• Title/Summary/Keyword: 복합재 보수

Search Result 78, Processing Time 0.028 seconds

An experimental study about the water leakage structure of waterproofing layer performance demobilization method using of stick expansion type complex of flexible material (점착$\cdot$팽창성 유연형 복합소재를 이용한 누수구조물의 방수층 성능복원공법에 관한 실험적 연구)

  • Jang Hyok-Soo;Kang Hyo-Jin;Song Je-Young;Oh Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.11a
    • /
    • pp.79-83
    • /
    • 2005
  • In the reinforced concrete structure, Even if speak that water leakage occurrence is no problem to material, there is a lot of reasons construction factor, material damage by behavior structure, properties of matter change by years and water leakage part by environment condition. so, waterproofing technological consideration should be gone ahead. In this research, we will study about stick performance, concrete surface adhesive, damage and blow. we will check all things and test it. The stick expansion type complex of flexible material passed on result of standard. It is conducive to concrete of durability by waterproofing layer performance demobilitation technology on the water leakage structure for solution of problem and repair

  • PDF

Crack Arrest Toughness of Thick Steel Plate Welds for Ship Building (선급 극후물 강재 용접부 취성균열 정지특성)

  • Park, Joon-Sik;Jung, Bo-Young;An, Gyu-Baek;Lee, Jong-Bong
    • Journal of Welding and Joining
    • /
    • v.25 no.4
    • /
    • pp.9-14
    • /
    • 2007
  • 선박의 고강도화 및 극후물화가 진행됨에 따라 선체 구조물의 파괴 특성에 대한 관심이 높아지고 있으며, 최근 균열정지의 관점에서 취성균열 정지특성에 대한 연구가 활발히 이루어지고 있다. 기존의 연구결과에 따르면 65mmt 이상의 극후물 용접부에 대해서 취성균열 정지특성의 저하가 발생할 가능이 있다고 보고되고 있으며, 취성균열 정지특성이 우수한 강재의 개발 이외에 용접부 보강재의 부착, 보수 용접 실시 등 개선 방안을 마련하기 위한 다양한 연구가 진행되고 있다. 그러나 극후물 용접부 취성균열 전파기구에 관한 규명은 현재 전무한 실정이며, 강재 두께의 영향 이외에 용접 입열량 용접부 잔류응력 등의 효과가 복합적으로 검토되어야 한다. 아울러 극후물 용접부 균열정지 파괴인성의 평가, 대형파괴시험을 대체할 소형시험법의 개발 및 검증 등에 관한 연구가 요구된다.

Performance Evaluation of Underground Pipe with In-Situ Recycled Controlled Low Strength Materials (현장발생토사 재활용 유동성채움재를 이용한 지하매설관의 거동평가)

  • Lee Kwan-Ho;Song Chang-Seob
    • International Journal of Highway Engineering
    • /
    • v.8 no.2 s.28
    • /
    • pp.1-12
    • /
    • 2006
  • An existing Steel pipe, Cast iron pipe and Concrete pipe is can not escaped from aging, specially Metal tube is causing many problems that the quality of water worse is concerned about many rust and mike efficient use of preservation of water. The use of Glassfiber Reinforced Plastic Pipe(GRP PIPE) should be one of the possible scheme to get over these problems. The GRP PIPE has an excellent resistance power and the life is lasting from 50 to 100 years roughly. It's to be useful as a result of high durability and a good construction work also it is a light weight therefore can be expected to short the time of construction and man power. In this research, to executed the small-scaled model test, in-situ model test using CLSM of in-situ soil and to evaluated the stress - strain of the pipe also try to estimated how useful is. From the model test in laboratory, the vertical and horizontal deformation of the GRP PIPE measured in six instance using 200mm and 300mm in diameters. The value of experimentation, theory, analysis got the same results of the test, but the vertical and horizontal deformation gauged in small and the earth pressure was almost zero using CLSM of in-situ soil..

  • PDF

Comparison of Mechanical Properties on Helical/Hoop Hybrid Wound HNT Reinforced CFRP Pipe with Water Absorption Behavior (CFRP 파이프의 와인딩 적층 패턴 설계 및 HNT 나노입자 보강에 따른 수 환경에서의 기계적 물성 평가)

  • Choi, Ji-Su;Park, Soo-Jeong;Kim, Yun-Hae
    • Composites Research
    • /
    • v.34 no.3
    • /
    • pp.174-179
    • /
    • 2021
  • Currently, fluid transfer steel pipes take a lot of time and expense to maintain all facilities due to new construction and painting or corrosion and aging. Therefore, this study was conducted for designing a CFRP pipe structure with high corrosion resistance and chemical resistance as a substitute for steel pipes. The helical/hoop pattern was cross-laminated to improve durability, and HNT was added to suppress the moisture absorption phenomenon of the epoxy. The HNT/CFRP pipe was manufactured by a filament winding process, and performed a mechanical property test, and a moisture absorption test in distilled water at 70℃. As a result, the highest bending strength was obtained when the hoop pattern was laminated with a thickness equivalent to 0.6% of the pipe. The 0.5 wt% HNT specimen had the highest moisture absorption resistance. Also, the delamination phenomenon at the interlayer interface was delayed, resulting in the lowest strength reduction rate.

Evaluation of Tensile Material Properties and Confined Performance of GFRP Composite Due to Temperature Elevation (콘크리트 횡구속용 GFRP 보강재의 온도변화에 따른 인장 재료특성 및 구속성능 평가)

  • Jung, Woo-Young;Kim, Jin-Sup;Kwon, Min-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.7
    • /
    • pp.3562-3569
    • /
    • 2013
  • The performance of concrete structure decreases with change in time and the external environment. In order to reinforce the structure, the research about new material development and application of newly developed materials are widely conducted. In the case of composite FRP, it received good attention in the academia due to its high intensity-weight ratio, excellent corrosion resistency as well as good workability. When applying at the construction field, however, the utilization of FRP did not increase as much due to lack of reliability and design standard. Current study investigated the material characteristics during the temperature change at high temperature and the structural behavior from restraint effect for GFRP reinforcing materials. Two experimental variables were set in this study: GFRP reinforcements due to tensile properties of temperature and restraint compression effects. Three concrete specimen were selected for each set temperatures. For this reason, as a variable to experiment with the effects confined compression concrete members value and tensile properties with temperature reinforcement GFRP, experiment produced three pieces each for each set temperature, the concrete specimen, which is confined in the GFRP was selected each I did. For the temperature change during the experiment, the concrete specimen were mounted in order to expose to experimental high temperature for certain period of time. For compression performance evaluation, reinforcement effect from horizontal constraint of the fiber were measured using an Universal Material Testing Machine (UTM). Finally, this study revealed that the binding characteristics of GFRP materials from temperature change decreased. Also, this study showed that the maximum compression intensity decreased as the temperature increased up to $150^{\circ}C$ in the constraints ability of the GFRP reinforcements during the horizontal constraint of concrete.

A Study on the Visualization of Ice-formation Phenomena of Bath Water to Decide Maintenance Period of Gas Heater (가스히터 보수주기 결정을 위한 히터내부 열전달 매체액 결빙현상 가시화에 관한 연구)

  • Lee J. H.;Ha J. M.;Sung W. M.
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.3 s.15
    • /
    • pp.1-8
    • /
    • 2001
  • This study was carried out for the purpose of determination of maintenance period and investigation of weak point due to freeze when the gas heater of KOGAS valve station Is not operated in winter season. 3-dimensional non-linear numerical simulation was conducted in order to predict the time and location which bath water in heater reaches to ice point. FLUENT V 5.0, commercial code, is used for thermal fluid flow analysis. We thought this was problem of heat conduction solving the energy equation and modeled gas heater by using the real geometry and scale for performing the 3-dimensional simulation. It was analyzed complex heat transfer phenomena considering convection due to air on surface, conduction in insulation material, natural convection of liquid in heater and heat loss through the pipe.

  • PDF

Linking OntoCloud to WordNet (OntoCloud와 워드넷 연결)

  • Park, Kwang-Hee;Kim, Eun-Kyung;Choi, DongHyun;Choi, Key-Sun
    • Annual Conference on Human and Language Technology
    • /
    • 2010.10a
    • /
    • pp.172-176
    • /
    • 2010
  • 본 논문에서는 위키피디아의 '틀(temp late)'을 기조로 하여 작성된 온톨로지인 OntoCloud의 신뢰도를 보장하고 공유 및 재사용을 가능하게 하기 위하여 또 다른 어휘집합체인 워드넷(WordNet)과의 매핑을 한다. 온톨로지 매핑 기술은 온톨로지 개발 기술의 한 방법으로, 서로 비슷한 도메인을 대상으로 이미 구축되어진 서로 다른 다수의 온롤로지를 연결시킴으로서 하나의 풍부한 정보를 가지고 있는 연결망을 구축하는 방법이다. 본 논문에서는 OntoCloud와 워드넷을 두개의 온톨로지로 정의하고 각 온톨로지의 개념에 대한 정의문 비교 방법을 통해서 두개의 온톨로지에 존재하는 유사한 개념을 연결한다. 이렇게 매핑된 정보들은 OntoCloud 개념을 워드넷 어휘로 연결함으로써 개념에 대한 직관적인 이해를 돕고, 워드넷에 연결된 다른 시소러스 (예: SUMO, CoreNet 등)와 간접적으로 연결할 수 있는 틀을 마련한다. 또한 온톨로지의 상하위 계층정보를 자동으로 보강하는 등의 OntoCloud 유지보수에 활용될 수 있다. 본 논문의 실험에서는 두개의 서로 다른 온톨로지의 정의문에 사용된 어휘의 겹침 정도로 두개의 개념의 유사성을 판별하는 방법을 보인다. 본 논문에서 제시한 방법으로 약 73%의 개념 매핑에 성공하였으나, 추후 매핑 프로세스의 전처리 과정(약자 처리 및 복합명사 대응 모듈)을 추가하고 온톨로지의 구조적 특성을 활용하여 유사 개념 자동 매핑 기술을 향상시키고자 한다.

  • PDF

Surface Deterioration Diagnosis of Taejong Heonreung Sindobi Monument using Nondestructive Method (비파괴 기법을 이용한 태종 헌릉 신도비의 표면 훼손도 진단)

  • Lee, Myeong-seong;Park, Sung-mi;Chun, Yun-gun;Lee, Sun-myung;Lee, Jae-man
    • Korean Journal of Heritage: History & Science
    • /
    • v.46 no.4
    • /
    • pp.90-107
    • /
    • 2013
  • The Stone Monument of Taejong King in Heonreung Royal Tomb, Seoul was originally erected in 1424 to pay a tribute to Bang Won Lee's achievement who was named Taejong, the Third King of Joseon Dynasty. The monument has been damaged by Japanese Invasion of Korea in 1592 so that another monument was newly made and erected together with the original monument in 1695. The original monument was made of medium-grained biotite granite for the turtle base and medium-grained milky white crystalline limestone for the stele body and the top stone. The turtle base of the original monument is destroyed beyond the original shape and inscription due to irregular shaped breaking and a set of longitudinal crack. Analyzing the deterioration degree by using nondestructive methods, the 88 percentage of the front area and 38 percentage of the back area of the monument are damaged, and the lower part of the stele body is dominantly deteriorated especially due to the combination of discoloration and physical deterioration. The new monument in 1695 is also made of granite and limestone. The weathering indices of the turtle base and stele body stones by the calculation from ultrasonic velocity are 0.10 and 0.74, respectively. This is because the original monument is presumed to be degraded by heat shock and physical attack during the Japanese war, and the long-term outdoor exposure accelerated the weathering of the monument afterward without protective shelter.

A Study on Hybrid Grout Material for Reservoir Embankment reinforcement (저수지 제방 보수보강을 위한 하이브리드형 그라우트재 연구)

  • Park, Sung-Yong;Shim, Houng-Gen;Kang, Hee-Jin;Lim, One-Bin;Sami, Ghazali-Flimban;Kim, Yong-Seong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.3
    • /
    • pp.21-30
    • /
    • 2017
  • Cement grouting method is generally applied for the purpose of reinforcement of deteriorated reservior. Problems have been raised due to the limit of the injection material. In order to solve these problems, various grout materials have been developed. However, there are many cases in which the grounds are disturbed in actual field. In this study, the physical properties of hybrid grout with high fineness and high viscosity characteristics were analyzed to enable penetration into the ground. Optimum inflation agent was selected and mixed with the grout. The pressure and compaction effect on expansion was examined and its effectiveness was verified. From the result of confirming expansion ratio, uniaxial compressive strength, expansion pressure and compaction effect, the HI-E (2%) sample was analyzed to be excellent in improvement effect by the inflation agent. Hence, hybrid grout can be effectively applied for the impermeable and reinforcement method of deterioration reservoir and tide embankment.

Geophysical Exploration of Songsalli Ancient Tombs and Analysis of King Muryeong's Tomb Structure, Gongju (공주 송산리 고분군(公州 宋山里 古墳群)에서의 물리탐사와 무령왕릉(武寧王陵)의 구조분석)

  • Oh, Hyun-dok
    • Korean Journal of Heritage: History & Science
    • /
    • v.46 no.4
    • /
    • pp.4-23
    • /
    • 2013
  • Songsalli Ancient Tombs of Gongju consists of seven tombs. King Muryeong's tomb, the seventh tomb, is a brick chamber tomb discovered during the drainage works for the fifth and the sixth tombs in 1971. The excavation at the time focused on topographic surveys of the tomb entrance and the inside of the burial chamber as well as collection of the remains. The burial mount survey confirmed the status of some stone slab remaining and lime-mixed soil layers, but the survey did not examine the exterior structure of the whole tomb as the mounds were removed even more deeply. The excavation revealed damages to the bricks and mural damages due to moisture and fungus in the sixth and the seventh tombs. Between 1996 and 1997, Gongju National University conducted a comprehensive detailed survey of Songsalli Ancient Tombs including a geophysical survey, with an aim to identify the root causes of such degradation. Based on the results, repair took place in 1999 and the fifth, sixth and seventh tombs were placed under permanent conservation to conserve the cultural assets. General public is currently denied access. The purpose of this study was to conduct a three-dimensional resistivity and GPR surveys on the ground surface of the fifth, sixth and seventh tombs of Songsalli Ancient Tombs in order to understand the underground status after repair. The study also aimed to understand the thickness of all the tomb walls and exterior structure based on GPR inside King Muryeong's tomb. The exploration on the ground surface found that the three tombs and soil adjacent to the tombs had resistivity as low as 5 to $90{\Omega}m$, which confirmed that the soil water content was still as high as that prior to the repair work. Additionally, GPR found that the wall construction of the burial chamber of King Muryeong's tomb was approximately 70cm in thickness, while the structure was of 2B with two bricks, about 35cm in length, put together longitudinally(2B brick masonry). The pathway to the burial chamber was of the 2B structure just like that of the burial chamber walls, while its thickness was 80cm with an eyebrow-type arch connected to it. Also, the ceiling exterior appears to have an arch structure, identical to the shape inside.