• Title/Summary/Keyword: 분류식 하수처리

Search Result 17, Processing Time 0.024 seconds

Effects of Combined Sewer Overflows According to Drainage Basin Types (유역형상에 따른 합류식 하수도의 월류부하량 추정)

  • Lee, Cheol-Kyu;Hyun, In-Hwan;Jeong, Jeong-Youl;Shim, Jae-Hyun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.4 s.15
    • /
    • pp.21-26
    • /
    • 2004
  • It is muck important to determine the intercepting capacities as measures for reducing the load of contamination influenced by CSOs during wet weather period. Intercepting and treating the whole rainfalls can be best measured for reducing the contamination load, but it is not desirable in view of scale and preservation of the wastewater treatment facilities. This study analyzed the quantity and quality of the water in the combined sewer by method of changing the type and size of drainage basin and intercepting capacities in rainfalls, estimate the influence the other CSOs at the change of planned intercepted quantity, and compared the degree of contamination load between the combined system and separate system by examining the influence of the other CSOs at the change of planned intercepted quantity.

Isolation and Culture Conditions of Hydrogen-producing Bacterium from Sewage Sludge (하수슬러지에서 수소생산 균주의 분리 및 배양조건)

  • Woo, Dae-Sik;Joo, Hyun;Lee, Jae-Hwa
    • Applied Chemistry for Engineering
    • /
    • v.24 no.4
    • /
    • pp.407-411
    • /
    • 2013
  • Hydrogen producing bacterium, strain AS12 was isolated from the sludge of the anaerobic wastewater treatment process of south sewage treatment plant, Busan city. Phylogenetic analysis based on 16S rRNA sequence studies indicated that AS12 belonged to the genus Escherichia coli sp.. The optimum temperature and pH for hydrogen production were $35^{\circ}C$ and 8.0, respectively. The impact of the types and concentrations of carbon and nitrogen sources in the media on hydrogen production was investigated. The optimum carbon and nitrogen concentrations were 10 g/L of galactose and 5 g/L of peptone, respectively.

A Study on Process Optimization for CSOs Application of Horizontal Flow Filtration Technology (수평흐름식 여과기술의 CSOs 적용을 위한 공정 최적화 연구)

  • Kim, Jae-Hak;Yang, Jeong-Ha;Lee, Young-Shin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.56-63
    • /
    • 2018
  • The management of Combined Sewer Overflows(CSOs) and Separated Sewer Overflows(SSOs) discharge directly to the effluent system in an untreated state, which occurs when the facility capacity is exceeded due to heavy rain, has become an important issue in recent years as the heavy rain becomes a regular phenomenon. Despite the continuous development of filtration technology, targeting densely populated urban areas, CSOs are rarely applied. Therefore, this study was carried out to optimize the process to apply CSOs in a pilot-scale horizontal flow filtration system with a rope-type synthetic fiber. The research was carried out in two steps: a preliminary study using artificial samples and a field study using sewage. In the preliminary study using an artificial sample, head loss of the filter media itself was analyzed to be approximately 1.1cm, and the head loss was increased by approximately 0.1cm as the linear velocity was increased by 10m/hr. In addition, the SS removal efficiency was stable at 81.4%, the filtration duration was maintained for more than 6 hours, and the average recovery rate of 98% was obtained by air backwashing only. In the on-site evaluation using sewage, the filtration duration was approximately 2 hours and the average removal efficiency of 83.9% was obtained when belt screen (over 450 mesh) was applied as a pre-treatment process to prevent the premature clogging of filter media. To apply the filtration process to CSOs and SSOs, it was concluded that the combination with the pre-treatment process was important to reinforce the hydraulic dimension for the stable maintain of operation period, rather than efficiency. Compared to the dry season, the quality of incoming sewage was lower in the rainy season, which was attributed to the characteristics of the drainage area with higher sanitary sewerage. In addition, the difference in removal efficiency according to the influent quality of the wet season and dry season was small.

Change in Influent Concentration of Domestic Wastewater from Separated Sewer and Biological Nitrogen and Phosphorus Removal of a Full Scale Air-vent SBR (분류식 하수관거로의 전환시 유입하수의 성상 변화 및 선회와류식 SBR공법의 처리 특성)

  • Lee, Jang-Hee;Kang, Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.1
    • /
    • pp.63-70
    • /
    • 2012
  • This study was carried out to investigate change in influent concentration of domestic wastewater flowed from a newly constructed separate sewer system (SSS) and biological nutrients removal efficiency of a full scale Air-vent sequential batch reactor (SBR, $600m^3/d$). The average concentration of $BOD_5$, SS, T-N and T-P from SSS were 246.5 mg/L, 231.6 mg/L, 42.974 mg/L, 5.360 mg/L, respectively which corresponds to 2.2times, 1.2times, 1.8times and 2.1times higher than those from the conventional combined sewer system (CSS). The removal efficiency of $BOD_5$, SS, T-N, and T-P for the Air-vent SBR operated with influent from SSS averaged 99.1%, 99.0%, 91.2%, and 93.5%, respectively. Especially the respective nitrogen and phosphorus removal was 15% greater than that of the SBR operated with influent from CSS. Simultaneous nitrification and denitrification (SND) was observed in an aerobic reactor(II) as a result of DO concentration gradient developed along the depth by the Air-vent system. In order to achieve T-N removal greater than 90%, the C/N ratio should be over 6.0 and the difference between $BOD_5$ loading and nitrogen loading rate be over 100 kg/day (0.130 kg $T-N/m^3{\cdot}d$). Even with high influent T-P concentration of 5.360 mg/L from SSS (compared with 2.465 mg/L from CSS) T-P removal achieved 93.5% which was 15.5% higher than that of the SBR with influent from CSS. This is probably due to high influent $BOD_5$ concentration from SSS that could provide soluble carbon source to release phosphorus at anaerobic condition. In order to achieve T-P removal greater than 90%, the difference between $BOD_5$ loading and phosphorus loading rate should be over 100 kg /day (0.130 kg $T-N/m^3{\cdot}d$).

A Study on the Effects of Cosubstrates on the Biological Treatment and the Decolorization Mechanisms of Dyeing Wastewater (염색폐수의 생물학적 처리에 미치는 cosubstrates의 영향 및 색도제거 기전 연구)

  • Kim, Mee-Kyung;Seo, Sang-Jun;Ahn, Jae-Hwan;Shin, Eung-Bai
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.7
    • /
    • pp.738-745
    • /
    • 2006
  • In this research, the decolorization mechanisms of dye wastewater were divided into two pathways, one was physicochemical sorption to biomass flocs and the other was biological removal by microbial metabolisms. Batch tests were conducted to examine the reaction conditions, anaerobic and aerobic conditions, types and dose of cosubstrates, and to confirm the mechanisms of decolorization through the biosorption tests using the activated sludge and the autoclaved deactivated sludge. From the tests, the decolorization efficiencies of dye wastewater were 102 ${\Delta}$unit/g MLSS under the aerobic condition and 123 ${\Delta}$unit/g MLSS under the anaerobic condition, and organic removals were 82 $mg{\Delta}$COD/gMLSS and 75 $mg{\Delta}$COD/gMLSS respectively. Acetate was the more efficient cosubstrate than the domestic wastewater in the decolorization step. In addition the removal of colors and organics was increased with cosubstrates dosage. And $20.3{\sim}37.3$ ${\Delta}$unit/g MLSS was removed by the autoclaved sludge and $102.0{\sim}159.0$ ${\Delta}$unit/g MLSS by the activated sludge. The physicochemical sorption was dominant in the beginning of biosorption tests, and the biological decolorization was increased with a cosubstrate in the course of time.

A Study on the Water Reuse Systems (중수도개발연구(中水道開發研究))

  • Park, Chung Hyun;Lee, Seong Key;Chung, Jae Chul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.4
    • /
    • pp.113-125
    • /
    • 1984
  • Water supply has been mainly dependent on the construction of the dams in Korea. It is difficult, however, to continue to construct dams for many reasons, such as the decrease of construction sites, the increase of construction costs, the compensation of residents in flooded areas, and the environmental effects. Water demands have increased and are expected to continue increasing due to the concentration of people in the cities, the rise of the living standard, and rapid industrial growth. It is acutely important to find countermeasures such as development of ground water, desalination, and recycling of waste water to cope with increasing water demands. Recycling waste water includes all means of supplying non-potable water for their respective usages with proper water quality which is not the same quality as potable water. The usages of the recycled water include toilet flushing, air conditioning, car washing, yard watering, road cleaning, park sprinkling, and fire fighting, etc. Raw water for recycling is obtained from drainage water from buildings, toilets, and cooling towers, treated waste water, polluted rivers, ground water, reinfall, etc. The water quantity must be considered as well as its quality in selecting raw water for the recycling. The types of recycling may be classified roughly into closed recycle systems and open recycle systems, which can be further subdivided into individual recycle systems, regional recycle systems and large scale recycle system. The treatment methods of wastewater combine biochemical and physiochemical methods. The former includes activated sludge treatment, bio-disc treatment, and contact aeration treatment, and the latter contains sedimentation, sand filtration, activated carbon adsorption, ozone treatment, chlorination, and membrane filter. The recycling patterns in other countries were investigated and the effects of the recycling were divided into direct and indirect effects. The problems of water reuse in recycle patterns were also studied. The problems include technological, sanitary, and operational problems as well as cost and legislative ones. The duties of installation and administrative organization, structural standards for reuse of water, maintenance and financial disposal were also studied.

  • PDF

Evaluation and Improvement Measures on the Status of the Installation and Operation of Facilities for Recycling Food Waste into Resources (음식물 자원화시설의 설치·운영에 대한 일반현황의 평가 및 개선 방안)

  • Ryu, Ji-Young;Kong, Kyu-Sik;Shin, Dae-Yewn;Phae, Chae-Gun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.3
    • /
    • pp.63-75
    • /
    • 2004
  • This research sought to determine the status of the installation and operation of domestic public resource-making facilities of resource-making facilities and come up with corresponding improvement measures. Currently compost is most numerous set-up out of facilties already established ever since, then the rest of them are feeds, anaerobic degradation, sewage combination, and combination of compost and feeds in order. As such, food waste is processed more into compost than into feeds, presumably because relevant facilities, which were originally designed for processing into feeds, were converted into composting facilities due to little demand for the processed feeds. The finding says that many related firms had yet to register their businesses in accordance with feeds and fertilizers management laws, and that food waste resources-making facilities used various basic facilities but few of them treated food waste in linkage with leaching water, bad odors, and energy. Some of current facilities were found to be 7 years old and thus outdated. Due to lack of skilled operational manpower, many facilities had less than 300 days of normal operation yearly, and some needed minor and serious repairs periodically. In overall facilities, 87% of the planned food waste was rolled in, thus requiring measures to treat the whole planned volume. For costs of resource-making facilities, some with a capacity of below 50 tons topped 100 million won, and facilities with a capacity of over 50 tons required less installation costs. Overall, installation costs ranged from 10 million to 20 million, and to 200 million won per ton, and this suggests a need to establish the installation cost calculation criteria, as well as to reshape the facility criteria. With operating costs varying greatly according to the size and treatment methods of facilities, the finding indicates a need to rationalize the operating costs, and to plan appropriate-size installation and operation of facilities to ensure economic operation.

  • PDF