• Title/Summary/Keyword: 방향오차

Search Result 1,225, Processing Time 0.037 seconds

An Analysis of GPS Station Positioning Accuracy Variations According to Locations of Obstacles (장애물 위치에 따른 GPS 기준국 측위정확도 변화분석)

  • Sohn, Dong-Hyo;Park, Kwan-Dong;Jung, Wan-Suk;Kee, Changdon
    • Journal of Navigation and Port Research
    • /
    • v.37 no.5
    • /
    • pp.463-469
    • /
    • 2013
  • This paper focuses on GPS positioning accuracy variations according to locations of obstacles which surround GPS station. We derived precise coordinates of a GPS station which has a good visibility. Its observation data was rewritten by assuming signal blocking due to obstacle in the elevation angle of $10^{\circ}$ to $70^{\circ}$. We processed daily and hourly data for 10 days. In the results using daily data, RMSE was at 10mm level. And RMSE increased to 100mm levels in case of hourly data. As the elevation angle of obstacle increased, the horizontal and vertical RMSE increased, while the height estimates decreased. These results showed the higher the elevation angle of the obstacle increased the loss of large amounts of data by blocking satellite signals direction. In terms of the direction, when the blocking thing was located in the east or west, the coordinate has larger error in the east-west direction. And if signal was blocked at the south direction, the difference between the east-west error and the south-north position error was reduced.

Comparative Analysis and Applicability Evaluation of River Main Flow Direction Search Method using Spatio-Temporal Volume analysis (시공간체적 분석법을 활용한 하천 주흐름 방향 탐색방법의 비교 분석 및 적용성 평가)

  • Lee, Yun Ho;Yu, Kwon Kyu;Yoon, Byung Man;Kim, Seo Jun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.15-15
    • /
    • 2022
  • 우리나라 홍수 발생은 강수량이 집중되는 여름철에 집중되어 있어 홍수피해 방지에 주의가 필요하다. 보와 제방 등 이러한 홍수 피해를 대비하기 위한 구조물에 설계를 위해서는 하천의 유량 조사가 필수적으로 요구된다. 하지만 홍수기 직접적인 유량 조사는 안전상의 이유로 거의 이루어지지지 않고 있으며, 수위를 측정하여 수위-유량 관계를 만들어 유량을 측정하고 있다. 그러나 중소 규모의 하천의 경우 하도 경사가 급해 사류가 발생하거나 하도 단면이 급변하는 경우가 있어 수위-유량 관계를 그대로 적용하기 어려운 문제가 있다. 따라서 이러한 문제를 해결하기 위해 하천에 진입하지 않고 유속을 측정 할 수 있는 영상유속계와 같이 흐름 영상을 사용하여 유속을 측정하는 방법들이 개발되었다. 영상유속계의 측정 방법중 Spatio Temporal Image(시공간 영상)을 사용하는 방법은 일정시간의 시간평균 유속을 산정할 수 있고 한 장의 시공간 영상을 분석하기 때문에 유속 산정에 걸리는 시간이 작은 장점이 있지만 영상 내 흐름 방향을 정확히 설정하지 못하면 오차가 생길 수 있는 문제가 있어 주 흐름 방향을 정확히 탐색할 필요가 있다. 따라서 본 연구에서는 영상에서 시공간 체적을 만들어 주흐름 방향을 찾아내는 기법들의 장단점을 비교하고 안동 하천실험센터의 실규모 하천수로에 적용하여 결과를 비교하고 적용성을 평가하였다. 이를 위해 하천수로에 추적자를 살포하여 영상으로 녹화하였으며 녹화된 영상을 자기상관법과 시간적분법을 적용하였으며, 이를 통해 주 흐름 방향을 판별하였다. 또한 두 방법을 통해 결정된 주흐름 방향을 적용하여 시공간 영상을 제작하고 이를 이용하여 유속을 산정하여 비교하였으며, 주흐름 방향을 산정하는데 생기는 오차가 유속 계산에 얼마만큼의 영향을 끼치는지 분석하였다. 이러한 실험을 통해 하천에서 시공간 영상을 활용한 표면영상 유속계측 방법을 활용하는데 있어 도움이 될 것으로 기대된다.

  • PDF

Systematic error calibration of 2-axis lateral shearing interferometer (2축 층밀리기 간섭계의 계통오차 보정)

  • 김승우;이혁교
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.2
    • /
    • pp.98-104
    • /
    • 2002
  • We present a new self-calibration method to remove the systematic error of a 2-axis lateral shearing interferometer that has been specially designed for optical testing of aspheric optics. The method takes multiple measurements by rotating the test optics and extracts the systematic error by fitting the measured wavefronts into the Zernike polynomials. The method works with arbitrary azimuthal angles for test optics rotation, which offers an advantage of correcting the error induced by the non-orthogonality of the two axes of wavefront shearing as well as the error caused by the optical components of the interferometer system itself.

A algorithm development on optical freeform surface reconstruction (광학식 자유곡면 형상복원 알고리즘 개발)

  • Kim, ByoungChang
    • Journal of the Korea Convergence Society
    • /
    • v.7 no.5
    • /
    • pp.175-180
    • /
    • 2016
  • The demand for accurate freeform apsheric surface is increasing to satisfy the optical performance. In this paper, we develop the algorithm for opto-mechatronics convergence, that reconstruct the surface 3D profiles from the curvarure data along two orthogonal directions. A synthetic freeform surface with 8.4 m diameter was simulated for the testing. The simulation results show that the reconstruction error is 0.065 nm PV(Peak-to-valley) and 0.013 nm RMS(Root mean square) residual difference. Finally the sensitivity to noise is diagnosed for probe position error, the simulation results proving that the suggested method is robust to position error.

Error analysis for a strapdown inertial navigation system (스트랩다운 관성항법장치의 오차해석)

  • 심덕선;박찬국;송유섭
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.286-289
    • /
    • 1986
  • 항법(navigation)은 기준좌표계에 대한 항체(vehicle)의 위치나 속도를 알아내기 위한 것으로 이를 위한 시스템이 관성항법장치(inertial navigation system-INS)이며 항법기능을 수행하기 위하여 항체에 놓여진 쎈서의 관성성질을 이용한다. INS는 specific force와 관성 각속도의 측정에서 얻은 데이타를 처리함으로 그 기능을 수행한다. 스트랩다운 INS(SINS)는 관성항법장치의 한 종류로 analytic INS라고도 하는데 기준좌표축을 유지하기 위하여 안정테이블을 사용하지 않고 쎈서들을 항체에 직접 부착시켜 초기상태와 현재상태와의 사이에 상대적인 회전방향을 해석적으로 계산한다. INS의 성능은 수많은 오차원(error source)의 함수로 주어지며 이 오차원 중에는 주위환경에 의한 것도 있고 INS 구성에 사용된 기구(instruments)와 관련된 것도 있다. INS 를 해석하는 목적은 항법의 정확도를 알아보는데 있으며 또한 각각의 오차원의 값을 추정하는 것도 부가적인 목적이 된다. 이러한 오차의 추정치는 사양(specification)을 모르는 부품의 성능을 식별하는데 사용될 수 있다. 따라서 INS를 해석함으로 INS를 구성하는 어떤 부품에 대한 성능이 어느정도 개선을 필요로 하는가 알 수 있다. 본 논문에서는 SINS의 오차원을 크게 고도계의 불확실성, 중력의 편향과 이상, 가속도계의 불확실성, 자이로의 불확실성의 네 그룹으로 나누어 상호분산해석(covariance analysis)방법으로 각 오차원이 시스템에 미치는 영향을 알아보았다.

  • PDF

A Gradient Method Based Near-Field Range Estimation Technique Robust to Direction-of-Arrival Error (방위각 오차에 강인한 경사법 기반 근접장 표적 거리 추정 기법)

  • Kim, Joon-Doo;Cho, Chom-Gun;Lee, Chung-Yong
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.49 no.2
    • /
    • pp.130-136
    • /
    • 2012
  • In this paper, we propose a near-field range estimation method for a uniform linear array that can calibrate bearing estimation error which give a bad influence on a range estimation process. When a range is fixed, the bearing error is calibrated to maximize the beamformer output by the proposed algorithm based on the gradient method. Simulation results show that the proposed algorithm can compensate the bearing error which is less than the mainlobe beamwidth so that reduce the range estimation error as similar as the case of no bearing error.

Evaluation of Setup Errors for Tomotherapy Using Differently Applied Vacuum Compression with the Bodyfix Immobilization System (토모테라피 치료 시 Bodyfix System에서 진공압박에 따른 환자 위치잡이오차(Setup errors)의 평가)

  • Jung, Jae-Hong;Cho, Kwang-Hwan;Lee, Jeong-Woo;Kim, Min-Joo;Lim, Kwang-Chae;Moon, Seong-Kwon;Kim, Yong-Ho;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.72-78
    • /
    • 2011
  • The aim of this study is to evaluate the patient's setup errors in TomoTherapy (Hi-Art II, TomoTherapy, USA) Bodyfix system (Medical Intelligence, Ele-kta, Schwabmuchen, Germany) pressure in the vacuum compression, depending on and were evaluated. Bodyfix immobilization system and vacuum pressure was compression applied to the patients who received Tomotherapy thoracic and abdominal area, 21 patients were selected and TomoTehpay treatment total 477 of MVCT images were obtained. The translational (medial-lateral: ML, anterior-posterior: AP, superior-inferior: SI directions) and rolling were recorded and analyzed statistically. Using Pearson's product-moment coefficient and One-way ANOVA, the degree of correlation depending on the different vacuum pressure levels were statistically analyzed for setup errors from five groups (p<0.05). The largest average and standard deviation of systematic errors were 6.00, 5.95 mm in the AP and SI directions, respectively. The largest average of random errors were 4.72 mm in the SI directions. The correlation coefficients were 0.485, 0.244, and 0.637 for the ML-Roll, AP-Vector, and SI-Vector, respectively. SI-Vector direction showed the best relationship. In the results of the different degree of vacuum pressure in five groups (Pressure range: 30~70 mbar), the setup errors between the ML, SI in both directions and Roll p=0.00 (p<0.05) were shown significant differences. The average errors of SI direction in the vacuum pressure of 40 mbar and 70 mbar group were 4.78 mm and -0.74 mm, respectively. In this study, the correlation between the vacuum pressure and the setup-errors were statistically analyzed. The fact that setup-errors in SI direction is dependent in vacuum pressure considerly setup-errors and movement of interal organs was identified. Finally, setup-errors, and it, based on the movement of internal organs in Bodyfix system we should apply more than 50 mbar vacuum pressure. Based on the results of this study, it is suggested that accuracy of the vacuum pressure and the quantitative analysis of movement of internal organs and the tumor should be studied.

Development of an Image Processing Algorithm for Paprika Recognition and Coordinate Information Acquisition using Stereo Vision (스테레오 영상을 이용한 파프리카 인식 및 좌표 정보 획득 영상처리 알고리즘 개발)

  • Hwa, Ji-Ho;Song, Eui-Han;Lee, Min-Young;Lee, Bong-Ki;Lee, Dae-Weon
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.210-216
    • /
    • 2015
  • Purpose of this study was a development of an image processing algorithm to recognize paprika and acquire it's 3D coordinates from stereo images to precisely control an end-effector of a paprika auto harvester. First, H and S threshold was set using HSI histogram analyze for extracting ROI(region of interest) from raw paprika cultivation images. Next, fundamental matrix of a stereo camera system was calculated to process matching between extracted ROI of corresponding images. Epipolar lines were acquired using F matrix, and $11{\times}11$ mask was used to compare pixels on the line. Distance between extracted corresponding points were calibrated using 3D coordinates of a calibration board. Non linear regression analyze was used to prove relation between each pixel disparity of corresponding points and depth(Z). Finally, the program could calculate horizontal(X), vertical(Y) directional coordinates using stereo camera's geometry. Horizontal directional coordinate's average error was 5.3mm, vertical was 18.8mm, depth was 5.4mm. Most of the error was occurred at 400~450mm of depth and distorted regions of image.

Evaluation of Usability Both Oblique Verification for Inserted Fiducial Marker of Prostate Cancer Patients (Fiducial Marker가 삽입된 전립선암 환자를 대상으로 한 양사방향 촬영의 유용성 평가)

  • Kim, Koon Joo;Lee, Jung Jin;Kim, Sung Gi;Lim, Hyun Sil;Kim, Wan Sun;Kang, Su Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • Purpose: The way check the movement of the fiducial marker insertion in the treatment of patients with prostate cancer. However the existing methods of fiducial marker verification process difficult to identify the specific location of the marker behind the femur and pelvic bone. So to study the evaluation of maker match with using kilo voltage (KV) X-ray by On-board imager to both oblique verification method. Materials and Methods: Five patients were selected for rectal ballooning and inserted fiducial marker. Compare the position of the fiducial marker of reference plan 2D/2D Anterior/Posterior verification method and 2D/2D both oblique verification method. So to measurement the shift score of X, Y, Z (axis) and measure exposure dose given to patients and compare matching time. Results: 2 dimensional OBI KV X-ray imaging using two-dimensional matching image are orthogonal, so locating fiducial marker matching clear and useful DRR (digital reconstruction radiography) OBI souce angle ($45^{\circ}/315^{\circ}$) matching most useful. 2D/2D both oblique verification method was able to see clearly marker behind the pelvic bone. Also matching time can be reduced accordingly. According to the method of each matching results for each patient in each treatment fraction, X, Y, and Z axis the Mean $value{\pm}SD$ (standard deviation) is X axis (AP/LAT: $0.4{\pm}1.67$, OBLIQUE: $0.4{\pm}1.82$) mm, Y axis (AP/LAT: $0.7{\pm}1.73$, OBLIQUE: $0.2{\pm}1.77$) mm, Z axis (AP/LAT: $0.8{\pm}1.94$, OBLIQUE:$1.5{\pm}2.8$) mm. In addition, the KV X-ray source dose radiation exposure given to the patient taking average when AP/LAT matching is (0.1/2.1) cGY, when $315^{\circ}/45^{\circ}$ matching is (0.27/0.26) cGY. Conclusion: In conclusion for inserted fiducial marker of prostate cancer patients 2D/2D both oblique matching method is more accurate verification than 2D/2D AP/LAT matching method. Also the matching time less than the 2D/2D AP/LAT matching method. Taken as the amount of radiation exposure to patients less than was possible. Suggest would improve the treatment quality of care patients more useful to establish a protocol such as case.

  • PDF

Numerical analysis for nearfield measurement error in a three-dimensional intensity probe. (3차원 인텐시티 프로브의 근거리 음장 측정에서의 오차 수치해석)

  • Kim, Suk-Jae;Jee, Suk-Kun;Suzuki, Hideo;Kim, Chun-Duck
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.3
    • /
    • pp.41-50
    • /
    • 1994
  • We studied an inherent error be caused by a measuring acoustic intensity using probe which can measure simultaneously the three-dimensional acoustic intensity. This three-dimensional intensity probe was constructed with four microphones, proposed by Suzuki et al. . In the computer simulation, we analyzed the nearfield measurement error with arbitary direction and each of axis direction on the ideal point source and the plate sound source which have finite size. From the results, in case of point source, we obtained accurate measurement below about 1dB when the distance of measurement was about 2.5 times with the distance among microphones in this probe. And in the case of plate sound source, the nearfield measurement error was decreased as the length of one side became above 0.02m, we obtained accurate measurement below about 1dB when the length of one side is 0.2m. The nearfield measurement error of finite size sound is small to ignore. Therefore this probe is useful to measure nearfield intensity.

  • PDF