• Title/Summary/Keyword: 부식현상

Search Result 371, Processing Time 0.026 seconds

Corrosion Monitoring of Reinforcing Bars in Cement Mortar Exposed to Seawater Immersion-and-dry Cycles (해수침지-건조 환경에 노출된 모르타르속 철근의 부식속도 평가)

  • Kim, Je-kyoung;Kee, Seong-Hoon;Yee, Jurng-Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.4
    • /
    • pp.10-18
    • /
    • 2018
  • The primary purposes of this study are to understand a fundamental aspect of current uniformity around a reinforcing bar (rebar) in cement mortar, and to develop an accurate monitoring method in a wet-dry cycling process with the alternative current (AC) impedance method. Three cement mortar specimens with two embedded rebars were prepared in the laboratory. As a main variable, the distance between two rebars was designed to be 10, 20 and 30 mm with the same thickness of 20 mm. To simulate the corrosion of rebars in concrete structures in a marine environment, three cement mortar specimens were exposed to 15 wet-drying cycles (24-hour-immersion in seawater and 48-hour-drying in a room temperature) in the laboratory. It was observed that the potential level shifted to a noble value during corrosion potential monitoring, which is attributed to acceleration of dissolved oxygen diffusion at the drying process. AC impedance was measured in a frequency range from 100 kHz to 1 mHz on a wet-drying process. A theoretical model was proposed to explain the interface condition between the rebars and cement mortar by using the equivalent circuit consisting of a solution resistance, a charge transfer resistance and a CPE (constant phase element). It was observed that the diffusion impedance appeared in a low frequency range as corrosion of rebars progresses. At the drying stage of the wet-drying cycles, the currents line for monitoring tended to be non-uniform at the interface of rebar/mortar, being phase shift, ${\theta}$, close to $-45^{\circ}$.

Applicability for Authenticity of Bronze Artefacts using Scientific Analyses (과학적 분석을 통한 전세품 청동기의 진위판별 적용 가능성 연구)

  • Do, Misol;Chung, Kwang Yong
    • Journal of Conservation Science
    • /
    • v.29 no.4
    • /
    • pp.355-366
    • /
    • 2013
  • Diverse scientific analyses, including microstructure, ICP-AES, SEM-EDS, and P-XRF(Bench Top type and Gun type), were carried out on 6 bronze artefacts which handed from generation to generation. Also, we attempted to study applicability for authenticity of the bronze artefacts using scientific analyses based on the specific element. The results of ICP-AES analysis showed that the bronze were formed from an alloy of Cu, Sn, Pb with trace elements such as Ag, As, Co, Fe, but there were not Zn found. The result of P-XRF are 10~25% lower in Cu and 10~20% higher in Sn than that of ICP-AES. This is because of destannification that the compound of $SnO_2$ are present on the surface. The results of SEM-EDS represented that there is lead segregation. It was difficult to study applicability for authenticity of bronze artefact according to the microstructures and chemical components of the bronze artefacts. Therefore, as bronze artefacts have shown different corrosion materials depending on the buried environment and conserving environment, identifying the authenticity would be possible on the basis of the additional researches on the corrosion and comparative research of ancient art.

Optical(Interferometric) Measurements of Vapor Deposition Growth Rate and Dew Points in Combustion Gases (빛의 간섭현상을 이용한 증기용착 성장속도 측정법의 실험적 연구)

  • 김상수;송영훈
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.3
    • /
    • pp.343-348
    • /
    • 1986
  • An optical interference method was developed for measuring rapidly growing and evaporating liquid condensate films (e.g., Na$_{2}$SO$_{4}$, $K_{2}$SO$_{4}$) on solid surface exposed to flowing combustion product gases at film thicknesses well below the onset of complications due to run-off. To develop this optical system, this study investigated the optical parameters (e.g., polarization state, incident angle, target roughness, etc.) Trends for the Na$_{2}$SO$_{4}$(l) and $K_{2}$SO$_{4}$(l) deposition rates as a function of target temperature using this optical measuring system agree with the theoretical prediction of the vapor deposition. This study was able to extend the experimental range for vapor plus condensed phase transport and deposition. While previously unable to measure the evaporation rates interferometrically, these rates are estimated from the results of the investigation of polarization states.

Studies on Preventive Methods Against Concrete Corrosion by Sea Water (ll) (조수에 의한 콘크리트 침식방지법에 관한 연구(ll))

  • 고재군
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.15 no.2
    • /
    • pp.3018-3030
    • /
    • 1973
  • This study was carried out to investigate the effects of various mix designs of concrete on the compressive strengths and corrosive rates when the concretes were immersed in sea water of the West Sea, as the part of study related to durated to durability of concrete by action of the sea water. Concrete mix designs used in this study were ordinary Concrete mix, Concrete mixes with different admixtures such as fly ash, pozzolith and vinsol resin, and pozzolan concrete mix. The concrete specimens were made and cured for 7 days and 28 days in the fresh water in accordance with the Korean Standard specification for concrete. Compressive strengths of the specimens were measured after immersing the specimens for one year in fresh water and sea water which were placed indoors. The sea water used in this test was taken from the Bay of Ahsan. Corrosive rate was also tested after immersing the specimens in the same sea water and placed indoors for one year. The results obtained from the tests are summarized as follows; 1. Compressive strength of an ordinary concrete was the lowest of the various mix desings of concrete immersed both in the fresh water and the sea water. Therefore, the uses of pozzolan cement, fly ash, pozoolith and vinsol resin in mix design of concrete had and effect on increasing compressive strength. 2. Pozzolan concrete was the most effective on compressive strength in the fresh water, but it had less effect than concrete with fly ash admixture immersed in the sea water. 3. The use of fly ash admixture in mix design of concrete showed higher strength as the immersing age is longer both in fresh water and sea water than the other concretes besides pozzolan concrete, but the concretewith fly ash admixture had lower strength than pozzolan concrete in the sea water. Therefore, concrete with fly ash admixture might be better than the pozzolan concrete as far as durability of concrete to sea water was concerned. 4. The use of pozzolith admixture in mix design of concrete had less compressive strength than the use of pozzolan cement for fly ash admixture both in fresh water and sea water. However, the concrete with pozzolith admixture was much stronger than one with vinsol resin admixture in fresh water, but somewhat stronger in the sea water. 5. Though the use of vinsol resin admixture was more effective than ordinary concrete on compressive strength both in fresh water and sea water, it was the least compressive strength among the other concretes. 6. Relation between compressive strengths and absorption rates of every kind of concrete besides concrete with fly ash admixture showed a linear regression line and the compressive strength is highee as the absorption rate is lower. Concrete with fly ash admixture had extremely high strength in comparison with corresponding adsorption rates of the other concretes. 7. Corrosive appearance on the surface of concretes was not occured significantly when exposed to the sea water for one year, However, the specimens of concretes besides ordinary concrete were a little heavier than those cured in fresh water for 28 days.

  • PDF

A Study on Fouling Phenomena of in Petroleum Chemical Process (석유화학공정내에서 원유의 파울링 현상에 관한 연구)

  • Lee, Dong Rak;Ryu, Sang Ryoun;Park, Sang Jin;Cho, Wook Sang;Kim, Sang Wook
    • Applied Chemistry for Engineering
    • /
    • v.7 no.3
    • /
    • pp.443-452
    • /
    • 1996
  • Fouling is caused by sedimentation and corrosion of polymer, heavy paraffine, chemicals, heavy organics, asphaltene, etc. in the entire chemical process of heat exchanger, boiler, desalter, etc. Fouling phenomena remains a serious operating problem which results in increased energy consumption, increased pressure drops, reduction or complete loss of products yield, and increased maintenance costs. In order to calculate the separated amounts of foulants and to control the fouling process, the predictive model is developed which is based on Scott & Magat polymer solution theory, Peng-Robinson EOS, BWR EOS, and continuous and multicomponent thermodynamics.

  • PDF

Conservation of stapled books: Rebinding using colored iron cores (철제 스테이플이 박힌 책의 보존처리)

  • Ha, Hyojin;Choi, Jungeun
    • Journal of Conservation Science
    • /
    • v.30 no.1
    • /
    • pp.27-32
    • /
    • 2014
  • The sample book was printed in 1935. Since the books in the early twentieth century were printed using acidic paper, the color of the paper would change to brown over time due to iron corrosion. In addition to corroding iron cores, the acidity of the paper (pH 3.2) also made the paper brown and fragile, as was true in the case of the sample book. To clean the paper of the sample book and to make it strong, we replaced the iron core and performed wet cleaning on the paper to remove contaminants. Then we pressed the sample book dry, and subsequently linening every page with Minoshi($4g/m^2$). Generally, book conservator rebinding the book using wires or threads: however we have devised a new method to rebind the book using colored iron cores. To color the iron core brown, they were dipped in an aqueous coloring solution ($H_2O$, $C_2H_5OH$, $CuSO_4{\cdot}5H_2O$, $FeCl_3{\cdot}6H_2O$); subsequently, a 20% paraloid B-72 was applied to protect the colored iron cores from corrosion.

A Study on the Corrosion Behavior of Fe-Ni-Cr Alloys in Molten Salts of LiCl and LiCl-${Li_2}O$ (LiCl 및 LiCl-${Li_2}O$ 용융염에서 Fe-Ni-Cr 합금의 부식거동 연구)

  • Jo, Su-Haeng;Jang, Jun-Seon;Hong, Sun-Seon;Sin, Yeong-Jun;Park, Hyeon-Su
    • Korean Journal of Materials Research
    • /
    • v.10 no.7
    • /
    • pp.471-477
    • /
    • 2000
  • Corrosion behavior of Fe-Ni-Cr alloy in molten salts of LiCl and LiCl-$Li_2O was investigated in the tempera-ture range of $650~850^{\circ}C$. In the molten salt of LiCl, and internal oxidation of Fe occurred in the KSA(Kaeri Superalloy)-1 alloy without containing Cr, while a dense protective oxide scale of $LiCrO_2$ was formed in the KSA-4, Incoloy 800H and KSA-5 alloys. In the mixed molten salt of LiCl-$Li_2O$, internal oxidation of Fe and Cr took place in the KSA-1 and KSA-4 alloys, respectively. Non-protective porous oxide scales consisting of $LiCrO_2$ and Ni were formed in the Incoloy 800H and KSA-5. The corrosion rate of the alloys increased with the increase in Cr content and the corrosion rate followed the parabolic law for the alloy containing Cr content less than 8%, and the linear law for the alloy containing Cr content more than 8%. Such a corrosion behavior of the alloy in the mixed molten salt of LiCl-$Li_2O$ was interpreted in terms of the basic fluxing mechanism of protective oxide scale of $Cr_2O_3$.

  • PDF

Study of the $SO_2$ combustion gases occurring from a livestock waste biogas power system (축산바이오가스발전시스템 가동 시 발생되는 연소 배기가스 중 $SO_2$에 관한 연구)

  • Choi, Jaejoon;Jung, Daehun;Park, Byungsik;Park, Jinsung;Huh, Changsu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.173.2-173.2
    • /
    • 2011
  • 대체 에너지 자원 중 폐기물의 소화 가스를 이용한 바이오가스 발전은 이산화탄소에 비해 온실효과 영향력에 21배에 해당하는 메탄가스를 연료로 사용하여 환경부하를 저감시키고 에너지를 생산한다. 바이오가스에 포함된 $H_2S$는 연소 후 $SO_2$형태로 발생되는데 $SO_2$는 수분과 반응을 하게 되면 $H_2SO_4$등의 강한 산성을 띄는 물질로 생성되어 배관 및 발전기에 손상을 주고 저온부식현상을 유발하게 하며, 동물이나 인체에 노출되면 기관지 수축현상이 일어나 호흡기에 영향을 주는 질식성을 띄는 가스이다. 축산바이오가스에 포함된 $H_2S$의 함유량과 가스엔진의 연소 시 배출되는 $SO_2$ 배기가스 성분의 관련성을 검증하기 위해 60-65%의 $CH_4$와 30-35%의 $CO_2$ 성분의 바이오가스를 50kW급 발전기에서 사용하였고 연소 후 배출되는 가스 성분을 분석하였다.

  • PDF

Phase Separation in $Nd_2$$O_3$-${Al_2}{O_3}-{SiO_2}-{TiO_2}$Glass ($Nd_2$$O_3$-${Al_2}{O_3}-{SiO_2}-{TiO_2}$유리계의 상분리현상)

  • 최우형;김형순
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.12
    • /
    • pp.1221-1228
    • /
    • 2000
  • TiO$_2$를 포함한 희토류 알루미노 규산염계 (NAS: Nd$_2$O$_3$-Al$_2$O$_3$-SiO$_2$) 유리의 상분리 현상에 대하여 연구되었다. 0~10wt%의 TiO$_2$포함한 NAS 조성은 유리전이온도(T$_{g}$) 부근에서 열처리하여 HF로 부식 후 주사전자현미경, 라만 및 IR 분석기로 상분리가 조사되었다. 그 결과로 상분리한 내부결정화는 8wt% 이상의 TiO$_2$를 포함한 NAS 조성에서 나타났다. 어닐링후 T$_{g}$ 부근에서 열처리의 결과는 투명 연핑크색의 유리를 불투명의 연푸른 우유빛 색으로 변하게 하였으며, Si와 Nd-Ti가 각각 풍부한 10$mu extrm{m}$ 이상과 0.1$\mu\textrm{m}$ 이하의 크기인 구형상의 영역으로 균일한 다상분리를 일으켰다. Nd$_2$O$_3$-Al$_2$O$_3$-SiO$_2$-TiO$_2$계에서 상분리는 내부 결정화와 관련하여 매우 중요한 인자로 확인되었다.

  • PDF

Corrosion Reduction Techniques of Pipe Line Net Using DVGW (DVGW이론에 따른 상수관망의 부식방지에 관한 연구)

  • Choo, Tai-Ho;Kim, Ha-Il;Je, Sung-Jin;Ok, Chi-Youl
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.11
    • /
    • pp.310-316
    • /
    • 2006
  • Leakage of waterworks pipe line net cause loss of water resources, additional foundation of pressurization facilities from pressure loss and soil weakening near leaked pipe line, etc.. This makes it difficult to maintain and manage waterworks pipe line net and so cause serious economic loss. The rate of accounted water can be improved by monitoring always water pressure and flux, and so on. from isolated region, preparing positively against leakage accident and preventing leakage from occurring. Actually after isolating region, average rate of accounted water in this region went up 88.94% by continuously monitoring control of water pressure and inflow rate. It is about 9.44% higher than that of Busan metropolitan city in 2003, 79.5%.

  • PDF