• Title/Summary/Keyword: 비탄성 동적 해석

Search Result 186, Processing Time 0.022 seconds

A Study on Impact Sound Insulation Properties of EPDM Micro Cellular Pad (에틸렌-프로필렌-디엔 삼원 공중합 (EPDM) 발포체의 충격음 저감 특성에 관한 연구)

  • Lee, Kyung-Won;Lee, Jung-Hee;Sohn, Ho-Soung
    • Elastomers and Composites
    • /
    • v.35 no.2
    • /
    • pp.138-148
    • /
    • 2000
  • In order to investigate the possibility of EPDM micro cellular pad (MCP) as an impact sound insulation product, we studied static/dynamic properties and vibration transfer characteristics of EPDM MCP depending on shape, thickness, degrees of foaming by using material test system (MTS) and lab scale mock-up test apparatus. Static/dynamic rigidity is increased when shape is simple. thickness and degrees of foaming low. We could see that dynamic stiffness is proportional to the transmissibility of EPDM MCP. When dynamic stiffness is increased, characteristic peak at transmissibility curve moves high frequency range or snows increase of maximum value of transmissibility. For lab scale mock-up test and finite element method, EPDM MCP shows low vibration velocity and superior mode shape to just concrete plus slab structure. We could confirm that possibility of EPDM MCP as a impact sound insulation product is high.

  • PDF

Dynamic Mechanical Interpretations of Shape Memory Behavior (형상기억 거동의 동적 기계적 해석)

  • 이상엽
    • The Korean Journal of Rheology
    • /
    • v.9 no.1
    • /
    • pp.33-39
    • /
    • 1997
  • PCL, MDI, BD 및 DMPA를 이용, 폴리우레탄(PU)을 ionomer 및 nonionomergudxo 로 제조하였으며 이때 연질성분의 함량(SSC) 및 길이가 PU의 기계적, 동적기계적 특성은 물론 형상기억특성에 미치는 영향을 연구하였다. Ionomer는 nonionomer에 비하여 경도, 탄 성율 및 강도가 모두 우수하였으며 그 효과는 실온에서 경질성분의 함량(HSC)이 높은 PU 일수록 보다 뚜렷하였는데 이는 HSC가 증가할수록 ion 중심의 농도가 증가하며 ion 중심간 의 Coulob 력이 고온보다 실온에서 보다 큰데 기인하는 것으로 해석하였다. 반복인장하중실 험에서 ionomer는 nonionomer에 비해 회복변형이 크고 잔류변형이 작았는데 이는 ionomer 의 고무탄성율이 보다 큰 데 기인한 것으로 해석하였다. 나아가 재료의 형상기억거동은 기 본적으로 탄성율의 온도의존성에 크게 의존함을 알수있었다.

  • PDF

건축물의 내진설계를 위한 구조동력학-제 1부:단자유도 구조물의 지진해석과 응답스펙트럼

  • Lee, Dong-Geun
    • 건축구조
    • /
    • v.13 no.1
    • /
    • pp.46-58
    • /
    • 2006
  • 구조동력학 이론에 기초하여 내진설계 기술이 개발되었다. 그러므로 건축물의 내진설계를 근본적으로 이해하기 위해서는 구조동력학의 여러 가지 이론들을 먼저 알고 이들이 내진설계에 어떻게 적용이 되는지를 알아야 한다. 이 글은 구조기술자 여러분이 건축물의 내진설계를 이해하는데 도움이 될 수 있도록 하기 위하여 다음과 같이 3부로연재될예정이다. 제1부: 응답스펙트럼과구조물의동적해석 제2부: 등가정적해석법과반응수정계수의배경 제3부: 능력스펙트럼법에의한비탄성해석 제1부에서는 단자유도 구조물의 지진해석을 통하여 응답스펙트럼을 작성하는 원리와 이를 이용하여 간편하게 지진해석을 수행하는 방법을 소개하고 응답스펙트럼에 근거하여 설계응답스펙트럼을 작성하는 방법과 다자유도 구조물의 지진응답을 알아내기 위한 응답 스펙트럼 해석법에 관하여 소개한다. 제2부에서는 구조동력학 이론에 근거하여 등가정적해석법이 유도된 근거와 반응수정계수를 사용하게 되는 배경을 소개하여 구조기술자들이내진설계에좀더확실한이해를할수있도록할것이다. 마지막으로 제3부에서는 비탄성해석을 좀 더 쉽게 하기 위하여 사용되는 능력스펙트럼법의 배경과 이를 이용하여 건축물의 성능점을 찾는 방법과 구조물의 비탄성 지진응답을 평가하는 방법에 대하여 소개함으로써 성능에 기초한 내진설계를 위한 기초 이론을 확실히 이해할수있도록할것이다. 구조동력학에 관한 내용을 여기에 상세히 소개하자면 엄청난 분량이 될 것이므로 여기서는 이 글을 읽는 구조기술자들이 구조동력학에 관한 기초적인 내용을 이해하고 있는 것으로 가정하기로 한다. 그러므로 구조동력학에 대한 기초적 이론을 확실히 이해하고 있지 못한분들은이글을읽기전에먼저구조동력학에관한알기쉬운서적을 먼저 읽도록 추천한다.

  • PDF

Dynamic Mechanical Properties of Natural Rubber/Polystyrene IPNs (천연고무/폴리스티렌 IPN의 동적기계적 성질)

  • Do, In-Hwan;Kim, Byeong-Gyu
    • Korean Journal of Materials Research
    • /
    • v.6 no.2
    • /
    • pp.197-203
    • /
    • 1996
  • 천연고무/폴리스티렌계 semi- 및 full-IPN의 동적성질을 IPN 조성과 가교도의 함수로 조사하였고, 23$^{\circ}C$에서의 탄성율을 선택하여 복합모델과 비교하였다. Full-IPN이 semi-IPN에 비해 상분리를 억제시키는 효과가 컸으며, 23$^{\circ}C$에서의 탄성율에서도 Davies 모델에 더 근접하였다. Coran-Patel 모델해석에서, 상전이의 중심이 되는 조성은 full-IPN의 경우 $\Phi$2=0.75-0.8이었다.

  • PDF

Capacity Spectrum Method Based on Inelastic Displacement Ratio (비탄성변위비를 이용한 능력 스펙트럼법)

  • Han, Sang-Whan;Bae, Mun-Su
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.2
    • /
    • pp.69-80
    • /
    • 2008
  • In this study, improved capacity spectrum method (CSM) is proposed. The method can account for higher mode contribution to the seismic response of MDOF systems. The CSM has been conveniently used for determining maximum roof displacement using both demand spectrum and capacity curve of equivalent SDOF system. Unlike the conventional CSM, the maximum roof displacement is determined without iteration using inelastic displacement ratio and R factor calculated from demand spectrum and capacity curve. Three moment resisting steel frames of 3-, 9- and 20-stories are considered to test the accuracy of the proposed method. Nonlinear response history analysis (NL-RHA) for three frames is also conducted, which is considered as an exact solution. SAC LA 10/50 and 2/50 sets of ground motions are used. Moreover, this study estimates maximum story drift ratios (IDR) using ATC-40 CSM and N2-method and compared with those from the proposed method and NL-RHA. It shows that the proposed CSM estimates the maximum IDR accurately better than the previous methods.

The Numerical Modelling and Dynamic Collapse Analysis of the Rectangular Tube (사각관의 수치 모델링 및 동적 붕괴 해석)

  • 강신유;한동철
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.1 no.2
    • /
    • pp.42-48
    • /
    • 1993
  • In this paper, dynamic collapse behavior of the rectangular tube under impact loading is anlayzed using nonlinear finite element method of shell element. In case of shell element formulation using corotational element coordinates system, dynamic collapse behavior is analyzed without initial imperfection, and with initial imperfection. This paper reveals that the collapse of a rectangular tue without initial imperfection is caused by an error of transformation of the corotational coordinates system.

  • PDF

Characteristics of Dynamic Properties of Granite Specimen from Chungnam Yeongi Area (충남 연기군 지역 화강암 시험편의 동적물성 특성에 관한 연구)

  • Min, June-Hyun;Lee, Seung-Joong;Choi, Sung-O.
    • Tunnel and Underground Space
    • /
    • v.21 no.6
    • /
    • pp.480-493
    • /
    • 2011
  • Dynamic rock property is one of most important parameters in design of earthquake-resistant structures. In this study, free-free resonant column test has been conducted to obtain dynamic Young's modulus, dynamic shear modulus, and damping ratio among dynamic properties with granite specimen of Chungnam Yeongi area. The dynamic properties obtained from this test were compared with the physical properties from static rock tests, and their relationship has been analyzed. From our study, it has been concluded that the dynamic Young's modulus and the dynamic shear modulus are linearly proportional to the elastic wave velocity. And also the damping ratio has been identified to be in non-linear inverse proportion to the elastic wave velocity.

A Study on the dynamic properties of substructure in a semi-Conductor Factory (반도체 공장의 격자보 구조에 대한 동특성 해석에 관한 연구)

  • 권형오;박해동;이홍기;김두훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.58-61
    • /
    • 1994
  • 본 연구에서는 내부 외부 진동원(8-30Hz)에 따른 격자보 구조의 동적 응답을 효과적으로 제어하기 위해 격자보 구조의 동적 거동에 지배적인 영향을 미치는 철근비, 질량, 탄성계수 등 여러 인자들의 비교, 분석을 통해 동적 거동에 영향을 미치는 인자를 분석함으로써 격자보 구조의 설계시 인자의 변화에 따른 동적 거동 특성을 예측하여 이에 적절히 대응할 수 있도록 도모하였다. 이를 위해 국내에 건설된 반도체 공장의 격자보 구조 중에서 기본 해석 모델을 결정하고 이에 대해 실험적 모드 해석과 유한 요소 해석을 사용해서 기본 해석 모델의 모드 매개변수를 구하고, 기본 해석 모델에 사용되는 각 인자가 고유 진동수에 미치는 영향을 비교.분석하였다.

  • PDF

A Study of Seismic Resistant Design for Base-Isolated Bridges(I) (지진에 대비한 기초분리 교량의 설계법에 관한 연구(I))

  • Lee, Sang Soo
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.4 s.33
    • /
    • pp.625-635
    • /
    • 1997
  • The base isolation technique and its benefits in reducing the transmitted earthquake energy into a structure have gained increasing recognition during the last two decades. Unfortunately, the current available design procedures, especially for base-isolated bridges, seem inadequate and too restrictive. As a result, practical design procedure still relies upon a series of deterministic time history analyses. In this study, the evaluation of the possibility of the normal mode method to predict the nonlinear seismic responses of base isolated bridges has been performed. The applicability has been examined through the numerical approach with isolator's elastic or plastic states of the base isolated bridges. Numerical results show that the 1st. mode period and the various responses are varied with the state but are conversed. And, the result show that the normal mode method is applicable to predict the seismic responses and to design the babe isolated bridge. Various analysis method to bridges with bilinearized hysteresis isolator and various pier heights are evalulated.

  • PDF

Dynamic Analysis of Very Large Floating Structure Using Beams on Elastic Foundation (탄성지지된 보를 이용한 초대형 부유구조물의 동적해석)

  • Hong, Sang-Hyun;Im, Yu-Bin;Kim, Jung-Myung;Lee, Jong-Seh
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.723-726
    • /
    • 2011
  • 전 세계적으로 사회기반시설 및 신재생 에너지 생산을 위한 공간부족 문제를 해결하기 위하여 초대형 부유구조물에 대한 관심이 증가하고 있다. 다양한 사용분야에 대한 안정성 확보를 위해 파랑하중에 의한 동적 응답과 부유체의 강성 대비 길이 효과로 인해 발생할 수 있는 특이 거동에 대한 분석이 필요하다. 초대형 부유구조물의 경우 중앙부에 비해 양끝 단에서 과도한 응답이 발생하며, 이를 해결하기 위해 입사파가 들어오는 초대형 부유구조물의 단부에 부착되는 다양한 감요장치(anti-motion device)가 제안되어지고 있다. 초대형 부유구조물에 감요장치가 적용될 경우 입사파에 의한 동적 파압을 감소시켜 구조물의 전반적인 응답을 줄여줄 수는 있지만 감요장치의 질량이 클 경우 오히려 끝단의 응답을 증폭시킬 수 있다. 본 논문에서는 양단 자유 경계조건의 탄성지지된 보를 이용하여 초대형 부유구조물의 길이와 끝단에 부착된 감요장치의 질량으로 인한 영향을 분석하였다.

  • PDF