Near-Field Analysis of Vehicle LF Antennas for Estimating the Reading Range of a Smart Key (스마트 키 인식 거리 예측을 위한 차량 LF 안테나의 Near-Field 분석)

  • Kim, Heeyoung;Byun, Gangil;Seong, Jaeyong;Jung, Hankil;Choo, Hosung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.7
    • /
    • pp.671-677
    • /
    • 2013
  • In this paper, we propose a method of near-field analysis for vehicle LF antennas in order to estimate the accurate reading range of a smart key. The LF antenna consists of a ferrite core and a conducting wire which is coated with polyethylene for insulation, and it is mounted at the rear bumper frame of a commercial vehicle. The reading range of a smart key is measured at nine azimuthal directions distributed around the rear bumper, and then, the received power at each maximum reading range is measured by using a spectrum analyzer. The measurement shows that the maximum reading range exists between 1.38 m and 1.53 m, and the radiated power is between -83.6 dBmW and -75.0 dBmW. We further conducted EM simulation to estimate the reading range and the received power under the same condition that we applied for the measurement. The results demonstrate that an accurate reading range and received power can be achieved by simulation.

The Image Distortion Analysis of Levin-tube tip by Patient position and Incidence Angle when taking Mobile Chest AP Projection (Mobile Chest AP 검사 시 환자자세와 입사각도에 따른 Levin-tube tip의 영상왜곡 분석)

  • Lee, Jinsoo;Park, Hyonghu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.467-471
    • /
    • 2015
  • This study's purpose is improve image quality to keep accurate tube angle in order to recognize distortion degree conditions by patient's position or tube angle and to provide exact clinical informations when taking chest AP projection for patient which have L-tube in stomach. The experimental equipment was ELMO-T6S by SHIMADZU corporation, then we put L-tube which attached 1 mm gap scales ruler on chest phantom surface. The experiment set by 90 kVp, 4 mAs, 120 cm distance. Each phantom position which changed supine, 30degree, 45degree, 60degree on the table exposured direct, ${\pm}5degree$, ${\pm}10degree$, ${\pm}15degree$ to head and feet directions. As a result, L-tube tip's position was changed by patient's position and tube angle. When patient's position is supine, tip's position change was lower than 30degree, 45degree, 60degree. We have to adjust patient's position or tube angle in order to occur image distortion by fault tube angle when confirming correct position L-tube tip through chest x-ray. Also, Radiological technologist try to make accurate evaluation index for satisfied L-tube insertion.

Analysis on Pool Temperature Variation along Pool Water Management System Operation in Research Reactor (연구용원자로에서 수조수관리계통 운전에 따른 수조수 온도 해석)

  • Choi, Jungwoon;Lee, Sunil;Park, Ki-Jung;Seo, KyoungWoo
    • Transactions of the KSME C: Technology and Education
    • /
    • v.5 no.2
    • /
    • pp.135-143
    • /
    • 2017
  • The domestic unique research reactor, HANARO (Hi-flux Advanced Neutron Application ReactOr), has been constructed with the open-pool, the core is submerged in, for the multi-purpose neutron application. The reactor has a primary cooling system to remove the fission heat from the core and its connected fluidic systems. Since the works are required at the reactor pool top as a characteristic of the research reactor, the radiation shall be minimized with the operation of the hot water layer system to avoid unnecessary radiation exposure on the workers during work at the pool top. Moreover, the pool water management system is connected to the reactor pool to maintain the pool temperature below $50^{\circ}C$ to minimize the uprising radioactive gas or impurity from the colder pool bottom. For the efficient flow rate of the PWMS, the thermal capacity of heat exchanger is selected with 260 kW in the normal operation condition. In this paper, the modeling is formulated to figure out whether or not each pool temperature maintains below the temperature limit and the calculation results show that the designed PWMS heat exchanger has enough capacity with the design margin regardless of the reactor operation mode.

Removal of Cobalt Ion by adsorbing Colloidal Flotation (흡착 교질 포말부선법에 의한 Cobalt Ion의 제거)

  • 정인하;이정원
    • Resources Recycling
    • /
    • v.7 no.3
    • /
    • pp.3-10
    • /
    • 1998
  • Simulated waste liquid containing 50 ppm cobalt ion was treated by adsorbing colloidal flotation using Fe(III) or Al(IlI) as flocclant and a sodium lamyl sulfate as a collector. Parameters such as pH, surfactant concentration, Fe(III) or Al(III) concentration, gas flow rate, etc., W앙e considered. The flotation with Fe(III) showed 99.8% removal efficiency of cohalt on the conditions of initial cobalt ion concentration 50 ppm, pH 9.5, gas flow rate 70 ml/min, and flotation time 30 min. When the waste solution, was treated with 35% $H_2O_2$ prior to adsorbing colloidal flotation, the optimal pH for removing cobalt shifted m to weak alkaline range and flotation could be applied in wider range of pH as compared to non-use of $H_2O_2$. Additional use of 20 ppm Al(III) after precipitation of 50 ppm Co(II) with 50 ppm Fe(III) made the optimal pH range for preferable flotation w wider. Foreign ions such as, $NO_3^-$, $SO_4^{2-}$, $Na^+$, $Ca^{2+}$ were adopted and their effects were observed. Of which sulfate ion was f found to be detrimental to removal of cob퍼t ion by flotation. Coprecipitation of Co ion with Fe(III) and Al(III) resulted in b better removal efficiency of cobalt IOn 피 the presence of sulfate ion.

  • PDF

Removal of Cobalt Ions by Precipitate Foam Flotation (침전 포말부선법에 의한 Cobalt Ion의 제거)

  • 정인하;이정원
    • Resources Recycling
    • /
    • v.7 no.3
    • /
    • pp.11-16
    • /
    • 1998
  • Simulated waste liquid containing 50 ppm cobalt ion was t$\xi$sted by precipitate flotation using a sodium lauryl sulfate as a c collector. The effects of initial cobalt ion concentration, pH, surfactant concentration, flotation time, gas flow rate and foreign i ions on removal efficiency of cobalt ion were studied. Pretreatment of the waste liquid with 35% $H_2O_2$, prior to precipitate f flotation made shin of optimal flotation pH from the strong alkalinity to weak alkaline range and made a favorable flotation of c cobalt ion in wide range of pH. For the result of this experiment, 99.8% removal efficiency was obtained on the conditions of initial coball ion concentration 50 ppm, pH 9.5 gas flow rate 70 mllmin, flotation time 30 min. The simulate ion was fanned t to be the most harmful ion against removal of cobalt by precipitate flotation of the species which were tested The presence of 0.1 M of $SO_4^{2-}$ ion decreased remo,때 $\xi$폐iciency of cobalt to 90% while the cobalt were almost entirely removed in the a absence of sulfate ion.

  • PDF

Reducing Methods of Patient's Exposed Dose Using Auto Exposure Control System in Digital Radiography (디지털 방사선장비에서 자동노출제어 사용 시 환자피폭선량 감소 방안)

  • Shin, Seong-Gyu
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.111-122
    • /
    • 2013
  • This study was carried out to reduce patient dose through focus-detector distance, kilovoltage, and a combination of copper filters. In the C, L-spine lateral, Skull AP views were obtained by making changes of 60-100 kV in tube voltage and of 100-200 cm in focus-detector distance and by adding a copper filter when using an auto exposure control device in the digital radiography equipment. The incident dose showed 90 kV, 0.3 mmCu in C-spine lateral with 0.06 mGy under the condition of 200 cm; 100 kV, 0.3 mmCu with 0.40 mGy under the condition of 200 cm and 90 kV 0.3 mmCu in Skull AP with the lowest value of 0.24 mGy under the condition of 140 cm. It was observed that entrance surface dose decreased the most when was increased by 150 cm, 70 kV (C-spine lateral), 81 kV (L-spine lateral). It was also found out that as the between the focus-detector increased in the expansion of the video decreased but the difference was not significant when the distance was 180 cm or more. Skull AP showed the most reduction in the entrance surface dose when the tube voltage was changed by 80 kV, 0.1 mmCu, and 120 cm. Therefore, when using the automatic exposure control device, it is recommended to use the highest tube voltage if possible and to increase focus-detector distance at least by 150~200 cm in wall and 120~140 cm in table in consideration of the radiotechnologist's physical conditions, and to combine 0.1~0.3 mmCu and higher filters. It is thus expected to reduce patient dose by avoiding distortion of images and reducing the entrance surface dose.

Dose Evaluation of Childhood Leukemia in Total Body Irradiation (소아백혈병의 전신방사선조사시 선량평가)

  • Lee, Dongyeon;Ko, Seongjin;Kang, Sesik;Kim, Changsoo;Kim, Donghyun;Kim, Junghoon
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.4
    • /
    • pp.259-264
    • /
    • 2013
  • Total body irradiation in the treatment of childhood leukemia, which is one of the pre-treatment with stem cell transplantation is being used, the current organization using compensators are treated. However, under the terms of the compensator organization long-term impact on the human body, it is difficult to assess directly. In this study, we use the mathematical simulation of radiation exposures body energy and the distance to the crew and the patient (source surface distance, SSD), and patients with tissue compensators change of the distance along the body of the organ doses were evaluated. As a result, the surface dose of energy 4 MV, SSD 280 cm, tissue compensators and the patient when the distance 30 cm 5.84 G / min showed the highest levels. In addition, patients with tissue compensators and the distance apart when 30 cm TBI represents the ideal dose distribution was found.

A Numerical Study on the Generation and Propagation of Intake Noise in the Reciprocating Engine (엔진 흡기계의 소음발생 및 전파에 관한 수치연구)

  • 김용석;이덕주
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.10a
    • /
    • pp.65-70
    • /
    • 1996
  • 엔진소음을 소음특성에 따라 분류하면 공력소음(Aerodynamic Noise), 연소소음(Combustion Noise), 기계적인 소음(Mechanical Noise)으로 나눌 수 있으며 소음원의 종류에 따라 분류하면 배기계소음(Exhaust System Noise)으로 나눌 수 있으며 소음원의 종류에 따라 분류하면 배기계소음(Exhaust System Noise), 흡기계소음(Intake System Noise), 냉각계소음(Cooling System Noise), 엔진표면소음(Engine System Noise)등으로 분류할 수 있다. 이러한 여러소음중 엔진 내부의 유동에 의한 흡배기계통으로의 소음방출은 자동차 실 내외 소음의 중요한 문제로 대두되는데, 이를 줄이기 위해 그 동안 소음기 등의 서브시스템의 형태와 그 위치조정에 관한 연구가 수행되어 왔다. 그러나 이것이 비용 또는 성능에 영향을 미치므로 본질적인 소음원을 규명해 내는 것이 필요하게 되었다. 흡배기계의 소음은 엔진의 흡입, 배기행 정시 피스톤의 운동에 의해 팽창 및 압축파 형태의 압력파(pressure wave)로 발생하게 되고, 밸브근방에서는 유동의 박리(separation)에 의해 발생하게 된다. 소음기 등의 서브시스템에서도 유동의 박리에 의해 발생하게 되며 특히 배기행정시 발생하는 압력파는 비선형영역에 있게된다. 흡기소음은 배기에 비해 그 크기가 작아서 그동안 등한시 되어왔으나 이것이 소비자의 불평요인으로 작용하므로써 이에 대한 연구도 활발히 수행되어야 한다. Bender, Bramer[1]는 흡배기계 소음의 외부 방사에 관하여 전반적으로 기술하였고 Sierens등[2]은 흡기계에서 1차원 MOC(Method of Characteristics)방법으로 비정상 유동해석을 하고 실험결과와 비교하였다. J.S.Lamancusa 등[3]은 흡기 소음원을 실험을 통해 예측하였고, 흡기소음도 비선형 거동을 보인다고 밝혔다. Yositaka Nishio 등[4]은 새로운 흡기실험장치를 고안하여 공명기(resonator)의 위치 변화에 의한 저소음 흡기계를 설계 초기단계에서부터 적용하려 하였다. 일반적으로 흡배기계의 복잡한 형상 때문에 대부분 실험을 통해 문제를 해결하려 하였고, 수치해석은 피스톤의 운동을 배제한 단순화한 흡배기계의 정상상태 유동해석이 주를 이루어왔다. Taghaui and Dupont 등[5]은 KIVA코드를 사용하여 흡기포트와 연소실 그리고 밸브의 움직임을 동시에 고려한 수치해석을 도입하였다. 하지만 이들이 밸브의 운동을 고려하기 위해 사용한 이동격자는 격자점은 시간에 따라 변화하지만 그 격자의 수가 일정하게 유지되어 있어서 밸브의 완전개폐를 해석할 수가 없다. 강희정[6]은 단일 실린더와 단일 배기밸브를 갖는 문제로 단순화하여 피스톤과 밸브의 움직임을 고려하므로써 배기행정 후 소음이 어떻게 전파해 나가는가를 연구하였다. 본 연구에서도 최소밸브간격과 최대밸브간격 사이에서만 계산이 가능하나 흡기의 경우는 밸브가 닫힐 때 생기는 압력파가 중요하므로 실린더와 밸브사이에 벽면조건을 주어 밸브의 개폐를 모사하였다.

  • PDF

Establishment of Thermal Infrared Observation System on Ieodo Ocean Research Station for Time-series Sea Surface Temperature Extraction (시계열 해수면온도 산출을 위한 이어도 종합해양과학기지 열적외선 관측 시스템 구축)

  • KANG, KI-MOOK;KIM, DUK-JIN;HWANG, JI-HWAN;CHOI, CHANGHYUN;NAM, SUNGHYUN;KIM, SEONGJUNG;CHO, YANG-KI;BYUN, DO-SEONG;LEE, JOOYOUNG
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.22 no.3
    • /
    • pp.57-68
    • /
    • 2017
  • Continuous monitoring of spatial and temporal changes in key marine environmental parameters such as SST (sea surface temperature) near IORS (Ieodo Ocean Research Station) is demanded to investigate the ocean ecosystem, climate change, and sea-air interaction processes. In this study, we aimed to develop the system for continuously measuring SST using a TIR (thermal infrared) sensor mounted at the IORS. New SST algorithm is developed to provide SST of better quality that includes automatic atmospheric correction and emissivity calculation for different oceanic conditions. Then, the TIR-based SST products were validated against in-situ water temperature measurements during May 17-26, 2015 and July 15-18, 2015 at the IORS, yielding the accuracy of 0.72-0.85 R-square, and $0.37-0.90^{\circ}C$ RMSE. This TIR-based SST observing system can be installed easily at similar Ocean Research Stations such as Sinan Gageocho and Ongjin Socheongcho, which provide a vision to be utilized as calibration site for SST remotely sensed from satellites to be launched in future.

Microbial reduction effect of steam heating, UV irradiation, and gamma irradiation on red pepper powder (스팀 가열 및 자외선, 감마선 조사 처리에 따른 고춧가루의 미생물 저감화 효과)

  • Choi, Jun-Bong;Cheon, Hee Soon;Chung, Myong-Soo;Cho, Won-Il
    • Korean Journal of Food Science and Technology
    • /
    • v.52 no.2
    • /
    • pp.177-182
    • /
    • 2020
  • This study evaluated the effect of steam heating, gamma irradiation, and ultraviolet (UV) irradiation on microorganism reduction in order to determine an effective sterilization method for red pepper powder. The effect of each treatment on the reduction of thermoduric bacteria and total aerobic bacteria in red pepper powder were as follows: 10 kGy gamma irradiation, reduction of 4 log and 6 log CFU/g, respectively; 12 mW/㎠ UV irradiation (264 nm UV-C), reduction of less than 1 log CFU/g; steam heating at 120℃ for 40 s, reduction of approximately 2 log CFU/g. High-temperature short-time processing at 110℃ for 30 s reduced the total bacterial count in Gochujang solution from 5.70 log CFU/g to 2.26 log CFU/g; at 121℃, the solution was commercially sterile. Steam heating resulted in 1, 2, and 4 log microbial inactivation in garlic, onion, and pepper powder, respectively. Steam sterilization, which consumers prefer over other methods, may be an effective method for reducing microorganisms in spice powders, including those in red pepper powder.