• Title/Summary/Keyword: 비접촉식 센서

Search Result 165, Processing Time 0.025 seconds

Development of Mirror-based touchless fingerprint sensor (거울을 이용한 비접촉식 지문 센서 개발)

  • Choi, Hee-Seung;Choi, Kyung-Taek;Kim, Jai-Hie
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.231-232
    • /
    • 2007
  • This paper introduce a new touchless fingerprint sensor. Two mirrors are used to capture the side fingerprint images which cannot detectable using a single camera. We also propose the techniques which can solve the image contrast, nonuniform illumination, DOF(Depth of Field) problems. This new sensor leads to bringing new challenges in the field of fingerprint recognition.

  • PDF

Fingerprint Image Sequence Mosaicking in Touchless Fingerprint Sensor (비접촉식 지문센서에서의 지문 영상 시퀀스 융합)

  • Choi, Kyoung-Taek;Choi, Hee-Seung;Kim, Jai-Hie
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.377-378
    • /
    • 2007
  • This paper proposes an system to generate rolled-equivalent fingerprints by mosaicking sequential images captured by an toothless device. To capture rolled-equivalent fingerprints, previous works use multiple cameras. However, the method in this paper captures sequential fingerprint images with a single camera and mosaic the images by estimating the transform between images through optical flow.

  • PDF

Development of Automated Non-contact Thickness Measurement Machine using a Laser Sensor (레이저센서를 이용한 비접촉식 두께자동측정기 개발)

  • Cho, Kyung-Chul;Kim, Soo-Youn;Shin, Ki-Yeol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.2
    • /
    • pp.51-58
    • /
    • 2015
  • In this study, we developed an automated non-contact thickness measurement machine that continuously and precisely measures the thickness and warp of a PCB product using a laser sensor. The system contains a measurement part to measure the thickness in real time automatically according to the set conditions with an alignment supply unit and unloading unit to separate OK and NG products. The measurement machine was utilized to evaluate the performance at each step to minimize measurement error. At the zero setting for the initial setup, the standard deviation of the 216 samples was determined to be $5.52{\mu}m$. A measurement error of 0.5mm and 1.0mm as a standard sample in the measurement accuracy assessment was found to be 2.48% and 2.28%, respectively. In the factory acceptance test, the standard deviation of 1.461mm PCB was measured as $28.99{\mu}m$, with a $C_{pk}$ of 1.2. The automatic thickness measurement machine developed in this study can contribute to productivity and quality improvement in the mass production process.

Gesture recognition with wearable device based on deep learning (딥러닝 기반의 웨어러블 디바이스에서의 제스처 인식)

  • Byeon, Seong-U;Lee, Seok-Pil;Kim, Geon-Nyeon;Han, Sang-Hyeon
    • Broadcasting and Media Magazine
    • /
    • v.22 no.1
    • /
    • pp.10-18
    • /
    • 2017
  • 본 연구는 비접촉식 센서 기반의 웨어러블 디바이스를 이용한 딥러닝 기반의 제스처 인식에 대한 연구이다. 이를 위하여 Flexible MSG 센서를 기반으로 한 Flexible Epidermal Tactile Sensor를 사용하였으며, Flexible Epidermal Tactile Sensor는 손, 손가락 제스처를 취했을 때 손목, 손가락과 연결되어 있는 근육들의 움직임에 따라 발생하는 피부 표면의 전극을 취득하는 센서이다. 실험을 위하여 7가지 손, 손가락 제스처를 정의하였으며, 손목의 꺾임, 손목의 뒤틀림, 손가락의 오므림과 펴짐, 아무 동작도 취하지 않은 기본 상태에 대한 제스처로 정의하였다. 실험 데이터 수집에는 손목이나 손가락에 부상, 장애등이 없는 일반적인 8명의 참가자가 참가하였으며 각각 한 제스처에 대하여 20번씩 반복하여 1120개의 샘플을 수집하였다. 입력신호에 대한 제스처를 학습하기 위해 본 논문에서는 1차원 Convolutional Neural Network를 제안하였으며, 성능 비교를 위해 신호의 크기를 반영하는 특징벡터인 Integral Absolute Value와 Difference Absolute Mean Value를 입력신호에서 추출하고 Support Vector Machine을 사용하여 본 논문에서 제안한 1차원 CNN과 성능비교를 하였다. 그 결과 본 논문에서 제안한 1차원 CNN의 분류 정확도가 우수한 성능을 나타냈다.

Noncontact displacement sensors using magnetic scale (자기스케일을 이용한 비접촉식 변위센서)

  • Lee, Sung-Pil;Seo, Young-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.197-201
    • /
    • 2009
  • This paper studies on the noncontact displacement sensor system to detect the displacement of the cylinder rod. For an inexpensive and a simple process, magnetic scales are printed on the cylinder rod, and magnetized by the specially designed magnetizer that has an yoke through the alternation of N and S pole. Noncontact displacement sensor system consists of cylinder with magnetic scales, Hall sensor, linear guide, controller and display. The system can detect the displacement of moving cylinder with 5 cm/sec in the case of 1 mm magnetic scale. It shows a possibility of position detection of hydraulic cylinder and air cylinder.

A Study on the Seam Tracking by Using Image Processing (영상정보처리에 의한 용접선 추적에 관한 연구)

  • 배철오;박영산;이성근;김윤식;안병원;김현수
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.460-464
    • /
    • 2001
  • Recently, the use of Robot increase little by little for the purpose of developing a welding quality and productivity in the arc welding part. It is more important to contact the seam for arc welding before moving a welding robot. There are two types of method to contact the seam namely contact and noncontact type largely In this paper, image processing sensor(a kind of non-contact sensor) is concerned to track the seam by using laser diode and CCD camera. A structured laser diode's light illuminated on the weld groove and the reflected shape is introduced by CCD camera. The image board captures this image and software analyzes this image. The robot is moved and welded exactly as acquired image X-Y data is changed with robot's X-Y value. Also, most of seam tracking are considered by changing the program simply in case of the different weld prove of plane surface.

  • PDF

Radiant Energy Filtering to Enhance High Temperature Measurement by a Thermography System (고온 계측 열화상 시스템 구현을 위한 복사에너지 필터링 연구)

  • Yoon, Seok Tae;Cho, Yong Jin;Jung, Ho Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.6
    • /
    • pp.466-473
    • /
    • 2016
  • In a shipbuilding process, thermal damage to the ship structure at the rear end results from an excessive heat input and conduction during welding process. To prevent such damage, appropriate control of the heat input, based on welding temperature measurement, is required. For temperature measurement, contact and non-contact methods are available; the thermography system is a popular non-contact temperature measurement. When the intensity of radiation from a high-temperature object is excessive, however, detecting the sensors of ordinary thermography systems leads to an inability in measuring the temperature due to saturation. Hence, this study suggests use of a neutral density filter that prevents an excessive amount of radiation from being accumulated in a thermography system, and thus makes it possible to quantitatively measure an object's temperature as high as $3000^{\circ}C$.

Design of partial discharge sensor in rotating machines (저.고주파용 부분방전 센서 해석 및 설계)

  • Park, Yoon-Mi;Heo, Chang-Geun;Lee, Jung-Yub;Jung, Hyun-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2253-2255
    • /
    • 2005
  • 운전 중인 회전기기에서 고정자 권선의 절연 상태는 부분방전시험을 통해 검사, 평가할 수 있고 이를 통하여 사고예방을 위한 진단을 할 수 있다. 기존 센서인 SSC(Stator Slot Coupler)는 비접촉식으로 권선의 웨지 아래에 설치하므로 설치하기가 불편하고 Global VPI 방식으로 제작된 소형 회전기에는 사용할 수 없는 단점이 있다. 본 논문에서는 소형 회전기에 사용 가능한 저, 고주파용 부분방전 센서를 제안하였다. 웨지 위에 설치 가능한 SSC 형태의 마이크로스트립 센서 및 2선 평행 전송선로 센서는 고주파에 적합하고 저렴하며 소형 회전 기에 설치 가능하다. 센서의 성능을 검증하기 위해 3차원 해석 프로그램을 사용하여 좋은 전자파 검출 성능을 도출할 수 있었다. 또한 저주파용으로 제안된 U 타입 센서는 유도전류를 검출하는 센서로서 슬롯 외부에 설치되어야 하고 시간차분 수치해석을 이용해서 저주파에서 효과적으로 방전 펄스를 검출함을 확인할 수 있었다.

  • PDF

Development of an Optical Sensor for Measuring the Shape of a Back Light Unit Module (백라이트 모듈 유리의 형상 측정을 위한 광센서 개발)

  • Jang Yong-jin;Ryu Young-kee;Oh Chun-suk
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.06a
    • /
    • pp.176-178
    • /
    • 2004
  • 디스플레이 매체의 발전에 따라 TV나 컴퓨터 모니터 또는 TFT-LCD, PDP, EL 등의 평판 디스플레이장치들의 대형화, 고화질, 고정밀도가 요구되어지고 있다. 이러한 디스플레이 장치들은 영상표시를 위해 유리를 사용하고 있는데, 사용되는 유리의 형상과 두께는 디스플레이 장치들의 성능에 영향을 준다. 특히 장치가 대형화되면서 대형 평판 유리의 변형된 형상과 균일하지 않은 두께는 디스플레이 장치들의 고화질, 고정밀도를 막는 주요한 요인이 되고 있다. 이러한 이유로 디스플레이 장치용 평판 유리의 형상 및 두께를 측정하는 센서의 요구가 많아지고 있다. 그러나 아직 유리의 형상과 두께를 측정하는 센서 및 시스템은 고가이고. 측정 방법 또한 많은 문제점을 가지고 있다. 본 논문에서는 이러한 문제점들을 해결하기 위하여 하나의 센서로 유리의 형상과 두께를 동시에 고속으로 측정이 가능한 저가의 비접촉식 광센서를 개발하기로 한다. 이 논문에서 개발된 광센서에는 CD-player에 사용되는 홀로그램 레이저를 사용함으로써 고정밀 형상측정, 저가의 광센서, 센서의 소형화를 이룰 수 있다.

  • PDF

A Study on Wearable Emotion Monitoring System Under Natural Conditions Applying Noncontact Type Inductive Sensor (자연 상태에서의 인간감성 평가를 위한 비접촉식 인덕티브 센싱 기반의 착용형 센서 연구)

  • Hyun-Seung Cho;Jin-Hee Yang;Sang-Yeob Lee;Jeong-Whan Lee;Joo-Hyeon Lee;Hoon Kim
    • Science of Emotion and Sensibility
    • /
    • v.26 no.3
    • /
    • pp.149-160
    • /
    • 2023
  • This study develops a time-varying system-based noncontact fabric sensor that can measure cerebral blood-flow signals to explore the possibility of brain blood-signal detection and emotional evaluation. The textile sensor was implemented as a coil-type sensor by combining 30 silver threads of 40 deniers and then embroidering it with the computer machine. For the cerebral blood-flow measurement experiment, subjects were asked to attach a coil-type sensor to the carotid artery area, wear an electrocardiogram (ECG) electrode and a respiration (RSP) measurement belt. In addition, Doppler ultrasonography was performed using an ultrasonic diagnostic device to measure the speed of blood flow. The subject was asked to wear Meta Quest 2, measure the blood-flow change signal when viewing the manipulated image visual stimulus, and fill out an emotional-evaluation questionnaire. The measurement results show that the textile-sensor-measured signal also changes with a change in the blood-flow rate signal measured using the Doppler ultrasonography. These findings verify that the cerebral blood-flow signal can be measured using a coil-type textile sensor. In addition, the HRV extracted from ECG and PLL signals (textile sensor signals) are calculated and compared for emotional evaluation. The comparison results show that for the change in the ratio because of the activation of the sympathetic and parasympathetic nervous systems due to visual stimulation, the values calculated using the textile sensor and ECG signals tend to be similar. In conclusion, a the proposed time-varying system-based coil-type textile sensor can be used to study changes in the cerebral blood flow and monitor emotions.