• Title/Summary/Keyword: 빔라인

Search Result 85, Processing Time 0.029 seconds

Acquisition of High Resolution Images and its Application using Synchrotron Radiation Imaging System (방사광 X-선을 이용한 고해상도 영상획득과 응용)

  • 홍순일;김희중;정해조;홍진오;정하규;김동욱;제정호;김보라;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 2001
  • Synchrotron radiation (SR) has several advantages over convetional x-rays, including its phase, collimation, and high flux. A synchrotron radiation beamline 5C1 at Pohang Light Source (PLS) was recently built for imaging applications. We have shown that a SR imaging system is useful in imaging microscopic structures. SR with broad-band energy spectrum were adjusted to an object by Si wafers and their energy were approximately ranging from 6 keV to 30 keV. SR were passed through an object and finally transformed into visible lights by CdWO$_4$ scintillator screen. The visible lights which were reflected at an angle of 90 degrees by gold plated mirror were detected by a CCD camera and the image data were acquired using image acquisition system. A high-resolution phantom, capacitor, adult tooth, child tooth, cancerous breast tissue, and mouse lumbar vertebra were imaged with SR imaging system. The Objects were rotated within the field of view of the CCD detector, and their projection image data were obtained at 250 steps over 180 degrees rotation. Image reconstructions were carried out in a PC by using IDLTM(Research systems, Inc., US) program. The spatial resolution of the images acquired by the SR imaging system was measured with a high-resolution chart manufactured for several micrometer resolution. The specimens were also imaged with conventional x-ray radiography system to compare the image quality of radiography obtained with the SR imaging system. The results showed more structural details and high contrast images with SR imaging system than conventional x-ray radiography system. The SR imaging system may have a potential for imaging in biological researches, material applications, and clinical radiography.

  • PDF

Performance Test of 4Cl Beamline for Protein Solution Scattering at the PLS (용액상의 단백질 구조 분석을 위한 PLS 4Cl빔라인의 성능 테스트)

  • Yu Chung-Jong;Kim Jehan;Kim Kwang-Woo;Kim Ghyung-Hwa;Lee Heung-Soo;Ree Moonhor;Kim Kyung-Jin
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.3
    • /
    • pp.138-142
    • /
    • 2005
  • We tested performance of the 4C1 beamline for analyzing structures of proteins in solution using small angle X-ray scattering (SAXS) at the Pohang Light Source(PLS). Structurally well-known proteins such as lysozyme and $Bcl-XL(\vartriangle TM/\vartriangle loop)$ were used for the study. Low resolution solution structures of lysozyme and $Bcl-XL(\vartriangle TM/\vartriangle loop)$ were obtained at a resolution of at least i.2 nm, and the structures were basically same as those calculated from the crystal structures of the proteins. We also used $Bcl-XL(\vartriangle TM/\vartriangle loop)$ with a long flexible loop attached [$Bcl-XL(\vartriangleTM))$] and obtained significantly different data from $Bcl-XL(\vartriangle TM/\vartriangle loop)$, although the electron density map of the loop is known to be invisible from the crystal structure of $Bcl-XL(\vartriangleTM))$. We confirm that SAXS experiment is a powerful tool for the structural study of proteins in solution and the 4Cl beamline at the PLS is well-equipped and suitable for the protein solution SAXS experiment.

A Study on the Impact of Forklift Institutional, Technical, and Educational Factors on a Disaster Reduction (지게차의 제도적, 기술적, 교육적 요인이 재해감소에 미치는 영향에 관한 연구)

  • Young Min Park;Jin Eog Kim
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.4
    • /
    • pp.770-778
    • /
    • 2023
  • Purpose: In order to reduce forklift industrial accidents, it is necessary to classify them into institutional, technical, and educational factors and conduct research on whether each factor affects disaster reduction. Method: Descriptive statistical analysis, validity analysis, reliability analysis, and multiple regression analysis were conducted using SPSS 18 program based on an offline questionnaire based on a 5-point Likert scale. Result: As a result of multiple regression analysis, it was found that institutional, technical, and educational factors, which are independent variables for disaster reduction, explain about 62.5% of the variance in disaster prevention, which is the dependent variable. The regression model verification was found to be statistically significant with F=118.775 and significance probability p<0.01. Conclusion: First, there is a need to prevent disasters by including electric forklifts weighing less than 3 tons in the inspection system. Second, there is a need to make it mandatory to install front and rear cameras and forklift line beams to prevent forklift collision disasters. Third, there is a need to conduct special training related to forklifts every year, and drivers and nearby workers need to be included in the special training for forklifts.

Direct Patterning Technology of Indium Tin Oxide Layer using Nd:$YVO_4$ Laser Beam (Nd:$YVO_4$ 레이저 빔을 이용한 인듐 주석 산화물 직접 묘화 기술)

  • Kim, Kwang-Ho;Kwon, Sang-Jik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.11
    • /
    • pp.8-12
    • /
    • 2008
  • For the reduction of fabrication cost and process time of AC plasma display panel (PDP), indium tin oxide (ITO) layer was patterned as bus electrode using Nd:$YVO_4$ laser. In comparison with the chemically wet etched ITO patterns, laser ablated ITO patterns showed the formation of shoulders and ripple-like structures at the edge of the ITO lines. For the reduction of shoulders and ripple-like structures, pulse repetition rate and scan velocity of laser was changed. In addition, we analyzed a discharge characteristic of PDP test panel to observe how the shoulders and ripple-like structures influence on the PDP. Based on experimental results, the pattern etched at the 500 mm/s and 40 kHz was better than any other condition. From this experiment we could see the possibility of the laser direct patterning for the application to the patterning of ITO in AC-PDP.

Synchrotron Radiation Imaging of Breast Tissue Using a Phase-contrast Hard X-ray Microscope (경 엑스선 위상차 현미경을 이용한 유방 조직의 방사광 영상)

  • Jeong, Young-Ju;Bong, Jin-Gu;Park, Sung-Hwan
    • Progress in Medical Physics
    • /
    • v.22 no.3
    • /
    • pp.117-123
    • /
    • 2011
  • Synchrotron radiation (SR) imaging enables us to observe internal structures of biologic samples without staining. In this study, we obtained X-ray microscopic images of human breast tissues with 11.1 KeV hard X-ray microscope of the Pohang light source and used zone plates and phase-contrast technique to get high resolution X-ray images. Hard X-ray microscopic images of fibrocystic change and breast cancer tissues with a spatial resolution of 60 nm were obtained and from these images, we could observe the micro-structures of human breast tissue. Also we analyzed and compared these images, which revealed distinct features of each condition. In conclusion, SR imaging with phase-contrast hard X-ray microscope for medical application, especially in breast disease can give some useful information for clinical research.

Optimal Design and Implementation of 3D Shape Restoration System for Femto-second Laser Micromachining (펨토초 레이저 미세가공을 위한 3차원 형상 복원 시스템의 최적설계 및 구현)

  • Park, Jeong-Hong;Lee, Ji-Hong;Ko, Yun-Ho;Park, Young-Woo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.6 s.312
    • /
    • pp.16-26
    • /
    • 2006
  • In this paper, we propose a 3D shape restoration system which measures height and surface shape of transparent ITO glass and delivers errors in focal length and incident angle of laser beam to femto-second laser micromachining. The proposed system is composed of a line scan laser, a high resolution camera, a linear motion guide synchronized to image capturing, and a control station. Also, we define the sensitivity indices that represent a relation between measurement error and a position of a camera and scan laser, and utilize it for optimum design. The results of the proposed system are compared with results of SPM(Scanning Probe Microscope) and prove the usefulness of the system.

User-friendly 3D Object Reconstruction Method based on Structured Light in Ubiquitous Environments (유비쿼터스 환경에서 구조광 기반 사용자 친화적 3차원 객체 재구성 기법)

  • Jung, Sei-Hwa;Lee, Jeongjin
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.11
    • /
    • pp.523-532
    • /
    • 2013
  • Since conventional methods for the reconstruction of 3D objects used a number of cameras or pictures, they required specific hardwares or they were sensitive to the photography environment with a lot of processing time. In this paper, we propose a 3D object reconstruction method using one photograph based on structured light in ubiquitous environments. We use color pattern of the conventional method for structured light. In this paper, we propose a novel pipeline consisting of various image processing techniques for line pattern extraction and matching, which are very important for the performance of the object reconstruction. And we propose the optimal cost function for the pattern matching. Using our method, it is possible to reconstruct a 3D object with efficient computation and easy setting in ubiquitous or mobile environments, for example, a smartphone with a subminiature projector like Galaxy Beam.

Compressibility of $FeS_{2}$ ($FeS_{2}$의 압축성 연구)

  • Kim, Young-Ho;Hwang, Gil-Chan;Cho, Hyen-Goo
    • Journal of the Mineralogical Society of Korea
    • /
    • v.19 no.3 s.49
    • /
    • pp.189-195
    • /
    • 2006
  • Compression work on a pyrite powder has been carried out using energy dispersive X-ray diffraction (EDXRD) with Mao-Bell type diamond anvil cell (DAC) and synchrotron radiation(SR) at room temperature. It has been reported the bulk moduli of pyrite show the large variations depending on the experimental conditions as well as the apparatus used. Thus, two kinds of sample in different pressure transmitting media of both NaCl and MgO powder emerged in alcoholic fluids were subjected to measure their compressibilities. Bulk moduli thus obtained are 138.9 GPa and 198.2 GPa, respectively, and this result contradicts to the anticipated values according to the hydrostaticity conditions of the sample chamber. This might be due to the alcoholic fluids phase transition mainly with the side effects from the difference of both solid state detector (SSD) used and E*d value applied. All experiments were performed at the Beam Line 1B2 of Pohang Light Source (PLS).

외부충전없이 반영구적으로 사용이 가능한 $10mWh/cm^2$급 동위원소기반 전고상(全固相) 하이브리드 전지 원천기술 개발 사업소개

  • Lee, Myeong-Bok;No, Jin-Hui;Yun, Yeong-Mok;Hwang, Cheol-Gyun;Yeo, Seok-Gi;Choe, Gyeong-Sik;Choe, Byeong-Geon;Son, Gwang-Jae;Lee, Jae-Myeong;Yun, Yeong-Su;Lee, Seong-Man;Sin, Dong-Uk;Park, Yong-Jun;Kim, Jong-Dae;Kim, Han-Jun;Kim, U-Jeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.232-233
    • /
    • 2013
  • 본 발표에서 2012년 나노융합산업원천기술개발사업 꼭지로 연구개발을 수행하고 있는 "외부 충전없이 반영구적으로 사용이 가능한 10 mWh/cm2급 동위원소기반 전고상(全固相) 하이브리드 전지 원천기술 개발" 사업의 핵심내용을 간략히 소개하고자 한다. 본 과제의 핵심내용은 국내 유일의 원자로인 하나로의 중성자 빔라인을 이용하여 ${\beta}$-선을 방출하는 동위원소파우더를 생산하고, 방출되는 ${\beta}$-선을 효율적으로 흡수할 수 있는 PN-접합 전지구조에 노출시켜 2차적인 e-h 쌍을 생성시키고, 분리시키고 전극으로 포집하여 전력을 생산하는 한국형 동위원소전지 개발에 있다. 더하여 실시간으로 생성되는 미세한 출력전력을 증폭시켜 저장할 수 있는 고효율 전고상 이차전지와 전력제어회로를 포함하는 한국형 하이브리드전지관련 원천기술 개발관련 세부 사업내용을 소개함으로 관련분야 연구에 대한 국내관심을 환기시켜 관련기술개발을 촉진하고자 한다.

  • PDF

Real-Time XRD Analysis of Polystyrene/Clay Nanocomposites by In-Situ Polymerization (In-situ 중합법에 의한 폴리스티렌/점토 나노복합재료의 실시간 X선 분석)

  • Kim, Jang-Yup;Hwang, Seok-Ho;Hong, Yoo-Seok;Huh, Wan-Soo;Lee, Sang-Won
    • Polymer(Korea)
    • /
    • v.29 no.1
    • /
    • pp.87-90
    • /
    • 2005
  • In this study, we have examined the exfoliation behavior of layered clay during in-situ polymeriztion with styrene by using real-time XRD analysis. The 4C1 beam line at the Pohang Accelerator Laboratory (PAL) was used for this study. Different exfoliation behaviors have been shown to depend on the cation exchange capacity (CEC) of clay and the chemical structure of organic modifiers. For 10A-MMT and 15A-MMT having high CEC, no peak shifts were observed on real-time XRD analysis during polymerization. However, 2$\theta$ for 25A-MMT and VDAC-MMT, each having low CEC’s as well as aromatic benzene moieties and vinyl groups, respectively, decreased as polymerization time increased.