• Title/Summary/Keyword: 상대구조계수

Search Result 167, Processing Time 0.028 seconds

Seismic Fragility Evaluation of Chimney Structure in Power Plant by Finite Element Analysis (유한요소 해석을 통한 발전소 연돌 구조물의 지진취약도 분석)

  • Kwon, Gyu-Bin;Kim, Jin-Sup;Kwon, Min-Ho;Park, Kwan-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.276-284
    • /
    • 2019
  • Seismic research on bridges, dams and nuclear power plants, which are infrastructure in Korea, has been carried out since early on, but in the case of structures in thermal power plants, research is insufficient. In this study, a total of 192 dynamic analyzes were performed for 16 actual seismic waves and 12 PGAs. As a result, the probability of failure increased as the PGA value increased for each applied seismic wave, but it was different for each seismic wave. As a result, at 0.22G, the ratio of the compressive limit reached to the limit state was 25% and the ratio of the relative displacement reached the limit state was 13%. So, the probability of collapse due to compressive failure Is higher. Therefore, the fragility curve of the chimney which is the subject of this study can be used as a quantitative basis to determine the limit state of the target structure when an earthquake occurs and to be used for the safety design of the thermal power plants.

Performance Evaluation of Seismic Isolation using Ball Bearing (볼 베이링을 이용한 면진장치의 성능평가)

  • Chang, Chun-Ho;Jang, Kwang-Seok;Lee, Young-Seok;Yeo, Sang-Ho
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.71-74
    • /
    • 2011
  • 최근 국제적으로 지진 발생 규모가 증대하고 있으며, 우리나라를 비롯한 많은 나라에서 구조물 및 주요 시설물에 대한 내진설계에 관심이 증대되고 있다. 지진방재는 건물자체의 안전성뿐만 아니라 내부설비 및 소장품에 대한 안전성까지 종합적으로 검토되어야 하며 이를 위한 대책이 필요한 실정이다. 본 연구의 주요목적은 예측 불가한 자연재해인 지진에 대해 일반적인 면진성능을 갖는 기초격리장치로서의 기능을 충실히 수행할 수 있는지를 확인하기 위하여 면진장치를 사용한 구조물의 면진효과를 검증하는 것이다. 또한 설계된 스프링의 탄성계수에 따른 실제 지진 시 응답의 차이를 알아보기 위하여 공진실험 및 진동대 실험을 실시하여 면진테이블 시스템의 면진성능을 평가하였다. 진동대 실험은 미국 "NEBS Requirements"에서 규정하는 요구응답스펙트럼에 상응하는 임의 지진파를 적용하였고 각각 x축과 z축 가진 후, x-y-z 축을 동시에 가진하여 수행하였다. 시험응답스펙트럼(Test Response Spectrum)은 요구응답스펙트럼(RRS)에 포락하도록 시험하여 최대가속도는 x축 방향 가진 시 90%의 감쇠효과가 나타났으며, 3축 방향 가진 시 x축 방향은 58%, y축 방향은 31%의 감쇠효과가 나타났다. 최대상대변위는 설계스트로크 140mm에 대하여 최대 85.54mm의 변위가 발생하여 안정적인 거동을 나타내었다. 본 연구에서 제안한 면진테이블 시스템은 중요 첨단장비 및 문화재 등의 전도 및 파괴를 방지하는 데 효과적일 것으로 판단된다.

  • PDF

Seismic Performance Evaluation of Freeform Diagrid System (비정형 Diagrid System의 내진성능 평가)

  • Ko, Chang-Kyun;Ju, Young-Kyu;Kim, Sang-Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.2
    • /
    • pp.189-198
    • /
    • 2011
  • Many new structural systems have been developed to build free-form structures, which is the new architectural trend for aesthetic beauty. The diagrid system resists both gravity and later loads, with its perimeter-diagonal columns. In the current seismic-design provisions, however, a seismic-performance factor for a new structural system has not yet been provided. ATC-63 provides a new methodology for defining various seismic-performance factors, including the response modification factor. In this paper, nonlinear static and dynamic analyses were conducted for the 3D diagrid frame, with each load applied at $0-180^{\circ}$ degrees. Through these analyses, the seismic performance of the diagrid system was evaluated.

The Effects of $Ta_2O_5$ on Microstructure and Dielectric Properties of $B_a(Zn_{1/3}Ta_{2/3})O_3$ Ceramics. ($Ta_2O_5$ 첨가가 $Ba(Zn_{1/3}Ta_{2/3})O_3$ 세라믹의 미세구조와 유전특성에 미치는 영향)

  • Jeong, Young-Hun;Kim, Min-Han;Son, Jin-Ok;Nahm, Sahn;Park, Jong-Cheol;Kang, Nam-Kee;Lee, Hwack-Joo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.639-643
    • /
    • 2004
  • [ $Ta_2O_5$ ]가 첨가된 $Ba(Zn_{1/3}Ta_{2/3})O_3$[BZT] 세라믹은 1:2 규칙화 정도가 증가하고 $Ba_3Ta_5O_{15}의 이차상이 새롭게 형성된다. $1580^{\circ}C$ 보다 높은 온도에서 소결된 BZT 세라믹은 $Ta_2O_5$를 첨가하면 입자의 성장이 일어나고 액상이 형성된다. 품질계수(Q) 값은 $1580^{\circ}C$ 보다 높은 온도에서 소결할 경우 미량의 $Ta_2O_5$ 첨가만으로도 상당히 증가한다. 상대밀도는 $Ta_2O_5$ 첨가량에 따라 감소하기 때문에 Q값의 증가는 상대밀도와는 무관하다. 반면에, $Ta_2O_5$의 첨가량에 따라 입자의 성장은 증가하였기 때문에 Q값의 향상은 입자크기와 관계가 있음을 알 수 있다. 많은 양의 $Ta_2O_5$ 첨가시 비록 입자 크기가 증가했음에도 불구하고 Q값이 매우 낮은 것을 볼 때, Q값의 감소는 $Ba_3Ta_5O_{15}$ 상의 영향과 낮은 밀도 값에 기인한 것이다.

  • PDF

Estimation of Optimal Slit Length of Perforated Wall below Still Water Level: Single Chamber Condition (정수면 아래 최적 유공부 길이 산정 : 유공 1실 조건)

  • Kim, Young Taek;Lee, Jong In
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.4
    • /
    • pp.327-334
    • /
    • 2013
  • In this study, the optimal slit length of perforated wall with single chamber below the still water level (SWL) is studied through the two dimensional test. The relationship between the reflection coefficient and the shape of structures such as chamber width(B) and slit length(S) are investigated by applying the various wave conditions. The random waves were used for the test by using Bretschneider-Mitsuyasu frequency spectrum. Minimum reflection coefficient is obtained at $B/L_s{\approx}0.15$ condition, this result is different from the regular wave condition. Also the minimum reflection coefficients are measured at $S/H_s{\approx}2.5$. This means that the optimal slit length below the still water level is 2.5 times of the incident wave height.

A Study on Decreasing Effects of Ultra-fine Particles (PM2.5) by Structures in a Roadside Buffer Green - A Buffer Green in Songpa-gu, Seoul - (도로변 완충녹지의 식재구조에 따른 초미세먼지(PM2.5)농도 저감효과 연구 - 서울 송파구 완충녹지를 대상으로 -)

  • Hwang, Kwang-Il;Han, Bong-Ho;Kwark, Jeong-In;Park, Seok-Cheol
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.46 no.4
    • /
    • pp.61-75
    • /
    • 2018
  • This study aims to verify the effect of green buffers, built as urban planning facilities on the reduction of ultra-fine particulate($PM_{2.5}$) and analyze changes in ultra-fine particles by structure, green volume and planting types of wayside green buffers, thus drawing the factors that can be used when green buffers are built to reduce ultra-fine particulate based on the results. This study selected Songpa-gu, and investigated 16 sites on 5 green buffers adjacent to two of Songpa-gu's main roads, 'Yangjaedaero' and 'Songpadaero'. This study divided all the green spaces into three different types-slope type, plain type and mounding type, and analyzed the mean green volume. As a result of measuring the concentration of $PM_{2.5}$, this study found that it was $55.5{\mu}g/m^3$ on average in winter, which was a harmful level according to the integrated environmental index provided by Seoul City, saying that levels above $50{\mu}g/m^3$ may have a harmful effect on sensitive groups of people. Particularly, the concentration of $PM_{2.5}$ was $38.6{\mu}g/m^3$ on average in spring, which exceeded the mean concentration of $PM_{2.5}$ in Seoul City in 2015. The mean concentrations of $PM_{2.5}$ in every investigation spot were $46.6{\mu}g/m^3$ for sidewalks, $45.5{\mu}g/m^3$ for green spaces and $42.9{\mu}g/m^3$ for residential areas, all of which were lower than $53.2{\mu}g/m^3$ for roads, regardless of the season. The concentration of $PM_{2.5}$ for residential areas was the lowest. In the stage of confirming the effect of green buffers, this study analyzed the correlation between the green volume of vegetation and the fluctuated rate of ultra-fine particles. As a result, it was found that the green coverage rate of trees and shrubs was related to the crown volume in every investigation spot but were mutually and complexly affected by each other. Therefore, this study judged that the greater the number of layers of shrubs that are made, the more effective it is in reducing the concentration of $PM_{2.5}$. As for seasonal characteristics, this study analyzed the correlation between the concentration of $PM_{2.5}$ for residential areas in winter and the green coverage rate of each green space type. As a result, this study found that there was a negative correlation showing that the higher the shrub green coverage rate is, the lower the concentration value becomes in all the slope-type, plain-type and mounding-type green spaces. This study confirmed that the number of tree rows and the number of shrub layers have negative correlations with the fluctuated concentration rate of $PM_{2.5}$. Especially, it was judged that the shrub green volume has greater effect than any other factor, and each green space type shows a negative correlation with the shrub coverage rate in winter.

Dynamic Response Analysis of 2.5MW Wind Turbine Gearbox with Flexible Pins (유연핀을 적용한 2.5MW급 풍력발전기용 기어박스의 동응답 해석)

  • Cho, Jin-Rae;Jeong, Ki-Yong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.1
    • /
    • pp.37-44
    • /
    • 2016
  • This study is concerned with the numerical investigation of dynamic characteristics of 2.5MW-class wind turbine gearbox in which the misalignment improvement of plenary gear shafts by the flexible pins and the dynamic impact response are analyzed by the finite element method. The tooth contact between gears is modelled using the line element having the equivalent tooth stiffness and the contact ratio to accurately and effectively reflect the load transmission in the internal complex gear system. The equivalent tooth stiffness is calculated by utilizing the tooth deformation analysis and the impulse torque is applied to the input shaft for the dynamics response characteristic analysis. Through the numerical experiments, the equivalent tooth stiffness model was validated and the misalignment improvement of planetary gear shafts was confirmed from the comparison with the cases of fixed shafts at one and both ends.

Freeze-thaw Resistance Estimation of Concrete using Surface Roughness and Image Analysis (콘크리트의 동결융해 저항성 추정을 위한 표면 거칠기 및 이미지 분석의 적용성)

  • Lee, Binna;Lee, Jong Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.3
    • /
    • pp.1-7
    • /
    • 2018
  • As part of a research dedicated to the field evaluation of the durability of concrete subjected to freezing-thawing, this study analyzes the relationship between the surface roughness and the relative dynamic elastic modulus through image analysis. Four mix compositions with water-to-binder ratios (W/B) of 40%, 50%, 60% and 70% and without AE agent were considered to provoke early freezing. The basic physical properties of the mixes including the relative dynamic elastic modulus and the compressive strength were first evaluated experimentally according to W/B. Then, tests were performed to measure the surface roughness followed by photographs and SEM image analysis. The measured surface roughness tended to increase with larger number of freezing-thawing cycles regardless of W/B. The relative dynamic elastic modulus appeared to increase gradually with the number of cycles for the relatively denser mixes with W/B of 40% and 50%. Besides, the surface roughness increased only at rupture for the mixes with W/B of 60% and 70%. Moreover, the analysis of the photographs of the surface of the mixes with W/B of 40% and 50% revealed that the degradation progressed gradually from the surface with the freezing-thawing cycles. However, for the mixes with W/B of 60% and 70%, apparent change of the surface remained very insignificant until rupture at which damage like cracking could be observed. Consequently, the analysis of surface photograph or the measurement of the surface roughness presented some limitation in assessing the degree of freezing-thawing-induced degradation in case of relatively porous specimens. On the other hand, the photograph and surface roughness appeared to be sufficient for assessing such degradation for the mixes with W/B of 40% and 50%. Accordingly, the image of the surface and the surface roughness are potentially applicable on site for the assessment of freezing-thawing damages in relatively dense mixes.

Preparation of an Inorganic Scintillator Loaded Film for the Measurement of Surface Contamination and its Performance Test (표면오염 측정용 무기섬광 함침 필름의 제조 및 성능 평가)

  • 서범경;이근우;임난주;박진호;한명진
    • Journal of Energy Engineering
    • /
    • v.13 no.2
    • /
    • pp.93-100
    • /
    • 2004
  • The smear media possible to sampling and radiation detection was prepared and evaluated for the surface contamination using indirect method. The films were made by impregnating Cerium Activated Yttrium Silicate (CAYS) in a polysulfone membrane. The membranes used solution as a dimethylformamide (DMF) and methylene chloride (MC), polysulfone as a polymer matrix and CAYS as a inorganic scintillator. The proximity membranes were prepared with single- and double-layered structure. The solidified methods were immersion to the nonsolvent bath such at water and ethanol and solvent evaporation. The measurement of the photon produced by interaction with radiation and inorganic scintillator used a photomultiflier tube (PMT), amplifier, and counter. In the comparison with the low background alpha/beta counter, the counter rate using inorganic scintillator proximity membrane for the $\^$14/C surface contamination was about 50%. Also. the $^3$H counting results revealed that the prepared membranes were efficient to monitor the surface contaminated with the low energy be-ray emitter nuclides.

Analysis of the Structural Characteristics of the Chungnam Display Industry (충남 디스플레이 산업의 구조적 특성 분석)

  • Kim, Dae-Jung;Ko, Kyoung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.620-626
    • /
    • 2021
  • The purpose of this study is to examine the characteristics and industrial structure and to present a future vision through analysis of industrial agglomeration, growth, and industrial efficiency targeting the Chungnam display industry nurtured by regional industrial policies since 2002. The industrial scale and aggregate status were analyzed through the business scale quotient and location quotient, and the growth and pace of structural change in the industry were analyzed through the industrial growth rate and change of industrial structure. Analysis results found the display industry shows its solid status based on industrial agglomeration. The RLQ, added value ratio, and employment coefficient have a relatively high comparative advantage. However, the growth rate has declined, and the pace of structural change has become lower. The regional competitiveness has been deteriorating. It is necessary to develop strategies to help the industry evolve into a convergence display industry to secure competitiveness by forming value chains. The regional industrial policy 'Regional Innovation Growth Plan' should be utilized to foster local industries that consider the regional characteristics and development directions and to promote the shared growth of related subsidiary industries through fostering specialized complexes for materials, parts, and equipment.