• 제목/요약/키워드: 부식조

검색결과 153건 처리시간 0.024초

철근보강 지오폴리머 콘크리트 시험체에 전기화학적 방식기법 적용과 방식성능 분석 (Electro Chemical Protection Property for Reinforced Geo-Polymer Specimen Under Ocean Environment and Accelerated Test)

  • 박동천;조규환
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.178-179
    • /
    • 2014
  • Corrosion is very serious problem in RC structure under ocean environment. There is no enough experiment information using the reinforced geo polymer concrete applied by electo chemical protection system. Three condition, such as tidal zone, submerged zone and crack were simulated to geo polymer specimen. Corrosion rate and natural electrode potential were measured through accelerated test. Anti corrosion property of geo polymer was better than OPC regardless of specimen condition and applied time.

  • PDF

철근콘크리트조 아파트구조물의 노후도 실태조사에 의한 노후화 요인 분석.평가에 관한 연구 (A Study on the Analysis and Evaluation of Deterioration Factors for the Structure of Reinforced Concrete Apartment According to Actual Condition Survey)

  • 강석표;김규용;권영진;정성철;이덕찬;송병창;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회 논문집(I)
    • /
    • pp.391-396
    • /
    • 1998
  • The concrete structures are hardly ever built under ideal conditions. So many defects may occur for a various reasons such as unsuitable and defective materials, construction methods, poor workmanship, particular structural form and prevailing weather conditions. Some structural form can greatly increase the risk of occurrence of defects. Therefore we investigated the actual condition of the deterioration factors for reinforced concrete apartment, which was composed of 85 apartments with various building ages in different regions with five evaluation the deterioration factors of apartment building to establish the overall evaluation system of deterioration degree for reinforced concrete apartment in Korea.

  • PDF

브레이크 디스크의 산질화처리가 부식지연 및 제동특성에 미치는 영향에 관한 연구 (A Study of Effects of Ferritic Nitrocarburized Brake Disc on Its Corrosion Resistance and Braking Performances)

  • 한진;김광윤;이학인;이정주
    • 자동차안전학회지
    • /
    • 제7권2호
    • /
    • pp.19-24
    • /
    • 2015
  • Ferritic Nitro Carburizing (FNC) cast iron brake discs is known to improve corrosion resistance and brake creep groan noise as well as prevent corrosion-induced pulsation. But, it is necessary to treat honing machining on braking surface to avoid grinding noise during braking.

스테인레스강 Overlay용접부의 수소취화 균열감수성에 관한 연구 1 (Study on the hydrogen embrittlement crack susceptibility of stainless steel overlaid weld metal (1))

  • 이영호
    • Journal of Welding and Joining
    • /
    • 제8권3호
    • /
    • pp.39-52
    • /
    • 1990
  • The research is to insure the soundness of the stainless steel overlaid weld metal(21/4Cr-IMo steel + SUS 309L) for a pressure vessel application. Detail studies were conducted for the PWHT influence on the micrstructure and intergranular corrosion characteristics of the overlaid weld metal as well as initiation of hydrogen embrittlement crack(or Disbonding) when welded metal are exposed to the hydrogen atmosphere. Hydrogen was experimentally charged to the overlaid weld metal in order to study PWHT effect on the susceptibility of hydrogen embrittlement crack. The results of this research are as follows: 1. At the bond region, austenite grain of the stainless steel side became coarsed and Cr23C6 type carbide was precipitated at the coarsed austenitic grain boundaries. Intergranular Corrosion width(by Straiss test) increased with increasing PWHT temperature and PWHT time.

  • PDF

발청 염화물이온 임계값 평가를 위한 실험적 연구 (An Experimental Study to Evaluate the Critical Value of Chloride Ions on Rust)

  • 조규환;임명현;변정환;박동천
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.59-60
    • /
    • 2014
  • To prevent the rusting of steel, a variety of finishing materials has been applied. When steel is exposed to an extreme chloride environment, however, the thermal performance and aging of the finishing materials cause the material to lose its rust protective performance. In this study, an accelerated corrosion test was performed on five different finishing materials for steel, to determine the critical values of corrosion. As the result, the critical value of corrosion was found with no coat between 0.58mg/d㎡ and 0.73mg/d㎡, with urethane coat between 7.89mg/d㎡~8.46mg/d㎡, with one-layered red lead coat between 57.95mg/d㎡ and 69.48mg/d㎡, and with staleness201 between 80.73mg/d㎡ and 89.35mg/d㎡.

  • PDF

강재의 마감재로 사용된 도료별 비래염분 부착량 평가 (An Evaluation on Adhesive Weight of Incoming Salt by Paint used for Finishing Material of Steel)

  • 조규환;이영준;김우재;박동천
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.177-178
    • /
    • 2013
  • Steel structures of the seaside area are naturally led to surface corrosion due to incoming salt. Signature measures for this are to replace steel with steel material with a high corrosion-resistance and to block salt and other deteriorative factors beforehand through finishing work such as surface coating. However, the variety in steel materials, finishing type, and construction methods makes adhesive weight of incoming salt different depending on each type. For this research, measurement results derived from an enhancement experiment on artificial incoming salt adhesive to 4 steel finishing types and 2 material types identified a difference of adhesive weight by each sampler.

  • PDF

RC조 구조물의 최적 음극방식 조건 설정을 위한 함수율의 영향에 대한 평가 (Effect of Moisture on the Current Density for Optimized Cathodic Protection Condition in RC Structures)

  • 박동천;조규환;안재철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.29-30
    • /
    • 2013
  • Steel corrosion is the most serious problem in RC structures. Even though patch repair method is normally applied in repair system, the effectiveness is not enough. Cathodic protection in active repair method to deteriorated RC structures. FEM model was developed to simulate the optimized cathodic protection condition. Iro oxidation, hydrogen evolution and oxygen reduction were considered to expect current distribution. Moisture content in concrete which can affect the electrolyte conductivity was used as initial condition.

  • PDF

동관에서 pH, 알칼리도, 염소이온이 부식에 미치는 영향 (Effects of pH, Alkalinity, Chloride Ion on the Copper Pipe Corrosion)

  • 조관형;김선일;우달식
    • 한국환경보건학회지
    • /
    • 제33권1호
    • /
    • pp.43-48
    • /
    • 2007
  • This study investigated the effects of pH, alkalinity, and chlorine ion which are important water quality impact factors to the corrosion in the simulated distribution system where the copper pipe is affixed. The result shows that pitting index was increased as the alkalinity and chloride ion increase in the distilled water, but there was no relation to pH. Actually the uniform corrosion rate was decreased as the pH increase with the laboratory tap water. In conclusion, it is necessary to control the pH which stands above minimum 7.5 to prevent pitting corrosion in the copper pipe. Consequently, comprehensive research about the effect of lime soda($Ca(OH)_2$) which was used as a coagulation additive in the water treatment plant to pipe corrosion must be accomplished additionally.

EG수지피복강판의 전도성 향상을 위한 표면처리 된 나노금속분말의 도입효과 (Effect of Surface-treated Nano-metals on the improvement of Electrical Conductivity of Organic Resin Coated Steel Sheets)

  • 이재순;조재동;심상은;이재륭
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2009년도 추계학술대회 초록집
    • /
    • pp.108-108
    • /
    • 2009
  • 가전분야에서 EG강판 위에 피복된 크롬-프리 코팅은 내식성 및 심미성 이외에도 전기전도성이 요구되는데 이는 가전기기로 사용되므로 전자파 차폐성 및 용접성을 부여하기 위함이다. 내식성의 관점에서 보면 코팅된 수지 부착량이 많을수록 부식인자의 침투를 방해하여 내식성이 향상되나 일정한 부착량 이상에서는 전기전도성이 취약해지는 단점을 가지게 된다. 따라서 본 연구에서는 수지내에 나노금속분말을 고르게 분산시키는 연구 및 이를 이용하여 기존의 수지두께 이상에서도 전기전도성을 가질 수 있는 강판을 연구하였다.

  • PDF

원자력발전소 냉각수 정화계통의 핵종누적량 예측기법

  • 이재민;황주호
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 추계학술발표회논문집(2)
    • /
    • pp.590-595
    • /
    • 1996
  • 원자력발전소 냉각수 정화장치내의 운전중 핵종누적량을 계산하기 위하여 계산 프로그램을 작성하여 그 적용성을 평가하였다. 발전소내 측정자료를 재구성한 모의자료를 통한 검증 및 실험을 통해 프로그램의 핵종누적량 계산을 검증하였다. 모의 발전소 측정자료를 통한 예측기법의 적용성 평가에서는 제염계수 측정시 마다 제염계수의 변화폭이 클수록 본방법의 정확성이 상대적으로 향상되었다. 실험을 통한 검증에서는 일련의 정화장치를 통과하여 저장조에 수집된 모의냉각수내 핵종농도를 분석하여 정화장치내에 누적된 핵종량을 계산, 그 결과를 본방법에서의 계산값과 비교를 하였다. 본방법의 계산값의 오차가 상대적으로 작았으며 앞서 수행한 부식생성물의 운전상황에 따른 제염효율 변화예측에 있어서도 본방법이 제염효율 변화를 추적할 수 있음을 알 수 있었다.

  • PDF