• Title/Summary/Keyword: 변형기관

Search Result 189, Processing Time 0.033 seconds

A Comparison of Static and Dynamic Deformation Modulus by Dynamic Plate Test (동평판 재하시험을 이용한 정적 및 동적 변형계수 비교)

  • 박용부;정형식
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.5
    • /
    • pp.335-342
    • /
    • 2003
  • The method of measuring ground deformation modulus, in situ-testing has the disadvantage where the exam number is limited because it needs counter weight and a lot of measurement times. Recently, it has supplemented this problem and the equipments by which measurement can be made quickly are developed and applied in field., That is Falling Weight Deflectometer(FWD), Light Drop Weight Tester(LDWT), Geogauge. Light Drop Weight Teste.(LDWT) is introduced firstly in the name of ‘a lightweight fall circuit tester for a railroad public corporation’ by KTX. Since KTX introduced LDWT, a number of research organizations have used LDWT to find out domestic standard for quality management of base ground. In this study we used ZFG 02 which was manufactured by Stendal in Germany and measured the dynamic deformation modulus in soil box and in-situ. And we analyzed the correlation of the dynamic deformation modulus with static deformation modulus based on plate test in the same ground.

Modified Extraluminal Prostheses Applied to the Canine Tracheal Collapse (변형제작한 기관외보철물을 이용한 기관허탈전 치료 1예)

  • 이충호;권오경;남치주
    • Journal of Veterinary Clinics
    • /
    • v.17 no.1
    • /
    • pp.266-269
    • /
    • 2000
  • Tracheal collapse at the thoracic inlet is described in a 4 year-old female yorkshire terrier. The initial presenting signs included coughing, dyspnea, cyanosis and collapse. Diagnosis was based upon the clinical signs, physical examination, plain radiography and fluoroscopy. The collapse was corrected by the aplication of a neumber of modified total ring prostheses (m-TRP) applied to the cervical trachea. Clinical complicatons were minimal and limited to mild, short-term coughing. The present study indicated that m-TRP were easy to apply to tracheal collapse and were able to decrese clinical signs. Therefore, m-TRP may be applied to tracheal collapse as new prostheses.

  • PDF

스피어 피싱 대응을 위한 엔드포인트 에이전트 시스템 모델에 관한 연구

  • Kim, Chang-Hong;Kim, Sang-Pil;Kim, Jong-Bae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.712-714
    • /
    • 2015
  • 기존의 정보보호시스템들은 이미 확보된 시그니처 또는 이전에 분석된 정보를 기반으로 악성코드에 대응하고 있기 때문에, 시그니처가 알려지지 않은 악성코드 또는 변형된 악성코드의 경우, 탐지 및 식별에 한계를 지니고 있다. 본 연구는 이와 같은 문제를 해결하기 위해, 무결성을 검증하는 화이트리스트 기반의 응용프로그램 실행제어, 매체제어, 레지스트리 보호, 중요 파일 변경 방지, 프로세스 접근 역접속 IP/포트 통제 등의 기술을 복합적으로 적용하여, 악성코드의 침입뿐만 아니라 운영체제 및 응용프로그램 취약점을 기반으로 한 익스플로잇 공격으로부터 단말 PC를 더욱 확실하게 보호할 수 있도록 한 엔드포인트 응용프로그램 실행 통제 방안을 제시하였다. 본 연구의 결과는 프로토타입 형태로 개발하여 실 환경에서 통합테스트를 하여 공공기관, 금융기관, 통신사 등 실제 환경에 적합한 기술 및 기능임을 확인하였다. 본 연구를 통해, 실행 전 응용프로그램 무결성 검증과 실행 후 응용프로그램 실행 흐름 통제를 복합적으로 사용하여 알려진 악성코드 시그니처 정보에 의존한 기존 정보 보호 시스템과는 달리 알려지지 않은 악성코드까지 원천적으로 차단할 수 있을 것으로 기대된다.

  • PDF

후두전적출술후 식도기능의 변화

  • 김세헌;홍원표;김충배;이원상;김광문
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1996.04a
    • /
    • pp.82-82
    • /
    • 1996
  • 후두전적출술은 상부 소화관의 연속성을 변형시킴으로써, 식도운동의 장애를 가져올 수 있으며, 술 후에 연하곤란을 호소하는 경우는 10% 가량 된다. 본 연구의 목적은 식도내압검사를 통하여, 후두전적출술이 상부식도괄약근의 휴지기와 최대 압력에 어떠한 변화를 주는가 및 술 후 인두와 상부식도괄약근의 조화성 여부와, 만일 상부식도괄약근의 기능에 변화가 생긴다면, 그 영향이 식도체부 및 하부식도괄약근의 운동성에 어떠한 영향을 주는지를 알아보기 위함이다. 식도내압검사는 8개의 내관을 가진 폴리에틸렌 도관으로, 후두전적출술을 받은 환자군 14명과 정상인 12명을 대상으로, stational pull-through 방법으로 시행하였다. 환자군에서 상부 식도괄약근은, 휴지기 압력, 최대 수축압력, 이완정도, 괄략운동의 조화성 및 괄약근의 길이 등이, 정상 대조군 보다 의미있게 감소되었다. 환자군에 있어서 식도체부의 운동성은 주로 근위부 식도체부에서, 수축력, 수축기간 및 연동파의 전파시간이 대조군에 비하여 의미있게 감소되었고, 연동운동시 동시 수축도 3례에서 관찰되었다. 하부 식도괄약근의 기능은 환자군과 대조군이 의미있는 차이를 보이지 않았다.

  • PDF

Submental Intubation for Maxillofacial Surgery -A Case Report - (구강악안면수술을 위한 악하 기관 삽관 -증례보고-)

  • Kim, Soung-Min;Kwon, Kwang-Jun
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.4 no.2 s.7
    • /
    • pp.96-99
    • /
    • 2004
  • 구강저를 통한 기관내 삽관은 1986년 Altemir에 의해 처음 소개된 바 있는데 그 후 1993년 Hoenig와 Braun 및 같은 해 Stoll 등에 의해서나, 또는 1996년 Prochno 등에 의해 계속 변형된 방법으로 문헌에서 기술되어 왔다. 이 방법은 치과 영역 특히 구강악안면외과의 외상수술시 이상적인 교합을 얻기 위해 임시 상하악간 고정(intermaxillary fixation)을 할 수 있고 중안모 골절(midface fracture)의 회복을 위한 비관 삽관의 불편함을 피할 수 있는 유리한 점이 있으며, 또한, 정복 및 고정술이 필요한 비골 골절(nasal bone fracture)에서나 두개기저골 골절(skull base fracture)에서 여러 감염 등 합병증을 피하기 위해 추천될 수 있다. 또한, 목 부위에 비심미적인 반흔을 만들게 되며 여러 합병증을 초래할 수 있는 기관절개술(tracheostomy)보다 유용할 수 있다. 본 증례보고에서는 교통사고로 두개기저부 골절을 동반한 심한 중안모 골절 환자에서 적용시킨 경우를 알아보고, 아울러 이러한 악하부 삽관의 장, 단점 및 시술 과정 등에 대해 고찰해보고자 한다.

  • PDF

Natural Aging Properties Analysis of HTPB Propellant (HTPB계 고체추진제의 자연노화 물성 분석)

  • Park, Jung-Ho;Ryu, Nam-Sun;Park, Jae-Beom;Jung, Gyoo-Dong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.1
    • /
    • pp.9-14
    • /
    • 2019
  • Hydroxy-terminated polybutadiene (HTPB) propellants of solid rocket motors age differently under different storage temperatures. The shelf life of a solid rocket motor depends on the aging ratio of the HTPB propellant; it can be estimated through the viscoelastic properties by an aging test. This study analyzed the initial and natural aging properties during long-term storage. The initial properties were obtained from characterization and accelerated test results. The test results were obtained by analyzing the strain on cylindrical grains when a thermal load was applied.

An anonymous asymmetric public key traitor tracing scheme (익명성을 보장하는 (비대칭) 공개키 공모자 추적)

  • 최은영;황정연;이동훈
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.04a
    • /
    • pp.311-313
    • /
    • 2003
  • 본 논문은 , 내용 은닉 서명[1]과 시간-잠금 퍼즐[2]을 이용해서 익명성을 보장하는 [3]의 공모자 추적 스킴이 사실상 익명성을 갖지 않는다는 것에 대해서 보인다. 그 다음, 신뢰 기관을 이용하여 익명성을 보장하는 두개의 스킴을 제시한다. 첫 번째 스킴은 게시판과 [4]의 영지식에서의 증명을 이용해서 [3]에 제시된 스킴을 변형시켜 익명성을 보장한다. 두 번째 스킴은 [5]의 비대칭 공모자 추적 스킴을 이용해서 익명성을 보장하는 공개키 공모자 추적 스킴을 제공한다.

  • PDF

Study on the Detection of In vivo and In vitro Hemocytic Pathway in Grasshopper, Euprepicnemis shirakii (메뚜기 체내와 체외에서 혈구생성 경로 추적에 관한 연구)

  • Chang, Byung-Soo
    • Applied Microscopy
    • /
    • v.33 no.2
    • /
    • pp.131-143
    • /
    • 2003
  • A Differentiating pathway of hemocytes in vitro and in vivo of grasshopper, Euprepocnemis shirakii was described using light and electron microscopes. In the interior of body, the stem cells of the hemopoietic organ differentiated into six types of cells respectively which are prohemoyte, plasmatocyte, granulocyte I, granulocyte II, spherulocyte and oenocytoid. The formation of these hemocytes was derived from the stem cells surrounded by a reticular cell. Hemopoietic tissue cultured in the insect media differentiated different hemocytes, but none of them underwent any mitotic division. Morphological features of the cultured cells in media were essentially the same as those of the hemocytes differentiated from the stem cells in vivo. These results were shown that each stem cell could differentiate into different types of hemocytes. It was confirmed that the stem cells possessed the pluripotent differentiation ability to directly each hemocyte, and that the once formed hemocytes in vivo and in vitro didn t undergo further transformation to other hemocytes. The maintenance of circulating hemocytes in grasshopper had been depended on the widely spreading hemopoietic organ situated in the upper surface of the dorsal alary muscle and located on the first to eighth segments.

A Study on the Structural Stability and Effectiveness of Rope Cutter for Ship's Propeller (선박추진기용 로프절단장치의 구조 안정성 및 효용성에 관한 연구)

  • Kim, Jun-Soo;Seul, Youngyoon;Lee, Du-Yong;Park, Kitae;Kim, Tae Hun;Choi, Jae-Hyuk;Lee, Won-Ju
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.4
    • /
    • pp.550-556
    • /
    • 2021
  • The scissor-type rope cutter is the most widely used amongst all kinds of commercially available rope cutters in Korea. In this study, we performed finite element analysis on the scissor-type rope cutter. We determined the structure of the cutter that would ensure its stable operation in various situations involving rope entanglement, and verified its effectiveness by testing it in the lab and in an actual ship. These investigations revealed that when the propeller shaft was not rotated by rope entanglement, the constant torque generated by the engine resulted in the torsion of the rope cutter and maximum deformation in the lower blade, which was not restricted by finite element analysis. With increasing blade thickness, the maximum values of deformation and equivalent stress decreased, resulting in a rise in the safety factor. At the constant blade thickness, the effect of the torque variations on the maximum equivalent stress and the maximum deformation is independent of the position of the external force of the rope cutter and decreases in direct proportion. The results of this study confirmed that the rope-cutter structure determined by analysis could lead to a hassle-free removal of ropes and fishing nets under all conditions and environments.

Rupture Prediction of the Rupture Disk Using Elasto-Plastic Analysis (탄소성해석을 이용한 파열판의 파열예측)

  • Han, Houk-Seop;Lee, Won-Bok;Koo, Song-Hoe;Lee, Bang-Eop
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.3
    • /
    • pp.49-56
    • /
    • 2012
  • Rupture disks are a kind of safety device in high pressure equipment and they are used to control rupture pressure in the solid rocket motor. In this paper, a series of rupture experiments was performed using rupture disks made of AISI 316L and rupture pressure of rupture disks was calculated through various assumptions in relation between elasto-plastic material properties and true stress-strain curve. Experiment and FEA indicated rupture pressure is determined by size of rupture disks. As a result of elasto-plastic analysis, only multi-linear stress-strain curve was able to calculate meaningful estimations. Experimental results also showed rupture location are decided by the size of rupture disks. Experimental and FEA results will be applied to control rupture pressure of disks.