• Title/Summary/Keyword: 복합 치아종

Search Result 38, Processing Time 0.02 seconds

MICROLEAKAGE OF COMPOSITE RESIN RESTORATION ACCORDING TO THE NUMBER OF THERMOCYCLING (열순환 횟수에 따른 복합레진의 미세누출)

  • Kim, Chang-Youn;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.377-384
    • /
    • 2007
  • Present tooth bonding system can be categorized into total etching bonding system (TE) and self-etching boding system (SE) based on their way of smear layer treatment. The purposes of this study were to compare the effectiveness between these two systems and to evaluate the effect of number of themocycling on microleakage of class V composite resin restorations. Total forty class V cavities were prepared on the single-rooted bovine teeth and were randomly divided into four experimental groups: two kinds of bonding system and another two kinds of thermocycling groups. Half of the cavities were filed with Z250 following the use of TE system, Single Bond and another twenty cavities were filled with Metafil and AQ Bond, SE system. All composite restoratives were cured using light curing unit (XL2500, 3M ESPE, St. Paul, MN, USA) for 40 seconds with a light intensity of $600mW/cm^2$. Teeth were stored in distilled water for one day at room temperature and were finished and polished with Sof-Lex system. Half of teeth were thermocycled 500 times and the other half were thermocycled 5,000 times between $5^{\circ}C$ and $55^{\circ}C$ for 30 second at each temperature. Teeth were isolated with two layers of nail varnish except the restoration surface and 1 mm surrounding margins. Electrical conductivity (${\mu}A$) was recorded in distilled water by electrochemical method. Microleakage scores were compared and analyzed using two-way ANOVA at 95% level. From this study, following results were obtained: There was no interaction between variables of bonding system and number of thermocycling (p = 0.485). Microleakage was not affected by the number of thermocycling either (p = 0.814). However, Composite restoration of Metafil and AQ Bond, SE bond system showed less microleakage than composite restoration of Z250 and Single Bond, TE bond system (p = 0.005).

The Effect of Three Surface Sealants on Microleakage of Class V Composite Resin Restorations (복합레진으로 수복한 5급 와동의 미세누출에 대한 3종의 레진 표면 전색제의 효과)

  • Lee, Won-Cheol;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.182-190
    • /
    • 2009
  • Statement of problem: Microleakage at the occlusal and gingival margin of Class V cavities restored with composite resin has traditionally been considered an obstacle to successful restoration. Purpose: The aim of this study was to assess the effectiveness of three different surface sealants(Fortify, Permaseal and Biscover LV) on the marginal sealing of Class V light-activated composite resin restorations(Z250). Material and methods: Forty noncarious human premolars and molars extracted within a three-month period were selected. Class V cavities with the occlusal margin in enamel and gingival margin in cementum were prepared in both buccal and lingual surfaces. The teeth, randomly assigned in four groups with twenty cavities in each group, were restored with composite resin after applying an adhesive system(Clearfil SE bond). After the finishing and polishing procedures, the restorations were covered with a specific surface sealants, except for the control samples, which were not sealed. After placing restorations, the specimens were thermocycled, and immersed in a 2% methylene blue solution for twenty four hours and sectioned longitudinally. The marginal microleakage was evaluated at the occlusal and gingival interfaces using a microscope and compared among the four groups using ANOVA test and Wilcoxon Rank-Sum test($\alpha$=0.05). Results: Statistical analysis showed that there was significantly less leakage when the surface sealants were used than there was in control group(P<.05). There were no significant differences of microleakage at occlusal and gingival margins among groups. There were no significant differences between microleakage of occlusal and gingival margins in each group. Fortify was not statistically different from control group at the gingival margin(P>.05). Conclusion: Application of surface sealants was an effective method of surface coating in reducing microleakage at occlusal and gingival margins of Class V composite resin restorations. However, it is certain that some microleakage still occurred despite the application of surface sealants, especially gingival margins.

COMPARISON OF MICROLEAKAGE WITH THREE DIFFERENT ADHESIVE SYSTEMS (수 종의 복합레진 접착 시스템에서의 미세 누출의 비교)

  • Seok, Choong-Ki;Nam, Dong-Woo;Nam, Soon-Hyeun;Kim, Young-Jin;Kim, Hyun-Jung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.636-644
    • /
    • 2004
  • Recently, self-etching adhesive system have been developed and bonding procedures simplified into one or two steps, which are simultaneously applied to both enamel and dentin. These systems are easy to use and have the potential for good clinical success. The purpose of this study is to evaluate in vitro the microleakage on the cementum/dentin and enamel walls in composite resin restoration of Class V cavities, regarding the use of different adhesive systems. 30 human premolars were divided into 3 groups. A standardized Class V preparation was prepared on the buccal and lingual surface of each premolar. The preparation were made parallel to the cementoenamel junctions, with the gingival half of the preparation extending 1mm apical to the cementoenamel junction. After adhesive system was applied to teeth as manufacture's recommendation, hybrid resin composite was filled in bulk into the preparation and light polymerized according to manufacturer's recommendations. Specimen were stored in distilled water at $37^{\circ}C$ for 5 days and thermocycled 1000 times ($5^{\circ}C{\pm}2^{\circ}C\;and\;55^{\circ}C{\pm}2^{\circ}C)$, then immersed in a 2% methylene blue solution for 12 hours. After sectioning mesio distally through the restorations, the degree of dye penetration was scored under a stereomicroscope at ${\times}\;25$ magnification. The data were analyzed statistically using t-test and one-way ANOVA. The results were as follows: ${\cdot}$ There is no adhesive system which can prevent microleakage perfectly. ${\cdot}$ There is significant difference in microleakage between enamel margin and dentin margin (p<0.0001). ${\cdot}$ In enamel margin, self-etching primer systems did not show any significant difference comparing total-etching system. In denin margin, self-etching primer systems did not show any significant difference comparing one-bottle adhesive system used in combination with total-etching.

  • PDF

QUANTITATIVE COMPARISON OF PERMEABILITY IN THE ADHESIVE INTERFACE OF FOUR ADHESIVE SYSTEMS (열순환 후 상아질 접착 계면의 수분 투과성 변화에 대한 정량적 분석)

  • Chang, Ju-Hea;Yi, Kee-Wook;Kim, Hae-Young;Lee, In-Bog;Cho, Byeong-Hoon;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.1
    • /
    • pp.51-60
    • /
    • 2009
  • The purpose of this study was to perform quantitative comparisons of water permeable zones in both the adhesive and the hybrid layer before and after thermo cycling in order to assess the integrity of the bonding interface. Twenty eight flat dentin surfaces were bonded with a light-cured composite resin using one of four commercial adhesives [OptiBond FL (OP), AdheSE (AD), Clearfil SE Bond (CL). and Xeno III (XE)]. These were sectioned into halves and subsequently cut to yield 2-mm thick specimens; one specimen for control and the other subjected to thermocycling for 10,000 cycles. After specimens were immersed in ammoniacal silver nitrate for 24 h and exposed to a photo developing solution for 8 h, the bonded interface was analyzed by scanning electron microscopy (SEM) and wavelength dispersive spectrometry (WDS) at five locations per specimen. Immediately after bonding. the adhesive layer of OP showed the lowest silver uptake, followed by CL, AD. and XE in ascending order (p < 0.0001); the hybrid layer of CL had the lowest silver content among the groups (p = 0.0039). After thermocycling, none of the adhesives manifested a significant increase of silver in either the adhesive or the hybrid layer. SEM demonstrated the characteristic silver penetrated patterns within the interface. It was observed that integrity of bonding was well maintained in OP and CL throughout the thermocycling process. Adhesive-tooth interfaces are vulnerable to hydrolytic degradation and its permeability varies in different adhesive systems, which may be clinically related to the restoration longevity.

The nanoleakage patterns of experimental hydrophobic adhesives after load cycling (Load cycling에 따른 소수성 실험용 상아질 접착제의 nanoleakage 양상)

  • Sohn, Suh-Jin;Chang, Ju-Hae;Kang, Suk-Ho;Yoo, Hyun-Mi;Cho, Byeong-Hoon;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.1
    • /
    • pp.9-19
    • /
    • 2008
  • The purpose of this study was: (1) to compare nanoleakage patterns of a conventional 3-step etch and rinse adhesive system and two experimental hydrophobic adhesive systems and (2) to investigate the change of the nanoleakage patterns after load cycling. Two kinds of hydrophobic experimental adhesives, ethanol containing adhesive (EA) and methanol containing adhesive (MA), were prepared. Thirty extracted human molars were embedded in resin blocks and occlusal thirds of the crowns were removed. The polished dentin surfaces were etched with a 35 % phosphoric acid etching gel and rinsed with water. Scotchbond Multi-Purpose (MP), EA and MA were used for bonding procedure. Z-250 composite resin was built-up on the adhesive-treated surfaces. Five teeth of each dentin adhesive group were subjected to mechanical load cycling. The teeth were sectioned into 2 mm thick slabs and then stained with 50 % ammoniacal silver nitrate. Ten specimens for each group were examined under scanning electron microscope in backscattering electron mode. All photographs were analyzed using image analysis software. Three regions of each specimen were used for evaluation of the silver uptake within the hybrid layer. The area of silver deposition was calculated and expressed in gray value. Data were statistically analyzed by two-way ANOVA and post-hoc testing of multiple comparisons was done with the Scheffe's test. Silver particles were observed in all the groups. However, silver particles were more sparsely distributed in the EA group and the MA group than in the MP group (p < .0001). There were no changes in nanoleakage patterns after load cycling.

IN VITRO STUDY OF CARIOGENIC POTENTIAL OF INFANT CONFECTIONARIES (유아용 과자의 우식유발능에 관한 생체 외 연구)

  • Song, Ji-Hyon;Lee, Kwang-Hee;Kim, Dae-Eup;Ra, Ji-Young;Lee, Dong-Jin;An, So-Youn
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.1
    • /
    • pp.39-46
    • /
    • 2008
  • The purpose of this study was to assess the cariogenic potential of infant confectionaries. In vitro, as compaired with 10% sucrose solution and whole bovine milk. Buffering capability were determined by amount of 0.1N lactic acid consumed to titrate the 50ml specimen solutions to pH 4.0. The pH of the specimen solution inoculated by streptococcus mutans was measured by pH meter and the surface microhardness tester, before and after 48 hours incubation. The buffering capacity of infant confectionaries was higher than that of sucrose solution and lower than that of milk, and there were significant difference between infant confectionaries(p<0.05). The pH of infant confectionaries after 48 hours incubation was similar to 10% sucrose solution, and there were significant difference between infant confectionaries and milk(p<0.05). The microhardness change of primary tooth enamel of infant confectionaries group after 48 hours incubation was similar to that of 10% sucrose solution, and there were significant difference between infant confectionaries and milk(p<0.05). In conclusion, infant confectionaries seemed to have the ability to cause dental caries in primary teeth, and there were significant differences of cariogenic potential among infant confectionaries. Cooperative efforts of dentistry and manufacturers to reduce the cariogenic potential of infant confectionaries would be necessary to prevent the early childhood caries in children.

  • PDF

CHEMICAL DEGRADATION OF VARIOUS COMPOMERS IN NaOH (콤포머의 NaOH 용액 내에서의 화학적 분해)

  • Park, Mi-Ran;Choi, Nam-Ki;Lee, Young-Jun;Kim, Seon-Mi;Yang, Kyu-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.144-152
    • /
    • 2004
  • The aim of this study was to evaluate the resistance to degradation of three commercial compomers in an alkaline solution. Dyract(Dentsply), Elan(Kerr) and F-2000(3M) polyacid modified resin composites(compomers) were used in this study. The resistance to degradation was evaluated on the basis of mass loss(%), degradation $depth({\mu}m)$ and Si, Al, Ba loss(ppm). The results were as follows : 1. The mass loss of each brand was $1.42%{\sim}2.14%$ and there was no statistically significant difference of mass loss among Dyract, F2000 and Elan. 2. The degradation layer depth of each brand was $182.92{\sim}227.7{\mu}m$ and there was no statistically significant difference of degradation layer depth among Dyract, F2000 and Elan. 3. There was statistically significant differences in Si-loss and Al-loss among three compomers (p<0.05). Si loss was the highest value in Dyract and Al loss was the highest value in F2000. 4. There was statistically significant correlation between mass loss and degradation layer depth (r=0.60, p<0.05). 5. In SEM finding, there was some destruction of compomer matrix-filler interface in post-exposure specimen to NaOH solution. As the matrix decreased, the filler particles distinguished and the periphery of the filler particles appeared whitish color due to degradation.

  • PDF

PROPOSAL OF NEW DENIAL COLOR-SPACE FOR AESTHETIC DENIAL MATERIALS (치과용 심미 수복 재료들의 색상 연구를 통한 새로운 치과용 색체계의 제안)

  • Oh, Yun-Jeong;Park, Su-Jung;Kim, Dong-Jun;Cho, Hyun-Gu;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.1
    • /
    • pp.19-27
    • /
    • 2007
  • The purpose of this study is to develope new dental color-space system. Twelve kinds of dental composites and one kind of dental porcelain were used in this study. Disk samples (15 mm in diameter, 4 mm in thickness) of used materials were made and sample's CIE $L^*a^*b^*$ value was measured by Spectrocolorimeter (MiniScan XE plus, Model 4000S, diffuse/$8^{\circ}$ viewing mode, 14.3 mm Port diameters, Hunter Lab USA) The range of measured color distribution was analyzed. All the data were applied in the form of T### which is expression unit in CNU Cons Dental Color Chart. The value of $L^*$ lies between 80.40 and 52.70. The value of $a^*$ are between 10.60 and 3.60 and $b^*$ are between 28.40 and 2.21. The average value of $L^*$ is 67.40, and median value is 67.30. The value of $a^*$ are 2.89 and 2.91 respectively. And for the $b^*$, 14.30 and 13.90 were obtained. The data were converted to T### that is the unit count system in CNU-Cons Dental Color Chart. The value of $L^*$ is converted in the first digit of the numbering system. Each unit is 2.0 measured values. The second digit is the value of $a^*$ and is converted new number by 1.0 measured value. For the third digit $b^*$ is replaced and it is 2.0 measured unit apart. T555 was set to the value of $L^*$ ranging from 66.0 to 68.0, value of $a^*$ ranging from 3 to 4 and $b^*$ value ranging from 14 to 16.