• Title/Summary/Keyword: 복합발전소

Search Result 177, Processing Time 0.034 seconds

A Study on the Demonstration of Yellow Plume Elimination System from Combined Cycle Power Plant Using Liquid Injection System (액상 직분사 시스템을 이용한 복합화력 황연제거 실증 연구)

  • Lee, Seung-Jae;Kim, Younghee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.317-324
    • /
    • 2020
  • Combined cycle power plants (CCPP) that use natural gas as fuel are easier to start and stop, and have lower pollutant emissions, so their share of domestic power generation facilities is steadily increasing. However, CCPP have a high concentration of nitrogen dioxide (NO2) emission in the initial start-up and low-load operation region, which causes yellow plume and civil complaints. As a control technology, the yellow plume reduction system was developed and operated from the mid-2000s. However, this technology was unable to control the phenomenon due to insufficient preheating of the vaporization system for 10 to 20 minutes of the initial start-up. In this study, CFD analysis and demonstration tests were performed to derive a control technology by injecting a reducing agent directly into the gas turbine exhaust duct. CFD analysis was performed by classifying into 5 cases according to the exhaust gas condition. The RMS values of all cases were less than 15%, showing a good mixing. Based on this, the installation and testing of the demonstration facilities facilitated complete control of the yellow plume phenomenon in the initial start-up.

Thermal Performance Analysis of Combined Power Plant Using Coal Gas - Development of the Steady-state Model - (석탄가스를 사용하는 복합발전 플랜트의 열성능 해석 -정상상태 성능해석 모델 개발-)

  • 김종진;박명호;안달홍;김남호;송규소;김종영
    • Journal of Energy Engineering
    • /
    • v.5 no.1
    • /
    • pp.8-18
    • /
    • 1996
  • As a part of comprehensive IGCC process simulation, the thermal performance analysis was performed for coal gas firing combined power plant. The combined cycle analyzed consisted of il Texaco gasifier and a low temperature gas cleanup system for the gasification block and a GE 7FA gas turbine, a HRSG and steam turbine for the power block. A steady state simulator called ASPEN(Advanced System for Process Engineering) code was used to simulate IGCC processes. Composed IGCC configuration included air integration between ASU and gas turbine and steam integration between gasifier, gas clean up and steam turbine. The results showed 20% increase in terms of gas turbine power output(MWe) comparing with natural gas case based on same heat input. The results were compared with other study results which Bechtel Canada Inc. performed for Nova Scotia power plant in 1991 and the consistency was identified within two studies. As a result, the analysing method used in this study is verified as a sound tool for commercial IGCC process evaluation.

  • PDF

Analysis of the Mediated Effects for the Organization Factors in a Combined-Cycle Power Plant (복합화력발전소 경영진의 안전관심이 직원의 안전참여에 미치는 영향관계에서 조직요인의 매개효과 분석)

  • Choi, JaeWoo;Um, SungIn;Hong, InGi
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.3
    • /
    • pp.22-29
    • /
    • 2016
  • Organization characteristics and safety culture contains a wide variety of factors. It should be accessed in a variety of ways in order to improve such a safety culture. Thru by analyzing the safety culture factor of combined-cycle-power plants, it was found to be a positive role in the improvement and enhancement for the improving of safety training, communication and training participation level by structural equation modeling analysis as the management's interest is increased. As the safety training is emphasized, it would be help to improve work participation.

A Study on Ammonia Conversion rate of Thermal Decomposition & Catalytic reaction of Hydrazine (열분해 및 촉매반응에 의한 Hydrazine의 Ammonia 전환율 연구)

  • Jung, Hyun-Jun;Rhee, In-Hyaung;Kang, Sin-Young;Jang, Sae-Bin
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05a
    • /
    • pp.452-454
    • /
    • 2012
  • 본 논문에서는 열분해 및 촉매반응의 의한 Hydrazine의 Ammonia 전환율을 연구하였다. 원자력발전소 2차 계통은 물/증기 순환계통으로 기기 및 배관의 부식을 억제하고, 증기발생기(Steam Generator, SG)의 부식생성물 유입을 최소하기 위해 전휘발성처리법(All Volatile Treatment, AVT)을 적용하여 계통수의 pH를 약염기성으로 유지하고 있다. 또한 Hydrazine을 이용하여 계통수의 용존산소제거 및 환원성 분위기를 유지하고 있다. 현재 사용되는 AVT는 대부분 단일 아민(Ammine)으로 계통 전 영역에서 pHt를 약염기성으로 유지하기 어렵다. 따라서 복합 아민을 이용하여 단일 아민의 상호단점을 보완한 수처리법을 적용해야한다. 하지만 복합 아민을 적용할 경우 추가 아민 주입설비, 설치부지, 시설유지보수 및 관리가 요구되므로 기존 주입약품을 이용하여 아민을 공급할 수 있는 연구가 필요하다. 따라서 본 연구에서는 Hydrazine의 열분해 및 촉매반응을 이용한 Ammonia 전환율을 조사하였다.

  • PDF

Combination Investigation Method for Grounwater Development Around Shinbuk area in Kangwon-Do (강원도 신북지역의 지하수 개발을 위한 복합 탐사법의 이용)

  • 서백수;김영화;한춘호;신성렬
    • The Journal of Engineering Geology
    • /
    • v.10 no.1
    • /
    • pp.39-50
    • /
    • 2000
  • Because of numerous mountain region, agricultural affairs work can't be done without groundwater in Kangwon Do area. Especially to improve high mountain area vegetable quality and raise income offarmers, both of groundwater and hydrothermal system to keep adequate temperature in hot and coldseason have to be developed. Domestic groundwater was developed for the use of agricultural watersince 1960. Exact investigation and control of groundwater are greatly required in utilizing undergroundspace as subway, nuclear power plant, oil and hazardous waste storehouse. Groundwater contaminationowing to industrial irrigation, trash decomposition can have a serious effect on human health and rustof underground building. In this study, global prospecting system are applied to detect groundwater, using electrical, seismic and georadar prospecting method.

  • PDF

Development of Composite Geo-Material for Recycling Dredged Soil and Bottom Ash (준설토와 Bottom Ash 재활용을 위한 복합지반재료 개발)

  • Kim, Yun-Tae;Han, Woo-Jong;Jung, Du-Hwoe
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.11
    • /
    • pp.77-85
    • /
    • 2007
  • This paper investigates the mechanical characteristics of composite geo-material which was developed to reuse both dredged soils and bottom ash. The composite geo-material used in this experiment consists of dredged soil taken from the construction site of Busan New Port, cement, air foam and bottom ash. Bottom ash is a by-product generated at the Samcheonpo thermal power plant. Several series of laboratory tests were performed to investigate behavior characteristics of composite gee-material, in particular the reinforcing effect by mixing bottom ash. The experimental results of composite geo-material indicated that the stress-strain relationship and the unconfined compressive strength are strongly influenced by mixing conditions. Especially it was observed that the compressive strength of composite geo-material increased with an increase in bottom ash content due to reinforcing effect by the bottom ash. Compressive strength of composite geo-material increased with the increase in curing time. The 28-day strength of composite geo-material is $1.7{\sim}1.8$ times higher than the 7-day strength. The moist unit weight strongly depended on air-foam content as well as bottom ash content added to the composite goo-material. In composite geo-material, secant modulus ($E_{50}$) also increased as its compressive strength increased due to the inclusion of bottom ash.

Studies on the application of unit-inverter parallel operation to sea-water lift pump in power plant(I) (단위 인버터 병렬운전에 의한 발전소 해수펌프 적용(I))

  • 김수열;류홍우
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.285-289
    • /
    • 1997
  • 발전설비의 대형화로 인하여 소내소비 전력량이 점점 증가하고 있는 추세이며 대용량의 화력발전소라 하더라도 기저부하보다는 부하조정의 역할이 강해져 정격속도로 운전하던 팬, 펌프등을 필요 부하에 따라 회전수를 제어하여 전력절감을 꾀하여야 할 필요가 있다[1]. 이에 따라 생산기술개발 과제로 개발한 대용량 GTO 인버터 시스템을 서 인천복합화력발전소의 3상 6600V 1500KW 용량인 전동기 구동 해수펌프에 적용하기 위한 기술적 검토 내용과 계산된 전력 절감량을 제시하였다. 적용 시스템으로는 개발된 3상 660V 1MVA 단위 인버터를 병렬 운전시켜 2MVA의 용량으로 하였으며 인버터의 입출력 단에 변압기를 설치하여 강압 및 승압 시켜 사용하였다.[2]

  • PDF

Technology Development for Cavitation Utilization of High viscosity Liquid Fuels (고점도 유체의 캐비테이션 활용 기술 개발)

  • Park, Jun-Sung;Chung, Seok-Woo;Lee, Seoung-Jong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.884-887
    • /
    • 2009
  • 최근에 경기악화에 따른 석유수요 감소로 우리가 주로 수입하는 두바이유는 배럴당 56 달러선이지만, 유가가 배럴당 100~120 달러로 오를 경우, 원유 대체 및 신규 에너지원 확보를 위해 Bitumen, Oil Shale, 중질잔사유 등 고점도 액상연료를 이용하기 위한 기술개발이 활발히 진행될 것으로 예상된다. 그리고 이에 따라 연소효율이 떨어지는 고점도 저급연료를 이용하여 연소효율을 극대화시키기 위해 계면활성제를 이용하여 화학적으로 유화시키는 기술들이 개발되어 있다. 본 연구에서는 고점도 유체에 대해 계면활성제를 이용하지 않고 캐비테이션 방식을 이용하여 고점도 유체를 에멀젼화 하는 기술을 연구하였다. 에멀젼화 기술은 저급연료유에 물을 혼합하여 안정적으로 장기간 유수분리가 일어나지 않으며, 복합연료로서 반응로에서 연소시킴으로써 연소율을 개선시킬수 있는 기술인데, 발전소의 보일러, 선박, 소각로 등에 적용할 수 있으며 중질잔사유를 사용하는 가스화 발전에도 본 기술이 사용될 수 있을 것으로 기대된다.

  • PDF

Short-term generation scheduling in virtual power plant with distribution resources (Virtual power plant를 구성하는 분산전원의 최적 운영)

  • Eum, Young-Chul;Bae, In-Su;Kim, Jin-O;Jo, Jong-Man
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.194-195
    • /
    • 2006
  • 미래의 전력 시스템은 환경과 기술적인 이유로 인해 더욱더 많은 분산전원을 이용하게 될 것이다. 분산전원은 서로 다른 특징을 가지고 있고 또한 배전계통에서 기존의 계통운영과는 다른 형태로 운전될 것이다. 이런 관점에서 다수의 분산전원을 모아 하나의 가상의 발전소로 운영하는 개념이 등장하게 되었는데, 이를 Virtual Power Plant(VPP)라고 한다. VPP는 매니지먼트 시스템이 관리하는 여러 클러스터들로 이루어져 있으며 이들 클러스터들은 각각 여러 종류의 분산전원으로 구성되어 있다. 본 논문에서는 클러스터를 이루는 분산전원을 어떻게 운영하는 것이 최적의 경제적 효율을 지닐 수 있을 지에 대해 논의하게 될 것이다. 디젤 발전기의 출력의 경우 그 소유자에 의해 제어가 가능하지만, 태양광 발전 시스템의 경우 기상 상태에 따라 그 출력이 결정된다. 따라서 이러한 각각의 특성을 고려하여 본 논문에서는 디젤, CHP(Combined Heat and Power), 보일러, 태양광발전으로 구성된 복합 시스템에서 각 시간별로 수용가의 전력 및 열 수요와 분산전원의 에너지 생산을 비교하여 VPP 최적 운영 계획을 구성하였다.

  • PDF

재료 및 파괴부문

  • 김영진
    • Journal of the KSME
    • /
    • v.43 no.8
    • /
    • pp.32-43
    • /
    • 2003
  • 2002년도 재료 및 파괴부문의 연구는 예년에 비해 더욱 활성화되었다. 부문 학술대회에서 효율적인 학술토의 및 아이디어 교환을 위해 기획 세션을 구성하여 대회를 운영하였으며, 기획 세션의 종료 및 세션 조직위원으로 활동한 회원은 다음과 가다. CAE/피로설계(이영신, MSC Korea), 신소재 및 복합재료(한경섭, 포항공대), 접합부의 강도평가(남기우, 부경대), 신뢰성 평가(진태은, 한전기술), 구조물의 손상평가(신병천, KIMM), NDT 기법 응용(윤동진, 표준연), 전자패키징 신뢰서(이순복, KAIST), 계산역학(박재학, 충북대), 발전소요소 진단 및 평가(박윤원, 원자력안전기술원), RBI-FFS-IT(최지붕, 성균관대), NT 분야(박준협, 동명정보대), 에너지 및 화력발전분야(하정수, 전력연구원)이다. 본 연감의 내용도 위에 언급한 기획 세션 주제별로 나누어 활동 사항을 요약하였다. 일부 논문은 분야가 중복되기도 하지만 본 연감에서는 주요 세션에서만 언급하였으며, 지면 관계상 많은 우수한 연구 활동에 대해 적절히 언급되지 못한 면도 있음을 발혀둔다.

  • PDF