• Title/Summary/Keyword: 사용전 평가

Search Result 2,653, Processing Time 0.037 seconds

Proposal for Estimation Method of the Suspended Solid Concentration in EIA (환경영향평가에서 부유사 농도 추정 방법 제안)

  • Choo, Tai Ho;Kim, Young Hwan;Park, Bong Soo;Kwon, Jae Wook;Cho, Hyun Min
    • Journal of Wetlands Research
    • /
    • v.19 no.1
    • /
    • pp.30-36
    • /
    • 2017
  • SS(Suspended Solid) concentration by soil erosion into river at normal and flood season should be measured. However, to present the variation of SS due to various development project such as EIA(Environmental Impact Assessment), River Master Plan, and so on, it is necessary to estimate not measure SS, but there are not exist how to estimate SS. In the present study, therefore, we propose the hydrologic method of estimating SS concentration using the results of particular frequency flood discharge and sediment discharge by RUSLE method. SS consists of silty and clay soil and colloid particle etc. However, in the present study, silty and clay soils of sediment discharge except send set up SS standards. The flow discharge to estimate SS concentration are 1~2 years for normal season, 30~100 years for flood season. Meanwhile, analysis software for probable rainfall uses Fard2006, probable rainfalls under 2-year frequency are estimated using rainfall data and frequency factor of Gumbel distribution. The results of estimating SS concentration using runoff volume by sediment and flow discharges of silty and cray soils as above method show that reliable level of SS concentration is considered in predevelopment of natural condition and under development of barren condition. Especially, SS concentration takes notice that the value of sediment discharge makes a huge difference according to channel slope, it was confirmed that the value obtained by dividing the SS concentration by the channel slope is relatively constant even though the topographical factors are different. Therefore, if the present study will be proceeded for various watersheds, it will be developed as estimation method of SS concentration.

The Design and Fabrication of Conversion Layer for Application of Direct-Detection Type Flat Panel Detector (직접 검출형 평판 검출기 적용을 위한 변환층 설계 및 제작)

  • Noh, Si-Cheol;Kang, Sang-Sik;Jung, Bong-Jae;Choi, Il-Hong;Cho, Chang-Hoon;Heo, Ye-Ji;Yoon, Ju-Seon;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.73-77
    • /
    • 2012
  • Recently, Interest to the photoconductor, which is used to flat form X-ray detector such as a-Se, $HgI_2$, PbO, CdTe, $PbI_2$ etc. is increasing. In this study, the film layer by using the photoconductive material with particle sedimentation was fabricated and evaluated. The quantization efficiency of the continuous X-ray with the 70 kVp energy bandwidth was analyzed by using the Monte Carlo simulation. With the results, the thickness of film with 64 % quantization efficiency was 180 ${\mu}m$ which is similar to the efficiency of 500 ${\mu}m$ a-Se film. And $HIg_2$ film has the high quantization efficiency of 74 % on 240 ${\mu}m$ thickness. The electrical characteristics of the 239 ${\mu}m$ $Hgl_2$ films produced by particle sedimentation were shown as very low dark current(under 10 $pA/mm^2$), and high sensitivity(19.8 mC/mR-sec) with 1 $V/{\mu}m$ input voltage. The SNR, which is influence to the contrast of X-ray image, was shown highly as 3,125 in low driving voltage on 0.8 $V/{\mu}m$. With the results of this study, the development of the low-cost, high-performance image detector with film could be possible by replacing the film produced by particle sedimentation instead to a-Se detector.

RELATIONSHIP OF DENTAL ANXIETY BETWEEN CHILD AND PARENT DURING DENTAL VISIT (치과 방문 시 어린이와 부모의 치과 불안도의 상관 관계)

  • Kim, Sung-Hee;Kim, Jae-Gon;Yang, Yeon-Mi;Kwon, Byoung-Woo;Baik, Byeong-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.2
    • /
    • pp.370-376
    • /
    • 2005
  • In children, dental anxiety of dental treatment has been recognized as a source of problems in patient man agement for many years. Dental anxiety can be causes of negative cooperation, cancel and avoid of dental treatment. Therefore, dentist and dental team should recognize of child's dental anxiety as early as possible and manage appropriately. In previous studies, it is reported that parental dental anxiety affect dental anxiety and cooperation of their child. And it is parental decision which results in a child's visit to the dentist, rather than a child's decision in most cases. Therefore, it is important to identify the relationship of dental anxiety between child and parent. We estimated child's dental anxiety before dental treatment using Venham Picture Scale that is useful even a very young child and parental dental anxiety using Corah's dental anxiety scale. Then, two values above were compared. Child's cooperation, temperament, sex, age, parental education were estimated and compared with dental anxiety, too. The results were as follows: 1. There are positive relationship of dental anxiety between child and parent with the correlation analysis(P<0.02). 2. There are negative relationship of child's dental anxiety and child's cooperation with the correlation and regression analysis(P<0.001). 3. Low anxiety group has lower mean value of four temperament item with the Student's t-test. But, there is no statistical differences(P>0.1). 4. Girl and younger group have higher mean value of dental anxiety than boy and older group with the Student's t-test(P<0.001). 5. Low educated parents have higher mean value of dental anxiety than high educated parents with the Student's t-test(P>0.1).

  • PDF

멕시코 로얄 은광산 잠재성 평가

  • Heo, Cheol-Ho;Kim, Ui-Jun
    • 한국지구과학회:학술대회논문집
    • /
    • 2010.04a
    • /
    • pp.108-109
    • /
    • 2010
  • IMPACT Silver 주식회사는 Zacualpan 프로젝트의 Royal Mines(이하 로얄 광산)을 인수했다. $124.5\;km^2$에 해당하는 지역의 소유권은 두 개의 멕시코 사기업으로부터 가행중인 광산의 채굴권 구입과 운영 중인 기반시설의 임대를 조건으로 한다. 프로젝트 지역은 멕시코시티로부터 남서방향으로 100 km와 Taxco Silver 광산으로부터 북서방향으로 25 km 떨어진 지점에 위치한다. 기반시설은 비포장 도로, 충분한 전력과 물의 공급 및 숙련공들을 갖추어 우수한 평가를 받고 있다. 소유권은 멕시코인의 개인소유 하에서 무한한 매장량 혹은 자원량을 갖고 운영된 채광과 가공시설을 인수하는 것이다. 소유권 지역을 대상으로 한 IMPACT Silver사의 주 탐사목적은 이미 알려진 광화대의 확장을 위한 잠재성 평가와 다른 지역에서 신규 광상의 유망지역을 발견하는 것이다. Zacualpan 프로젝트의 로얄 광산은 남동 Guerrero terrane의 북부에 위치한다. Teloloapan subterrane은 주로 저변성 녹색편암상으로 구성된 쥬라기 후기에서 백악기 초기의 화산성 퇴적층으로 구성된다. 대부분의 유망지역은 Lower Villa de Ayala층의 중성 내지 염기성 화산성 쇄설암을 모암으로 한다. 다상의 변성작용은 지역 전반에 걸쳐 나타나고, Zacualpan 광산지역에서 수반되는 광화작용을 규제한다. Zacualpan 광산지역은 Sierra Madre del Sur로 알려진 유망 광화대에 해당한다. 이 지역은 화산성 괴상 황화광상과 천열수 맥상광상이 우세하다. 대부분의 천열수 광화작용은 3.2-3.8억 년 전 마그마의 생성이 활발한 판구조 체제 동안 발생하였다. 역사적으로 가장 주요한 지역은 Lipton Vein이다. 현재 Zacualpan 지구에서 채광량은 은 200-500 g/t 정도로 보고되고 있다. 일부 지역은 고품위 은 광화작용(은 1,000 g/t 이상)을 수반하고 있으며, 이는 탐사의 주 타겟이 되고 있다. Zacualpan에서 은 광화작용은 은이 부화된 중유황 천열수 맥상광상으로 상당히 유명하다. Fresnillo, Pachuca 및 Taxco 광산을 포함한 멕시코 소유의 대규모의 잘 알려진 광산들이 이에 해당한다. 이러한 광산들은 부산물로서 금, 아연, 연이 생산된다. 이러한 광상들은 맥상과 각력상 및 산점상 또는 망상세맥의 형태로 산출된다. 광화작용은 석영과 탄산염 맥 내에 주로 황철석과 다양한 섬아연석, 방연석, 은 혹은 금 광물들을 수반한다. 경제성을 갖는 광화작용의 수직적인 연장은 평균적으로 대략 300 m이고, 멕시코 중부에 위치한 Fresnillo의 광화작용은 100 m에서 960 m의 연장을 갖는 것으로 알려져 있다. 아주 오랫동안 Zacualpan에서 광산관계자의 관측과 IMPACT Silver에서 최근 작업의 결과를 토대로, Zacualpan 광산지역의 탐사모델은 새로운 광상의 탐사를 위한 가이드로서 개발되었다. Zacualpan 광산지역에서 가장 높은 경제성을 갖는 광화작용은 북서와 남북방향의 맥 구조를 따라 수반된다. 이러한 맥 구조들은 종종 이 지역을 가로질러 수 km까지 추적되지만, 경제성을 갖는 광화작용은 맥 구조를 따라서 구조적으로 유리한 지역에서 부광대를 형성한다. 부광대를 형성하기 위한 가장 유리한 구조적 지역은 북서와 남북방향으로 발달한 맥 구조들이 교차하는 지역이다. 지난 30년간 채광된 주요 부광대는 폭이 2-6 m 이고 수평연장은 30-150 m 그리고 수직연장은 230-300 m에 이른다. 가장 높은 생산량을 보이는 부광대는 남북방향의 이차 맥들이 Guadalupe 광산의 Lipton 맥을 가로지르는 지역에서 발달한다. 남동쪽으로 현재 Compadres 광산의 Silver Shoot No. 1으로부터 고품위 은을 생산하는 지역은 북서방향의 San Agustin 맥이 북향의 Cometa Navideno 맥에 의해 절단되는 지역에서 산출한다. 모암은 광화작용을 규제하는 또 다른 중요한 요소이다. 광산지역에서 경제성을 갖는 모든 광화작용은 중성 내지 염기성 화산암 특히 안산암과 관련 모암에 배태된다. 부광대가 셰일 혹은 편암으로 전이되는 지역에서, 맥들은 소규모의 세맥으로 나뉘어 진다. Zacualpan의 전형적인 천열수 광상에서 부광대는 상부로 가면서 은의 함량이 증가하고, 하부로 가면서 연 아연의 함량이 증가하는 수직적 대상을 보인다. 금의 함량 변화는 보다 예측이 어려우나 상당히 중요하다. Zacualpan 광산지역의 탐사모델에 사용된 토양 채취, 정밀지도제작, 트렌치 및 시추탐광은 현재 IMPACT Silver사가 이 지역을 대상으로 한 가장 효율적인 탐사방법으로 입증되었다. Zacualpan 프로젝트의 로얄 광산은 하루 500 톤을 제련하는 기반시설과 수반된 채굴권을 갖는 가행 광산들을 포함한다. 현재 IMPACT Silver사는 두 곳의 타겟 지역에서 정밀지도제작, 토양 및 암석 채취, 12공 총 1866 m의 시추탐광에 의한 사전조사로 구성된 4 단계 탐사를 수행했다. 암석 1,953개, 토양 1,631 개, 389 개의 시추코어 시료가 채집되고 분석되었다. 이러한 작업은 추가탐사를 요구하는 수많은 유망 광화대를 규명했다. Compadres 광산에서 현재 가행중인 지하갱 시료는 레벨 1에서 0.9 m의 폭을 갖는 광체에서 은 680 g/t과 금 0.3 g/t, 레벨 3에서 1.67 m의 폭을 갖는 광체에서 은 12,591 g/t과 금 12.07 g/t의 품위를 갖는 것으로 나타났다. 레벨 1에서 3까지 2-3 m의 폭과 30-40 m 연장으로 채광되었다. 시추탐광은 고품위를 갖는 몇몇의 중첩된 맥을 발견했다. Compadres 광산에서 남동방향으로 200 m지점에 위치한 Soledad 지역에서 5 개의 시추공으로부터 동일 맥 시스템이 발견되었고, 고품위 부광대의 상부로 간주되는 몇몇 중요 지점이 발견되었다. 초기 단계의 탐사는 유망 시추탐광 지역인 중간정도 내지 고품위 유망 광화대를 규명했다.

  • PDF

Can 3-year Disease-free Survival be Substituted for 5-year Overall Survival in Curatively Resected Gastric Cancer? (치유 절제술을 받은 위암 환자에서의 3년 무병생존이 5년 전체생존을 대치할 수 있는가?)

  • Kwon, Sung-Joon;Kim, Hyoung-Ju;Kim, Mi-Kyung
    • Journal of Gastric Cancer
    • /
    • v.5 no.3 s.19
    • /
    • pp.174-179
    • /
    • 2005
  • Purpose: The 5-year survival rate is the most useful parameter for evaluating the effect of management on most malignant tumors. Recurrence after a curative resection for gastric cancer occurs mostly within 3 years of the operation, which caused us to evaluate whether a 3-year disease-free survival (3DFS) can be substituted for a 5-year overall survival (5OS). Materials and Methods: We reviewed the medical records of 656 consecutive patients who had undergone a curative resection for gastric cancer To assess whether 3DFS represents 5OS, we used a simple linear regression with survival probability calculated by using the survival function. Results: Recurrence was found in 175 cases during the follow-up periods. The accumulative frequencies of recurrence at postoperative 1 year, 3 years, and 5 years were 46% (81 cases), 89% (156 cases), and 97% (170 cases), respectively. The correlation coefficient (r) and the coefficient of determination $(r^2)$ between 3DFS and 5OS were 0.87 and 0.76, respectively, and the regression equation was $5OS=0.18+(0.80{\times}3DFS)$. The r and $R^2$ according to the type of recurrence were 0.89 and 0.80 in peritoneal seeding, 0.88 and 0.78 in hematogeneous metastasis, and 0.86 and 0.73 in local recurrence, respectively. The r (0.77) and $r^2$ (0.60) were relatively lower in low stages (stage I and II) compared to r (0.88) and $r^2(0.77)$ in high stages (stage III and IV). Conclusion: The 3DFS is an excellent predictor of 5OS. Therefore, if we use the former as the treatment evaluating method, 2-year time reduction in assessing and reporting treatment results is expected.

  • PDF

Correlation Analysis of Diffusion Metrics (FA and ADC) Values Derived from Diffusion Tensor Magnetic Resonance Imaging in Breast Cancer (유방암의 확산텐서 자기공명 영상에서 유도된 확산 지표(FA, ADC) 값의 연관성 분석)

  • Lee, Jae-Heun;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.755-762
    • /
    • 2018
  • The purpose of this study was to compare the FA(faractional anisotropy) and ADC(apparent diffusion coefficient) values, which were derived from diffusion tensor imaging in breast cancer patients. The diffusion gradient used in this study was derived from quantitative diffusion indices using 20 directions(b-value, 0 and $1,000s/mm^2$). Quantitative analysis was analyzed using Pearson's correction and qualitative analysis using for correction coefficients. As a result, $FA_{min}$, $FA_{mean}$ and $FA_{max}$ were $0.098{\pm}0.065$, $0.302{\pm}0.142$ and $0.634{\pm}0.236$, respectively(p > 0.05). The $ADC_{min}$, $ADC_{mean}$ and $ADC_{max}$ were $0.741{\pm}0.403$, $1.095{\pm}0.394$ and $1.530{\pm}0.447$, respectively(p > 0.05). The $FA_{min}$, $FA_{mean}$, and $FA_{max}$ mean values were $0.132{\pm}0.050$, $0.418{\pm}0.094$, and $0.770{\pm}0.164$ for Category 6 and Kinetic Curve Pattern III, respectively. $ADC_{min}$, $ADC_{mean}$, and $ADC_{max}$ were $0.753{\pm}0.189$, $1.120{\pm}0.236$, and $1.615{\pm}0.372$, respectively. Quantitative analysis showed negative correlation between $ADC_{mean}-FA_{mean}$ and $ADC_{max}-FA_{max}$(p = 0.001, 0.003). The qalitative analysis showed ADC 0.628(p = 0.001), FA 0.620(p = 0.001) in the internal evaluations, ADC 0.677(p = 0.001), FA 0.695(p = 0.001) in external evaluations. In conclusion, based on the morphological examination, time to signal intensity graph is the form of wash-out(pattern III) in the dynamic contrast enhance examination, As a result, the $ADC_{mean}$ $1.120{\pm}0.236$ and $FA_{mean}$ values were $0.032{\pm}0.142$ with a negative correlation (Y=1.44-1.12X). Therefore, If we understand the shape of time to signal intensity graph and the relationship between ADC and FA, It will be a criterion for distinguishing malignant diseases in breast cancer.

A Study on the Treatment of Combine Electron Beam in the Treatment of Breast Cancer Tumor Bed (유방암 Tumor bed 치료 시 혼합 전자선 치료 방법에 대한 고찰)

  • Lee, Geon Ho;Kang, Hyo Seok;Choi, Byoung Joon;Park, Sang Jun;Jung, Da Ee;Lee, Du Sang;Ahn, Min Woo;Jeon, Myeong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.51-56
    • /
    • 2019
  • Purpose: The usefulness of using single-electron radiation for secondary radiotherapy of breast cancer patients after surgery is assessed and the use of a combine of different energy. Methods and materials : In this study, 40 patients (group A) using energy 6 MeV and 9 MeV, and 19 patients (group B) using a combine of 9 MeV and 12 MeV were studied among 59 patients who performed secondary care using combine electronic radiation. Each patient in each group, 6 MeV, 9 MeV, Combine(6 MeV / 9 MeV) and 9 MeV, 12 MeV, Combine (9 MeV / 12 MeV) were developed in different ways, and the maximum doses delivered to the original hospital, D95, D5, and $V_3$, $V_5$, $V_{10}$ were compared. Result: The D95 mean value of Group A treatment plan was $785.33{\pm}225.37cGy$, $1121.79{\pm}87.02cGy$ at 9 MeV, and $1010.98{\pm}111.17cGy$ at 6 MeV / 9 MeV, and the mean value at 6 MeV / 9 MeV was most appropriate for the dose. The mean values of the low dose area $V_3$ and $V_5$ in the lung of the breast direction being treated were $3.24{\pm}3.49%$ and $0.72{\pm}1.55%$ at 6 MeV, the highest 9 MeV at $7.25{\pm}4.59%$, $3.07{\pm}2.64%$, the lowest at 6 MeV. Maximum and average lung dose was $727.78{\pm}137.27cGy$ at 6 MeV / 9 MeV, $49.16{\pm}24.44cGy$, highest 9 MeV at $998.97{\pm}114.35cGy$, $85.33{\pm}41.18cGy$, and lowest 6 MeV at $387.78{\pm}208.88cGy$, $9.27{\pm}6.60cGy$. The value of $V_{10}$ was all close to zero. Group B appeared in the pattern of Group A. Conclusion: Relative differences in low-dose areas of the lungs $V_3$ and $V_5$ were seen and were most effective in the dose transfer of tumor bed in the application of combined energy. It is thought that the method of using electronic energy in further radiation treatments for breast cancer is a more effective way to use the energy effect of limiting energy resources, and that if you think about it again, it could be a little more beneficial radiation treatment for patients.

The CH3CHO Removal Characteristics of Lightweight Aggregate Concrete with TiO2 Spreaded by Low Temperature Firing using Sol-gel Method (Sol-gel법으로 이산화티탄(TiO2)을 저온소성 도포시킨 경량골재콘크리트의 아세트알데히드(CH3CHO) 제거 특성)

  • Lee, Seung Han;Yeo, In Dong;Jung, Yong Wook;Jang, Suk Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.2A
    • /
    • pp.129-136
    • /
    • 2011
  • Recently studies on functional concrete with a photocatalytic material such as $TiO_2$ have actively been carried out in order to remove air pollutants. The absorbtion of $TiO_2$ from those studies is applied by it being directly mixed into concrete or by suspension coated on the surface. When it comes to the effectiveness, the former process is less than that of the latter compared with the $TiO_2$ use. As a result, the direct coating of $TiO_2$ on materials' surface is more used for effectiveness. The Surface spread of it needs to have a more than $400^{\circ}C$ heat treat done to stimulate the activation and adhesion of photocatalysis. Heat treat consequently leads hydration products in concrete to be dehydrated and shrunk and is the cause of cracking. The study produces $TiO_2$ used Sol-gel method which enables it to be coated with a low temperature treat, applies it to pearlite using Lightweight Aggregate Concrete fixed with a low temperature treat and evaluates the spread performance of it. In addition to this, the size of pearlite is divided into two types: One is 2.5 mm to 5.0 mm and the other is more than 5.0 mm for the benefit of finding out the removal characteristics of $CH_3CHO$ whether they are affected by pearlite size, mixing method and ratio with $TiO_2$ and elapsed time. The result of this experiment shows that although $TiO_2$ produced by Sol-gel method is treated with 120 temperature, it maintains a high spread rate on the XRF(X ray Florescence) quantitative analysis which ranks $TiO_2$ 38 percent, $SiO_2$ 29 percent and CaO 18 percent. In the size of perlite from 2.5 mm to 5.0 mm, the removal characteristic of $CH_3CHO$ from a low temperature heated Lightweight concrete appears 20 percent higher when $TiO_2$ with Sol-gel method is spreaded on the 7 percent of surface. In other words, the removal rate is 94 percent compared with the 72 percent where $TiO_2$ is mixed in 10 percent surface. In more than 5.0 mm sized perlite, the removal rate of $CH_3CHO$, when $TiO_2$ is mixed with 10 percent, is 69 percent, which is similar with that of the previous case. It suggests that the size of pearlite has little effects on the removal rate of $CH_3CHO$. In terms of Elapsed time, the removal characteristic seems apparent at the early stage, where the average removal rate for the first 10 hours takes up 84 percent compared with that of 20 hours.

$^{18}F$-FDG Colonic Uptake by Oral Anti-Diabetic Drugs Including Metfomin in PET/CT Scan (PET/CT 검사에서 Metformin 성분의 항 당뇨약제에 의한 대장에서의 $^{18}F$-FDG 섭취에 관한 연구)

  • Kim, Sang-Gyu;Park, Hoon-Hee;Kim, Jung-Yul;Bahn, Young-Kag;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.50-54
    • /
    • 2010
  • Purpose: The uptake of $^{18}F$-FDG is often observed in normal cell of colon to patients who have non-insulin-dependent diabetes mellitus and had taken anti-diabetic drugs including Metformin in PET/CT scan. In this study, the region of colon was compared between the patients who took anti-diabetic drugs including Metfomin and other patients who took the other anti-diabetic drugs through SUV measurements. Materials and Methods: A hundred eighty patients were studied. 120 patients who have non-insulin-dependent diabetes mellitus (Including Metformin: 60, Excluding Metformin: 60) and 60 patients as a control group were composed. The patient fasted at least 6 hours before receiving an intravenous injection of 370-592 MBq (10-16 mCi) of $^{18}F$-FDG. Scanning from the base of the skull though the mid thigh was performed using the Discovery STe PET/CT Equipment (GE Healthcare, Milwaukee, WI, USA). The highest uptake region was measured SUV among ascending, transverse and descending colon. Results: The values of patients who took the anti-diabetic drugs including Metformin were $6.16{\pm}3.64$ g/mL, $4.41{\pm}2.94$ g/mL, and $5.46{\pm}2.44$ g/mL. The patients who took the anti-diabetic drugs which does not have Metformin were $3.05{\pm}1.39$ g/mL, $2.08{\pm}0.97$ g/mL and $3.15{\pm}1.85$ g/mL. The control group were $2.02{\pm}0.88$ g/mL, $1.68{\pm}0.87$ g/mL and $2.19{\pm}1.88$ g/mL. Conclusion: The effect of the intake of Metformin was observed from the SUV on region of large bowel in this study. Thus, it could be helpful for the results by identifying the ingredient of anti-diabetic drug before the examination and the possibility of interpretation of false positive will be reduced.

  • PDF

A Case Study of Software Architecture Design by Applying the Quality Attribute-Driven Design Method (품질속성 기반 설계방법을 적용한 소프트웨어 아키텍처 설계 사례연구)

  • Suh, Yong-Suk;Hong, Seok-Boong;Kim, Hyeon-Soo
    • The KIPS Transactions:PartD
    • /
    • v.14D no.1 s.111
    • /
    • pp.121-130
    • /
    • 2007
  • in a software development, the design or architecture prior to implementing the software is essential for the success. This paper presents a case that we successfully designed a software architecture of radiation monitoring system (RMS) for HANARO research reactor currently operating in KAERI by applying the quality attribute-driven design method which is modified from the attribute-driven design (ADD) introduced by Bass[1]. The quality attribute-driven design method consists of following procedures: eliciting functionality and quality requirements of system as architecture drivers, selecting tactics to satisfy the drivers, determining architectures based on the tactics, and implementing and validating the architectures. The availability, maintainability, and interchangeability were elicited as duality requirements, hot-standby dual servers and weak-coupled modulization were selected as tactics, and client-server structure and object-oriented data processing structure were determined at architectures for the RMS. The architecture was implemented using Adroit which is a commercial off-the-shelf software tool and was validated based on performing the function-oriented testing. We found that the design method in this paper is an efficient method for a project which has constraints such as low budget and short period of development time. The architecture will be reused for the development of other RMS in KAERI. Further works are necessary to quantitatively evaluate the architecture.