainty was $1.46ng{\cdot}g^{-1}$ for the standard SeMet ($126.30ng{\cdot}g^{-1}$). The experimental result was $127.09{\pm}1.46ng{\cdot}g^{-1}$ and the relative uncertainty was 1.20%.

Precision measurements of radiometric aperture area by laser spot scanning along the edge of the aperture (레이저 스폿의 칼날주사 방법에 의한 복사계 개구 면적의 정밀측정)

  • 강창호;김석원;박승남
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.3
    • /
    • pp.258-262
    • /
    • 2004
  • The uncertainty of the detector-based candela scale is limited by the area measurement uncertainty of radiometric apertures. The apertures were fabricated with a diamond-turning machine which trimmed the edge of the apertures as sharply as a knife edge. The positions of the apertures were controlled by a digital feedback algorithm to scan the laser spot with the beam waist less than 5 ${\mu}{\textrm}{m}$. The knife edge scan yielded a set of coordinates on the edges of the aperture. The areas of the apertures were obtained by fitting the coordinates to the ellipses. The relative standard uncertainty of the measurement was estimated to be 8${\times}$10$^{-5}$.

Uncertainty Analysis of the Calculated Radioactivity in Liquid Effluent Released as Batch Mode from a Nuclear Power Plant (발전용원자로에서 뱃치방식으로 배출되는 액체상 방사성물질의 방사능 평가결과에 대한 불확도 해석)

  • 정재학;박원재
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.562-571
    • /
    • 2003
  • A series of factors such as sampling, pretreatment measurement, volume estimation which induces uncertainty of the calculated radioactivity in liquid effluent released from a nuclear power plant were analyzed. It is innately impossible to estimate exact error of the calculated radioactivity, since most of the input parameters are determined by a single measurement and true value of the released radioactivity cannot be known. In this paper, a systematic model to calculate uncertainty of the released liquid radioactivity was developed based upon the guidance report published by the ISO in 1993, and the model was applied to a set of hypothetical batch release conditions. As a result, the Priority of each input parameter was turned out to be (1) wastewater volume, (2) sample volume, and (3) measured radioactivity of the sample. In addition, probability distribution of the released radioactivity was simulated by Monte Carlo method combining the probability distribution of each input parameter It was shown that the radioactivity released to the environment, which has been reported as a single value, has a certain form of probability distribution.

  • PDF

Comparison of Geometrical Factors of Dielectric Resonators Prepared for the Surface Resistance of Superconductor Films: Field Analysis vs. Computer Simulation (초전도체 박막의 표면저항 측정용 유전체 공진기에 대한 Geometrical factor의 비교 : 전자기장 해석 대 시뮬레이션)

  • Yang, Woo-Il;Jung, Ho-Sang;Kim, Myung-Su;Cho, Man-Soon;Choo, Kee-Nam;Lee, Sang-Young
    • Progress in Superconductivity
    • /
    • v.13 no.2
    • /
    • pp.97-104
    • /
    • 2011
  • In the dielectric resonator method, which has been widely used for measuring the microwave surface resistance of superconductors, accuracies in the geometrical factors (G-factors) affect the uncertainty in the measured surface resistance. We compare the G-factors of short-ended sapphire resonator as obtained by using field analysis with those by using computer simulations: The former is obtained by using the analytic expressions for the electric and the magnetic field components inside the resonator, and the latter by using computer software. The G-factors as obtained by using the latter appear to be closer to those obtained by using the former as the resonator space is divided into larger number of sub-space, i.e., a tighter mesh, with a difference of ~8 % observed for a mesh of 14400 sub-spaces reduced to ~2 % for 114996 sub-spaces. Variations in the relative uncertainty in the surface resistance of typical $YBa_2Cu_3O_{7-\delta}$ superconductor films with those in the G-factors are studied, which provides an upper limit of the relative uncertainty in the G-factors required for realizing the target uncertainty in the surface resistance. These results could be useful in estimating the optimum number of meshes for obtaining the G-factors through computer simulations.

Estimation of conbined uncertainty for dioxin reference materials from the fly ash (소각재에 함유된 다이옥신의 확장불확도 평가)

  • Kim, Woo-Il;Shin, Sun-Kyoung;Lee, Su-Young;Kim, Dong-Hoon;Kang, Hak-Gu;Han, Jin-Suk
    • Analytical Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.363-370
    • /
    • 2010
  • This study was performed to validate reference materials (RMs) for proficiency testing (PT) in waste inter-laboratories. Dioxin RMs were prepared from fly ash in industrial incinerators. The relative standard deviations (RSDs) of analytical results were 2.6~15.7% for the dioxin RMs in 10 replicates (between and withinbottles). Data were collected and statistical analysis was performed by the One-way ANOVA test. The combined uncertainties of target isomers in dioxin analysis were 0.114~7.091.

Development of 6-component Force/Moment Calibration Machine (6분력 힘/모멘트 교정기의 개발)

  • 김갑순;강대임
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.9
    • /
    • pp.127-134
    • /
    • 1998
  • This paper describes the design of a 6-component force/moment calibration machine with having the maximum capacities of 500 N in forces and 50 Nm in moments. To be used for the characteristic of a multi-component load cell. this machine consists of a body, a fixture, a force generating system, a moment generating system and weights. We have also evaluated the accuracy of the calibration machine. Test results show that the expanded relative uncertainty for force components $\pmFx,\;\pmFy\;and\;moment\;components\;\pmMx,\;\pmMy\;are\;less\; than\;8.6\times10^{-4}$, and force components +Fz, -Fz and moment components $\pmMz\;is\;less\;than\;1.6\times10^{-3},\;2.0\times10^{-5},\;1.7\times10^{-3}$ respectively.

  • PDF

Measurement System of Bidirectional Reflectance-distribution Function (양방향 반사율 분포함수 측정시스템)

  • Hwang, Ji-Soo
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.2
    • /
    • pp.46-52
    • /
    • 2010
  • A theory of bidirectional reflectance-distribution function (BRDF), a newly developed BRDF measurement system, and a method for evaluating the uncertainty of BRDF measurements are presented. The BRDF measurement system which measures BRDF in a wavelength range of (380~1500) nm with an angle range of $(-75{\sim}75)^{\circ}$ was installed. The measurement uncertainties, consisting of correlated terms and uncorrelated terms, were evaluated for the BRDF measurement system, resulting in the relative expanded uncertainty less than 3% (k=2).

Uncertainty evaluation of the analysis of 11-nor-9-carboxy-Δ9-tetrahydrocannabinol in hair by GC-NCI-MS/MS (GC-NCI-MS/MS를 이용한 모발 중 대마 대사체 분석의 측정불확도 평가)

  • Kim, Jin-Young;Lee, Jae-Il;Cheong, Jae-Chul;Suh, Yong-Jun;In, Moon-Kyo
    • Analytical Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.1-9
    • /
    • 2011
  • We described an estimation of measurement uncertainty in quantitative analysis of 11-nor-9-carboxy-${\Delta}^9$-tetrahydrocannabinol (THC-COOH), the metabolite of ${\Delta}^9$-tetrahydrocannabinol, in hair samples by using the bead-assisted liquid-liquid extraction and gas chromatography-tandem mass spectrometric (GC-NCI-MS/MS) detection. Traceability of measurement was established through the use of reference materials, calibrated volumetric tubes, volume measuring devices, and measuring instruments. The analytical results were compared and the different contributions to the uncertainty were evaluated. Inter-day variation was performed by using statistical analysis of several indicative factors. Measurement uncertainty associated with the analyte in real forensic hair samples were estimated using QC data. The major factor of contribution to combined standard uncertainty was inter-day repeatability, while those associated with preparation of analytical standard and also sample of weight were insignificant considering the degree of contribution. Relative uncertainty of relative extended standard uncertainty divided into the measured concentration of the analyte was 17% in a hair sample. The uncertainty of result evaluation will be invaluable to improve quality of the analysis.

A Light Source for Heterodyne Interferomtry using Beat Frequency between Two-axial Modes of a He-Ne Laser (2-종모드 레이저의 비트 주파수를 이용한 헤테로다인 간섭계용 광원 개발)

  • 김민석;김승우
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.02a
    • /
    • pp.92-93
    • /
    • 2001
  • 주파수 안정화 레이저 광원은 10-6 이상의 상대 불확도가 필요한 간섭계에서 널리 쓰이고 있으며 특히 변위 측정 시스템에서는 반드시 쓰이고 있다. 상용화된 많은 변위 측정 시스템은 신호 대 잡음비가 우수하고 광학계의 정렬이 더 쉬운 헤테로다인 방식을 채택하고 있으며 이를 위해서 서로 수직 선형 편광인 다른 주파수의 광을 내보내는 광원이 필요하다. 현재 헤테로다인 변위 측정 시스템에 쓰이고 있는 광원은 이중 주파수 광원을 만드는 방식에 따라 지만 효과(Zeeman effect)를 이용한 지만 레이저(HP사)와 음향-광 변조기(Acousto-optic modulator)를 이용한 이중 주파수 레이저(Zy해사)가 있다. (중략)

  • PDF

사파이어 단결정 기판의 EPD 측정 및 신뢰성 연구

  • Lee, Yu-Min;Kim, Yeong-Heon;Ryu, Hyeon;Kim, Chang-Su
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.317-317
    • /
    • 2012
  • 사파이어는 우수한 광학적, 물리적, 화학적 특성을 가지고 있는 물질 중의 하나이며, 청색 발광특성을 나타내는 GaN와 격자상수, 열팽창 계수가 가장 유사할 뿐만 아니라 가격도 상대적으로 저렴하여 GaN 성장을 위한 기판으로 사용된다. 실제로 사파이어는 프로젝터와 전자파장치, 군사용 장비 등 다양한 분야에 응용되고 있으며, 발광 다이오드(LED)를 위한 기판으로 활용됨으로써 그 수요가 급격히 증가하고 있다. 그러나 사파이어 결정의 성장 중에 생길 수 있는 전위(dislocation)와 적층결함(stacking fault) 등의 결정 결함들은 결정 내에 존재하여 역학적, 전기적 성질에 큰 영향을 미칠 수 있다. 특히 사파이어가 청색 발광소자의 기판으로 사용되는 경우, 사파이어 기판 내부의 결정 결함은 증착되는 박막 특성에 영향을 미치게 된다. 따라서 사파이어의 보다 나은 응용을 위해서는 결함의 형성 메커니즘과 결정 결함의 평가기술 등에 대한 이해가 필요하고, 특히 결함의 정량적 평가 기술의 개발은 사파이어의 상용화에 중요한 핵심요소 중 하나이다. 결정 내 결함이 위치하는 부분은 분자나 원자간의 결합이 약하거나 높은 에너지 상태이므로, 결정의 표면을 적절한 산이나 염기 등을 이용하여 에칭하면 에칭반응은 결정의 전위 위치에 해당하는 부분부터 일어나 결정의 표면에 에치핏을 형성한다. 따라서 결정 표면에 나타나는 에치핏의 개수를 관찰하면 결정의 전위 밀도 파악이 비교적 간단하고, 에칭반응의 이러한 특징은 전위의 정량적 평가에 이용이 가능하다. 본 연구는 4인치 사파이어 조각기판을 수산화칼륨(KOH)으로 습식에칭 후 표면에 나타나는 에치핏의 형성거동과 이의 시간 및 온도 의존성에 관한 연구를 진행하였다. 또한 단결정의 전위밀도를 예측하기 위해 사파이어 조각시편의 단위면적당 에치핏의 개수를 파악하여 에치핏밀도(EPD, etch pid density)를 계산하였고, 값의 불확도(uncertainty)를 계산하여 전위밀도의 신뢰도를 평가하였다. 그 결과, 사파이어 조각시편의 에치핏밀도는 단위면적($cm^2$)당 약 ${\sim}10^2$개로 확인되었고, 이 값은 약 2%의 상대불확도를 가지는 것으로 나타났다.

  • PDF