• Title/Summary/Keyword: 백색광 스캐너

Search Result 11, Processing Time 0.026 seconds

A Study on the Evaluation of Repeated Measurement Stability of 3D Tooth Model Obtained by Several Dental Scanners (수종의 치과용 스캐너로 채득된 3차원 치아 모형의 반복측정 안정성 평가 연구)

  • Bae, Eun-Jeong;Kim, Won-Soo;Lim, Joong Yeon
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.5
    • /
    • pp.996-1003
    • /
    • 2021
  • The purpose of this study is to evaluate the reliability of repeated measurements of several dental scanners. Blue-lighted scanners, white-light scanners and optical-type scanners are used in the study of repeatability in this study. The measurement results were calculated as root mean square (RMS) and the significance level was confirmed by applying the 1-way ANOVA statistical technique (𝛼=.05). According to the statistical analysis, the scanner with the largest RMS value was Z-opt group (38.2 ㎛. Next, D-white was 35.2 ㎛ and the group with the lowest RMS value was I-blue (34.1 ㎛). The comparison of RMS means between each group was not significant (p>.05). From this result, the blue light had the lowest error in repeatability of dental scanners, but no statistical significance. The conclusion of this study is that the study results are clinically acceptable.

Evaluations of the Accuracy and Reliability of Measurements Made on White Light Scanner-based Dental Digital Models (백색광 스캐너로 채득된 치과용 디지털모형의 정확도와 신뢰도 평가)

  • Kim, Ki-Baek;Kim, Jae-Hong
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.10
    • /
    • pp.357-364
    • /
    • 2012
  • Dental scanner-based dental digital models have been developed that have the potential to replace conventional stone model. The aim of this study was examine the accuracy and reliability of measurements made on digital models. A master model with the prepared upper full arch tooth was used. Stone model(N=10) were produced from master model, and on the other hands, digital models were made with the white light scanner(Identica, korea). One examiner individually measured 6 parameters on the conventional model and the digital models on two occasions. The student's t-test for paired samples and intra-class correlation coefficient(ICC) were used for statistical analysis. At the intra-examiner reliability of measurement, ICC at the stone and digital models were 0.75 and 0.87. The mean difference between measurements made directly on the stone models and those made on the digital models was 0.11-0.23mm, and was statistically significant(P<0.05). These in vitro studies show that accuracy of the digital model is similar to that of the stone model. These results will have to be confirmed in further clinical studies.

Evaluation of the Model Accuracy according to Three Types of Dental Scanner (세 가지 방식의 스캐너 종류에 따른 모형 정확도 평가)

  • Lee, Jae-Jun;Park, Jin-Young;Bae, So-Yeon;Jeon, Jin-Hun;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of dental hygiene science
    • /
    • v.15 no.2
    • /
    • pp.226-231
    • /
    • 2015
  • The purpose of this study was to evaluate the accuracy of model according to three types of dental scanner. A maxillary acrylic model was prepared and duplicated 10 times by silicone impression materials. Corresponding working casts were formed from scannable stone and got a 3-dimensional digital models using three different scanners. The distance of each measurement region was measured using vernier calipers and the respective program. One-way ANOVA and the Tukey honestly significant difference post hoc test (${\alpha}=0.05$) was performed using IBM SPSS Statistics 21.0. Overall, the stone cast is smaller than the digital models in measurement distance. And measuring point value of laser scanner showed the most similar values and measurement points value of digital vernier calipers. Digital model of white light scanner showed similar values in the measurement points value of the blue light scanner. In conclusion, the laser scanner showed the best accuracy among the three types of dental scanner. However, the difference between the digital models and the stone cast can be accommodated in making prostheses. Thereby, three types of dental scanner are available in a clinically acceptable range.

The Influence of Different Gypsum Materials on the Accuracy from Complete Arch Digital Impression (전악의 디지털 인상 채득 시 치과용 모형재가 디지털 모형 정확성에 미치는 영향)

  • Kim, Ki-Baek;Lee, Gyeong-Tak;Kim, Hae-Young;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.12 no.6
    • /
    • pp.617-623
    • /
    • 2012
  • This study was performed to measure the accuracy of different gypsum materials by a white light dental scanner. A master model with the prepared lower full arch tooth was used. The type IV and scannable stone were used for 20 stone casts (10 casts each) duplicated a master model of mandible. The distance between the reference points were measured and analyzed by the Delcam $Copycad^{(R)}$ (Delcam Plc, UK) 3D graphic software. The t-student test for paired samples were used for statistical analysis. The mean differences to master model for type IV stone and scannable stone model were 0.29~0.56 mm, and 0.17~0.35 mm, respectively. There were statistical differences in dimensional accuracy for full arch impression between the master model and type IV/scannable stone (p<0.05). Two different gypsum materials showed clinically acceptable accuracies of full arch digital impression produced by them. Besides, in both gypsum materials, the differences to the master model detected appear to provide enough accuracy for clinical application.

Comparative analysis on digital models obtained by white light and blue LED optical scanners (백색광과 청색 LED 방식의 광학스캐너로 채득된 디지털 모형의 비교분석)

  • Choi, Seog-Soon;Kim, Jae-Hong;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.36 no.1
    • /
    • pp.17-23
    • /
    • 2014
  • Purpose: The purpose of this study was to analyze and compare the relative accuracy of digitized stone models of lower full arch, using two different scanning system. Methods: Replica stone models(N=20) were produced from lower arch acrylic model. Twenty digital models were made with the white light and blue LED($Medit^{(R)}$, Korea) scanner. Two-dimensional distance between the landmarks were measured on the Delcam $CopyCAD^{(R)}$(Delcam plc, UK). Independent samples t-test was applied for comparison of the groups. All statistical analyses were performed using the SPSS software package(Statistical Package for Social Sciences for Windows, version 12.0). Results: The absolute disagreement between measurements made directly on the two different scanner-based dental digital models was 0.02~0.04mm, and was not statistically significant(P>0.05). Conclusion: The precision of the blue LED optical scanner was comparable with the digitization device, and relative accuracy was similar. However, there still is room for improvement and further standardization of dental CAD technologies.

Comparison of reproducibility of prepared tooth impression scanning utilized with white and blue light scanners (백색광과 청색광 스캐너를 이용한 지대치 인상체 스캐닝의 반복재현성 비교)

  • Jeon, Jin-Hun;Sung, Hwan-Kyung;Min, Byung-Kuk;Hwang, Jae-Sun;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.37 no.4
    • /
    • pp.213-218
    • /
    • 2015
  • Purpose: The purpose of this study compared of reproducibility of prepared tooth impression scanning utilized with white and blue light scanners. Methods: To evaluate reproducibility with white and blue light scanners, the impression of premolar were rotated by $10^{\circ}{\sim}20^{\circ}$ and scanned. These data were compared with the first 3-D data (STL file), and the error sizes were measured (n=5). Independent t test was used to evaluation the reproducibility of impression of premolar with white versus blue light scanners through discrepancies of mean, RMS (${\alpha}=0.05$). Results: Discrepancies of mean with regard to reproducibility were $11.2{\mu}m$, $5.8{\mu}m$, respectively, with white and blue light scanners (p<0.047). And discrepancies of RMS with regard to reproducibility were $33.4{\mu}m$, $18.8{\mu}m$, respectively, with white and blue light scanners (p<0.045). Conclusion: Our results indicate a good reproducibility of prepared tooth impression digitized with blue light scanner more than that with white light scanner.

Evaluation on the repeatability of dental white light scanner-based digital impression (치과용 백색광 스캐너를 이용한 impression scanning의 반복 측정에 대한 안정성 평가)

  • Jeon, Jin-Hun;Lee, Kyung-Tak;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.35 no.1
    • /
    • pp.37-42
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the repeatability of dental white light scanner. Methods: The impression(Zerosil, Dreve, Germany) were digitized in white light scanner(Identica, Medit, Korea) to create 3-dimensional surface-models. The distribution of the discrepancies between the number of points in the corresponding CRM models and the point clouds in the others were measured by a matching-software(PowerInspect 2012, Delcam Plc, UK). The discriptive statistics were used for statistical analysis(SPSS 20.0). Results: The measurement of repeatablity showed very good reliability. The mean(SD) discrepancy value on the white light scanner digital models was 8.7(0.67) ${\mu}m$, based on SD and absolute mean values. Conclusion: These in vitro studies showed that repeatability of dental white light scanner is high reliability. These results can be confirmed in further clinical studies.

Comparison of the accuracy of digital models made from white light scanner by scanning method (스캐닝 방법에 따른 백색광 스캐너 기반으로 채득된 디지털 모형의 정확성 비교)

  • Kim, Ki-Baek;Lee, Gyeong-Tak;Kim, Jae-Hong
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.6
    • /
    • pp.1082-1089
    • /
    • 2012
  • Objectives : The aim of this study was to determine the accuracy of digitized stone models, impression materials compared to the master model and the reliability of the computer aided analysis. Methods : A master model(500B-1, Nissin dental product, Japan) with the prepared lower full arch tooth was used. Ten vinyl polysiloxane impressions(Examix$^{(R)}$, GC Industrial Corp, Japan) of master model were taken and type IV stone(aesthetic-base gold$^{(R)}$, Dentona, Germany) were poured in stone models. The linear distance between the reference points were measured and analyzed on the Delcam Copycad$^{(R)}$(Delcam plc, UK). The t-student test for paired samples was used for statistical analysis. Results : The mean differences to master model for stone model and impression material were 0.11~0.19mm, and 0.19~0.29mm, respectively. There were statistical differences in dimensional accuracy for full arch impression between master model and stone model/impressions(p<.05). Conclusions : Two different scanning methods showed clinically acceptable accuracy of full arch digital impression produced by them. These results will have to be confirmed in further clinical studies.

Accuracy of Digital Impression Made from Different Elastomeric Impression Materials: Three-Dimensional Superimpositional Analysis (치과용 탄성 인상재를 기반으로 채득된 디지털 모형의 정확성 연구: 3차원 중첩 분석)

  • Kim, Ki-Baek;Jung, Jae-Kwan;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.14 no.2
    • /
    • pp.94-100
    • /
    • 2014
  • The purpose of this study was to evaluate the accuracy of digitized elastomeric impression materials of crown abutment, using non-contact white light scanner and virtual three-dimensional superimpositional analysis. The stone models and impressions were digitized white light scanner to create three-dimensional surface models. Stone models were used as CAD reference model (CRM). The resulting point clouds (ASC file) from digitization of impressions using converting software. Discrepancies between the points in the point clouds and CRM were measured by superimpositional software. Mean and standard deviation of values of discrepancies were analyzed by one-way ANOVA and multiple comparison (${\alpha}=0.05$). The mean discrepancy between the impressions for the extra-light body (XLB), light body (LB), and heavy body (HB) group were $5.10{\pm}1.45{\mu}m$, $6.30{\pm}1.87{\mu}m$, $9.80{\pm}1.52{\mu}m$, respectively. The different impression materials affected the digitization of impressions significantly (p<0.05). As a result, digitization of elastomeric impression materials on dental scanner was influenced by material sort.