• Title/Summary/Keyword: 베타 방사선

Search Result 97, Processing Time 0.025 seconds

Effect of Gamma-Irradiation on the Whitening Activity of β-Glucan (감마선 조사가 베타글루칸의 미백활성에 미치는 영향)

  • Kim, Jae-Hun;Sung, Nak-Yun;Jung, Pil-Moon;Song, Beom-Seok;Choi, Jong-il;Byun, Eui-Hong;Kim, Jin-Kyu;Lee, Ju-Woon
    • Journal of Radiation Industry
    • /
    • v.4 no.3
    • /
    • pp.233-237
    • /
    • 2010
  • This study evaluated the change in whitening activity of ${\beta}-glucan$ by gamma-irradiation. Tyrosinase inhibition was significantly increased in the samples with 30, 50, 100 kGy irradiated ${\beta}-glucan$. Melanin synthesis of irradiated ${\beta}-glucan$ was measured from B16BL6 melanoma cell line treated with ${\alpha}-melanin$ stimulating hormone. Melanin synthesis was increased in the ${\alpha}-melanin$ stimulating hormone added group. However, it was decreased in the groups of 30, 50 and 100 kGy gamma-irradiated ${\beta}-glucan$ treated with ${\alpha}-melanin$ stimulating hormone. These results indicate that gamma irradiated ${\beta}-glucan$ may elevate the whitening activity. Therefore, gamma-irradiated ${\beta}-glucan$ could be used for nutraceutical foods in cosmetic industry.

Determination of Gross-${\beta}$ and ${\gamma}$-Ray Activity Concentrations of Human Tooth (치아의 전베타 농도 및 감마선 방사능 평가)

  • Jeong, Hyunja;Kang, Hyun-Kyung;Kim, Sunghwan
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.261-265
    • /
    • 2014
  • The ${\gamma}$-ray concentration and gross-${\beta}$ activity by age group were measured in the teeth of males and females of the domestic residents. They were divided into 7 age groups from 10s to the age of 70s. The gross-${\beta}$ activity concentration was measured by using the Tennelec XLB measuring instrument filled with P10 gas (argon 90%, methane 10%). The ${\gamma}$-ray was measured through the ${\gamma}$-ray spectroscopic analytical method by using the high purity germanium (HPGe) radiation detector. The range of gross-${\beta}$ activity concentration was measured 0.089 to 0.32 Bq/kg in females and 0.13 to 0.26 Bq/kg in males. From the ${\gamma}$-ray spectroscopic analysis of the teeth, the natural radioactive isotopes of $^{40}K$, $^{208}Tl$, $^{228}Ac$ and $^{234}Th$ were detected and their measured ${\gamma}$-ray activity concentrations were found to be 20.7, 21.9, 3.88 and 5.24 Bq/kg, respectively.

A Study on the Shielding of Iodine 131 Using Monte Carlo Simulation (몬테칼로 모사를 이용한 방사성옥소 I-131의 차폐체에 대한 효용성 연구)

  • Jang, Dong-Gun;Yang, Seoung-Oh;Kim, Jung-Ki;Lee, Sang-Ho;Choi, Hyung-Seok;Bae, Cheol-Woo
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.143-150
    • /
    • 2014
  • This study was designated to investigate the bremsstrahlung and radiation dose by beta rays. Radiation attenuation from I-131 treatment ward was analyzed using radio protective apron. Shielding materials which is included lead or water were simulated in Monte Carlo Simulation then the spectrum on interaction was analyzed. The shielding materials were categorized according to the thickness. 0.25mm and 0.5mm thick lead and 0.1mm and 0.2mm thick water shielding materials were configured in Monte Carlo Simulation for this study. Only lead shielding method and water plus lead shielding method were carried. As a results, when 0.5mm thick lead shielding method was performed, the radiation dose was similar to the results with water plus lead shielding method. In case of using 0.25mm thick lead shielding, the shielding effect was somewhat less. However, that shielding method cause dose reduction of about 60% compare with non-shielding material.

Quality Management of Radionuclide Activity Meter using Ge-68/Ga-68 Rod Sources (Ge-68/Ga-68 Rod Sources을 이용한 방사능측정기의 정도관리)

  • Jung, Seung Hwan;Jin, Gye Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.575-582
    • /
    • 2018
  • This article compared accuracy of 5 types of radionuclide activity meters that are being used in medical institutions and proposed the correction factor for each radionuclide activity meters type, using Ge-68/Ga-68 radiation sources for scanner setting, regular scanner correction, attenuation correction, and normalization. The calibration constant between baseline values and measured values by CRC-15R, CRC-15 PET, CRC-712M, CRC-15 Beta, and CRC-25PET was 0.99999(P<0.0001), which showed very high linearity. In the accuracy test, CRC-15R, CRC-15 PET, CRC-712M, CRC-15 Beta, and CRC-25PET model showed -3.232%, -1.342%, -2.815%, -2.913%, and -3.089% respectively.

Preparation of an Inorganic Scintillator Loaded Film for the Measurement of Surface Contamination and its Performance Test (표면오염 측정용 무기섬광 함침 필름의 제조 및 성능 평가)

  • 서범경;이근우;임난주;박진호;한명진
    • Journal of Energy Engineering
    • /
    • v.13 no.2
    • /
    • pp.93-100
    • /
    • 2004
  • The smear media possible to sampling and radiation detection was prepared and evaluated for the surface contamination using indirect method. The films were made by impregnating Cerium Activated Yttrium Silicate (CAYS) in a polysulfone membrane. The membranes used solution as a dimethylformamide (DMF) and methylene chloride (MC), polysulfone as a polymer matrix and CAYS as a inorganic scintillator. The proximity membranes were prepared with single- and double-layered structure. The solidified methods were immersion to the nonsolvent bath such at water and ethanol and solvent evaporation. The measurement of the photon produced by interaction with radiation and inorganic scintillator used a photomultiflier tube (PMT), amplifier, and counter. In the comparison with the low background alpha/beta counter, the counter rate using inorganic scintillator proximity membrane for the $\^$14/C surface contamination was about 50%. Also. the $^3$H counting results revealed that the prepared membranes were efficient to monitor the surface contaminated with the low energy be-ray emitter nuclides.

The study on the Effect of relaxation of stress E.D.T applies (E.D.T 적용이 스트레스 완화에 미치는 효과 연구)

  • Han, Byungsung;Kim, Weanjun;Hong, Seonggyun
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.515-520
    • /
    • 2012
  • The stress of modern society as the biggest areas of interest are being considered to be the cause of all disease. These stresses affect the brain, particularly in the unusual, the reduction of alpha-wave is that it happens. In this study, about the stress of alfa-wave EDT alternative medicine techniques to evaluate whether the positive impact is on. Application of the 10 minutes 2 times a week carried out two weeks with the following conclusions were protruding. Alternative Medicine EDT to apply techniques to stabilize the meaning of the EEG alpha and beta wave of the increase was reduced, showed no significant effect in reducing gamma-wave suggest that there is some help. Through these results, EDT alternative medicine technique stress in alfa-wave because of the significant effects in improving elementary school teachers on stress management and emphasizes the necessity of actively used.

Analysis on Fluorine-18 Shielding Efficiency of Double Shield Apron using Acrylic (아크릴을 활용한 이중 차페 Apron의 F-18 차폐 효율 분석)

  • Lee, Gwon-Seong;Jeon, Yeo-Ryeong;Kim, Yong-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.957-964
    • /
    • 2021
  • Fluorine-18 used in PET/CT scans is a radioactive isotope that emits positrons, and high energy annihilation gamma rays and beta rays cause exposure to radiation workers. In this study, as part of a plan to reduce the exposure dose of radiation workers working in the Department of Nuclear Medicine, the cause of the low shielding efficiency of Apron for F-18 was identified, and the effectiveness of the Apron double-shielded with acrylic was evaluated. L-Block, Apron+acrylic, Apron, Acrylic+Apron, and Acrylic five shields are used to measure the dose, and the tendencies were compared by performing a Monte Carlo simulation. As a result, it was found that the shielding rate of Apron double shielded with acrylic was about 4 to 8% higher than that of Apron single shielded. To the extent that it does not significantly affect the user's activity, double-shielded personal protective clothing with an appropriate acrylic thickness could help reduce radiation workers' exposure.

Dose rate conversion factor for soil by the beta-rays and gamma-rays from 238,235U, 232Th and 40K (238,235U, 232Th과 40K의 베타선 및 감마선에 의한 토양의 흡수선량 환산 인자)

  • Kim, Gi-Dong;Eum, Chul-Hun;Bang, Jun-Hwan
    • Analytical Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.460-467
    • /
    • 2007
  • Dose rate conversion factor was calculated to estimate the absorbed effective annual doses for soils for the beta-rays and gamma-rays, which were emitted from $^{238,235}U$, $^{232}Th$, and $^{40}K$ isotopes. The most recent data of the emitted energies per decay, half-lifes, and branching ratios, which were obtained from National Nuclear Data Center, were used. When this factor and the effective annual doses for the beta-rays and the gamma-rays of natural radioisotopes were compared with those of Aitken, these of $^{238}U$, $^{232}Th$ and $^{40}K$ are estimated to have good agreements but a large difference is shown in this for $^{235}U$. Through the calculations of effective annual doses by using these factor and the measurements of gamma-ray spectra for soils, which were extracted from prehistoric remains (Mansuri) on Osong, Chungchengbuk-do, The annual effective doses were obtained to be 3.8~5.9 mGy/yr. Also, when these doses including decay elements upper Rn were compared with those on all isotopes, the differences within 9~30 % were obtained. The analysis method of the annual effective doses for the beta-rays and the gamma-rays of the natural isotopes of soils was established by this dose rate conversion factor.

OVERVIEW OF HEALTH PHYSICS STUDIES ON TRITIUM BETA RADIATION (삼중수소 베타방사선에 관한 보건물리 연구의 적용)

  • Hwang, Sun-Tae;Hah, Suk-Ho
    • Progress in Medical Physics
    • /
    • v.5 no.1
    • /
    • pp.75-85
    • /
    • 1994
  • As we enter the 2000s, there are four nuclear power units of the pressurized heavy water reactor-type in the commercial operation at the Wolsung Nuclear Power Plant(NPP) site where a larger amount of tritium ($\^$3/H) is released inevitably to the site environment. This radioctive nuclide is easily distributed throghout our environment because of its ubiquitous form as tritiated water (HTO) and its persistence in the environment. Tritum has certain characterisitics that present unique challenges for beta radiation dosimety and health risk assesment. In this paper, therefore, a variety of matters on tritium are considered and reviewed in terms of its characteristics and sources, metabolism and dosimetry, microdosimetry, radiobiology, risk assessment, and transport and cycling in the environment, etc.

  • PDF

Effect of Porcine Cancellous Bones on Regeneration in Rats with Calvarial Defect (랫드의 두개골 결손부에서 돼지 해면질골이 골재생에 미치는 영향)

  • Yoo, Kyeong-Hoon;Kim, Se-Eun;Shim, Kyung-Mi;Park, Hyun-Jeong;Choi, Seok-Hwa;Kang, Seong-Soo
    • Journal of Life Science
    • /
    • v.20 no.8
    • /
    • pp.1207-1213
    • /
    • 2010
  • The purpose of this study was to evaluate the effect of porcine cancellous bone as a scaffold in a rat calvarial defect model. Critical-sized defects were created in 30 male Sprague-Dawley rats. The animals were divided into critical defect (CD, n=10), $\beta$-tricalcium phosphate (TCP) graft (BT, n=10) and porcine cancellous bone graft (PCB, n=10) groups. Each defect was filled with $\beta$-TCP mixed with fibrin glue or porcine cancellous bone powder mixed with fibrin glue. In the CD group, the defect was left empty. All rats were sacrificed at 8 weeks after bone graft surgery, and bone formation was evaluated by gross observation, plain radiography, micro-computed tomography scanning and histological evaluation. Repair of bone defect was the least in the CD group, and significant new bone formation was observed in the PCB group. Grafting of porcine cancellous bone was more efficient for regenerating new bone than grafting $\beta$-TCP.