DOI QR코드

DOI QR Code

Mitigating Seismic Response of the RC Framed Apartment Building Structures Using Stair-Installation Kagome Damping System

계단 설치형 카고메 감쇠시스템을 활용한 철근콘크리트 라멘조 공동주택의 지진응답 개선

  • Received : 2018.04.07
  • Accepted : 2018.07.06
  • Published : 2018.09.01

Abstract

Recently, there are highly interests on structural damping to improve resistance of seismic and wind. It has been frequently used hysteresis damping devices made of steel because of economic efficiency, construction, and maintenance. This paper presents the effective reduction of seismic response by using Kagome damping system(SKDS) in rahmen system apartment building. The proposed system is designed to be activated by the relative displacement between the building and the stairs. It is performed nonlinear dynamic analysis to review the effects of earthquake response reduction for the 20-stories rahmen framed apartment building. In the analysis of the SKDS system, the reduction of maximum response displacement, maximum response acceleration and layer shear force are compared with the seismic design, and the result show that allowable story displacement is satisfied with Korean Building Code (KBC 2016).

최근 들어 건물의 내진 및 내풍 성능을 향상시키기 위하여 감쇠구조에 대한 관심이 높아지고 있다. 감쇠장치 중 저렴한 비용과 높은 에너지소산능력을 발휘하며, 설치와 유지관리가 용이하다는 장점이 있어 강재이력형 감쇠장치를 이용한 수동형 감쇠구조시스템이 널리 사용되고 있다. 본 논문에서는 라멘구조 또는 무량판 구조에 적합한 계단 설치형 카고메 감쇠시스템(SKDS)을 제안하고자 하며, 제안된 감쇠시스템의 지진응답 개선효과에 대하여 해석적으로 검토하고자 한다. 비선형 동적해석결과 최대응답변위, 최대응답가속도 및 밑면전단력 감소로 살펴볼 때 내진구조와 비교하여 더 향상된 거동이 기대된다는 점에서 SKDS의 효과를 확인할 수 있었다.

Keywords

References

  1. Kim, Y. J., Park, J. H., Hwang, J. H., Ahn, T. S., (2017), Mitigating Seismic Response of the RC Framed Apartment Building Structures Using Exterior-Installation Kagome Damping System, Proceedings of Architectural Institute of Korea, 37(1). 733-734.
  2. Roh, J. E., Lee, S. H., (2016), Experimental Evaluation of a Multi-action Hybrid Damper under Cyclic Loading, Journal of the Architectural Institute of Korea Structures & Construction, 32(11), 3-9.
  3. Hur, M. W., Chun, Y. S., Lee, S. H., (2016) Inelastic Seismic Response Control of the RC Framed Apartment Building Structures Using Exterior-Installed Kagome Damping System, Journal of Korea institute for Structural Maintenance Inspection, 20(3), 58-65. https://doi.org/10.11112/jksmi.2016.20.3.058
  4. Roh, J. E., Hur, M. W., Woo, S. S., Lee, S. H., Choi, H. H., Lee, K. H., (2016), Application of a Multi-action Hybrid Damper for Enhancing the Structural Performance of Building Structures Subject to Wind Loads, Journal of The Wind Engineering Institute of Korea, 20(3), 1-7.
  5. Korean Building and Commentary (2016), Architectural Institute of Korea.
  6. AIK, (2016), Guidelines for Performance-Based Seismic Design of Residential Buildings, Architectural Institute of Korea.
  7. Hur, M. W., Lee, S. H., Chun, Y. S., (2015), Vibration Control Effect of the Framed Building Structures according to the Stiffness Ratio of Exo-type Damping System and Damper Device Yield Ratio, Journal of Korea institute for Structural Maintenance Inspection, 19(5), 38-44. https://doi.org/10.11112/jksmi.2015.19.5.038
  8. Hur, M. W., Lee, S. H., Chun, Y. S., (2015), Vibration Control of the Framed Building Structures Using KGDS System with Isotropic Damping Devices, Journal of Korea institute for Structural Maintenance Inspection, 19(2), 52-59. https://doi.org/10.11112/jksmi.2015.19.2.052
  9. Hwang, J. S., Park, S. C., Kang, K. J., (2013), A Study on the Hysteresis properties and Mathematical Model of Kagome Truss Damper, Architectural Institute of Korea, 29(9), 21-29.
  10. Oh, S. H., (2012), Optimal vibration control Design Methodology of Apartments, LH technology seminar.
  11. Lee, H. H., Kim, S. I., (2012), Hysteretic Behaviors of Metallic Dampers with the Various Slit Shape, Journal of Korea institute for Structural Maintenance Inspection, 16(2), 206-207.
  12. Lee, H. H., Kim, S. I., (2010), Metallic Damper Shape and Cyclic Behavior for the Seismic Capacity Improvement of Building Structures, Journal of Korea institute for Structural Maintenance Inspection, 14(3), 123-130. https://doi.org/10.11112/jksmi.2010.14.3.123
  13. ASCE, (2010), ASCE/SEI 7-10 Minimum Design Loads for Buildings and Other Structures, American Society. of Civil Engineers, 179-197.
  14. Oh, S. H., Kim, Y. J., Ryu, H, S., Choi, H. B., Kang, C. H., (2005), Hystersis Behavior of Beam-to-Column Connections with Elasto-Plastic Hysteretic Dampers, Architectural Institute of Korea, 25(1), 635-638.
  15. Applied Technology Council, (2005), Improvement of Static Seismic Analysis Procedures, FEMA 440 Report.
  16. Federal Emergency Management Agency, (2000), Prestandard and Commentary for the Seismic Rehabilitation of Buildings, FEMA 356 Report.