• Title/Summary/Keyword: 삽입물

Search Result 573, Processing Time 0.027 seconds

When do we use the Recycling Autograft in Limb Salvage Surgery? (사지구제술에서 언제 재활용 자가골 이식술이 유용한가?)

  • Kim, Jae-Do;Jang, Jae-Ho;Cho, Yool;Kim, Ji-Youn;Chung, So-Hak
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.14 no.2
    • /
    • pp.95-105
    • /
    • 2008
  • Purpose: To identify which is the best procedure in recycling autograft according to the resection & reconstruction type and recycling methods, and so when the recycling autograft is used in limb salvage surgery. Materials and Methods: We have treated fifty-eight patients (34 male, 24 female; age range 5 to 74 years, mean age 36.5 years), who had the malignant musculoskeletal tumors, with recycling autograft (47 patients with extracoporeal irradiation, 11 patients with pasteurization) from December 1995 to February 2006. The resection and reconstruction type was 3 cases with fragmentary, 8 intercalary, 23 rAPC (recycling-Autograft-Prosthesis composite), 18 osteoarticular, 5 total joint and 1 soft tissue (achilles tendon). The result was evaluated by the radiologic union at junctional site, the functional score by musculoskeletal tumor society score and complications according to the resection & reconstruction type and recycling methods. Results: The junctional union was obtained at 15.0 months in extracoporeal irradiation and 12.6 months in pasteurization. Also the mean radiologic union was shown at 6.0 months in fragmentary, 12.8 months in intercalary, 10 months in rAPC, 23.3 months in osteoarticular and 15.6 months in total joint. The functional score was 65.5% in fragmentary, 60.8% in intercalary, 62.8% in APC (except pelvis), 66.0% in osteoarticular and 66.6% in total joint. We have experienced 1 infection, 1 prutrusio acetabuli in pasteurization (18.1%) and other 22 complications (3 deep infections, 8 nonunions, 2 fractures, 2 epiphyseal problems, 5 joint instabilities, 2 local recurrence) in extracoporeal irradiation (46.8%). Also we have experienced 3 complications (3 nonunions) in intercalary (37.5%), 9 complications (4 nonunions, 1 deep infection, 1 periprosthetic fracture, 1 epiphyseal problem, 1 local recurrence, 1 protrusio acetabuli) in rAPC (50.0%), 6 complications (2 deep infections, 2 nonunions, 1 epiphyseal problem, 1 pathologic fracture) in osteoarticular (33.3%), 5 complications (5 joint instabilities) in total joint (100%) and 1 complication(1 local recurrence) in soft tissue (100%). Conclusion: In our experience, according to the resection & reconstruction type fragmentary and intercalary may have several advantages such as good radiologic and functional result and low rate of complication. And it seems that rAPC was available in case which have no sufficient residual bone stock. Also the pasteurization may have more advantages than that of the extracorporeal irradiation.

  • PDF

Preparation and Characteristics of Layered Organo-Vermiculite (충상 유기화질석 제조 및 특성)

  • 김윤섭;고형신
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.148-148
    • /
    • 2003
  • 질석(vermiculite)을 출발물질로 하여 30$0^{\circ}C$에서 4시간 열처리하여 습식분쇄하고 325mesh 이하의 입자를 선별하여 수열조건에서 양이온 계면활성제인 hexadecyl trimethylammonium bromide (C$_{16}$TABr)를 층간 삽입시켜 유기화 질석을 제조하였다. 생성물을 XRD, TGA, FT-IR 등을 이용하여 분석하였고, 합성 및 층간 삽입조건을 조사하였다. 질석에 $C_{16}$TABr를 층간 삽입을 확인하기 위하여 XRD 분석 결과 d-spacing 값이 9.6$\AA$에서 33.5$\AA$으로 증가됨을 확인하였고, 열중량 시험결과 출발물질과 비교하여 유기화 질석은 25%감량이 확인되었다. 위 결과 값으로부터 질석의 유기화 처리로 인하여 층간 간격이 확장되었음을 확인하였다. 일반적으로 층간 간격이 넓을수록 고분자가 층 사이에 보다 쉽게 삽입될 수 있으며 고분자 매트릭스 안에서 층상화합물의 분산 및 박리가 용이해진다. 따라서 본 연구 결과로부터 합성된 유기화 질석은 고분자 나노복합재로 사용 가능성을 제시하고 있다.

  • PDF

Application of the Orally Inserted Guiding Device for the Improved Motion Artifacts of the Cervical Spine MRI (경추부 자기공명영상의 움직임 인공물 개선을 위한 구강내 삽입 유도 기구의 적용)

  • Lee, Jaeheun;Yu, Yunsik;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.317-323
    • /
    • 2014
  • This study aims to suggest and test methods using an orally inserted guiding device in order to improve a motion artifact by involuntary oral motor such as removing one's dentures and swallowing saliva clinically structured cervical spine scan and to make the optimal image by minimizing motion artifact. A cervical spine test was conducted with 30 patients who wore dentures among those who had a cervical spinal disease from January 1, 2014 through June 30, 2014. As for testing methods, after removing denture, T1-TSE-Sagittal, T2-TSE-Sagittal, T1-TSE-Axial and T2-TSE-Axial were obtained in a normal position and a supine position; the orally inserted guiding device was inserted in patients' mouth; and then T1-TSE-Axial and T2-TSE-Axial were retested. As a result, in SNR, T1-TSE-Axial before inserting an orally inserted guiding device was $22.33{\pm}8.59$; T1-TSE-Axial after inserting the orally inserted guiding device was $25.21{\pm}7.93$; T2-TSE-Axial before inserting the orally inserted guiding device was $14.49{\pm}5.74$; and T2-TSE-Axial after inserting the orally inserted guiding device was $16.61{\pm}6.72$. In CNR, T1-TSE-Axial was measured at $0.23{\pm}0.01$ while T2-TSE-Axial at $0.21{\pm}0.01$. As a result of the qualitative analysis, T1-TSE-Axial before inserting the orally inserted guiding device was $3.49{\pm}0.11$; T1-TSE-Axial after inserting the orally inserted guiding device was $3.95{\pm}0.14$; T2-TSE-Axial before inserting the orally inserted guiding device was $3.25{\pm}0.18$; and T2-TSE-Axial after inserting the orally inserted guiding device was $3.68{\pm}0.09$. As a result of using an orally inserted guiding device, the resolution and contrast of the images improved as the patients' involuntary artifact decreased because of removing dentures and swallowing saliva, and it was found that the interpretation of the images and identification of the diseases improved.

Tumor Prosthetic Replacement for the Metastatic Bone Tumors Involving the Proximal Femur (대퇴골 근위부 전이성 종양 환자의 종양 대치물 삽입술)

  • Sung, Ki-Sun;Chang, Moon-Jong
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.13 no.1
    • /
    • pp.48-54
    • /
    • 2007
  • Purpose: To evaluate clinical results of the tumor prosthetic replacement for pathologic fracture of the proximal femur with extensive bony destruction due to metastatic bone tumors. Materials and Methods: From 2005 October to 2006 October, resection of proximal femur and tumor prosthesis replacement was performed for metastatic bone tumors extensively involving trochanteric area in 6 patients. The mean age of overall patients was 61(range, 48~77). Mean clinical follow up was 10.5 months (range, 6~16). Primary tumor consisted with multiple myeloma in 2 patients, lung cancer in 1, breast cancer in 1, transitional cell carcinoma of the renal pelvis in 1, unknown origin in 1 patient. $MUTARS^{(R)}$ proximal femur (Implantcast, Munster, Germany) were used in all cases. The functional evaluation in the lower extremities was performed with Musculoskeletal Tumor Society 1993 scores. The degree of pain relief after surgical treatment was assessed with Visual Analogue Scale (VAS). Results: At the final follow up, all of the patients survived. The mean lower extremities functional score of Musculoskeletal Tumor Society 1993 was 17.8(59.3%)(range, 12~25). VAS was improved to 2.5 from 8.5 after the surgical treatment. Ambulation was encouraged as soon as possible and mean duration after surgery for ambulation was 7.3(range, 3~16) days. Post-operatively, there was no surgical infection, periprosthetic fracture or loosening. Dislocation occurred in one out of six cases. Conclusion: Resection of proximal femur and tumor prosthesis replacement for metastatic bone tumors around proximal femur extensively involving trochanteric area seems to be safe procedure in view of post-operative complication, and effective for functional restoration as well as pain relief. Thus, it is accordant to the treatment principle of the metastatic bone tumors.

  • PDF

Three-Dimensional Printing Technology in Orthopedic Surgery (정형외과 영역에서의 삼차원 프린팅의 응용)

  • Choi, Seung-Won;Park, Kyung-Soon;Yoon, Taek-Rim
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.2
    • /
    • pp.103-116
    • /
    • 2021
  • The use of 3-dimensional (3D) printing is becoming more common, and its use is increasing in the orthopedic surgery. Currently, there are four major methods of using 3D printing technology in orthopedic surgery. First, surgical planning simulation using 3D printing model; second, patient-specific surgical instruments; third, production of customized prosthesis using 3D printing technique; fourth, patient-specific prosthesis produced by 3D printing. The areas of orthopedic surgery where 3D printing technology can be used are shoulder joint, spine, hip and pelvis, knee joints, ankle joint, and tumors. Since the diseases and characteristics handled by each area are different, the method of using 3D printing technology is also slightly different in each area. However, using 3D printing technology in all areas can increase the efficiency of surgery, shorten the surgery time, and reduce radiation exposure intraoperatively. 3D printing technology can be of great help in treating patients with particularly complex and difficult orthopedic diseases or fractures. Therefore, the orthopedic surgeon should make the most of the benefits of the 3D printing technology so that patient can be treated effectively.

The Improvement of Survivability of Fiber Brags Grating Sensors Embedded into Filament Wound Pressure Tanks (필라멘트 와인딩된 복합재료 압력탱크에 삽입된 광섬유 브래그 격자 센서의 생존율 향상)

  • Kang, D. H.;Park, S. W.;Park, S. O.;Kim, C. G.
    • Composites Research
    • /
    • v.18 no.5
    • /
    • pp.1-8
    • /
    • 2005
  • Among many fabrication methods of composite materials, filament winding is the most effective method for fabricating axis-symmetric structures such as pressure tanks and pipes. Filament wound pressure tanks are under high internal pressure during the operation and it has the complexity in damage mechanisms and failure modes. For this reason, it is necessary to monitor the tank through its operation as well as whole fabrication process. A large number of sensors must be embedded into multi points of the tank from its fabrication step for monitoring the whole tank. Fiber optic sensors, especially fiber Bragg grating(FBG) sensors are widely used for various applications because of good multiplexing capabilities. However, we need to develop the embedding technique of FBG sensors into harsh inner environment of the tank far the successful embedment. In this paper, we studied the embedding technique of a number of FBG sensors into filament wound pressure tanks considering multiplexing.