• Title/Summary/Keyword: 복합 영상 잡음

Search Result 85, Processing Time 0.025 seconds

Density Profile Evaluation of Needle-punched Carbon/Carbon Composites Nozzle Throat by the Computed Tomography (전산화 단층촬영에 의한 니들펀칭 탄소/탄소 복합재료 노즐 목삽입재의 밀도 분포 평가)

  • Kim Dong-Ryun;Yun Nam-Gyun;Lee Jin-Yong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.1
    • /
    • pp.44-53
    • /
    • 2006
  • In this study, the non-destructive computed tomography was adopted to observe the density profile of the needle-punched Carbon/Carbon(C/C) composites nozzle throat. The density profile of C/C was evaluated within ${\pm}0.01g/cm^3$ with 98.74% confidence when the correction of the image and high signal-to-noise ratio were achieved by the optimization of the beam hardening, the electrical noise and the scattered X-ray. The density variation of C/C with the computed tomography was in good agreement with the results obtained by the water immersion method and the observation with scanning electron microscope.

Nonlinear Composite Filter for Gaussian and Impulse Noise Removal (가우시안 및 임펄스 잡음 제거를 위한 비선형 합성 필터)

  • Kwon, Se-Ik;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.3
    • /
    • pp.629-635
    • /
    • 2017
  • In this paper, we proposed a nonlinear synthesis filter for noise reduction to reduce the effects of Gaussian noise and impulse noise. When the centralization of the local mask is judged to be Gaussian noise by the noise judgment, the weight value of the weight filter are applied differently according to the spatial weight filter and the pixel change by using the sample variance in the local mask. And if it is determined as the impulse noise, we proposed an algorithm that applies different weights of local histogram weight filter and standard median filter according to noise density of mask. In order to evaluate the performance of the proposed filter algorithm, we used PSNR(peak signal to noise ratio) and compared existing methods and proposed filter algorithm in the mixed noise environment with Gaussian noise, impulsive noise, and two noises mixed.

Hybrid Camera System with a TOF and DSLR Cameras (TOF 깊이 카메라와 DSLR을 이용한 복합형 카메라 시스템 구성 방법)

  • Kim, Soohyeon;Kim, Jae-In;Kim, Taejung
    • Journal of Broadcast Engineering
    • /
    • v.19 no.4
    • /
    • pp.533-546
    • /
    • 2014
  • This paper presents a method for a hybrid (color and depth) camera system construction using a photogrammetric technology. A TOF depth camera is efficient since it measures range information of objects in real-time. However, there are some problems of the TOF depth camera such as low resolution and noise due to surface conditions. Therefore, it is essential to not only correct depth noise and distortion but also construct the hybrid camera system providing a high resolution texture map for generating a 3D model using the depth camera. We estimated geometry of the hybrid camera using a traditional relative orientation algorithm and performed texture mapping using backward mapping based on a condition of collinearity. Other algorithm was compared to evaluate performance about the accuracy of a model and texture mapping. The result showed that the proposed method produced the higher model accuracy.

Phase Noise Evaluation of Multi-mode based-COMS Communication Transponder (다중모드 기반 천리안 위성통신 중계기의 위상잡음 특성 평가)

  • Kim, Young-Wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.1
    • /
    • pp.20-25
    • /
    • 2012
  • The COMS, which is a multi-purposed satellite that provide the oceanic measurement data and meterological image data, is operating since 2010. Ka-band satellite communication transponder in COMS gets the MSM function that can provide the required multi-beam and transmits the multi-mode signal with high data rate. The phase noise of COMS communication transponder can be increased because of several local oscillators for MSM function and the utilization of Ka-band frequency. The phase noise affects the performance for the multi-mode and high rate data based- transmission method, it is not possible to recover the transmission data in system with the high system phase noise. In this paper, the phase noise of COMS was measured and the effects of the measured phase noise are analysed and evaluated in the viewpoint of the noise bandwidth of transmission system, Also the transmission performances for multi-mode and high rate data are evaluated in the presence of COMS phase noise.

Image Compression by Linear and Nonlinear Transformation of Computed Tomography (전산화단층촬영의 선형과 비선형변환에 의한 영상압축)

  • Park, Jae-Hong;Yoo, Ju-Yeon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.509-516
    • /
    • 2019
  • In the linear transformation method, the original image is divided into a plurality of range blocks, and a partial transform system for finding an optimal domain block existing in the image for each range block is used to adjust the performance of the compression ratio and the picture quality, The nonlinear transformation method uses only the rotation transformation among eight shuffle transforms. Since the search is performed only in the limited domain block, the coding time is faster than the linear transformation method of searching the domain block for any block in the image, Since the optimal domain block for the range block can not be selected in the image, the performance may be lower than other methods. Therefore, the nonlinear transformation method improves the performance by increasing the approximation degree of the brightness coefficient conversion instead of selecting the optimal domain block, The smaller the size of the block, the higher the PSNR value, The higher the compression ratio is increased groups were quadtree block divided to encode the image at best.

A Road Extraction Algorithm using Mean-Shift Segmentation and Connected-Component (평균이동분할과 연결요소를 이용한 도로추출 알고리즘)

  • Lee, Tae-Hee;Hwang, Bo-Hyun;Yun, Jong-Ho;Park, Byoung-Soo;Choi, Myung-Ryul
    • Journal of Digital Convergence
    • /
    • v.12 no.1
    • /
    • pp.359-364
    • /
    • 2014
  • In this paper, we propose a method for extracting a road area by using the mean-shift method and connected-component method. Mean-shift method is very effective to divide the color image by the method of non-parametric statistics to find the center mode. Generally, the feature points of road are extracted by using the information located in the middle and bottom of the road image. And it is possible to extract a road region by using this feature-point and the partitioned color image. However, if a road region is extracted with only the color information and the position information of a road image, it is possible to detect not only noise but also off-road regions. This paper proposes the method to determine the road region by eliminating the noise with the closing / opening operation of the morphology, and by extracting only the portion of the largest area using a connected-components method. The proposed method is simulated and verified by applying the captured road images.

A Robust Content-Based Image Retrieval Technique for Distorted Query Image (변형된 질의 영상에 강한 내용 기반 영상 검색 기법)

  • 김익재;이제호;권용무;박상희
    • Journal of Broadcast Engineering
    • /
    • v.2 no.1
    • /
    • pp.74-83
    • /
    • 1997
  • We have proposed a composite feature measure which combines the color and shape features of an image for image retrieval. We improved the performance of retrieval based on the efficient color quantization using the Lloyd-Max quanizer and on the Histogram matrix matching method which considers the spatial correlation of quantized color group. We also supplemented the color information using shape information with the Improved Moment Invarlants. We have tested our technique on Image database consisting of 200 actual trademark images. Our experimental results showed that our approach improved the performance compared to the previous method under the various situations such as rotation images, translation images, noise added images, gamma corrected images and so on. The efficiency of retrieval is found to be very high and experimental results are

  • PDF

Quantitative, qualitative Evaluation of Diffusion-Weighted MRI using Optimal b-value(s/mm2) for Female Pelvis (여성골반에 대한 최적의 b-value(s/mm2)를 이용한 확산강조 자기공명영상의 정량적, 성적 평가)

  • Goo, Eun-Hoe
    • Journal of Digital Convergence
    • /
    • v.11 no.1
    • /
    • pp.361-368
    • /
    • 2013
  • The purpose of this study is to know the clinical usefulness of optimal b-values by quantitative, qualitative evaluation of DW-MRI for lesions of benignity and malignity of female pelvis. The b-values used in DWI were 600, 800, 1000, 1200, 1400($s/mm^2$). Mean SNR and CNR of myoma in b-value 800 were the highest result as $84.6{\pm}4.57$(p=0.024) and $50.13{\pm}5.47$(p=0.028), Mean SNR and CNR of cervical cancer were the highest result as $12.0{\pm}2.04$(p=0.047) and $10.6{\pm}1.24$(p=0.001), Mean ADC value in myoma and cervical cancer in b-value 800 were $1.19{\times}10^{-3}mm^2/s$(p=0.008), $0.96{\times}10^{-3}mm^2/s$(p=0.027). As a qualitative analysis, the delineation and conspicuity were the highest result as $4.02{\pm}0.18$(p=0.028), $4.39{\pm}0.25$(p=0.015) on b-value 800. DW-MRI is an important method, and the optimal b values is 800 $s/mm^2$ for differentiation between benign and malignant lesions of female pelvis.

Intelligent Interference Cancellation using Adaptive Controller for Collocated Radios (적응형 제어기를 이용한 간섭 잡음 제거 기법)

  • Park, Yong-Un;Kim, Dong-Hyeon
    • Broadcasting and Media Magazine
    • /
    • v.13 no.4
    • /
    • pp.65-79
    • /
    • 2008
  • 최근 TV 디지털 방송에 대한 많은 관심이 집중되면서 국내의 디지털 텔레비전 방송(Digital Multimedia Broadcasting: DMB)과 유럽의 디지털 텔레비전 방송((Digital Video Broadcasting: DVB)에 대한 기술 개발이 지속적으로 이루어지고 있다. 국내의 DMB는 지상파 DMB와 위성 DMB가 있고, 유럽의 DVB는 일반 방송국으로부터 가정용 또는 사무실용의 고정된 장치에서 수신을 하는 DVB-T와, 휴대 전화기나 휴대용 영상기기 등의 저전력, 이동성, 휴대성을 고려한 DVB-H가 있다. 또한 휴대폰이나 PDA와 같은 휴대 통신단말기의 기능복합화 요구에 따라, 국내에서는 휴대폰에 TV 방송기능과 인터넷을 이용할 수 있는 네트워크 서비스가 내장된 단말기가 속속 출시되어 치열한 경쟁구도에 접어들고 있다. 이러한 시장요구에 부응하기 위해 다양한 분야에서 기능 복합화를 실현하고자 하는 " Ubiquitous Convergence화"가 급속도로 진행되고 있다. 그러나 단일 시스템에서 2가지 이상의 기능(GSM/GPRS & DVB-H)이 Convergence화 되어있을 경우, 시스템 상호간 간섭영향으로 각 장치의 기능 저하가 발생하고 있다. 특히, 동일 주파수대역 사용에 의해 방생하는 간섭영향에 대한 적절한 대응이 요구되는 시점이다. 본 고에서는 무선 통신 분야 기술개발의 한 부분으로 부품의 초소형화 및 동일 주파수대역 사용에 의해 발생하는 간섭영향을 제거하는 내용에 대해서 기술한다.

Evaluation of Combined Contrast Agent using N-(p-maleimidophenyl) Isocyanate Linker-mediated Synthesis for Simultaneous PET-MRI (동시 PET-MRI를 위한 N-(p-maleimidophenyl) isocyanate linker-매개 합성을 이용한 복합 조영제의 평가)

  • Lee, Gil-Jae;Lee, Hwun-Jae;Lee, Tae-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.103-113
    • /
    • 2022
  • In this paper, a combined 18F-FDG(fluorodeoxyglucose) and MNP(magnetic nanoparticles) contrast agent was synthesized using N-(p-maleimidophenyl) isocyanate as the crosslinker for use in simultaneous PET-MRI scans. PET-MRI images were acquired and evaluated before and after injection of the combined contrast imaging agent (18F-FDG labeled MNP) from a glioma stem cell mouse model. After setting the region of interest (ROI) on each acquired image, the area of the lesion was calculated by segmentation. As a result, the PET image was larger than the MRI. In particular, the simultaneous PET-MRI images showed accurate lesions along with the surrounding soft tissue. The mean and standard deviation values were higher in the MRI images alone than in the PET images or the simultaneous PET-MRI images, regardless of whether the contrast agent was injected. In addition, the simultaneous PET-MRI image values were higher than for the PET images. For PSNR experiments, the original image was PET Image using 18F-FDG, MRI using MNPs, and MRI without contrast medium, and the target image was simultaneous PET-MRI image using 18F-FDG labeled MNPs contrast medium. As a result, all of them appeared significantly, suggesting that the 18F-FDG labeled MNPs contrast medium is useful. Future research is needed to develop an agent that can simultaneously diagnose and treat through SPECT-MRI imaging research that can use various nuclides.