• 제목/요약/키워드: 배전 선로

검색결과 671건 처리시간 0.028초

배전용 절연카바류의 경년특성 분석 (The Analysis of Ageing Characteristics of Insulation Cover Using in Distribution Line)

  • 김동명;송일근;한재홍;이병성;한용회;이태선
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.76-78
    • /
    • 2001
  • In this paper insulation cover that being used in distribution line have been evaluated for aging characteristics. For evaluating its aging properties, we dismounted a variety of samples, like insulation covers for termination of deadend clamp, bushing, LA, COS and sleeve, in the fields. we performed mechanical properties test, electrical test, weathering test, etc. of these samples. And these samples are compared with virgin sample. Test results shows the bad mechanical strength in some part of samples. Especially, Insulation covers for the bushing terminations have cracks in the surface of samples.

  • PDF

배전용 변압기를 통한 저압전원선으로의 뇌서지 전파 (Propagation of Lightning Surges on Power AC Lines through Distribution Transformers)

  • 이복희;이수봉;이동문
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.468-471
    • /
    • 2002
  • A strong need to improve the quality of electric power is increased because of increasing use of the sensitive and small-sized electronic devices. The surges on the low-voltage ac power lines are induced by nearby lightning return strokes, and the facilities for HA, OA, FA, ME as well as computer are easily damaged by high-voltage transients. The behaviors of lightning surge characteristics transferred from the primary winding to the secondary winding in distribution transformers using a Marx generator were experimentally investigated. The transfer characteristics of lightning surge associated with a custom service ground of secondary side were also examined.

  • PDF

섬락 단선 방지 장치에 의한 피복 절연 가공배전 선로의 유도뢰애 의한 단선 방지 (Arc Fusion Protection of Covered Conductors Using AFPD)

  • 이용한;정동학;하복남;남궁도;김명수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.800-802
    • /
    • 1997
  • After flashover occurs on the overhead distribution line by lighting strokes(direct or induced), the power frequency arc current continues. If lightning flashover occurs on the overhead lines using covered conductors, the power frequency art current with fixed path overheats the conductor, and arc fusion fault can be occurred. There are two categories protecting or reducing methods of arc fusion faults caused by lightning stokes. - Reducing lightning flashover rate : G/W, LA, etc. - Protection by AFPD(Arc Fusion Protection Device) : power follow current interruption. This paper presents lightning surge phenomena on overhead distribution lines and protecting performance of arc fusion Protection devices to the lightning strokes nearby overhead line.

  • PDF

배전선로 무정전 공법의 현장 적용상의 문제점과 전망 (Application of outage-free work techniques to distribution lines)

  • 박중신;권오형;이재관
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.966-968
    • /
    • 1997
  • Our country is still suffering from much work outage, nearly 80% of total outage time, in 22.9kV-Y multi-grounded distribution lines. Therefore, KEPCO which is the sole utility owned by the Korean government has developed outage-free work techniques to improve the reliability of power supply in Our country. This paper is to introduce the developing process and good effects of outage-free work techniques, and the equipment developed and applied in Our country. This paper will aid many utilities to try to reduce the work outage.

  • PDF

저압 배전선 반송 방식의 원격검침 실증 연구 (The Study on the Automated Meter Reading using Low Voltage Power)

  • 박상만;하복남;이중호;조남훈;김명수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.985-987
    • /
    • 1997
  • AMR(Automated Meter Reading) has been considered to solve the lack of meter mem caused by the rise of cost, inefficiency of manual meter reading. Demand forecasting and efficient management of facilities can be accomplished by increasing meter reading efficiency and correcting various data. In this paper, we introduce AMR system using LV PLC in KANG-DONG blanch office of KEPCO.

  • PDF

배전선로 규정전압 유지를 위한 전류 측정치 기준의 무효전력 제어방법 (Current Measurement based Reactive Power Control to Mitigate Overvoltage of Primary Distribution Line)

  • 황지희;임성일
    • 전기학회논문지
    • /
    • 제66권11호
    • /
    • pp.1547-1553
    • /
    • 2017
  • Due to the high penetration ratio of dispersed generations, overvoltage problem of the feeder has become more an important issue in distribution system operation. This paper proposes a new method for the smart inverter to control reactive power to mitigate voltage rise by the reverse power flow from the DGs. The proposed method controls reactive power based on current measurement while conventional methods use voltage measurement which include unacceptably large errors. Various case studies using MATLAB simulation have been performed to verify effectiveness of proposed method.

22.9[kV] 배전선로 주변의 전장과 자장의 분포 (Profiles of Electric and Magnetic Fields around 22.9[kV] Distribution Lines)

  • 이복희;;박종순;길형준
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제13권2호
    • /
    • pp.178-178
    • /
    • 1999
  • In recent years, the electromagnetic environments are varied with the increase of power consumption and the spread of household electric appliances. Most of the interests to date have concentrated in the area of human health effects associated with exposure to power frequency electric and magnetic fields, and thus the precise measurement and analysis are required. In this paper, the measurements and analysis of the extremely low frequency(ELF) electric and magnetic fields produced by actual 22.9[kV] distribution lines were performed. The experiments have been carried out by lateral profile, and the theoretical analyses were made by use of FIELDS program for the sate of comparison with the experimental data. Electric and magnetic field intensity were strong under power distribution lines, and were inversely proportional to lateral distance. The profiles of electric and magnetic fields were M and ∩ shapes, respectively, and the measured data were good in agreement with the theoretical results. Both the electric and magnetic field intensity were increased with increasing the measurement height.

신경회로망을 이용한 배전선로 고저항 사고 검출 기법의 개발 (Development of a hight Impedance Fault Detection Method in Distribution Lines using Neural network)

  • 황의천;;김남호
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제13권2호
    • /
    • pp.212-212
    • /
    • 1999
  • This paper proposed a high impedance fault detection method using a neural network on distribution lines. The v-I characteristic curve was obtained by high impedance fault data tested in various soil conditions. High impedance fault was simulated using EMTP. The pattern of High Impedance Fault on high density pebbles was taken as the learning model, and the neural network was valuated on various soil conditions. The average values after analyzing fault current by FFT of evenr·odd harmonics and fundamental rms were used for the neural network input. Test results were verified the validity of the proposed method.

배전 선로의 열화 진단을 위한 복합 카메라 보정기법 (A Composite Camera Calibration Technique for Thermal Deterioration Diagnosis of Power Distribution Line)

  • 정하형;박진하;유준
    • 제어로봇시스템학회논문지
    • /
    • 제22권6호
    • /
    • pp.463-469
    • /
    • 2016
  • This paper presents a composite camera calibration method to determine thermal degradation of power distribution equipment by combining an infrared (IR) camera and a color camera. A calibration jig was first constructed to match the properties of the two cameras. Our calibration and visualization techniques allow for the display of two images, one from the color camera and the other from the IR camera with different field of views (FOVs), on the screen at the same time. To confirm its validity, several case studies have been developed to analyze thermal deterioration limits of indoor and outdoor power distribution facilities.

한전 배전선로 주변에 위치한 J가압장의 피뢰설비 구축방안 검토 (To examine the construction plan of the lightening rod equipment for the J-booster pumping station in and around KEPCO'a high voltage distribution power line)

  • 홍성택;이은춘;신강욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.293-295
    • /
    • 2003
  • KEPCO's high voltage distribution power line laid under the ground near to the J-booster pumping station that supply water for living. Lightening rod equipment does not installed at the J-booster pumping station because KEPCO's over head ground wire for protection functions as a lightening rod equipment. In this study, it is concerned whether KEPCO's over head ground wire for protect the distribution power line affect to the J-booster pumping station which is installed for reduce the damage from the direct and indirect lightening. If KEPCO's protection area does not affect to the J-pumping station, it is plan to examine the construction method of lightening rod protection angle and lightening rod equipment and to suggest the optimum protection plan using the surrounding structure based on the suitability of protection area.

  • PDF