• Title/Summary/Keyword: 분리상태

Search Result 1,555, Processing Time 0.034 seconds

A Study of Seismic Resistant Design for Base-Isolated Bridges(I) (지진에 대비한 기초분리 교량의 설계법에 관한 연구(I))

  • Lee, Sang Soo
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.4 s.33
    • /
    • pp.625-635
    • /
    • 1997
  • The base isolation technique and its benefits in reducing the transmitted earthquake energy into a structure have gained increasing recognition during the last two decades. Unfortunately, the current available design procedures, especially for base-isolated bridges, seem inadequate and too restrictive. As a result, practical design procedure still relies upon a series of deterministic time history analyses. In this study, the evaluation of the possibility of the normal mode method to predict the nonlinear seismic responses of base isolated bridges has been performed. The applicability has been examined through the numerical approach with isolator's elastic or plastic states of the base isolated bridges. Numerical results show that the 1st. mode period and the various responses are varied with the state but are conversed. And, the result show that the normal mode method is applicable to predict the seismic responses and to design the babe isolated bridge. Various analysis method to bridges with bilinearized hysteresis isolator and various pier heights are evalulated.

  • PDF

Analysis of Personality and Emotion State Model Based on Multiple-Valued Automata (다치오토마타를 이용한 개성 및 감성상태 모델의 해석)

  • 손창식;정환묵
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2003.09b
    • /
    • pp.173-176
    • /
    • 2003
  • 본 논문은 기존의 다치오토마타 모델을 적용하여 개성과 감성상태 모델을 제안한다. 기존 다치오토마타 모델을 2개의 오토마타로 분리하여 하나는 감성상태, 다른 하나는 개성을 모델링하는데 이용하였다. 사용자의 내부 감성과 개성은 Valence-Arousal 공간으로 정의된 감성상태를 바탕으로 구성하였고, 2개로 분리된 다치오토마타의 관계를 정의에 따라 구성하여 감성상태와 개성이 동시에 한 개의 오토마타 모델로 모델링 될 수 있는 가능성을 제시하였다.

  • PDF

막결합형 혐기성 소화에서 동력학적 인자의 영향

  • 추광호;이정학
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.04a
    • /
    • pp.62-63
    • /
    • 1995
  • 혐기성 소화는 고농도의 유기폐수를 최종적으로 메탄으로 전환하여 에너지원을 회수할 수 있는 효율적인 생물학적 폐수처리 공정 중의 하나이다. 그런데 이러한 혐기성 소화 공정에서 가장 큰 장애요인으로 작용하고 있는 요소 중의 하나가 매생물의 침강성 저하로 인한 고액분리의 문제이다. 이로인해 현재 고전적인 중력침강법, 부상법 대신에 분리막을 이용한 막결합형 혐기성 소화 공정이 대두되고 있으며 완전한 고액분리, 반응조내의 고농도 미생물 보유, 양질의 최종 유출수 획득 등 많은 장점들이 제시되고 있다. 그러나 이러한 장점에도 불구하고 시간에 따른 막오염 현상, 분리막 표면에서의 케이크층 형성 등으로 인한 막투과 유속 (flux)의 감소는 분리막의 응용에 있어 경제성을 저하시키는 주요한 부정적 요인으로 지적되고 있다. 그리고 막분리 성능은 분리막의 특성, 유체역학적 조건, 그리고 혐기성 소화 상태 등에 의해 영향을 받을 수 있다. 본 연구에서는 막결합형 혐기성 소화 공정의 십자흐름 (crossflow) 막분리 공정에서 유체역학적 조건 및 혐기성 소화조의 상태와 관련된 요인들이 어떻게 막투과도 및 배제율 등에 영향을 미치는 지 살펴보고자 한다.

  • PDF

A Study on Islanding Detection of Distributed Generation Considering Fault Location (사고위치를 고려한 분산전원의 단독운전 상태 검출에 관한 연구)

  • 정승복;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.118-123
    • /
    • 2004
  • This paper studies islanding detection of DG(distributed generation) considering fault location. Through the past studies, we found that islanding detection has been studied that DG disconnected when power islanding was detected by power state change and output change of DG. But, fault location was not considered. For example, fault in adjacent distribution line, fault on interconnection line fault, load shave by overload and normal operation were not considered. In this paper, We distinguish these considerations through power state change. Also, we proved islanding detection algorithm through PSCAD/EMTDC simulation.

An Experimental Study on the Structural Bechavior of Two-layered Reinforced Concrete Slabs in Bridges (교량에서 2층 분리타설한 철근콘크리트 슬래브의 구조거동에 관한 실험연구)

  • 오병환;이형준;이명규;한승환
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.3
    • /
    • pp.162-172
    • /
    • 1994
  • The flexural and horizontal shear behavior of overlaid concrete slabs with polymer interface is investigated in the present study. An experimental program was set up and several series of overlaid concrete slabs have been tested to study the effect of different surface preparations and dowel bars between old slab and overlay under service and ultimate loads. 'The cracking and ulti mate load behavior for various cases including acryl emulsion treatment and doweled joints has been studied. The present study indica.tes that the overlaid concrete slabs behave integrally with existing bottom slabs up to ultimate range for rough and doweled joints with polymer interface. The pres ent study provides a firm base for the realistic design of two-layered RC slabs in bridges.

Analysis and the Conservation Treatment of the Paper Relics of the Seonwon Temple Area (선원사지(禪源寺地)출토 지류 유물의 분석 및 보존 처리 방법)

  • Lim, Ju-Hee;Park, Chi-sun
    • Journal of Conservation Science
    • /
    • v.12 no.1 s.15
    • /
    • pp.71-82
    • /
    • 2003
  • The paper relics excavated from the 4th excavation of the historical spot No.259 Seonwon temple area were analyzed and conserved. Because these works remained folded, the most important conservation treatment was a separation. This process depended on the state of the works: dry state works were separated using Gore-Tex chamber and the filtrated water, wet state works were separated through vacuum freeze drying method. Analyses of the paper relics performed were examination on the paper to find its distinction, binocular microscope and SEM on fiber, and XRF on character ingredient. This study presumed the times though $C^{14}$ dating of these works. The works were able to be classified through analysis and conservation treatment. This separation made lost part of the works conserve an archetype. This study presented the application of conservation methods on the paper relics which are in the bad condition and obtained information through carbon dating of it.

  • PDF

Development of an algorithm for the separation of ECG from mixed EMG signal (ICA를 이용한 근전도에 첨가된 심전도 신호 분리 알고리즘의 개발)

  • Lee, J.;Kwon, O.Y.;Lee, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2687-2689
    • /
    • 2002
  • 본 연구는 환자의 근육 상태를 표면 근전도(EMG, Electrocardiogram)를 통해 정량적으로 평가한 결과를 기반으로 적응 전기치료를 수행 시, 근전도 정량평가에 영향을 주는 심전도 신호를 독립요소 해석(ICA, Independent Component Analysis)을 이용하여 획득된 신호로부터 분리함으로써, 정확한 근전도 정량평가를 할 수 있도록 하는 것을 목적으로 한다. 실험 방법은 소스(source)를 근전도와 심전도 2개로 가정하고, 4 채널을 통하여 획득된 신호를 10 Hz-500 Hz의 대역통과 필터를 이용하여 필터링한 후, 1000 sample/sec로 샘플링하여 센서로 사용하였으며, JADE(Joint Approximate Diagonalization of Eigen-matrices) 알고리즘을 통하여 근전도 신호와 심전도 신호를 분리하였다. 알고리즘의 permutation ambiguity와 scaling ambiguity 특성 문제를 해결하기 위하여, 분리된 신호의 주파수 분석을 통하여 심전도와 근전도 신호로 구분하였으며, 인식된 근전도 신호의 크기를 센서 신호를 기준으로 복원하였다. 결론적으로 아날로그 및 디지털 필터와 달리 근전도의 신호의 왜곡을 극소화하면서도 심전도 신호를 분리해 냄으로써, 근전도를 통한 근육상태의 효과적인 평가가 가능하게 되었다.

  • PDF

Initial Equilibrium Configuration Analysis for Bridges Supported with Stayed and Suspended Cables (사장-현수 복합케이블 교량에 대한 초기평형상태 해석)

  • Kim, Kyu-Hwan;Kim, Ho-Kyung;Lee, Hae-Sung
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.76-77
    • /
    • 2011
  • 본 논문에서는 새로운 케이블 교량 형식인 사장-현수 복합케이블 교량 형식에 대한 초기평형상태 해석방법을 제시한다. 구체적으로 복합케이블 교량의 해석방법으로 다음과 같은 두 가지 방법을 제안한다. 우선 사장교의 초기평형상태 해석에서 사용된 전체 구조물을 하나의 구조물로 생각하여 해석하는 일괄방식 해석방법을 제안한다. 이 방법을 적용하는 과정에서 행어부문의 거동이 기존의 가정에 위배되는 문제점이 발견되었는데, 이러한 문제점은 변위복원방식의 successive iteration 을 적용하여 해결하였다. 다음으로 현수교의 초기평형상태 해석에서 사용된 전체 구조물을 현수교 부문과 사장교 부문 그리고 행어 부문의 3가지 부문으로 분리하여 해석하는 분리방식 해석방법을 제안한다. 이 방법을 적용하는 과정에서는 위의 일괄방식 해석방법에서 나타난 행어의 거동이 기존의 가정에 위배되는 현상과 더불어, 분리된 각 부문의 평형 조건과 적합조건이 일치하지 않는다는 문제점이 발생하였다. 이러한 추가의 문제점은 타워 최상단부의 수평변위를 적절히 구속시키고 각 부문 해석의 초기값을 조절하여 해결하였다. 마지막으로 제안된 두 가지 방법을 Deck에 캠버가 있는 적절한 예제를 통해서 검증하였다.

  • PDF

Fast voltage sag detection method applicable for three-phase unbalanced grid (3상 불평형 계통에 적용가능한 빠른 새그 검출방법)

  • Jo, HyunSik;Kim, Youngrok;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.127-128
    • /
    • 2012
  • 본 논문에서는 전압 불평형, 단상 전압 새그, 3상 정전 등의 비정상적인 계통에 대해서 적용 가능한 동기좌표 기반의 3상 새그 검출 방법을 제안하고 그 가능성을 비교하였다. 3상 새그 보상기는 계통 정상상태에서는 부하에 전력을 공급하고, 계통 새그나 사고 발생 시 이상상태를 검출하여 싸이리스터를 오프하여 계통과 부하를 분리하고 부하에 안정하고 연속적으로 정격 전압을 공급한다. 새그 보상기의 중요한 조건 중 하나는 얼마나 빨리 계통의 이상상태를 검출하여 중요부하와 계통을 분리시켜주는 것이다. 본 논문에서는 계통 불평형 상태에서 동기좌표계에서 발생하는 2고조파 성분을 빠르게 상쇄시키는 구조적으로 간단한 계통의 이상상태를 검출하는 방법을 제안하였다. 제안한 새그 검출기법의 타당성을 시뮬레이션을 통하여 검증 하였다.

  • PDF