• Title/Summary/Keyword: 비선형 감쇠

Search Result 317, Processing Time 0.024 seconds

Roll Damping Moment of a Small Fishing Vessel by Free Rolling Test in Waves (파랑중 자유 횡동요 시험에 의한 소형어선의 횡동요 감쇠모멘트에 관한 연구)

  • H.H. Chun;S.H. Chun;S.Y. Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.37 no.2
    • /
    • pp.30-37
    • /
    • 2000
  • The roll damping characteristics of the three models of a 3ton class fishing vessel, that is the bare hull, hull with bilge keels, and hull with bilge keels and a central wing are investigated by the free roll tests in head waves in a towing tank with the variations of the forward speed, initial angle and OG. The wave length variations are also included. The experimental results are compared with the numerical results of mathematical modellings by the energy method for these three models and the energy dissipation patterns are also compared. The roll damping speed increases, the effect of the waves on the roll damping of the models with the additional devices is negligible due to the much increased damping caused by the lift increase.

  • PDF

Mitigating Seismic Response of the RC Framed Apartment Building Structures Using Stair-Installation Kagome Damping System (계단 설치형 카고메 감쇠시스템을 활용한 철근콘크리트 라멘조 공동주택의 지진응답 개선)

  • Hur, Moo-Won;Chun, Young-Soo;Lee, Sang-Hyun;Hwang, Jae-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.5
    • /
    • pp.23-30
    • /
    • 2018
  • Recently, there are highly interests on structural damping to improve resistance of seismic and wind. It has been frequently used hysteresis damping devices made of steel because of economic efficiency, construction, and maintenance. This paper presents the effective reduction of seismic response by using Kagome damping system(SKDS) in rahmen system apartment building. The proposed system is designed to be activated by the relative displacement between the building and the stairs. It is performed nonlinear dynamic analysis to review the effects of earthquake response reduction for the 20-stories rahmen framed apartment building. In the analysis of the SKDS system, the reduction of maximum response displacement, maximum response acceleration and layer shear force are compared with the seismic design, and the result show that allowable story displacement is satisfied with Korean Building Code (KBC 2016).

Development of a Combined Model for Soil Damping Behavior (지반의 감쇠 거동를 위한 복합 모델 개발)

  • Bae, Yoon-Shin
    • International Journal of Highway Engineering
    • /
    • v.10 no.2
    • /
    • pp.27-33
    • /
    • 2008
  • Damping behavior of various soil models are compared to actual observed soil damping behavior. Several nonlinear soil models were used and evaluated to predict damping behavior of soils. A combined damping model incorporating both nonvisous and hysteretic damping behavior was developed to better approximate soil behavior. The strengths and limitations of this model are discussed.

  • PDF

Study on the Application of Damping Ratio in the Seismic Performance Evaluation of Concrete Dams (콘크리트 댐 내진성능평가 시 감쇠비 적용 방안 고찰)

  • Jeong-Keun Oh;Yeong-Seok Jeong;Minho Kwon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.1
    • /
    • pp.9-18
    • /
    • 2023
  • The purpose of this paper is to review the appropriateness of the application method for the value of the damping ratio suggested in the current design standards and evaluation guidelines when evaluating the seismic performance of concrete dams and to suggest improvements. As a result of the study, for the magnitude of the damping ratio in the dynamic elastic analysis, it is necessary to refer to the case of a similar dam in which the magnitude of the earthquake load is similar and the reproducibility of the damping ratio has been verified. Considering this, it is necessary to apply a low damping ratio and consider adding hysteresis damping in case of nonlinear behavior. In addition, since the concrete dam body located on the rock has insignificant radiation attenuation effect, it is not reasonable to increase the damping ratio of the concrete dam body to reflect the radiation damping. Therefore, in order to evaluate the realistic seismic performance of concrete dams, it is necessary to revise the damping ratio-related contents contained in the current dam design standards and evaluation guidelines.

Fuzzy $H^{\infty}$ Controller Design for Uncertain Nonlinear Systems (불확실성을 갖는 비선형 시스템의 퍼지 $H^{\infty}$ 제어기 설계)

  • Lee, Kap-Rai;Jeung, Eun-Tae;Park, Hong-Bae
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.6
    • /
    • pp.46-54
    • /
    • 1998
  • This paper presents a method for designing robust fuzzy $H^{\infty}$ controllers which stabilize nonlinear systems with parameter uncertainty adn guarantee an induced $L_{2}$ norm bound constraint on disturbance attenuation for all admissible uncertainties. Takagi and Sugeno's fuzzy models with uncertainty are used as the model for the uncertain nonlinear systems. Fuzzy control systems utilize the concept of so-called parallel distributed compensation(PDC). Using a single quadratic Lyapunov function, the stability condition satisfying decay rate and disturbance attenuation condition for Takagi and Sugeno's fuzzy model with parameter uncertainty are discussed. A sufficient condition for the existence of robust fuzzy $H^{\infty}$ controllers is then presented in terms of linear matrix inequalities(LMIs). Finally, design examples of robust fuzzy $H^{\infty}$ controllers for uncertain nonlinear systems are presented.

  • PDF

Capacity Spectrum Analysis using Equivalent SDOF Method and Equivalent Damping Method for RC Wall Structure (철근콘크리트 벽체구조물에 대한 등가단자유도 방법 및 등가 감쇠비 산정방법에 따른 역량스펙트럼해석)

  • Song, Jong-Keol;Jang, Dong-Hui;Kim, Hark-Soo;Chung, Yeong-Hwa
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.2
    • /
    • pp.169-187
    • /
    • 2008
  • Performance-based approaches as an alternative method of the existing force-based approach have gradually become recognized tools for the seismic design and evaluation. The maximum inelastic displacement response using capacity spectrum method (CSM) with elastic response spectrum is estimated from seismic response of equivalent linear system converted from nonlinear system. The purpose of this paper is to evaluate accuracy of capacity spectrum method using the equivalent SDOF methods of 4 types and the equivalent damping methods of 5 types for RC wall structure. In order to evaluate accuracy of capacity spectrum analysis, the shaking table test results for RC wall structures are compared with those by the capacity spectrum analysis. Also, the effect of bilinear capacity curves by two bilinear approximation methods for capacity spectrum analysis is compared.

고감쇠 면진베어링을 이용한 지진응답 감소

  • Koo, Gyeong-Hoe;Lee, Jae-Han;Yoo, Bong
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05b
    • /
    • pp.987-992
    • /
    • 1995
  • 본 논문에서는 복잡한 Hysteretic 복원력-변형률 특성을 갖는 고감쇠 면진베어링에 대한 Hysteretic bi-linear 모델을 사용하여 비교적 해의 정확성을 보장할 수 있는 Runge-Kutta 방법으로 지진해석을 위한 공식을 유도하였다. 그리고 Hysteretic bi-linear 모델을 사용한 면진베어링의 응답해석결과로부터 등가선형모델을 구하여 각각의 모델에 대한 지진응답 특성들을 비교분석하였다. 고감쇠 면진베어링을 전형적인 경수로원자로모델에 적용한 결과 면진구조물은 비면진 구조물에 비하여 가속도응답이 크게 감소함을 알 수가 있었다. 또한 면진베어링의 Hysteretic bi-linear 모델을 사용한 지진응답해석은 등가선형모델에 비하여 최대 변위응답특성은 유사하나 가속도응답은 크게 나타났다.

  • PDF

Effects of Orifice Length on Helmholtz Resonator (음향공 오리피스 길이 변화에 따른 감쇠 효과)

  • Song, Jae-Gang;Ko, Young-Sung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.36-39
    • /
    • 2008
  • Combustion instability is one of the most difficult problems in the development of liquid rocket engines. One of the damping devices for combustion instability is helmholtz resonator. Orifice length is one of factors for designing it. In this study, effects of orifice length are investigated by an experimental tests and a linear acoustic analysis. Damping capacity was improved by the increase of the length of resonator. And the results of an experimental tests and a linear acoustic analysis are showed similar tendency. Also, effects of supplied SPL(sound pressure level) are investigated and the results show that nonlinear effects are increase by the increase of supplied SPL.

  • PDF

Effect of Aerodynamic Nonlinearity on Drive-Train of Wind Turbine (공기역학적 비선형성이 풍력발전기 드라이버-트레인에 미치는 영향)

  • Lim, Chae-Wook
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.05a
    • /
    • pp.235-235
    • /
    • 2010
  • 풍력발전기의 공기역학적 비선형성은 풍력발전기 전체 시스템의 동적특성에 영향을 미친다. 풍력발전기의 드라이버-트레인의 감쇠가 매우 작으므로 풍력발전기를 제어함에 있어 드라이버-트레인의 동적특성은 중요하게 고려되어야 한다. 본 논문에서는 풍속에 따른 공기역학적 비선형성이 드라이버-트레인의 동적특성에 미치는 영향을 해석적으로 살펴보고자 한다.

  • PDF

Inelastic Displacement Ratio for Strength-limited Bilinear SDF Systems (강도한계 이선형 단자유도 시스템의 비탄성 변위비)

  • Han, Sang-Whan;Lee, Tae-Sub;Seok, Seung-Wook
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.23-28
    • /
    • 2010
  • This study evaluated the effect of vibration, level of lateral yielding strength, site conditions, ductility factor, strain-hardening ratio, and post-capping ratio of the strength limited bilinear SDF systems on the inelastic displacement ratio. The nonlinear response history analysis was conducted using 240 ground motions which were collected at the sites classified as site classes B, C, and D according to the NEHRP. To account for the P-$\Delta$ effects, this study considered negative stiffness ratios ranging from -0.1 to -0.5 of elastic stiffness. Four different damping ratios are used: 2, 5, 10, and 20%. From this study, an equation of inelastic displacement ratio was proposed using nonlinear regression analysis.