• Title/Summary/Keyword: 부배열

Search Result 566, Processing Time 0.03 seconds

Non-Destructive Testing of Damaged Thermoplastic Pipes Electrofusion Joints Using Phased Array Ultrasonic (위상배열초음파를 이용한 손상된 열가소성 플라스틱배관 전기융착부 비파괴검사)

  • Kil, Seong-Hee;Kim, Byung-Duk;Kwon, Jeong-Rock;Yoon, Kee-Bong
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.5
    • /
    • pp.64-68
    • /
    • 2013
  • Non destructive testing(NDT) methods of electrofusion(EF) joints of thermoplastics pipes are required for fusion joint safety and for the long term reliability of a pipe system. Electrofusion joints, which are joined at the proper fusion process and procedures, may encounter defects due to the difference of ovality between pipes and coupling, improper fusion process or porosity result from electrofusion joining. These defects can cause the failure of pipeline and by extension, they can be caused the limit to expand the use of plastics pipes. This paper studies inspection results using ultrasonic imaging method for damaged polyethylene electrofusion joints. Gas was leaking from 250mm diameter polyethylene electrofusion joints at February 2004 which was electrofused at December 1994 and operation pressure was 2.45kPa. First, surface inspection was conducted and then in order to find the types of defects examination using ultrasonic imaging method was performed. Lack of fusion and inappropriate inserting for polyethylene pipes into electrofusion coupling were found and causes of the gas leak were judged that misalignment and insert defect. Cutting inspection was performed and each inspection results were compared to. Results of ultrasonic imaging method and cutting inspection were the same.

A Study on TOFD Inspection Using Phased Array Ultrasonic Technique (위상배열 초음파 기법을 이용한 TOFD 검사에 관한 연구)

  • Yoon, Byung-Sik;Kim, Yong-Si;Lee, Hee-Jong;Lee, Young-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.4
    • /
    • pp.304-310
    • /
    • 2005
  • The techniques in order to measure the depth of defect in weldment and structure accurately have been developed. Many researches have made efforts to develop the methods for the accurate depth sizing of defect. TOFD is known as the most accurate method of various methods for measuring depth sizing. However, there is a possibility to miss defects because of the limitation of beam coverage for the ultrasound incident angle. In this study, the results for detectability and depth sizing using phased array ultrasonic technique for thick body were compared with those of conventional TOFD technique. It was experimentally confirmed that the phased array ultrasonic TOFD technique gives good detectability and accurate depth measurement for the various types of defects. The phased array ultrasonic TOFD technique developed in this study will contribute to increase the inspection reliability in thick component such as the pressure vessel of power generation industry.

The Effects of Various Burner Array on Workpiece and Gas Temperature in a Continuous Reheating Furnace (연속식 가열로에서 버너배열에 따른 소재 및 가스온도의 영향)

  • Kim, Kang-Min;Jeon, Chung-Hwan;Yoo, In;Kim, Gyu-Bo
    • Journal of Energy Engineering
    • /
    • v.26 no.2
    • /
    • pp.23-31
    • /
    • 2017
  • Numerical study was conducted for the effects of various burner array on the workpiece and the gas temperature in a continuos reheating furnace. Under the same conditions which were the total heat of combustion, the heat capacity of unit burner, the number of burner and burner array were changed to be applied the furnace. The behavior of workpiece temperature and gas temperature in a furnace were evaluated for the effects as function of the changed conditions. A continuous reheating furnace designed for 110 tons/day of production capacity was applied in this study. The furnace which has several gas burners is designed to heat a workpiece. By this study, the better condition was confirmed than the existing designed condition.

Flaw Discrimination for Welding Points in Boiler Tubes by Phased Array Ultrasonic Testing (위상배열초음파탐상검사에 의한 보일러관 용접부의 결함 판별)

  • Cho, Kuk-Hyung;Yoo, Ho-Seon
    • Plant Journal
    • /
    • v.14 no.2
    • /
    • pp.45-50
    • /
    • 2018
  • Nuclear safety law's amendment caused many problems to use radiography testing(RT). Phased array ultrasonic testing(PAUT) was adapted instead of RT for NDE of welding points in boiler tubes these days. Unfortunately, PAUT doesn't give us the discrimination characteristics about flaws distinction and flaws size clearly. In this thesis, the distinction characteristics of flaw types and the detection characteristics of flaw size using PAUT of welding points in boiler tubes were analyzed. It was concluded that PAUT can distinguish between planar flaws and rounded flaws, but it is hard to tell apart the types of flaw respectively. We paid attention to the discrimination of flaws size because PAUT tends to underestimate the flaw size of porosity and underestimate or overestimate the flaw size of porosity.

  • PDF

Analysis of the Sleeve Dipole Array Antennas Using the Moment Method (모멘트 법을 이용한 슬리브 다이폴 배열안테나의 해석)

  • 배남진;최학근
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.7
    • /
    • pp.973-984
    • /
    • 1999
  • This paper presents a method of moments with the transmission line theory to analyze the sleeve dipole array antennas and analyses characteristics of that. There were several considerations for analysis of the method of moments. First, the method of moments were applied at both of the sleeve dipole elements and the coaxial line because the current flows on both of them. Second, the feed voltages of each sleeve dipole element were obtained by using a transmission line theory because the feeding structure is fed by coaxial line in series. Third, the series reactance between the coaxial line and the open side of the sleeve was considered as impedance loading on the antenna. The radiation patterns and current distributions from the numerical results were considered as variation of the feed distances and frequencies. To verify the validity of our method, 4 elements sleeve dipole array antennas with 1 λg distance were fabricated and measured, and then the measured radiation patterns were compared with the numerical results. The measured results were confirmed a good agreement with the numerical results.

  • PDF

Configuration of a 16-Element Array Antenna Design to Improve Signal Detection Performances (신호탐지 정확도를 높이기 위해 최적 배열형상을 고려한 16소자 배열안테나 설계)

  • Jang, Doyoung;Yoo, Sungjun;Wang, Jinchun;Lee, Jun-Yong;Choo, Hosung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.6
    • /
    • pp.438-444
    • /
    • 2019
  • In this paper, we proposed a 16-element array antenna design to improve signal detection performances. The array antenna characteristics, such as mutual coupling, pattern deviation, and half power beamwidth of the active element, were examined to obtain an optimal spacing between individual elements. The single element of the array antenna consists of an indirect feed using L-shaped feed and shorted radiating patch to achieve a broadband operation. Root mean square(RMS) errors based on the incident angle of the signal were calculated to verify the signal detection performance of the proposed antenna. The results demonstrate that the proposed array antenna with optimal spacing is suitable for detecting interference signals with low RMS error.

Analysis of Computational Complexity for Cascade AOA Estimation Algorithm Based on Single and Double Rim Array Antennas (단일 및 이중 림 어레이 안테나 기반 캐스케이드 AOA 추정 알고리즘의 계산복잡도 분석)

  • Tae-Yun, Kim;Suk-Seung, Hwang
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.6
    • /
    • pp.1055-1062
    • /
    • 2022
  • In order to use the Massive MIMO (Multi Input Multi Output) technology using the massive array antenna, it is essential to know the angle of arrival (AOA) of the signal. When using a massive array antenna, the existing AOA estimation algorithm has excellent estimation performance, but also has a disadvantage in that computational complexity increases in proportion to the number of antenna elements. To solve this problem, a cascade AOA estimation algorithm has been proposed and the performance of a single-shaped (non)massive array antenna has been proven through a number of papers. However, the computational complexity of the cascade AOA estimation algorithm to which single and double rim array antennas are applied has not been compared. In this paper, we compare and analyze the computational complexity for AOA estimation when single and double rim array antennas are applied to the cascade AOA estimation algorithm.