• Title/Summary/Keyword: 보존형

Search Result 934, Processing Time 0.039 seconds

A Study on the Retentive Force of Stud Attachments for Implant Overdenture (임플란트 피개의치를 위한 개별유지형 어태치먼트의 유지력에 관한 연구)

  • Song, Eun-Ju;Bae, Eun-Bin;Choi, Jae-Won;Bae, Ji-Hyeon;Kim, Ji-Young;Lee, So-Hyoun
    • Journal of dental hygiene science
    • /
    • v.16 no.1
    • /
    • pp.93-100
    • /
    • 2016
  • The purpose of this study was to compare the changes of retentive force in different stud attachment systems for implant retained overdenture. Two commercially available attachments with different retentive forces were investigated: Kerator (pink, blue, red) and O-ring (orange, red). Two implant fixtures were vertically embedded in base mountings. Five pairs of each attachment were evaluated. A universal testing machine was used to evaluate the retentive force of two attachments during wear simulation. Surface characteristics of each attachment system were evaluated with scanning electron microscopy. Five pairs of each attachment were evaluated. Kerator pink showed the highest initial retention. After 2,500 cycles of wear-simulation, Kerator pink noted the largest decrease in retention. According to results of surface analysis, Worn surfaces were obtained in matrices and patrices. Heavy wears were observed in matrices. After 2 year-wear simulation, most attachments exhibited retention loss. Attachments using different kind of material exhibited dissimilar surface alterations.

A Study of Total Delay Occurrence Depending on Merging Speed from Acceleration Lane (도로연결 시설 진출차량의 합류속도에 따른 본선 유발 총 지체 분석)

  • Lee, Junhyung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.19 no.2
    • /
    • pp.62-73
    • /
    • 2020
  • Access management is aimed at preserving the road's high intercity mobility. In urbanized areas, immoderate acceleration lane-length requirements restrict the accessibility of land. Therefore, there are many opinions to revise the minimum acceleration lane-length requirement. For this purpose, it is important to diagnose the effects of slow vehicles on the mainline. This study analyzed a single merging vehicle's total delay occurrence depending on the mainline traffic flow rate and merging speed. A linear relationship was observed between the mainline traffic flow rate and total delay. As a merging speed increases gradually from 40km/h to 100km/h in 20km/h intervals, the total delay decreases by 5.0, 1.6, and 5.1 times, respectively. This shows that the ideal condition with the total delay is less than 0.5 vehicle·sec when there is no speed difference between the mainline and merging vehicle. On the other hand, given the one-second response time of drivers, the total delay occurrence was slightly low when the speed difference between the mainline and merging vehicle was less than 20km/h.

Restoration of an Edentulous Patient with CAD/CAM Guided Implant Surgery ($NobelGuide^{TM}$) and Immediate Loading: Case Report (무치악 환자에서 CAD/CAM을 이용한 임플란트 식립($NobelGuide^{TM}$) 및 즉시하중 증례)

  • Ko, Kyoung-Ho;Lim, Kwang-Gil;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.233-245
    • /
    • 2011
  • With the use of computed tomography (CT), computer-aided design/computer-assisted machining (CAD/CAM) technology and internet, the implant dentistry has been evolved. The surgical templates made by CAD/CAM technology and precise installation of implants, permit restorations to be inserted immediately after implants have been placed. The advantages of CAD/CAM guided implant procedures are flapless, minimally invasive surgery and shorter surgery time. With this technique, less postoperative morbidity and delivery of prosthesis for immediate function would be possible. A patient with an edentulous maxilla and mandible received 7 implants in mandible using CAD/CAM surgical templates. Prefabricated provisional fixed prostheses were connected immediately after implant installation. Provisional prostheses were evaluated for aesthetics and function during 6 months. Definitive prostheses were fabricated. At 6 months recall appointment, patient's occlusion was slightly changed. To prevent additional adverse effect, regular check-up and occlusal adjustment would be needed.

The Effect of Cone Protective Net and the Morphological Variation of Cone and Seed of Korea Rare Endemic Pinus pumila Regel (희귀수종 눈잣나무의 구과보호망 효과 및 구과와 종자의 형태적 변이)

  • Song, Jeong-Ho;Lim, Hyo-In;Jang, Kyung-Hwan;Kim, Du-Hyun;Son, Jang-Ick
    • Korean Journal of Plant Resources
    • /
    • v.25 no.4
    • /
    • pp.401-406
    • /
    • 2012
  • This study was conducted to investigate the effect of cone protective net and the variation of cone and seed characteristics of a unique and rare dwarf stone pine (Pinus pumila Regel) population in Mt. Seorak which is in the southern peripheral of South Korea. Iron protective net (50 mesh, 25 ${\times}$ 25 cm) was effective in reducing birds and rodents damage to conelet, thereby it was possible to safely collect seed genetic resources. Early July was observed to be the most appropriate season to cover conelet with Iron protective net. P. pumila have ovoid-triangle shaped, wingless seeds and indehiscent cones, seeds dissemination is mainly by the hoarding behavior of nutcrackers and rodents. Statistical analysis showed that there were significant differences among individuals within population, and the mean characteristics of the species were 35.3 mm, 25.6 mm, 1.38, 6.6 g and 39.3 ea in the cone length, cone width, cone index, cone weight and in number of seeds per cone, respectively. Coefficients of variations in seed weight and number of seeds per cone were relatively high (21.7%, 21.5%, respectively) compared to other traits. Based on the correlation analysis between cone characteristics and seed characteristics, the length of cone and seed showed a significant positive correlation with the seed size and the seed weight, but the width and thickness of seed showed a negative correlation with the number of seeds per cone.

Comparative analysis of various corrosive environmental conditions for NiTi rotary files (니켈티타늄 파일의 부식에 영향을 미치는 다양한 환경 조건 비교)

  • Yum, Ji-Wan;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.377-388
    • /
    • 2008
  • The aim of the present study is to compare the corrosion tendency using two kinds of NiTi files in the various environmental conditions through the visual examination and electrochemical analysis. ProTaper Universal S2, 21 mm (Dentsply Maillefer, Ballaigues, Switzerland) and Hero 642, 0.06 tapers, size 25, 21 mm (Micromega, Besancon, France) rotary instruments were tested. The instruments were randomly divided into eighteen groups (n = 5) by the immersion temperature, the type of solution, the brand of NiTi rotary instrument and the presence of mechanical loading. Each file was examined at various magnifications using Scanning Electron Microscope (JEOL, Akishima, Tokyo, Japan) equipped with energy dispersive X-ray microanalysis (EDX). EDX was used to determine the components of the endodontic file alloy in corroded and noncorroded areas. The corrosion resistance of unused and used NiTi files after repeated uses in the human teeth was evaluated electrochemically by potentiodynamic polarization test using a potentiostat (Applied Corrosion Monitoring, Cark-in-Cartmel, UK). Solution temperature and chloride ion concentration may affect on passivity of NiTi files. Under the conditions of this in vitro study, the corrosion resistance is slightly increased after clinical use.

STRESS DISTRIBUTION OF THREE NITI ROTARY FILES UNDER BENDING AND TORSIONAL CONDITIONS USING 3-DIMENSIONAL FINITE ELEMENT ANALYSIS (세가지 니켈 티타늄 파일의 휨과 비틀림 조건에서의 응력 분포에 관한 3차원 유한요소 연구)

  • Kim, Tae-Oh;Lee, Chan-Joo;Kim, Byung-Min;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.323-331
    • /
    • 2008
  • Flexibility and fracture properties determine the performance of NiTi rotary instruments. The purpose of this study was to evaluate how geometrical differences between three NiTi instruments affect the deformation and stress distributions under bending and torsional conditions using finite element analysis. Three NiTi files (ProFile .06 / #30, F3 of ProTaper and ProTaper Universal) were scanned using a Micro-CT. The obtained structural geometries were meshed with linear, eight-noded hexahedral elements. The mechanical behavior (deformation and von Mises equivalent stress) of the three endodontic instruments were analyzed under four bending and rotational conditions using ABAQUS finite element analysis software. The nonlinear mechanical behavior of the NiTi was taken into account. The U-shaped cross sectional geometry of ProFile showed the highest flexibility of the three file models. The ProTaper, which has a convex triangular cross-section, was the most stiff file model. For the same deflection, the ProTaper required more force to reach the same deflection as the other models, and needed more torque than other models for the same amount of rotation. The highest von Mises stress value was found at the groove area in the cross-section of the ProTaper Universal. Under torsion, all files showed highest stresses at their groove area. The ProFile showed highest von Mises stress value under the same torsional moment while the ProTaper Universal showed the highest value under same rotational angle.

THE EFFECT OF FLOWABLE RESIN LINING ON THE MARGINAL MICROLEAKAGE OF CONDENSABLE RESIN RESTORATION (응축형 복합레진 수복시 유동성 레진 이장이 변연부 미세누출에 미치는 영향)

  • 문주훈;고근호
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.1
    • /
    • pp.16-22
    • /
    • 2001
  • The purpose of this study was to evaluate the marginal microleakage of condensable composite resin restorations according to flowable resin lining of internal cavity wall. The eighty extracted human molar teeth without caries and/or restorations are used The experimental teeth were randomly assigned into four groups of ten teeth each. Eighty caries-free extracted human molars were used in this study. The conventional class II cavities (box-shaped on mesial and distal surface, faciolingual width : 3mm, gingival wall depth : 1.5mm) were prepared 1mm below cementoenamel junction with a # 701 carbide bur. The teeth were divided into four groups, and then each group were subdivided into A & B group according to flowable resin & compomer lining ; Group 1-A : Tetric Ceram filling, Group 1-B : Tetric Flow lining and Tetric Ceram filling, Group 2-A Ariston pHc filling, Group 2-B : Tetric Flow lining and Ariston pHc filing, Group 3-A SureFil filling, Group 3-B : Dyract Flow lining and SureFil filling, Group 4-A : Pyramid filling, Group 4-B : Aeliteflo lining and Pyramid filling. To simulate as closely as possible the clinical situation during retoration placement, a "restoration template" was fabricated, and the condensable resin was filled using a three-sited light-curing incremental technique. All the materials used were applied according to the manufacturers' instructions. The specimens were stored in the 100% humidity for 7 days prior to thermocycling (100 thermal cycles of 5~55$^{\circ}C$ water with a 30-second dwell time) The specimens were immersed in 2% metyleneblue dye for 24 hours, and then embedded in transparent acrylic resin and sectioned mesiodistally with diamond wheel saw. The degree of marginal leakage was scored under stereomicroscope ($\times$20) and the data were analyzed by Kruskal-Wallis test and Wilcoxon signed ranks test. The results were as follows : 1. In the gingival margins of all the group, microleakage of subgroup B was less than subgroup A. 2. In the group 1, 2, 4, there was significant differences between subgroup A and B (p<0.05), but in the group 3, there was not significant different between group 3-A (SureFil) and group 3-B (Dyract flow/SureFil) (p>0.05). 3. In the subgroup A and B, there was significant different between all group except group 4 of subgroup A. From the results above, it was suggested that the cavity lining of flowable resin and flowable compomer in condensable resin restoration decrease microleakage at gingival margin, and does improve their ability to seal the gingival margin of class II preparation.

  • PDF

The Effects of Various Light Intensity on the Polymerization of Resin Composites (광조사 강도의 변화에 따른 광중합 복합레진의 중합반응에 관한 연구)

  • Jun-Gyu Park;Byeong-Hoon Cho;In-Bog Lee;Hyuck-Choon Kwon;Chung-Moon Um
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.1
    • /
    • pp.86-94
    • /
    • 2001
  • 기존의 광중합기는 높은 광강도를 제공함으로써 광중합 복합레진을 최대한 단축된 시간내의 중합을 목표로 하였다. 이러한 높은 광강도는 복합레진의 중합깊이, 중합률면에서는 우수하나 중합 반응속도가 빠름으로 인해 중합시 응력 발생이 높아진다는 일련의 보고가 있다. 최근에는 광중합 속도를 늦춤으로써 변연적합도 및 중합시 응력 발생을 낮추는 새로운 중합방법들이 제시되고 있다. 이에 본 실험에서는 광조사 강도의 변화가 광중합 복합레진의 중합반응 과정에 미치는 영향 및 중합된 복합레진의 중합률에 대한 영향을 분석하고자 하였다. 5개의 혼합형 광중합 복합레진 (Z-100, Spectrum, Z-250, Clearfil AP-X, P-60)을 사용하였으며 중합시 적용된 광조사 강도에 따라 6개의 실험군으로 정의하였다. 실험군과 이에 따른 광조사 방법은 다음과 같다. 1군은 110mW/$\textrm{cm}^2$로 40초 중합, 2군 210mW/$\textrm{cm}^2$로 40초 중합, 3군 410mW/$\textrm{cm}^2$로 40초 중합, 4군 620mW/$\textrm{cm}^2$로 40초 중합, 5군 110mW/$\textrm{cm}^2$로 10초 중합 후 1분 뒤 620mW/$\textrm{cm}^2$로 30초 중합, 6군 210mW/$\textrm{cm}^2$로 10초 중합 후 1분 뒤 410mW/$\textrm{cm}^2$로 30초 중합하였다. 광중합시 중합 반응 양상에 관한 분석은 시차주사 열계량기를 이용하여 37$^{\circ}C$ 항온상태에서 10분간의 열흐름곡선을 기록하였다. 기록된 열흐름곡선에서 중합 반응시 나타나는 중합열 및 최대 중합열에 이르는 시간을 기록하여 중합반응 속도를 측정하였다. 중합된 복합레진의 중합률은 Fourier Transform Infrared Spectrometer(FTIR)를 이용하였으며 2mm 두께의 복합레진 하방에서의 중합률을 측정하였다. 측정된 결과는 ANOVA 및 Student-Newman-Keuls 방법을 이용하여 유의성을 검증하였다. 실험결과 다음과 같은 결론을 얻었다. 1. 광중합 복합레진 중합시 광조사 강도가 증가할수록 중합열은 증가하였으나 통계적 유의성은 보이지 않았다 (p>0.05). 2. 최대 중합열에 이르는 시간은 광조사 강도가 증가할수록 단축되었다. 이단계 중합방법을 사용한 경우 중합반응 속도를 감소시킬 수 있음을 보였다. 3. 광조사 강도가 증가할수록 중합률은 증가하였다. 이단계 중합방법을 사용한 경우 연속적인 고광강도를 사용한 경우와 유사한 높은 중합률을 보였다. 4. 중합률면에서 광중합복합레진의 중합시 400mW/$\textrm{cm}^2$ 이상의 광강도가 필요한 것으로 나타났다.

  • PDF

The effect of solvent evaporation of dentin adhesive on bonding efficacy (상아질 접착제의 용매 증발이 접착 효율에 미치는 영향)

  • Cho, Min-Woo;Kim, Ji-Yeon;Kim, Duck-Su;Choi, Kyoung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.5
    • /
    • pp.321-334
    • /
    • 2010
  • Objectives: The purpose of this study is to evaluate bonding efficacy by means of measuring the effect of remained solvent on Degree of conversion(DC) and ${\mu}TBS$ and FE-SEM examination. Materials and Methods: Two 2-step total etching adhesives and two single-step self etching adhesives were used in this study. First, volume weight loss of 4 dentin adhesives were measured using weighting machine in process of time in normal conditions and calculate degree of evaporation (DE). Reaction/reference intensity ratio were measured using micro-Raman spectroscopy and calculate DC according to DE. Then 2 experimental groups were prepared according to air-drying methods (under, over) and control group was prepared to manufacturer's instruction. Total 12 groups were evaluated by means of micro tensile bond strength and FE-SEM examination. Results: Degree of evaporation (DE) was increased as time elapsed but different features were observed according to the kind of solvents. Acetone based adhesive showed higher DE than ethanol and butanol based adhesive. Degree of conversion (DC) was increased according to DE except for $S^3$ bond. In ${\mu}TBS$ evaluation, bond strength was increased by additional air-drying. Large gaps and droplets were observed in acetone based adhesives by FE-SEM pictures. Conclusions: Additional air-drying is recommended for single-step self etching adhesive but careful consideration is required for 2-step total etching adhesive because of oxygen inhibition layer. Evaporation method is carefully chose and applied according to the solvent type.

Histological evaluation of direct pulp capping with DSP-derived synthetic peptide in beagle dog (비글견에서 DSP 유도 합성 펩타이드를 이용한 직접 치수 복조술에 대한 조직학적 연구)

  • Kim, Jae-Hoon;Hong, Jun-Bae;Lim, Bum-Soon;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.2
    • /
    • pp.120-129
    • /
    • 2009
  • The purpose of this study was to investigate the pulpal response to direct pulp capping with dentin sialoprotein (DSP) -derived synthetic peptide in teeth of dogs, and to compare its efficacy to capping substances $Ca(OH)_2$ and white mineral trioxide aggregate (WMTA). A total of 72 teeth of 6 healthy male beagle dogs were used. The mechanically exposed pulps were capped with one of the following: (1) DSP-derived synthetic peptide (PEP group): (2) $Ca(OH)_2$ (CH group): (3) a mixture paste of peptide and $Ca(OH)_2$ (PEP+CH group): or (4) white MTA (WMTA group). The access cavity was restored with a reinforced glass ionomer cement. Two dogs were sacrificed at each pre-determined intervals (2 weeks, 1 month, and 3 months). After the specimens were prepared for standard histological processing, sections were stained with hematoxylin and eosin. Under a light microscope, inflammatory response and hard tissue formation were evaluated in a blind manner by 2 observers. In the PEP group, only 3 of 17 specimens showed hard tissue formation, indication that the DSP-derived synthetic peptide did not induce proper healing of the pulp. Compared with the CH group, the PEP group demonstrated an increased inflammatory response and poor hard tissue formation. The CH and WMTA groups showed similar results for direct pulp capping in mechanically exposed teeth of dogs.