• Title/Summary/Keyword: 사무소 건축

Search Result 1,321, Processing Time 0.022 seconds

Performance Assessment Model for Fire Safety Protection of Office Building (사무소 건축물의 화재안전 성능 평가모델)

  • Yang, Eun-Bum;Hwang, Young-Sam;Lee, Chan-Sik
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.2
    • /
    • pp.69-74
    • /
    • 2004
  • This study is to suggest a performance assessment model for fire safety protection of office building 34 asessment elements were chosen by interviewing with experts, reviewing several codes and existing relevant models, assessment elements included in this model are comprised of five categories which are 'performace of protected area', 'performance of fire partition', 'safety performance of fire escape', 'performace of smoke control system' and 'performace of fire fighting equipment'. The weight of each element was computed by systematic approach like an AHP (analytical hierarchy process), which was conducted by experts who work in the field of fire protection. This model would be utilized as a part of assessment model for the overall performace of domestic office building.

A Fundamental Study for Calculation of Daylight Responsive Dimming Control Slope in different Height of Roller Shade (Roller Shade 높이 변화에 따른 광센서 조광제어기울기 산정을 위한 기초적 연구)

  • Lim, Ji-Sun;Kim, Yu-Sin;Choi, An-Seop;Lee, Jeong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.257-262
    • /
    • 2008
  • Available daylight in inside offers comfortable view environment, and psychological and physical advantages to people in the room. But, it has a problem of an excessive direct sunlight. This study calculated daylight responsive dimming control slope by Roller Shade system with Mock-up test. With three 1/2 scale Mock-up rooms, we performed a test for calculation of daylight responsive dimming control slope in different shade height of each room through the different height of roller shade systems. This research will be used as a fundamental study for automated roller shade systems.

  • PDF

A Study on the Evaluation Methods of Indoor Thermal Environment in Office Building (사무소건축의 실내온열환경 평가방법에 대한 연구)

  • Choi, Young-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.6 no.4
    • /
    • pp.355-359
    • /
    • 2003
  • 1. The objective of this paper is to investigate the indoor environment from the viewpoint of interaction between physical environment and the human responses. 2. A continuous measurement has been carried out for 1 year and distribution of variables have been measured for 1 day. 3. The attitude of workers was investigated by a questionnaire. 4. As the result, average luminance represented more than 800-1800 lx in the office, in contrast with less than 1000 lx in the encourage luminance of an office. 5. There was a significant difference of the occupants' response to the light environment between the neighboring environments. 6. Measured thermal conditions are on the edge of the ASHRAE comfort envelope in summer, and in the neighborhood of the lower dry limit of the envelope in spring.

  • PDF

An Analysis for Recognizing the priority of Indoor Environmental Factors in office Remodeling (사무소 리모델링의 실내환경요소에 대한 선호도 분석 -수요자와 공급자 측면 비교를 중심으로-)

  • Choi, Jin-Hyuk;Park, Tae-Eun;Lee, Jeong-Bok;Kim, So-Yeon;Lee, Kyung-Hoi
    • KIEAE Journal
    • /
    • v.2 no.4
    • /
    • pp.57-64
    • /
    • 2002
  • Nowadays the importance of Building Remodeling as a means to create an architectural environment capable of responding to the social, economic changes has increased more than before. After long time pass, the aged building have faced the need for the overall repair of the structure and function. Remodeling is much more saving the time and cost than new construction in the office building. This study was focused in functional and efficient evaluation. Based on these points, we developed the evaluation factors, and verified a validity of evaluation factors through a survey. The purpose of this study was focused on the Analysis for Recognizing the priority of Indoor Environmental Factors in office Remodeling. This study provides us the competitive guidance of remodeling. The owners and tenants take the maximum efficiency with the minimum cost.

A Study on Designing a Proper External Shading Device to Diminish the Cooling Load of a Transparent Glazing Office Building (투명 유리 사무소 건물의 냉방부하 감소를 위한 적정 외부차양 배치에 관한연구)

  • Yim, Sang-Joon;Seo, Hye-Soo;Kim, Byung-Seon
    • KIEAE Journal
    • /
    • v.2 no.4
    • /
    • pp.21-26
    • /
    • 2002
  • Modem architecture represent a great capitalistic, polishing, high-technology image to the public by design. As a result, glass architecture which show 'transmittance' in desinging play a leading part, consequently a role of machine is increasing in controlling an internal environment of building. These movement look like assisting an universal standard building disregarding a each nation's climate peculiarity, if glass building is applied by a proper external shading device. the shading device has a great effect on the reduction of cooling load energy, this research to propose the proper designing scheme of the fixed external shading device. The effect of proper external shading device on the cooling load is evaluated by the numeric simulation.

A Study on the Daylight Distribution Analysis in different Height of Roller Shade in a Small Office (Roller Shade 높이 조절에 따른 사무소 건축물의 주광유입분포 분석에 관한 연구)

  • Lim, Ji-Sun;Kim, Yu-Sin;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.17-20
    • /
    • 2008
  • Available daylight in inside offers comfortable view environment, and psychological and physical advantages to people in the room. But, it has a problem of an excessive direct sunlight. This study analyzed daylight distribution characteristic by roller shade systems with a Mock-up test. With three 1/2 Scale Mock-up rooms, we performed a test of daylight distribution performance in different shade height of each room through the different height of roller shade. systems. This research will be used as a fundamental study for automated roller shade systems.

  • PDF

A study of LCA(Life Cycle Assessment) to a office building remodeling - Focused on Electrical Equipment - (사무소건축 리모델링에서의 전과정 평가에 관한 연구 - 전기 부분을 중심으로 -)

  • Lee, Seon-Dong;Yoo, Ho-Chun
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.3
    • /
    • pp.85-92
    • /
    • 2004
  • Environmental issues become one of today's central concerns due to draining natural resources and environmental pollution. Architecture is given a great deal of weight on the evoking environmental pollution. In this point of view, polluting factors in architectural planning and construction were predicted in advance and alternative plans were studied, In investigation of alternative plans, both environmental pollution and economical efficiency of various alternatives were considered. A office building was analyzed for energy consumption and construction environmental load by appling LCA. Applying LCA to a office building includes a total amount of materials and energy consumption, environmental impacts and economical efficiency evaluation. In present study, LCA applied to electrical part of a office building and economical efficiency evaluation was considered.

Analysis and Comparison on the Architectural Lighting of office buildings in Hongkong, Shanghai and Seoul (홍콩, 상해, 서울의 사무소 건축물 경관조명 비교 분석)

  • Jung, Yeon-Hong;Lim, Ji-Sun;Kim, Hyun-Sun;Kim, Yu-Sin;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.24-27
    • /
    • 2009
  • Architectural lighting is an important factor to inform brand image to public for a headquarter building at night The government encourages to clients to apply architectural lighting to their buildings for the nightscape. In these days, variable lightings and lighting designs are applied to a building in the world. Therefore, the purpose of this study is to analyze and compare architectural lighting design on the various office buildings in Hongkong, Shanghai and Seoul with measured luminance and photographic images at night-time.

  • PDF

A Study on the Expression of visual Decoration in External Appearances of High-rise office Architecture (고층 사무소 건축의 외부형태에 나타난 조형적 장식 표현에 관한 연구 -1980년 이후 국내 사례를 중심으로-)

  • Jung, Kwang-Yong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.5 no.4
    • /
    • pp.353-359
    • /
    • 2002
  • The focus of this study is that spacial, material, functional, cubical reasons are visually expressed on high-rise office Architecture in Korea according to the period of their completion. Office buildings are analyzed in three of exterior composition : Lower, Middle, Top part of the Building, Comparing the whole composition of the Building, forty-five types of compositions are extracted ; expression of formal, material, structural, functional Decoration which show the tendencies of Korean office buildings.

  • PDF

Consideration on Maintenance and Utilization of Eoryong-do Lighthouse (어룡도등대 유지 및 활용방안에 대한 고찰)

  • In-Hwan PARK;Hyung-Lae KIM
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2023.11a
    • /
    • pp.157-159
    • /
    • 2023
  • In order to promote the historicity of Eoryongdo Lighthouse, which was designated as a lighthouse cultural heritage in August 2023, and to utilize it as a water-friendly space, the facilities were improved to maintain the function of the lighthouse smoothly, and the buildings were reinforced to utilize it as a water-friendly space. We want to inform the public of the historical value of the lighthouse and make every effort to ensure maritime traffic safety, which is the original role of the lighthouse.

  • PDF