• Title/Summary/Keyword: 방사화분석

Search Result 548, Processing Time 0.024 seconds

Chronic HBV Infection in Children: The histopathologic classification and its correlation with clinical findings (소아의 만성 B형 간염: 새로운 병리조직학적 분류와 임상 소견의 상관 분석)

  • Lee, Seon-Young;Ko, Jae-Sung;Kim, Chong-Jai;Jang, Ja-June;Seo, Jeong-Kee
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.1 no.1
    • /
    • pp.56-78
    • /
    • 1998
  • Objective: Chronic hepatitis B infection (CHB) occurs in 6% to 10% of population in Korea. In ethinic communities where prevalence of chronic infection is high such as Korea, transmission of hepatitis B infection is either vertical (ie, by perinatal infection) or by close family contact (usually from mothers or siblings) during the first 5 years of life. The development of chronic hepatitis B infection is increasingly more common the earlier a person is exposed to the virus, particularly in fetal and neonatal life. And it progress to cirrhosis and hepatocellular carcinoma, especially in severe liver damage and perinatal infection. Histopathology of CHB is important when evaluating the final outcomes. A numerical scoring system which is a semiquantitatively assessed objective reproducible classification of chronic viral hepatitis, is a valuable tool for statistical analysis when predicting the outcome and evaluating antiviral and other therapies. In this study, a numerical scoring system (Ludwig system) was applied and compared with the conventional histological classification of De Groute. And the comparative analysis of cinical findings, family history, serology, and liver function test by histopathological findings in chronic hepatitis B of children was done. Methods: Ninety nine patients [mean age=9 years (range=17 months to 16 years)] with clinical, biochemical, serological and histological patterns of chronic HBV infection included in this study. Five of these children had hepatocelluar carcinoma. They were 83 male and 16 female children. They all underwent liver biopsies and histologic evaluation was performed by one pathologist. The biopsy specimens were classified, according to the standard criteria of De Groute as follows: normal, chronic lobular hepatitis (CLH), chronic persistent hepatitis (CPH), mild to severe chronic active hepatitis (CAH), or active cirrhosis, inactive cirrhosis, hepatocellular carcinoma (HCC). And the biopsy specimens were also assessed and scored semiquantitatively by the numerical scoring Ludwig system. Serum HBsAg, anti-HBs, HBeAg, anti-HBe, anti-HBc (IgG, IgM), and HDV were measured by radioimunoassays. Results: Male predominated in a proportion of 5.2:1 for all patients. Of 99 patients, 2 cases had normal, 2 cases had CLH, 22 cases had CPH, 40 cases had mild CAH, 19 cases had moderate CAH, 1 case had severe CAH, 7 cases had active cirrhosis, 1 case had inactive cirrhosis, and 5 cases had HCC. The mean age, sex distribution, symptoms, signs, and family history did not differ statistically among the different histologic groups. The numerical scoring system was correlated well with the conventional histological classification. The histological activity evaluated by both the conventional classification and the scoring system was more severe as the levels of serum aminotransferases were higher. In contrast, the levels of serum aminotransferases were not useful for predicting the degree of histologic activity because of its wide range overlapping. When the histological activity was more severe and especially the cirrhosis more progressing, the prothrombin time was more prolonged. The histological severity was inversely related with the duration of seroconversion of HBeAg. Conclusions: The histological activity could not be accurately predicted by clinical and biochemical findings, but by the proper histological classification of the numerical scoring system for the biopsy specimen. The numerical scoring system was correlated well with the conventional histological classification, and it seems to be a valuable tool for the statistical analysis when predicting the outcome and evaluating effects of antiviral and other therapies in chronic hepatitis B in children.

  • PDF

CComparative evaluation of the methods of producing planar image results by using Q-Metrix method of SPECT/CT in Lung Perfusion Scan (Lung Perfusion scan에서 SPECT-CT의 Q-Metrix방법과 평면영상 결과 산출방법에 대한 비교평가)

  • Ha, Tae Hwan;Lim, Jung Jin;Do, Yong Ho;Cho, Sung Wook;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.90-97
    • /
    • 2018
  • Purpose The lung segment ratio which is obtained through quantitative analyses of lung perfusion scan images is calculated to evaluate the lung function pre and post surgery. In this Study, the planar image production methods by using Q-Metrix (GE Healthcare, USA) program capable of not only quantitative analysis but also computation of the segment ratio after having performed SPECT/CT are comparatively evaluated. Materials and Methods Lung perfusion scan and SPECT/CT were performed on 50 lung cancer patients prior to surgery who visited our hospital from May 1, 2015 to September 13, 2016 by using Discovery 670(GE Healthcare, USA) equipment. AP(Anterior Posterior)method that uses planar image divided the frontal and rear images into three rectangular portions by means of ROI tool while PO(Posterior Oblique)method computed the segment ratio by dividing the right lobe into three parts and the left lobe into two parts on the oblique image. Segment ratio was computed by setting the ROI and VOI in the CT image by using Q-Metrix program and statistically analysis was performed with SPSS Ver. 23. Results Regarding the correlation concordance rate of Q-Metrix and AP methods, RUL(Right upper lobe), RML(Right middle lobe) and RLL(Right lower lobe) were 0.224, 0.035 and 0.447. LUL(Left upper lobe) and LLL(Left lower lobe) were found to be 0.643 and 0.456, respectively. In the PO method, the right lobe were 0.663, 0.623 and 0.702, respectively, while the left lobe were 0.754 and 0.823. When comparison was made by using the Paired sample T-test, Right lobe were $11.6{\pm}4.5$, $26.9{\pm}6.2$ and $17.8{\pm}4.2$, respectively in the AP method. Left lobe were $28.4{\pm}4.8$ and $15.4{\pm}5.6$. The right lobe of PO had values of $17.4{\pm}5.0$, $10.5{\pm}3.6$ and $27.3{\pm}6.0$, while the left lobe had values of $21.6{\pm}4.8$ and $23.1{\pm}6.6$, thereby having statistically significant difference in comparison to the Q-Metrix method for each of the lobes (P<0.05). However, there was no statistically significant difference in Right middle lobe (P>0.05). Conclusion The AP method showed low concordance rate in correlation with the Q-Metrix method. However, PO method displayed high concordance rate overall. although AP method had significant differences in all lobes, there was no significant difference in Right middle lobe of PO method. Therefore, at the time of production of lung perfusion scan results, utilization of Q-Metrix method of SPECT/CT would be useful in computation of accurate resultant values. Moreover, it is deemed possible to expect obtain more practical sectional computation result values by using PO method at the time of planar image acquisition.

Green Spaces in the Urban Peripheries of Metropole Regions for Sustainable Development - Focused on Berlin, Milano and Seoul - (지속가능한 발전을 위한 대도시 외연부 녹지 활용 사례연구 - 베를린, 밀라노, 서울을 대상으로 -)

  • Hoh, Yun Kyeong;Chae, Jin-Hae
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.46 no.1
    • /
    • pp.72-85
    • /
    • 2018
  • This study focused on cases that led sustainable urban development through the construction and utilization of organic greenery systems linking green spaces of urban peripheries with metropolitan areas. To that end, Berlin - Brandenburg's regional parks in Germany and Milan's Raggi Verdi, a radial green axis project, in Italy were selected for analysis as case studies. As frameworks for this analysis, this study has established existing infrastructure accessibility and linkage, recycling and cooperative management. The results of the case study analysis are as follows: First, the specialized spatial strategy based on the individuality of the green space outside the city rather than a uniform landscape was used as the foundation of the sustainable development plan. Second, physical linkage from the center of the city to the periphery contributed to the sustainable development of the overall metropolis by improving the economic value of the surrounding area as well as ecological and environmental values. Third, the central management system was established to reduce the administrative inconvenience caused by multiple administrative districts in the green space of urban periphery. The implications of applying the above results to Seoul, Korea are as follows. First, it is necessary to establish a differentiation strategy by re-establishing the identity of a green landscape in the urban periphery, because the green spaces of Seoul's periphery are dispersed and mostly have a repetitious mountain landscape. Also, it is necessary to actively link peripheral mountains and urban green areas to create ecological value and economic value, and ultimately to help the sustainable development of the city. Finally, building an integrated management system is required to solve fragmented green space management departments in most of the urban periphery's green spaces. In conclusion, this study shows the significant possibility that the sustainable development of a metropolis can be derived from the utilization, linkage, and management of the green space in the urban peripheries, which is extraordinary compared to normal centralized urban development.

Development and Application of the Slope Management Program in Urban Area (대도시 사면관리프로그램 개발 및 적용)

  • Kim, Kyeong-Su;Chae, Byung-Gon;Cho, Yong-Chan;Lee, Choon-Oh;Song, Young-Suk
    • The Journal of Engineering Geology
    • /
    • v.17 no.1 s.50
    • /
    • pp.15-25
    • /
    • 2007
  • In general, the life and asset casualties that occur due to landslide or slope failure in urban areas are larger than that in rural areas. In order to reduce the casualties, a slope management program is necessary to categorize slopes based on properties and to manage them systematically. The slope management system is the establishment of the data base for the geological and geotechnical factor according to slope stability, and the utilization of the data base to manage slopes. The suitable system must develop to slopes in urban area through the survey, analysis and evaluation process. Based on the above necessity, the slope management program which is applicable to slope management in an urban area has been developed at Hwangryung Mt. in Busan as a target area. The developed slope management program has various functions such as slope ID number of each slope or sub-region of a mountain, making a slope data sheet, analysis and grouping of slope stability, and establishment of a data base. The slope management program is constructed by use of GIS, and the survey, test and analysis data according to all slopes can be input and edited into the program. The program can also be utilized practically by end users due to the convenient input, edition printing, management and operation of slope data. Therefore, the slope management system has been established on the application of the developed program in Busan which is located in slope area. As the system is widely applied to other cities, the slope in urban area can be managed systematically and the slope hazards can be minimized.

Correlation between Semiquantitative Myocardial Perfusion Score and Absolute Myocardial Blood Flow in $^{13}N-Ammonia$ PET ($^{13}N$-암모니아 PET에서 반정량적 심근관류 점수와 절대적 심근혈류량의 상관관계)

  • Lee, Byeong-Il;Kim, Kye-Hun;Kim, Jung-Young;Kim, Su-Jin;Lee, Jae-Sung;Min, Jung-Joon;Song, Ho-Chun;Bom, Hee-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.194-200
    • /
    • 2007
  • Purpose: $^{13}N$-ammonia is a well known radiopharmaceutical for the measurement of a myocardial blood flow (MBF) non-invasively using PET-CT. In this study, we investigated a correlation between MBF obtained from dynamic imaging and myocardial perfusion score (MPS) obtained from static imaging for usefulness of cardiac PET study. Methods: Twelve patients (11 males, 1 female, $57.9{\pm}8.6$ years old) with suspicious coronary artery disease underwent PET-CT scan. Dynamic scans (6 min: $5\;sec\;{\times}\;12,\;10\;sec\;{\times}\;6,\;20\;sec\;{\times}\;3,\;and\;30\;sec\;{\times}\;6$) were initiated simultaneously with bolus injection of 11 MBq/kg $^{13}N-ammonia$ to acquire rest and stress image. Gating image was acquired during 13 minutes continuously. Nine-segment model (4 basal walls, 4 mid walls, and apex) was used for a measurement of MBF. Time activity curve of input function and myocardium was extracted from ROI methods in 9 regions for quantification. The MPS were evaluated using quantitative analysis software. To compare between 20-segment model and 9-segment model, 6 basal segments were excluded and averaged segmental scores were used. Results: There are weak correlation between MBF (rest, 0.18-2.38 ml/min/g; stress, 0.40-4.95 ml/min/g) and MPS (rest 22-91%, stress, 14-90%), however the correlation coefficient between corrected MBF and MPS in rest state was higher than stress state (rest r=0.59; stress r=0.80). As a thickening increased, correlation between MBF and MPS also showed good correlation at each segments. Conclusions: Corrected and translated MPS as its characteristics using $^{13}N$-ammonia showed good correlation with absolute MBF measured by dynamic image in this study. Therefore, we showed MPS is one of good indices which reflect MBF. We anticipate PET-CT could be used as useful tool for evaluation of myocardial function in nuclear cardiac study.

Leaching Properties on Waste Form with Garnet Structure (석류석 구조를 가진 고화체의 용출 특성)

  • Chae Soo-Chun;Jang Young-Nam;Bae In-Kook;Ryu Kyung-Won;Ioudintseva T.S.;Yudintsev S.V.
    • Economic and Environmental Geology
    • /
    • v.39 no.2 s.177
    • /
    • pp.181-190
    • /
    • 2006
  • Garnet has been suggested as one of the most promising material for the immobilization of radionuclide in high level waste. But data on its chemical durability are sufficiently available. Accordingly, Gd and Ce garnets were synthesized as imitators for $Pu^{3+}\;and\;Pu^{4+}$ were synthesized, and their leaching rates, the parameters of the chemical durability were measured by changing the conditions. In distilled water, the ranges of leaching rates of Gd and Ce were $1.2{\times}10^{-4}{\sim}4.6{\times}10^{-6}g/m^2/day\;and\;7.5{\times}10^{-5}{\sim}1.8{\times}10^{-7}g/m^2/day$, respectively. A comparison with previous data suggests that the chemical durabilities of garnets synthesized from this study are superior to those of other waste forms. Additional leaching experiments were performed with 0.01M-HCl and 0.01M-NaOH solutions to see Gd and Ce leaching at acidic and alkalinity conditions. In 0.01 H-HCl solution, the ranges of leaching rates of Gd and Ce were $2.5{\times}10^{-1}{\sim}6.9{\times}10^{-3}g/m^2/day\;and\;3.7{\times}10^{-1}{\sim}3.1{\times}10^{-3}g/m^2/day$, respectively, while were $3.1{\times}10^{-4}{\sim}1.3{\times}10^{-6}g/m^2/day\;and\;1.8{\times}10^{-3}{\sim}0g/m^2/day$, respectively in 0.01M-NaOH solution. It is believed that leaching data can be used in understanding chemical durabilities of waste from garnets in acidic and alkaline conditions.

A Study on analysis of contrasts and variation in SUV with the passage of uptake time in 18F-FDOPA Brain PET/CT (18F-FDOPA Brain PET/CT 검사의 영상 대조도 분석 및 섭취 시간에 따른 SUV변화 고찰)

  • Seo, Kang rok;Lee, Jeong eun;Ko, Hyun soo;Ryu, Jae kwang;Nam, Ki pyo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.69-74
    • /
    • 2019
  • Purpose $^{18}F$-FDOPA using amino acid is particularly attractive for imaging of brain tumors because of the high uptake in tumor tissue and the low uptake in normal brain tissue. But, on the other hand, $^{18}F$-FDG is highly uptake in both tumor tissue and normal brain tissue. The purpose of study is to evaluate comparison of contrasts in $^{18}F$-FDOPA Brain PET/CT and $^{18}F$-FDG Brain PET/CT and to find out optimal scan time by analysis of variation in SUV with the passage of uptake time. Materials and Methods A region of interest of approximately $350mm^2$ at the center of the tumor and cerebellum in 12 patients ($51.4{\pm}12.8yrs$) who $^{18}F$-FDG Brain PET/CT and $^{18}F$-FDOPA Brain PET/CT were examined more than once each. The $SUV_{max}$ was measured, and the $SUV_{max}$ ratio (T/C ratio) of the tumor cerebellum was calculated. In the analysis of SUV, T/C ratio was calculated for each frame after dividing into 15 frames of 2 minutes each using List mode data in 25 patients ($49.{\pm}10.3yrs$). SPSS 21 was used to compare T/C ratio of $^{18}F$-FDOPA and T/C ratio of $^{18}F$-FDG. Results The T/C ratio of $^{18}F$-FDOPA Brain PET/CT was higher than the T/C ratio of $^{18}F$-FDG Brain, and show a significant difference according to a paired t-test(t=-5.214, p=0.000). As a result of analyzing changes in $SUV_{max}$ and T/C ratio, the peak point of $SUV_{max}$ was $5.6{\pm}2.9$ and appeared in the fourth frame (6 to 8 minutes), and the peak of T/C ratio also appeared in the fourth frame (6 to 8 minutes). Taking this into consideration and comparing the existing 10 to 30 minutes image and 6 to 26 minutes image, the $SUV_{max}$ and T/C ratio increased by 0.2 and 0.1 each, compared to the 10 to 30 minutes image for 6 to 26 minutes image. Conclusion From this study, $^{18}F$-FDOPA Brain PET/CT is effective when reading the image, because the T/C ratio of $^{18}F$-FDOPA Brain PET/CT was higher than T/C ratio of $^{18}F$-FDG Brain PET/CT. In addition, in the case of $^{18}F$-FDOPA Brain PET/CT, there was no difference between the existing 10 to 30 minutes image and 6 to 26 minutes image. Through continuous research, we can find possibility of shortening examination time in $^{18}F$-FDOPA Brain PET/CT. Also, we can help physician to accurate reading using additional scan data.

Synthesis of Garnet in the Ca-Ce-Gd-Zr-Fe-O System (Ca-Gd-Ce-Zr-Fe-O계에서의 석류석 합성 연구)

  • Chae Soo-Chun;Jang Young-Nam;Bae In-Kook;Yudintsev S.V.
    • Economic and Environmental Geology
    • /
    • v.38 no.2 s.171
    • /
    • pp.187-196
    • /
    • 2005
  • Structural sites which cations can occupy in garnet structure are centers of the tetrahedron, octahedron, and distorted cube sharing edges with the tetrahedron and octahedron. Among them, the size of cation occuping at tetrahedral site (the center of tetrahedron) is closely related with the size of a unit cell of garnet. Accordingly, garnet containing iron with relative large ionic radii in tetrahedral site can be considered as a promising matrix for the immobilization of the elements with large ionic radii, such as actinides in radioactive wastes. We synthesized several garnets with the batch composition of $Ca_{1.5}GdCe_{0.5}ZrFeFe_3O_{12}$, and studied their properties and phase relations under various conditions. Mixed samples were fabricated in a pellet form under a pressure of $200{\~}400{\cal}kg/{\cal}cm^2$ and were sintered in the temperature range of $1100\~1400^{\circ}C$ in air and under oxygen atmospheres. Phase identification and chemical analysis of synthesized samples were conducted by XRD and SEM/EDS. In results, garnet was obtained as the main phase at $1300^{\circ}C$, an optimum condition in this system, even though some minor phases like perovskite and unknown phase were included. The compositions of garnet and perovskite synthesized from the batch composition of $Ca_{1.5}GdCe_{0.5}ZrFeFe_3O_{12}$ were ranged $[Ca_{l.2-1.8}Gd_{0.9-1.4}Ce_{0.3-0.5}]^{VIII}[Zr_{0.8-1.3}Fe_{0.7-1.2}]^{VI}[Fe_{2.9-3.1}]^{IV}O_{12}$ and $Ca_{0.1-0.5}Gd_{0.0-0.8}Ce_{0.1-0.5}\;Zr_{0.0-0.2}Fe_{0.9-1.1}O_3$, respectively. Ca content was exceeded and Ce content was depleted in the 8-coordinated site, comparing to the initial batch composition. This phenomena was closely related to the content of Zr and Fe in the 6-coordinated site.

The Study of CYFRA 21-1 and Epidermal Growth Factor Receptor Levels in Cancer Tissue of Bronchogenic Carcinoma Patients (폐암환자의 암조직내 CYFRA 21-1과 Epidermal Growth Factor Receptor의 측정치에 대한 연구)

  • 김대연;김송명
    • Journal of Chest Surgery
    • /
    • v.30 no.9
    • /
    • pp.854-861
    • /
    • 1997
  • CYPRA 21-1 is known to be a cytokeratin 19 fragment, and it can be detected by using two specific monoclonal antibodies (KS 19-1 and BM 19-21) and can be clinically applied as a useful circulating tumor marker The epidermal growth factor receptor (EGF-R) expression was evaluated and characterized by its tyrosine protein kinase activity and by its ligand-stimulated autophosphorylation, a property shared with other peptide growth factor receptors. Autocrine or para'urine action was initiated by a growth factor, or by a transforming growth factor o, which had an extensive homology with EGP and which also stimulated tyrosine kinase activity on the EGF-R. The CYFRA 21-1 and the EGF-R levels in 30 patients with primary lung tumors were investigated. There were 24 patients with squamous cell carcinomas and 6 patients with adenocarcinomas. Specimen 5 mm3 in size were sampled at three different locations ; the main lesion, the boundary between the lesion and the unaffected tissue, and the unaffected tissue of the patients. The results were as follows 1. The CYPRA 21-1 concentration in the cancer boundary, the most malignant region,(348.6 : 89.9 ng/ml) was the lowest value. The CYFRA 21-1 concentration in unaffected tissue,(718.4$\pm$77.8 ng/ml) was higher than that in the main lesion. which had intact cellularity. 2. The EGF-R concentration in the main lesion was higher than that in the unaffected tissue, and the EGF-R concentration in a squamous cell cacinoma was higher than that in an adenocarcinoma. also, the EGF-R concentration in the cancer b undary was highest at stage 1, ll. The EGF-R concentration was higher in the main cancer lesion that in the unaffected tissue at stage 111, IV. 3. The CYFRA 21-1 was a cytoplasmic skeleton and the EGF-R was a cell-wall component; there was no correlation. In conclusion, CYFRA 21-1 was abundant in the cytoplasm but had a higher concentration in the unaffected tissue than in the main cancer lesion. The CYFRA 21-1 concentration of the tissue did not reflect the amount of cancer activity, the EGP-R was located in the cell membrane, the level of tissue that reflects cancer activity, so the main cancer lesion had a higher concentration than the unaffected tissue. CYFRA 21-1 is not a useful tumor maker at the tissue level. Because the EGF-R concentration re(looted the cancer activity, its a useful tumor marker for lung cancer.

  • PDF

Cooling Time Determination of Spent Nuclear Fuel by Detection of Activity Ratio $^{l44}Ce /^{l37}Cs$ (방사능비 $^{l44}Ce /^{l37}Cs$ 검출에 의한 사용후핵연료 냉각기간 결정)

  • Lee, Young-Gil;Eom, Sung-Ho;Ro, Seung-Gy
    • Nuclear Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.237-247
    • /
    • 1993
  • Activity ratio of two radioactive primary fission products which had sufficiently different half-lives was expressed as functions of cooling time and irradiation histories in which average burnup, irradiation time, cycle interval time and the dominant fissile material of the spent fuel were included. The gamma-ray spectra of 36 samples from 6 spent PWR fuel assemblies irradiated in Kori unit-1 reactor were obtained by a spectrometric system equipped with a high purity germanium gamma-ray detector. Activity ratio $^{l44}$Ce $^{l37}$Cs, analyzed from each spectrum, was used for the calculation of cooling time. The results show that the radioactive fission products $^{l44}$Ce and $^{l37}$Cs are considered as useful monitors for cooling time determination because the estimated cooling time by detection of activity ratio $^{l44}$Ce $^{l37}$Cs agreed well with the operator declared cooling time within relative difference of $\pm$5 % despite the low counting rate of the gamma-ray of $^{l44}$Ce (about 10$^{-3}$ count per second). For the samples with several different irradiation histories, the determined cooling time by modeled irradiation history showed good agreement with that by known irradiation history within time difference of $\pm$0.5 year. From this result, it would be expected to be possible to estimate reliably the cooling time of spent nuclear fuel without the exact information about irradiation history. The feasibility study on identification of and/or sorting out spent nuclear fuel by applying the technique for cooling time determination was also performed and the result shows that the detection of activity ratio $^{l44}$Ce $^{l37}$Cs by gamma-ray spectrometry would be usefully applicable to certify spent nuclear fuel for the purpose of safeguards and management in a facility in which the samples dismantled or cut from spent fuel assemblies are treated, such as the post irradiation examination facility.mination facility.

  • PDF