• Title/Summary/Keyword: 방전현상

Search Result 372, Processing Time 0.028 seconds

Structure Analysis of Li-ion Battery Using Neutron Beam Source (중성자를 이용한 리튬이온 이차전지 전극 구조분석)

  • Kim, Chang-Seob;Park, Heon-Yong;Liang, Lianhua;Kim, Ji-Young;Seong, Baek-Seok;Kim, Keon
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.1
    • /
    • pp.20-24
    • /
    • 2007
  • Lithium ion secondary battery has been applied widely to portable devices, and has been studied for application to high power electric cell system such as power tool or hybrid electronic vehicle. The structure change of the electrodes materials occur when lithium ions move between electrodes. Neutron or X-rays can analyze the structure of electrode. The advantage of X-rays is convenient in test. However X-rays is scattered by electron cloud in atoms. Therefore, The elucidation for correct position of lithium is difficult with X-rays because lithium has small atomic weight. Neutron analysis techniques could solve this problem. In this review, We wish to discuss about structure analysis and the principle of structural characterization method using neutron beam source.

E-Beam 증착에 의해 제작된 다층형 Al-Mg 코팅층의 특성 관찰

  • Jeong, Jae-Hun;Yang, Ji-Hun;Park, Hye-Seon;Song, Min-A;Jeong, Jae-In
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.384-384
    • /
    • 2013
  • 본 연구에서는 e-beam 증착을 이용하여 Al, Mg 단일 금속으로 다층형 Al-Mg 코팅층을 제조하여 특성 분석 및 내식성을 평가하였다. Al-Mg 코팅층은 99.99%의 Al, 99.9%의 Mg grain을 사용하여 E-Beam 가열을 통해 냉연강판 위에 코팅하였다. 증발물질과 기판과의 거리는 48 cm이며, 기판은 세척을 실시한 후 진공 챔버에 장착하고 ~10-5 Torr 까지 진공배기를 실시하였다. 진공챔버가 기본 압력까지 배기되면 아르곤 가스를 주입하고 기판홀더에 800 V의 직류 전압을 인가하여 약 30분간 글로우 방전 청정을 실시하였다. 기판의 청정이 끝나면 아르곤 가스를 차단하고 코팅층의 구성형태에 따라 Al 또는 Mg을 코팅하였다. 다층형 Al-Mg 코팅층은 2층에서 최대 6층까지 제조하였으며 $3{\mu}m$의 두께를 기준으로 Al과 Mg 코팅층의 두께비가 각각 1:1 과 2:1이 되도록 코팅하였다. 6층 이상에서는 코팅층의 두께 제어가 쉽지 않기 때문에 층수는 6층으로 제한하였다.다층형 Al-Mg 코팅층을 주사전자현미경으로 관찰한 결과, Al-Mg 코팅층간의 계면을 관찰할 수 있었다. 또한 글로우방전분광기로 Al-Mg 코팅층을 관찰한 결과, Al과 Mg 코팅층이 균일한 다층 구조를 형성하고 있는 것을 확인할 수 있었다. 다층의 Al-Mg가 코팅된 강판을 염수분무시험을 통해서 내부식 특성을 확인하였다. Al-Mg 코팅 강판의 염수분무시험 결과, Al-Mg 코팅층의 층수가 증가할 수록 내부식 특성이 향상되는 것을 확인할 수 있었으며, 이러한 현상은 Al-Mg 코팅층이 다층으로 형성되어 있어 부식 생성물을 효과적으로 차단하여 강판의 부식을 방지한 것으로 판단된다.

  • PDF

다상포낙선검파법에 관한 연구

  • 이충웅
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.10 no.1
    • /
    • pp.18-26
    • /
    • 1973
  • In AM detection system, when the ratio of the frequency of the carrier to that of the modulating signal becomes less than a ratio of approximately 10:1, AM detectors become unable to detect the impressed signal in a satisfactory waveform. The failure of detecting such a super wide-band AM signal resulting from charging and discharging transient phenomena in associated diode circuit during the detecting of AM signal, has been a cause of limiting the channel capacity in AM or FM super multiplexing systems. This Paper presents the "Poly-phase Envelope Detection System" as a suitable method to solve the problem and the analyses of the system suggested. This system will make it possible to take the envelope out of the impressed AM signal to any desired degree of accuracy even when the ratio of the frequency of the carrier to that of the modulating signal approaches unity. Experiments were carried out to verify the validity of the theory of Poly-phase Envelope Detection System by adopting the frequency conversion method from among the two proposals.proposals.

  • PDF

A Scheme for Reuse of Residual Energy in a Multi-cell Battery System (다중전지 시스템에서 잔류 에너지의 재활용 방법)

  • Yun, Woong-Jin;Baek, Je-In
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.6
    • /
    • pp.21-27
    • /
    • 2009
  • As portable electronic systems being used more often, it becomes a more important issue to lengthen the lifetime of the power battery of the system, for instance, by developing batteries of a higher efficiency. A simple as well as practical method to lengthen the lifetime is to use multiple batteries that are connected in parallel. But in this paper we present a new idea in using multiple batteries, with which the residual energy of the battery can be used in the sense of recycling. The idea is based on a usual phenomenon that a battery cell that has been used until its voltage has dropped below a reference level may still have some residual energy, due to which the voltage can recover when the cell takes a rest for a while. As a practical realization scheme of this idea, a multi-cell configuration method with a cell selection switch is introduced, and its feasibility has been examined by performing experimental observations on the behavior of battery discharge. It has been found that the lifetime of an Alkaline primary battery cell can be lengthened approximately by one or two hours with the proposed method.

Fabrication and Characteristics of X-ray Position Detection Sensor (방사선 위치 검출센서의 제작 및 특성)

  • Park, Hyung-Jun;Kim, In-Su
    • Journal of IKEEE
    • /
    • v.19 no.4
    • /
    • pp.535-540
    • /
    • 2015
  • A microstrip gas chamber (MSGC), applied to digital radiography system, was designed and constructed. The microstrip electrodes were fabricated with Chrome(Cr.). by photolithography process on Silicon(Si) wafer and glass substrate. The width of anode and cathode electrodes was $10{\mu}m$, and $290{\mu}m$, respectively. The distance of the electrodes was $100{\mu}m$, and the active area was $50{\times}50mm^2$. And the number of anode was 80. The microstrip electrodes were damaged when discharges occurred over the 600 V of anode voltage. As the result of experiments. It detected the typical output signals of the pulse width, 20 ns, under the condition that the detecting gas was Ar(90%) + $CH_4$(10%), X-ray tube voltage was 42 kV, and tube current was 1 mA.

A Study on the Characteristics of Surface Flashover for PCPS (PCPS용 반도체 연면방전 특성 연구)

  • 김정달;정장근
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.87-95
    • /
    • 1999
  • A primary limitation of the awlication of New class of solid state high power, high speed electronic device, narrely, the Photo-Conductive Power Switch(PCPS) is that the switches flashover at the surlace under average awlied fields much less than the bulk breakdown field of the semiconductor in most cases. The only way overcome those problffi1 and has a workable compact solid state switch is to passivate the surlace by a solid state dielectric material. In this experirrentation, The voltage withstands of Silicon is to be severely degraded when operated in vacuum(10[kV/cm]) and the perlormance is improved when operated in air(30[kV/cm[), in SF6(80~100[kV/cm]). After the passivation, the device had a breakdown field in vacuum and air at a field as high as the unpassivated device in SF6. A experirrent results show passivated devices have excellent breakdown field. In this paper, We improved the main properties and mechanism of the silicon breakdown before and after passivation under high field. field.

  • PDF

Partial Discharge Phenomena with $SF_{6}$ Gas Pressures in Insulation Consisted of Insulation Paper and $SF_{6}$ Gas(II) ($SF_{6}$가스와 절연지의 절연계에서 가스압력에 따른 부분방전 현상(II))

  • Seon, Jong-Ho;Kim, Gwang-Hwa;Park, Jeong-Hu;Jo, Jeong-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.9
    • /
    • pp.430-435
    • /
    • 2002
  • The $SF_{6}$ gas insulated power equipments have the insulation systems which are composed of $SF_{6}$ gas and insulation paper. It is repored that their insulation abilities are influenced by the $SF_{6}$ gas gaps in those insulation systems and gas pressures. This paper describes partial discharge phenomena with $SF_{6}$ gas pressures in insulation system of $SF_{6}$ gas-insulation paper Specimens of $SF_{6}$ gas-insulation paper were prepared and aramid paper was used as insulation paper. Partial discharge inception voltages(PDIV) and breakdown voltages for the existence of $SF_{6}$ gas gaps were measured by short term tests with gas pressures. Also, average PD quantities and pulse counts, life times of each specimens were calculated from the results of long term aging tests with gas pressures. It was found that the $SF_{6}$ gas gaps decrease increasing rates of PDIV and brealdown voltages according to gas pressure increase and the insulation breakdown caused by the smaller PD quantities than 1[pC] at the high gas pressure of 300kPa is due to the increase of energy density with increase of gas pressure.

Proposal for safety operation of SC Bank (SC bank 안전운전을 위한 제안)

  • Joo, Jung-Kyu;Kang, Chang-Ik;Yun, Si-Young;Jung, Jae-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.186-191
    • /
    • 2004
  • 전력계통에서 역률개선을 위해 사용하는 전력용 콘덴서(이하 SC bank)는 전력계통의 운전상 전압 제어와 역율개선이라는 두가지 측면에서 매우 중요한 전력설비이다. 또한 최근에 전력산업 구조조정에 의해 발전분야가 분할되는 시점에서 SC bank의 역할의 중요성이 강조되고 있다. 본 논문에서는 SC의 고장원인이 무엇인지를 현장조사를 통해 수행하였다. 그 결과 SC bank를 구성하고 있는 리액터, 콘덴서, PT, 혹은 CT 흑은 방전코일의 열화원인이 대부분 차단기의 투입서지와 차단서지에 의해 발생되고 있음을 확인하였다 또한 기존의 보호시스템은 SC Bank의 보호에 적합하지 않음을 검토하였다 차단기 서지에 대한 대책으로는 투입시 전압영점투입과 중성점 저항기의 취부로 투입서지 및 차단서지를 효과적으로 감소되는 현상을 모의와 현장실측을 통해 확인하였다. 또한 기존의 보호방식이 과전류와 과전압 부족전압 혹은 CT와 PT를 이용한 차동방식에 의해 셀의 경련변화를 감지하고 있으나 이 경우 보호맹점이 존재하게 됨을 검토하였다. 이러한 보호상의 문제점을 보완하는 방법으로 SC bank는 임피던스가 늘 일정하는 점에 착안하여 전압과 전류를 이용하여 임피던스의 변화량을 감시하고, 또 한가지 방법은 SC bank의 운전특성상 무효전력만을 발생시킨다는 점에 착안하여 만일 유효전력 성분이 SC bank에서 감지된다면 소자의 이상이나 비정상적은 전류경로가 된다는 결론에 도달하고 유효전력감시를 통한 SC bank의 열화감지가 가능하다는 결론에 도달하였다. 본 논문에서 제안한 3가지의 방법, 즉, 첫째 영점투입차단기 채택, 둘째, 중성점 저항기의 도입, 셋째 새로운 보호방식에 의한 기존의 보호맹점의 보완을 제안하였다. 위의 새로운 제안을 현장에 적용하는 경우 제작사의 제작불량을 제외한 운전상의 SC bank의 문제점 및 고장빈도는 현저히 감소하게 될 것으로 사료된다.

  • PDF

A Study on the Outages Due to Voltage Expanding in Closing High Voltage Capacitor (고압 커패시터 투입시 전압확대에 따른 사고 사례 연구)

  • Cho, Nam-Hoon;Jung, Jum-Soo;Park, Yong-Woo;Ha, Bok-Nam;Lee, Hyung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.94-102
    • /
    • 2008
  • Capacitor switching is essential for the economic operation and proper voltage control of KOREA electric utility distribution system. Voltage transients produced by capacitor switching (around 2.0 per unit at substation and 2.5 or less per unit at customer site, and lasting less then 1[ms]) do not have the magnitude or duration to interfere with the operation of computers, but they do disrupt the operation of adjustable speed drivers. The result of our research, ASD manufacturers should learn from the computer industry and design products that will operate satisfactory In the electrical envelopment in which they will be placed. In this case history, the inductors on the input to ADSs in order to prevent nuisance tripping from capacitor switching(and other causes within the apartment) proved to be an effective, low-cost solution.

Modeling to Estimate the Cycle Life of a Lithium-ion Battery (리튬이온전지의 사이클 수명 모델링)

  • Lee, Jaewoo;Lee, Dongcheul;Shin, Chee Burm;Lee, So-Yeon;Oh, Seung-Mi;Woo, Jung-Je;Jang, Il-Chan
    • Korean Chemical Engineering Research
    • /
    • v.59 no.3
    • /
    • pp.393-398
    • /
    • 2021
  • In order to optimize the performance of a lithium-ion battery, a performance prediction modeling technique that considers various degradation factors is required. In this work, mathematical modeling was carried-out to predict the change in discharging behavior and cycle life, taking into account the cycle aging of lithium-ion batteries. In order to validate the modeling, a cycling test was performed at the charge/discharge rate of 0.25C, and discharging behavior was measured through RPT (Reference Performance Test) performed at 30 cycle intervals. The accuracy of cycle life prediction was improved by considering the break-in mechanism, one of the phenomena occurring in the BOL (beginning of life), in the model for predicting the cycle life of lithium-ion batteries. The predicted change in cycle life based on the model was in good agreement with the experimental results.