• 제목/요약/키워드: 보정 방법

Search Result 3,703, Processing Time 0.046 seconds

Evaluation of Radioactivity Concentration According to Radioactivity Uptake on Image Acquisition of PET/CT 2D and 3D (PET/CT 2D와 3D 영상 획득에서 방사능 집적에 따른 방사능 농도의 평가)

  • Park, Sun-Myung;Hong, Gun-Chul;Lee, Hyuk;Kim, Ki;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.111-114
    • /
    • 2010
  • Purpose: There has been recent interest in the radioactivity uptake and image acquisition of radioactivity concentration. The degree of uptake is strongly affected by many factors containing $^{18}F$-FDG injection volume, tumor size and the density of blood glucose. Therefore, we investigated how radioactivity uptake in target influences 2D or 3D image analysis and elucidate radioactivity concentration that mediate this effect. This study will show the relationship between the radioactivity uptake and 2D,3D image acquisition on radioactivity concentration. Materials and Methods: We got image with 2D and 3D using 1994 NEMA PET phantom and GE Discovery(GE, U.S.A) STe 16 PET/CT setting the ratio of background and hot sphere's radioactivity concentration as being a standard of 1:2, 1:4, 1:8, 1:10, 1:20, and 1:30 respectively. And we set 10 minutes for CT attenuation correction and acquisition time. For the reconstruction method, we applied iteration method with twice of the iterative and twenty times subset to both 2D and 3D respectively. For analyzing the images, We set the same ROI at the center of hot sphere and the background radioactivity. We measured the radioactivity count of each part of hot sphere and background, and it was comparative analyzed. Results: The ratio of hot sphere's radioactivity density and the background radioactivity with setting ROI was 1:1.93, 1:3.86, 1:7.79, 1:8.04, 1:18.72, and 1:26.90 in 2D, and 1:1.95, 1:3.71, 1:7.10, 1:7.49, 1:15.10, and 1:23.24 in 3D. The differences of percentage were 3.50%, 3.47%, 8.12%, 8.02%, 10.58%, and 11.06% in 2D, the minimum differentiation was 3.47%, and the maximum one was 11.06%. In 3D, the difference of percentage was 3.66%, 4.80%, 8.38%, 23.92%, 23.86%, and 22.69%. Conclusion: The difference of accumulated concentrations is significantly increased following enhancement of radioactivity concentration. The change of radioactivity density in 2D image is affected by less than 3D. For those reasons, when patient is examined as follow up scan with changing the acquisition mode, scan should be conducted considering those things may affect to the quantitative analysis result and take into account these differences at reading.

  • PDF

The characteristics on dose distribution of a large field (넓은 광자선 조사면($40{\times}40cm^2$ 이상)의 선량분포 특성)

  • Lee Sang Rok;Jeong Deok Yang;Lee Byoung Koo;Kwon Young Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.19-27
    • /
    • 2003
  • I. Purpose In special cases of Total Body Irradiation(TBI), Half Body Irradiation(HBI), Non-Hodgkin's lymphoma, E-Wing's sarcoma, lymphosarcoma and neuroblastoma a large field can be used clinically. The dose distribution of a large field can use the measurement result which gets from dose distribution of a small field (standard SSD 100cm, size of field under $40{\times}40cm2$) in the substitution which always measures in practice and it will be able to calibrate. With only the method of simple calculation, it is difficult to know the dose and its uniformity of actual body region by various factor of scatter radiation. II. Method & Materials In this study, using Multidata Water Phantom from standard SSD 100cm according to the size change of field, it measures the basic parameter (PDD,TMR,Output,Sc,Sp) From SSD 180cm (phantom is to the bottom vertically) according to increasing of a field, it measures a basic parameter. From SSD 350cm (phantom is to the surface of a wall, using small water phantom. which includes mylar capable of horizontal beam's measurement) it measured with the same method and compared with each other. III. Results & Conclusion In comparison with the standard dose data, parameter which measures between SSD 180cm and 350cm, it turned out there was little difference. The error range is not up to extent of the experimental error. In order to get the accurate data, it dose measures from anthropomorphous phantom or for this objective the dose measurement which is the possibility of getting the absolute value which uses the unlimited phantom that is devised especially is demanded. Additionally, it needs to consider ionization chamber use of small volume and stem effect of cable by a large field.

  • PDF

Role of Radiation Therapy for Stage III Thymoma (제 3기 흉선종에서 방사선치료의 역할)

  • Chun, Ha-Chung;Lee, Myung-Za
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.16-20
    • /
    • 2001
  • Purpose : To evaluate the effectiveness and tolerance of the postoperative radiation therapy for patients with Stage III thymoma and to define the optimal radiotherapeutic regimen Materials and Methods : We retrospectively analyzed the records of 24 patients with Stage III thymoma who were referred for postoperative radiation therapy in our institution from June, 1987 to May, 1999. Surgical therapy consisted of total resection in one patient, subtotal resection in seventeen, and biopsy alone in six patients. Age of the patients was ranged from 20 to 62 years with mean age of 47 years. Male to female ratio was 14 to 10. Radiation therapy was delivered with linear accelerator producing either 6 MeV or 10 MeV photons. The irradiated volume included anterior mediastinum and known residual disease. The supraclavicular fossae were not irradiated. The delivered total dose was ranged from 30 to 56 Gy. One patient received 30 Gy and eighteen patients received minimum of 50 Gy. Follow up period was ranged from 12 months to 8 years with median follow up of 40 months. Results : The overall local control rate for entire group of patients was $67\%$ at 5 years. The cumulative local failure rates at one, three and five year were $18\%,\;28\%\;and\;33\%$, respectively. In patients treated with subtotal resection and biopsy alone, local control rate was $76\%\;and\;33\%$, respectively. The actuarial observed survival rate at 5 years was $57\%$, and actuarial adjusted survival at 5 years was $72\%$. The difference between 5 year survival rates for patients treated with subtotal resection and biopsy alone was not statistically significant $(62\%\;vs\;30\%)$. Conclusion : We might conclude that postoperative radiation therapy was safe and effective treatment for patients with Stage III thymoma. Postoperative radiation therapy is recommended in cases where tumor margin is close or incomplete resection is accomplished.

  • PDF

Measurement and Quality Control of MIROS Wave Radar Data at Dokdo (독도 MIROS Wave Radar를 이용한 파랑관측 및 품질관리)

  • Jun, Hyunjung;Min, Yongchim;Jeong, Jin-Yong;Do, Kideok
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.32 no.2
    • /
    • pp.135-145
    • /
    • 2020
  • Wave observation is widely used to direct observation method for observing the water surface elevation using wave buoy or pressure gauge and remote-sensing wave observation method. The wave buoy and pressure gauge can produce high-quality wave data but have disadvantages of the high risk of damage and loss of the instrument, and high maintenance cost in the offshore area. On the other hand, remote observation method such as radar is easy to maintain by installing the equipment on the land, but the accuracy is somewhat lower than the direct observation method. This study investigates the data quality of MIROS Wave and Current Radar (MWR) installed at Dokdo and improve the data quality of remote wave observation data using the wave buoy (CWB) observation data operated by the Korea Meteorological Administration. We applied and developed the three types of wave data quality control; 1) the combined use (Optimal Filter) of the filter designed by MIROS (Reduce Noise Frequency, Phillips Check, Energy Level Check), 2) Spike Test Algorithm (Spike Test) developed by OOI (Ocean Observatories Initiative) and 3) a new filter (H-Ts QC) using the significant wave height-period relationship. As a result, the wave observation data of MWR using three quality control have some reliability about the significant wave height. On the other hand, there are still some errors in the significant wave period, so improvements are required. Also, since the wave observation data of MWR is different somewhat from the CWB data in high waves of over 3 m, further research such as collection and analysis of long-term remote wave observation data and filter development is necessary.

The study of quantitative analytical method for pH and moisture of Hanji record paper using non-destructive FT-NIR spectroscopy (비파괴 분석 방법인 푸리에 변환 근적외선 분광 분석을 이용한 한지 기록물의 산성도 및 함수율 정량 분석 연구)

  • Shin, Yong-Min;Park, Soung-Be;Lee, Chang-Yong;Kim, Chan-Bong;Lee, Seong-Uk;Cho, Won-Bo;Kim, Hyo-Jin
    • Analytical Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.121-126
    • /
    • 2012
  • It is essential to evaluate the quality of Hanji record paper without damaging the record paper by previous destructive methods. The samples were Hanji record paper produced in the 1900s. Near-infrared (NIR) spectrometer was used as a non destructive method for evaluating the quality of record papers. Fourier transform (FT) spectrometer was used with 12,500 to 4,000 $cm^{-1}$ wavenumber range for quantitative analysis and it has high accuracy and good signal-to-noise ratio. The acidity and moisture content of Hanji record paper were measured by integrating sphere as diffuse reflectance type. The acidity (pH) of chemical factors as a quality evaluated factor of Hanji was correlated to NIR spectrum. The NIR spectrum was pretreated to obtain the coefficients of optimum correlation. Multiplicative scatter correction (MSC) and First derivative of Savitzky-Golay were used as pretreated methods. The coefficients of optimum correlation were calculated by PLSR (partial least square regression). The correlation coefficients ($R^2$) of acidity had 0.92 on NIR spectra without pretreatment. Also the standard error of prediction (SEP) of pH was 0.24. And then the NIR spectra with pretreatment would have better correlation coefficient ($R^2$ = 0.98) and 0.19 as SEP on pH. For moisture contents, the linearity correlation without pretreatment was higher than the case with pretreatment (MSC, $1^{st}$ derivative). As the best result, the $R^2$ was 0.99 and SEP was 0.45. This indicates that it is highly proper to evaluate the quality of Hanji record papers speedily with integrated sphere and FT NIR analyzer as a non-destructive method.

The Effectiveness of Sympathetic Skin Response Studies for Patients with Primary Palmar Hyperhidrosis and Who Undergo Thoracic Sympathicotomy (일차성 수부 다한증에서 교감신경절제술 후 교감신경 피부반응 검사의 효용성)

  • Yoon, Jeong-Seob;Sim, Sung-Bo;Rhee, Won-Ihl
    • Journal of Chest Surgery
    • /
    • v.42 no.6
    • /
    • pp.738-743
    • /
    • 2009
  • Background: There is no standardized tool and parameter that can accurately assess the sympathetic function before and after performing sympathectomy in patients with primary palmar hyperhidrosis. We examined the effective-ness of the sympathetic skin response (SSR) study for documenting the change of sympathetic denervation before and after performing selective thoracic sympathicotomy. Material and Method: We prospectively investigated the SSR from 12 healthy subjects who were diagnosed with primary hyperhidrosis. Each SSR was recorded on the right palm or sole with electrical stimuli applied to the skin at the left wrist and foot and vice versa for the controlateral side. This test was performed before, 2 weeks and 1 year after selective thoracic sympathicotomy. The data was corrected for the onset latency and the amplitude of the SSR (n=24). Result: The mean age of the 12 patients was $24.6{\pm}0.4$ years (range: 19~36) and the gender ratio was 1 : 0.7. The mean values of the preoperative, postoperative 2 weeks and postoperative 1 year onset latency and amplitude of the palmar side (n=24) were $1.46{\pm}0.24$ msec and $6,043{\pm}2,339{\mu}V$, $1.63{\pm}0.42$ msec and $823{\pm}638{\mu}V$, and $1.44{\pm}0.39$ msec and $2,412{\pm}1,546{\mu}V$, respectively. The mean values of the plantar side (n=38) were $1.83{\pm}0.42$ msec and $2,816{\pm}1,694{\mu}V$, $2.16{\pm}0.39$ msec and $1,445{\pm}1,281{\mu}V$ and $1.95{\pm}0.25$ msec and $1,622{\pm}865{\mu}V$, respectively. Among the documented parameters, only the palmar amplitude (p=0.002) showed statistical significance in recording the change of the sympathetic system within the same individual for the pre and postoperative period. Conclusion: The SSR amplitude ratio may be a useful parameter for documenting the efficacy of sympathetic denervation after selective sympathicotomy.

Performance Characteristics of MicroPET R4 Scanner for Small Animal Imaging (소동물 영상을 위한 MicroPET R4스캐너의 특성평가)

  • Lee, Byeong-Il;Lee, Jae-Sung;Kim, Jin-Su;Lee, Dong-Soo;Choi, Chang-Un;Lim, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.49-56
    • /
    • 2005
  • Purpose: Dedicated animal PET is useful equipment for the study of new PET tracer. recently, microPET R4 was installed in the Korea institute of radiology and medical science. In this study, we measured the characteristics of scanner. Materials and methods: Resolution was measured using a line source (F-18:65 ${\mu}Ci$, inner diameter: 0.5 mm). The line source was put in the axial direction and was moved from the center of field of view to outside with 1 mm interval. PET images were reconstructed using a filtered back-protection and ordered subset expectation maximization. line source (16.5 ${\mu}Ci$, 78 mm) was put on the tenter of axial direction to measure the sensitivity when the deadtime was under 1%. Images were acquired during 4 minutes respectively from center to 39 mm outward. Delayed count was subtracted from total count and then decay was corrected for the calculation of sensitivity. Noise equivalent count ratio and scatter fraction were calculated using cylindrical phantom. Results: Spatial resolution of reconstructed image using filtered back-projection was 1.86 mm(radial), 1.95 mm(tangential), 1.95 mm(axial) in the tenter of field of view, and 2.54 mm, 2.8 mm, 1.61 mm in 2 cm away from the center respectively. Sensitivity was 2.36% at the center of transaxial field of view. Scatter fraction was 20%. Maximal noise equivalent count ratio was 66.4 kcps at 242 kBq/mL. Small animal images were acquired for confirmation of performance. Conclusion: Performance characteristics of microPET R4 were similar with reported value. So this will be a useful tool for small animal imaging.

Performance Prediction for an Adaptive Optics System Using Two Analysis Methods: Statistical Analysis and Computational Simulation (통계분석 및 전산모사 기법을 이용한 적응광학 시스템 성능 예측)

  • Han, Seok Gi;Joo, Ji Yong;Lee, Jun Ho;Park, Sang Yeong;Kim, Young Soo;Jung, Yong Suk;Jung, Do Hwan;Huh, Joon;Lee, Kihun
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.4
    • /
    • pp.167-176
    • /
    • 2022
  • Adaptive optics (AO) systems compensate for atmospheric disturbance, especially phase distortion, by introducing counter-wavefront deformation calculated from real-time wavefront sensing or prediction. Because AO system implementations are time-consuming and costly, it is highly desirable to estimate the system's performance during the development of the AO system or its parts. Among several techniques, we mostly apply statistical analysis, computational simulation, and optical-bench tests. Statistical analysis estimates performance based on the sum of performance variances due to all design parameters, but ignores any correlation between them. Computational simulation models every part of an adaptive optics system, including atmospheric disturbance and a closed loop between wavefront sensor and deformable mirror, as close as possible to reality, but there are still some differences between simulation models and reality. The optical-bench test implements an almost identical AO system on an optical bench, to confirm the predictions of the previous methods. We are currently developing an AO system for a 1.6-m ground telescope using a deformable mirror that was recently developed in South Korea. This paper reports the results of the statistical analysis and computer simulation for the system's design and confirmation. For the analysis, we apply the Strehl ratio as the performance criterion, and the median seeing conditions at the Bohyun observatory in Korea. The statistical analysis predicts a Strehl ratio of 0.31. The simulation method similarly reports a slightly larger value of 0.32. During the study, the simulation method exhibits run-to-run variation due to the random nature of atmospheric disturbance, which converges when the simulation time is longer than 0.9 seconds, i.e., approximately 240 times the critical time constant of the applied atmospheric disturbance.

Sex- and age group-specific associations between intakes of dairy foods and pulses and bone health in Koreans aged 50 years and older: Based on 2008~2011 Korea National Health and Nutrition Examination Survey (50세 이상 한국인의 성·연령군별 우유류와 두류 섭취량과 골 건강과의 관련성 : 2008~2011 국민건강영양조사 자료를 이용하여)

  • Seo, Hyun-Bi;Choi, Young-Sun
    • Journal of Nutrition and Health
    • /
    • v.49 no.3
    • /
    • pp.165-178
    • /
    • 2016
  • Purpose: This study was performed to examine associations of intakes of milk and dairy products, pulses, and soy foods with bone health in Koreans aged 50 yr and older. Methods: A total of 3,201 men and 3,581 women aged 50 yr and older who participated in the 2008~2011 Korea National Health and Nutrition Examination Survey were grouped by sex and age groups of 50~64 yr and 65 yr and older. Subjects within each sex and age group were divided into three bone health groups: normal, osteopenia, and osteoporosis groups based on bone mineral density. Intakes of nutrients and foods derived from 24-hour recall data were compared among three bone health groups. Associations between intake frequencies of foods, including milk, yogurt, tofu, or soy milk, and osteoporosis risk were evaluated based on confounding risk factor-adjusted logistic regression. Results: Calcium intake was in the order of normal, osteopenia, and osteoporosis in men (p < 0.01) and women (p < 0.05) aged 50~64 yr as well as in men aged 65 yr and older (p < 0.001). In women aged 50~64 yr, intake of milk and dairy products was lower in the osteoporosis group (p < 0.01) as compared with the osteopenia group. Intake of pulses or tofu was not significantly different among bone health groups. Odds ratio (OR) for milk intake frequency (${\geq}2$ times/week) compared to intake frequency less than 1 time/month was 0.45 (95% CI 0.24~0.85, p for trend = 0.022) in men aged 65 yr and older. The OR for yogurt intake frequency (1 time/month~1 time/week) was 0.47 (95% CI 0.30~0.73, p for trend = 0.019) in women aged 50~64 yr. Intake frequency of tofu or soy milk was not associated with reduced risk of osteoporosis in all groups. Conclusion: Dairy food intake was significantly associated with bone health, and its effect was sex- and age group-specific, whereas soy food intake was not. Dietary intervention to prevent osteoporosis would be effective for women aged 50~64 yr old and for men aged 65 yr and older.

Evaluation of Combine IGRT using ExacTrac and CBCT In SBRT (정위적체부방사선치료시 ExacTrac과 CBCT를 이용한 Combine IGRT의 유용성 평가)

  • Ahn, Min Woo;Kang, Hyo Seok;Choi, Byoung Joon;Park, Sang Jun;Jung, Da Ee;Lee, Geon Ho;Lee, Doo Sang;Jeon, Myeong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.201-208
    • /
    • 2018
  • Purpose : The purpose of this study is to compare and analyze the set-up errors using the Combine IGRT with ExacTrac and CBCT phased in the treatment of Stereotatic Body Radiotherapy. Methods and materials : Patient who were treated Stereotatic Body Radiotherapy in the ulsan university hospital from May 2014 to november 2017 were classified as treatment area three brain, nine spine, three pelvis. First using ExacTrac Set-up error calibrated direction of Lateral(Lat), Longitudinal(Lng), Vertical(Vrt), Roll, Pitch, Yaw, after applied ExacTrac moving data in addition to use CBCT and set-up error calibrated direction of Lat, Lng, Vrt, Rotation(Rtn). Results : When using ExacTrac, the error in the brain region is Lat $0.18{\pm}0.25cm$, Lng $0.23{\pm}0.04cm$, Vrt $0.30{\pm}0.36cm$, Roll $0.36{\pm}0.21^{\circ}$, Pitch $1.72{\pm}0.62^{\circ}$, Yaw $1.80{\pm}1.21^{\circ}$, spine Lat $0.21{\pm}0.24cm$, Lng $0.27{\pm}0.36cm$, Vrt $0.26{\pm}0.42cm$, Roll $1.01{\pm}1.17^{\circ}$, Pitch $0.66{\pm}0.45^{\circ}$, Yaw $0.71{\pm}0.58^{\circ}$, pelvis Lat $0.20{\pm}0.16cm$, Lng $0.24{\pm}0.29cm$, Vrt $0.28{\pm}0.29cm$, Roll $0.83{\pm}0.21^{\circ}$, Pitch $0.57{\pm}0.45^{\circ}$, Yaw $0.52{\pm}0.27^{\circ}$ When CBCT is performed after the couch movement, the error in brain region is Lat $0.06{\pm}0.05cm$, Lng $0.07{\pm}0.06cm$, Vrt $0.00{\pm}0.00cm$, Rtn $0.0{\pm}0.0^{\circ}$, spine Lat $0.06{\pm}0.04cm$, Lng $0.16{\pm}0.30cm$, Vrt $0.08{\pm}0.08cm$, Rtn $0.00{\pm}0.00^{\circ}$, pelvis Lat $0.06{\pm}0.07cm$, Lng $0.04{\pm}0.05cm$, Vrt $0.06{\pm}0.04cm$, Rtn $0.0{\pm}0.0^{\circ}$. Conclusion : Combine IGRT with ExacTrac in addition to CBCT during Stereotatic Body Radiotherapy showed that it was possible to reduce the set-up error of patients compared to single ExacTrac. However, the application of Combine IGRT increases patient set-up verification time and absorption dose in the body for image acquisition. Therefore, depending on the patient's situation that using Combine IGRT to reduce the patient's set-up error can increase the radiation treatment effectiveness.

  • PDF