• Title/Summary/Keyword: 사이3

Search Result 14,539, Processing Time 0.044 seconds

Does the New UICC/AJCC TNM Staging System (7th Edition) Improve Assessing Prognosis in Gastric Cancer Compared to the Old System (6th Edition)? (UICC/AJCC 제7판 위암 병기 분류법은 제6판 분류법에 비하여 예후 예측을 증진시키는가?)

  • Ha, Tae-Kyung;Kim, Hyun-Ja;Kwon, Sung-Joon
    • Journal of Gastric Cancer
    • /
    • v.9 no.4
    • /
    • pp.159-166
    • /
    • 2009
  • Purpose: We evaluated the efficacy and prognostic predictability of the $7^{th}$ UICC TNM classification compared to $6^{th}$ UICC TNM classification in patients with gastric cancer. Materials and Methods: Between June 1992 and December 2006, 1,633 patients with gastric cancer who had undergone gastric surgery and who had been analyzed by the $6^{th}$ UICC method were analyzed using the new $7^{th}$ UICC system. Results: Significant differences in 5-year survival rates were observed for $7^{th}$ UICC N0, N1, N2, N3a, and N3b compared to $6^{th}$ UICC. There were no significant differences in 5-year survival rates between T2 and T3. Distinct survival differences were present between stage III (IIIa, IIIb, and IIIc) and stage IV in $7^{th}$ UICC. Significant differences in 5-year survival rates were not expected for Ia versus Ib, Ib versus IIa, and IIb versus IIIa. The survival rates for the same stages were not homogeneously differentiated by $7^{th}$ UICC except for stage IV. Conclusion: The $7^{th}$ UICC classification system is not better able to predict patient survival compared to 6th UICC in patients with gastric cancer, but is better for accurate prognosis of patients with stage IV gastric cancer.

  • PDF

Dynamic Reconstruction Algorithm of 3D Volumetric Models (3D 볼류메트릭 모델의 동적 복원 알고리즘)

  • Park, Byung-Seo;Kim, Dong-Wook;Seo, Young-Ho
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • fall
    • /
    • pp.57-58
    • /
    • 2021
  • 우리는 한정된 공간에 분산하여 위치한 다수 개의 카메라들을 이용하여 생성된 실사 그래픽스 체적 모델 시퀀스 기반 동적 복원 알고리즘을 제안한다. 각 프레임 단위로 생성된 정적 모델의 시퀀스로부터 일정 시간 단위로 키 프레임을 생성한다. 키 프레임과 키 프레임 사이의 모델에 대한 리메싱(Remeshing) 처리를 수행하고 이를 통해 생성된 3D 모델과 키 프레임 사이 특징 점을 획득한다. 획득된 특징 점의 3차원 좌표들 사이의 오차를 최소화 하는 최적화 알고리즘(Solver)을 이용하여 키 프레임 모델과 리 매싱된 모델의 비 강체 정합을 모든 키 프레임 단위로 반복적으로 수행한다. 제안한 정합 방법을 이용하여 생성된 모델과 키 프레임 모델 사이 에러를 비교함으로써 결과를 검증한다.

  • PDF

Study on Relative Stability of Geometrically Constrained Cyclopropylcarbinyl Cation by $^{19}$F-NMR Spectroscopy (풀루오르 19-NMR을 이용한 구조적으로 고정된 사이크로프로필카르비닐 양이온의 상대적 안정도의 비교)

  • Jung Hyu Shin;Bo Hyeon Yoon
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.3
    • /
    • pp.213-219
    • /
    • 1985
  • The relative stability as a function of geometry in rigid cyclopropylcarbinyl cations was examined by $^{19}$F-nmr spectroscopy. 8-p-Fluorophenyl-tricyclo[3.3.1.0$^{2,7}$]octane-8-yl-(I), 9-p-fluorophenyl-tricyclo[3.3.1.0$^{2,8}$]nonane-9-yl (II), and 10-p-fluorophenyl-tricyclo[4.3.1.0$^{2,9}$]decane-10-yl cation(Ⅲ) were prepared from the corresponding carbinols in FSO$_3$H-SO$_2$ClF solution at -120$^{\circ}C$. $^{19}$F-nmr data indicate that the symmetrical bisected geometry of cyclopropane ring for ${\sigma}$-conjugation is a very impotant factor in charge delocalization. However, varied orientation of the bond angle ${\theta}$ within the bisected conformation does not affect the charge delocalization into the cyclopropane ring.

  • PDF

A Study on Realism of a Digital Signage using 3D Hologram (3D홀로그램을 활용한 디지털 사이니지의 사실감)

  • Lee, Young-Woo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.9
    • /
    • pp.1150-1157
    • /
    • 2020
  • It is expected that if a viewer feels the higher realism, it will increase efficiency at 3D hologram. Therefore, the purpose of this study is to analyze the effects of the evaluation factors on realism for digital signage using 3D holograms. For empirical analysis, the evaluation factors were derived and built up hypothesis(The evaluation factors of digital signage using 3D holograms will affect the realism). As a result of the experiment, Hypothesis 1 (Social presence) and 3 (Harmony with the space) were adopted while Hypothesis 2 (Graphic's elaboration) was rejected. Finally, research has shown that in order to improve the realism of digital signage using 3D holograms, the contents should be produced in consideration of presence so that the viewers could feel as if they were actually inside of contents rather than expressed extremely well made higher image resolution. Hence, the 3D hologram contents should be installed in a place where it would fit well with the space around it.

Spinal Nerve Position and Morphometric Analysis with Silicon Molds in the Cadaveric Lumbar Intervertebral Foramen (허리의 척수신경위치와 실리콘을 이용한 척추사이구멍에 대한 형태학적 분석)

  • Kwon, Soonwook
    • Anatomy & Biological Anthropology
    • /
    • v.31 no.4
    • /
    • pp.151-158
    • /
    • 2018
  • The intervertebral foramen is formed by two adjacent vertebrae and an intervertebral disc. Previous studies examining the foramen have been performed using various methods. The author obtained characteristics of the intervertebral foramen based on silicon mold. The author used 18 cadavers and dissected the lumbar intervertebral foramen. First, positional levels of the spinal nerve in the intervertebral foramen were measured. Second, after being removed all tissues covering the intervertebral, bony foramen was filled with melted silicon to mold the cross section. Subsequently, the solidified silicon mold was removed and stamped on a paper. The paper was scanned and analyzed area, perimeter, height and width of the intervertebral foramen on a computer. Area (average, $9.43mm^2$) and perimeter (average, 48.02 mm) did not show any statistical significant pattern for any lumbar vertebral levels. However, the height and width significantly differed at the fifth lumbar vertebra, which had the shortest height (the fifth, 13.00 mm; average, 15.78 mm) and longest width (the fifth, 8.61 mm; average, 7.87 mm), although there were similar patterns in case of area and perimeter of the first to fourth lumbar vertebra. Height had a decrease tendency while width had an increase tendency both from the second to fifth lumbar vertebra. Spinal nerves went through near the intervertebral disc level from the first to fourth lumbar vertebra, although they passed below the disc at the fifth level. This study provides a different view of methodology for the 3-dimensional aspect for the intervertebral foramen. Results of this study may indicate that height and width of the intervertebral foramen changed along all lumbar vertebral levels; nevertheless, area and perimeter of the intervertebral foramen remained constant.

코로나 방전을 이용한 하이브리드 사이클론 집진 장치 특성 연구

  • Choe, Seong-Chang
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.259-260
    • /
    • 2012
  • 산업화가 발달됨에 따라 대기 오염 물질은 점차 증가하고 있는 추세에 있고 특히 기름 및 석탄 연소 보일러, 자동차, 제철, 시멘트 플렌트, 소각로 등은 미세 분진을 발생시키는 주원인이 되어 왔다. 최근 대기환경법은 오염 분진의 중량 규제로부터 $10{\mu}m$ 미만의 PM10에서 $2.5{\mu}m$ 미만의 PM2.5의 미세 분진에 대한 규제로 점차 심화되고 있으나, 이러한 미세분진은 고전적인 제거 방법으로는 매우 어려우며 고가의 HEPA 필터를 사용하여야 한다. 한편 코로나 방전을 이용하는 전기 집진은 미세 먼지 제거에 매우 효율적이어서 $1{\mu}m$ 미만의 미세 분지도 99%까지 제거가 가능하다는 장점이 있지만 입자크기가 클 경우에는 효율이 떨어지는 단점이 있다. 한편 사이클론 집진기는 매우 오래전부터 개발되어 사용되어 왔는데 가격이 저렴하고 운영비가 적게 들며 $10{\mu}m$ 이상의 먼지는 99% 이상 제거가 가능하여 산업현장에서 오랜 기간 사용되어 왔지만 입자크기가 $10{\mu}m$ 미만으로 가면 집진율이 급격히 떨어지는 단점을 가지고 있다. 본 연구에서는 기존의 사이클론 집진기의 구조를 기본으로하여 사이클론 집진기 내부에 플라즈마 방전을 설치하여 원심력에 의한 집진과 코로나 방전에 의한 전기 집진을 동시에 수행할 수 있도록 하이브리드 사이클론 집진기를 제작하였다. 제작된 사이클론 집진기는 직경 30 cm 높이 120 cm의 사이클론 구조를 가지고 있으며 1 hp의 터보송풍기를 장착하여 $20m^3$/min 이상의 유량을 처리할 수 있도록 설계 제작되었다. 제작된 하이브리드 사이클론 집진기의 성능을 평가하기 위하여 $10m^3$의 체적을 가지는 테스트 챔버 내부에 사이클론 집진기를 설치하고 향을 태워 미세 먼지를 발생시킨 후 다양한 조건에서 집진 성능을 측정하여 보았다. 미세 먼지의 경우 사이클론을 작동시키지 않아도 테스트 챔버 벽면에 흡착되어 초기에는 급격히 감소하는 경향을 보여주나 일정 시간이 경과한 후에는 매우 느리게 감소하는 현상이 관찰 되었다. 코로나 방전을 하지 않고 오존 파괴기에 활성탄만 충진한 상태에서 사이크론을 작동시킬 경우 지속적으로 천천히 감소하는 경향을 보여주었으며, 코로나 플라즈마를 방전시킨 경우 미세 먼지는 HEPA filter를 장착한 것보다도 조금 빠르게 미세먼지를 제거하였다. 챔버 내부의 미세먼지가 초기 값의 1/10에 도달하는 시간은 코로나 방전 전류가 증가할수록 짧아지는 경향을 보여주었으며 최적 조건에서 100초 이내에 90% 이상 제거가 가능하였다. 하이브리드 사이클론 집진기는 집진 뿐 만 아리라 VOC 성분도 분해가 가능하여 유해물질을 제거하는 능력이 있다. 유해 가스 제거 능력을 실험하기 위하여 분진제거 실험에 사용된 챔버 안에 아세톤을 증발시켜 50 ppm이 되도록 한 후 다양한 조건에서 유해물질 제거 실험을 수행하였다. 미세먼지와는 달리 장비를 작동하지 않을 경우 매우 느리게 아세톤 농도가 감소하였다. 이는 미세 먼지와는 달리 흡착이 발생하지 않고, 측정 챔버 자체가 완전한 밀폐가 이루어지지 않아 자연적으로 조금씩 외부로 누출되기 때문으로 판단된다. 코로나 플라즈마만 방전시켰을 경우 초기 농도의 80%가 제거되는데 걸리는 시간은 약 28분 정도로 코로나 플라즈마가 VOC 제거에 효과가 있음은 확인하였으나 제거율이 그리 높지 않음을 알 수 있었다. 한편 오존 파괴를 위해 활성탄으로 충진 된 오존파괴기를 통과시킨 경우는 약 12분 경과 후 80%가 제거됨을 확인할 수 있었으나 그 이후에는 VOC의 감소가 매우 느리게 진행됨을 알 수 있었다. 한편 활성탄 대신 $MnO_2$ 복합촉매로 충진 된 오존파괴기를 통과한 경우 약 3분 정도 경과 후 80%의 아세톤이 제거됨을 관찰할 수 있었으며 코로나 플라즈마를 작동시키면서 $MnO_2$ 복합촉매로 충진 된 오존파괴기를 통과시킨 경우 약 2분 정도 경과 80% 이상의 아세톤이 제거되어 코로나 플라즈마와 복합촉매를 사용할 경우 VOC 성분이 효과적으로 제거됨을 알 수 있었다.

  • PDF

디지털사이니지 기술의 국내.외 표준화 동향

  • Jeong, Hyo-Taek;Yun, Gi-Song;Son, Uk-Ho
    • Information and Communications Magazine
    • /
    • v.30 no.9
    • /
    • pp.25-32
    • /
    • 2013
  • 현재 현장에 설치되어 운용되고 있는 대부분의 디지털사이니지는 독자적인 설계와 구현으로 개발되었기 때문에 다른 시스템과 연동이나 상호 운용하기에는 많은 어려움이 있다. 향후 웹 기반의 개방형 디지털사이니지가 주류를 이룰 것으로 예상됨에 따라, 다양한 서비스나 단말장치와 연동할 수 있는 상호 운용성을 갖춘 솔루션을 위한 기술 표준화 작업이 활발하게 진행될 것으로 예상된다. 최근 몇 년 전부터 ITU-T, POPAI, W3C 등을 중심으로 디지털사이니지 기술 표준화가 진행되고 있으며, 국내에서도 디지털사이니지 산업이 성장하면서 표준화에 대한 관심이 고조되고 있다. 이에 본고에서는 ITU-T, POPAI, W3C, 일본 등 해외에서 행해지고 있는 최근의 표준 활동과 TTA를 중심으로 한 국내의 표준 활동을 소개한다.

Artificial teeth displacement of monolithic complete denture manufactured by 3D printer and milling machine (3차원 적층 출력과 밀링에 의해 제작된 일체형 의치의 인공치 변위 평가)

  • Kwak, Young-Hun;Lee, Sea-Han;Lee, Gyeong-Je;Kim, Hee-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.394-402
    • /
    • 2017
  • Purpose: The purpose of this study is to evaluate the displacement of artificial tooth of monolithic complete denture manufactured by milling and 3D printing method in which the denture base and the artificial teeth are simultaneously made. Materials and methods: Twelve upper and lower complete dentures for each were made by milling and 3D printing method. Group Up and Group Lp are a group of upper and lower dentures made by printing, and Group Um and Group Lm are denture groups made by milling. Group Uc and Group Lc are is a group of finally designed upper and lower dentures respectively. Measurements were performed between both central incisors (AB, ab), both canines (CD, cd), both first molars (EF, ef), between an incisor and a first molar (AE, ae), and between incisor and lingual point (AG, ag) for each upper and lower denture. Results: AG and ag value between printed dentures and original ones as well as between milled dentures and original ones showed a statistically significant difference (One-way ANOVA, P<.05) in both lower and upper monolithic dentures. In the lower monolithic ones, ab, cd and ef value revealed a significant difference between Group Lp and Group Lm (One-way ANOVA, P<.05). Conclusion: Dentures made using milling or 3D printers revealed statistically significant difference compared with those of original data. However, it showed clinically very accurate reproducibility.

목성의 고분산 3 Micron 스펙트럼 3.00 - $3.10{\mu}m$ 사이에 존재하는 미확인 분광선

  • Son, Mi-Rim;Kim, Sang-Jun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.89.2-89.2
    • /
    • 2010
  • 우리는 목성의 emission과 absorption 스펙트럼에 영향을 미치는 인자를 알아보고 목성의 대기구조를 연구하기 위하여 2006년 4월 18일부터 8월22일 사이 중 7일간 United Kingdom Infrared Telescope(UKIRT)의 고분산분광기 CGS4(R=37,000)를 이용하여 관측한 목성의 $2.86-3.53{\mu}m$ 분광관측 자료를 분석하였다. 관측자료의 분석에는 $CH_4,\;CH_3D,\;NH_3,\;C_2H_2,\;C_2H_6,\;PH_3$, HCN의 분광선 뿐만 아니라 구름과 Haze의 영향도 포함하는 대기모델을 사용하였다. 대부분의 관측된 분광선은 모델링을 통하여 얻은 synthetic spectrum과 일치하였으나 3.00 에서 $3.10{\mu}m$사이에서 일치하지 않는 다섯 개의 미확인 분광선을 발견하였다. 이들은 각각 $3.003{\mu}m$ 근처와 3.0505, 3.0735, $3.0865{\mu}m$ 그리고 $3.0935{\mu}m$에서 나타나며, 미확인 분광선들이 Seo et al.(2007)이 언급한 태양의 적외선 흡수선에 의해서 나타나는 분광선이 아님을 보였다. 우리는 이 미확인 분광선들을 설명할 수 있는 가능한 분자들을 제시 하고자 한다.

  • PDF