• Title/Summary/Keyword: 방사선 피해

Search Result 77, Processing Time 0.025 seconds

The effects of labeling gap and susceptibility artifacts in pCASL perfusion MRI (pCASL 관류 영상에서 표지 간격과 자화감수성 인공물이 영상에 미치는 영향)

  • Kim, Seong-Hu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.213-217
    • /
    • 2015
  • To report problems found in a patient who has implemented stent implantation and then conducted a perfusion MRI using ASL(Arterial Spin Labeling), in order to suggest a solution to them. The perfusion MRI was conducted, using pCASL among ASL methods. Data from pCASL(Pseudo Continuous Arterial Spin Labeling) was acquired together with the structural image simply by changing position(labeling gap 15 mm, 170 mm) of the labeling pulse to avoid stent. Data was processed through the ASLtbx. When perfusion MRI was acquired using pCASL, it showed that the position of the conventional labeling pulse (labeling gap 24 mm) was overlapped with that of stent, which made signal intensity in right brain tissue appear as if it were void. When the labeling pulse was positioned (labeling gap 15 mm) to avoid stent, high signal intensity images were acquired. In labeling pulse (labeling gap 170 mm), the signal intensity was more reduced due to relaxation before labeled blood arrived at the imaging slice. pCASL can be stably repeated measurements because it does not use a contrast agent. And it should be selected with the appropriate image acquisition parameters for the high quality image.

Radiation Protection Effect of Mixed Extracts of Artemisia asiatica Nakai and Moringa oleifera Lam on Rats Uterus (흰쥐의 자궁에 대한 애엽-모링가 혼합추출물의 방사선 방호효과)

  • Lee, Yoon-Ji;Kim, Jang-Oh;Jeon, Chan-hee;Lee, Ji-Eun;Jeong, Geun-Woo;Jung, Do-Young;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.747-753
    • /
    • 2020
  • The purpose of this study was to examine the potential for the development of radioprotective agent in extracts manufactured by mixing Artemisia asiatica Nakai and Moringa oleifera Lam known as antioxidant food with the appropriate ratio. Their whole body were irradiated 7Gy radiation after oral administration of a mixed extract of Artemisia asiatica Nakai and Moringa oleifera Lam to SD Rat for two weeks. And 1 day, 7days, 21days later, changes in blood cell components, SOD activations and tissue changes in the uterus were observed.It was confirmed that the AM + IR group had a higher tendency to recover leukocyte (p<0.05) and platelet (p<0.05) levels than the IR group. It was also confirmed that SOD activity was increased and cell death was decreased in uterine tissue.Based on these results, the mixed extract of A and B is expected to be useful as a radiation protection agent capable of reducing blood cell and uterine damage caused by radiation exposure.

Dose Comparison Using Deformed Image Registration Method on Breast Cancer Radiotherapy (유방암 방사선치료에서 변형영상정합기법을 이용한 선량비교)

  • Won, Young Jin;Kim, Jong Won;Kim, Jung Hoon
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.57-62
    • /
    • 2017
  • The purpose of this study is to reconstruct the treatment plan by applying CBCT and DIR to dose changes according to the change of the patient's motion and breast shape in the large breast cancer patients and to compare the doses using TWF, FIF and IMRT. CT and CBCT were performed with MIM6 to create DIRCT and each treatment plan was made. The patient underwent computed tomography simulation in both prone and supine position. The homogeneity index (HI), conformity index (CI), coverage index (CVI) to the left breast as planning target volume (PTV) were determined and the doses to the lung, heart, and right breast as organ at risk (OAR) were compared by using dose-volume histogram and the unique property of each organ. The value of HI of the PTV breast increased in all treatment planning methods using DIRCT, and CVI and CI were decreased in the treatment planning methods using DIRCT.

The Evaluation of Space Dose Distribution for Digital Mammography Equipment (디지털 유방촬영장비에 관한 공간선량율 평가)

  • Jung, Hongmoon;Jung, Jaeeun;Hyun, Hyejin;Won, Doyeon
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.61-65
    • /
    • 2015
  • Mammography equipment is an essential detector for making an early diagnosis of female's breast lesion. Recently, in most hospitals, a digital mammography detector is used due to the wide and consistent supply of digital mammography equipment. However, the average effective radiation is increasing due to the indiscreet use of CR or DR mammography. The purpose of this study is to recognize the possible indirect radiation damage, which can be occurred due to an excessive effective exposure of radiation, by evaluating spacial radiation rate of the digital mammography detector used for female patient. Consequently, the high mount of spacial radiation showed digital mammography equipment on the horizontal direction. Considering the result, digital mammography equipment should be installed by avoiding along the horizontal direction.

Analysis of Shielding Effect on Gamma Radiation of Magnetic Aggregate Concrete Applied to Protective Facility (군 방호시설에 자철석 콘크리트 적용 시 감마선 차폐효과 분석)

  • Lee, Sang-Kyu;Lee, Ho-Chan;Lee, Gun-Woo;Han, Da-Hee;Park, Young-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.2
    • /
    • pp.129-135
    • /
    • 2020
  • The purpose of this research is to analyze the gamma ray shielding effect of heavy concrete containing magnetic aggregate and to confirm the applicability to the military protective facilities. In general, a military concrete structure protects combatants from bullets, and also it provides some radiation shielding. In this research, experiments were conducted using a Cs-137 source to check the gamma ray shielding effect. In addition, the Monte Carlo N-Particle(MCNP) modeling was applied to evaluate the gamma ray shielding effect of a military structure. As a result, as the concrete thickness increased, the shielding performance improved according th the linear attenuation law. With that, as the ratio of magnetic aggregate was increased, gamma ray shielding performance was also improved. Therefore, this research verified that the application of magnetic aggregate concrete to military facilities for radiation shielding purposes would be useful.

Control of Insects on Stored Rice Grain by Gamma Irradiation (곡류의 해충 구제를 위한 감마선의 이용)

  • Byun, Myung-Woo;Kwon, Joong-Ho;Cha, Bo-Sook;Chung, Kyu-Hoi;Cho, Han-Ok
    • Applied Biological Chemistry
    • /
    • v.31 no.2
    • /
    • pp.143-146
    • /
    • 1988
  • The effect of gamma irradiation on controlling infestation of insects on rice grain were investigated. The egg and larva stages of rice weevil (Sitophilus oryzae) were more radiosensitive than the pupal and adult stages. The complete mortal dose of the first two stages was 0.05kGy, while it was 0.5kGy in the second two stages. In indian-meal moth (plodia interpuctella Hubner), sterile doses of egg, larva, pupa and adult were 0.04 to 0.05, 0.05 to 0.06 and 0.2 to 0.25kGy, respectively. Therefore, the irradiation dose within 1.0kGy was considered to be effective for rice storage so far as reinfestation was prevented. Attractiveness of indian-meal moth toward the rice irradiated at 1.0 to 5.0kGy was non-significant in F-test.

  • PDF

A high energy radiation evaluation test of the 74AC04 Hex Inverter (고준위 감마방사선 환경에서의 원격계측을 통한 74AC04 의 내방사선 영향평가 및 분석)

  • Oh, Seung-Chan;Lee, Hyun-Jin;Lee, Nam-Ho;Lee, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1788_1789
    • /
    • 2009
  • 본 논문에서는 핵폭발과 같은 고준위방사선환경에서의 전자부품소자의 피해평가분석을 통하여 군용전자장비의 내방사선화를 하기 위한 기반기술의 확립을 위한 연구의 일환으로 74AC04(Inverter) IC에 대한 고준위감마선조사시험을 통하여 Co-60 Gamma-ray 선원을 사용하여 총 400Krad[si] 누적 선량에 대한 74AC04 소자의 동작특성 및 전기적 파라메터의 변화분석을 진행하였다. 시험평가 방법 및 절차는 MIL-STD-883G 1019.7[1] 및 ESA/SCC Basic Specification No.22900[2] 절차를 기준으로 하여 동일 lot에 대한 5개의 샘플을 이용하여 동작특성에 영향을 미치는 주요한 전기 적파라메터인 정지소비전류, 입력누설전류, VIL(Maximum Low Level Input Voltage)에 대한 변화추이를 분석하였다. 이번 조사시험을 통하여 입력게이트에서의 누적선량에 따른 TID(Total Ionizing Dose) 효과로 인한 VIL의 감소 추이를 확인 할 수 있었으며 총 누적선량 160Krad 이상에서의 VIL은 허용기준치이하로 감소하였고 정지소비전류의 경우 누적선량에 따른 점진적 증가 현상과 200Krad부근에서의 설계스펙허용치를 초과하는 결과를 확인하였다.

  • PDF

Measurement of Skin Dose from Using the Treatment Immobilization Devices (치료 보조기구 사용 시 후 방향 피부선량 측정)

  • Je, Jae-Yong;Park, Chul-Woo;Noh, Kyung-Suk
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.107-110
    • /
    • 2009
  • The research was about the relation between the dorsal side dose measured by using the phantom body (Alderson Rando Phantom) and factors like contacted material of the patients, the size of the field, angle of incidence. Compared with mylar (tennis racket), the dose on $10{\times}10\;cm^2$ field size of cotton was increased by 2% and by 8% in the case of breast board. In the case of $15{\times}15\;cm^2$ field size, the dose was increased by 6% compared with $10{\times}10\;cm^2$ size. The field size of $20{\times}20\;cm^2$ resulted in 10% increase of dose, while $5{\times}5\;cm^2$ produced 13% decrease. Compared with incident angle $0^{\circ}$, the cases for the incident angle $5^{\circ}$ had 0.4% less dose for breast board, 0.5% for tennis racket, 1.1% for cotton. The cases for the incident angle $10^{\circ}$ had 1.5% less dose for breast board, 1.9% for tennis racket, 2.6% for cotton. For the incident angle $15^{\circ}$, breast board, tennis racket, cotton caused decrease of dose by 3.9%, 2.6%, 3.86% respectively. Resultantly carbon material can cause more skin dose in treatment field. By the results of this study, we recommend that one should avoid the contact between the carbon material and skin.

  • PDF

Analysis of Condition Changing on Dose Variation using Intraoral Radiation Devices (구내 촬영용 방사선 장치의 촬영조건에 따른 선량변화 분석)

  • Kim, Young-Jae;Lee, Yong-Tak;Song, Hyeon-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.137-142
    • /
    • 2012
  • This study is investigated dose change on intra-oral radiography when same conditions under the others unit and same unit under the different exposed conditions. Three different radiation devices were studied. Exposure to the upper anterior, premolar and molar on the variant time and dose measure was using semiconductor radiation dose meter. Obtained film density value was analyzed to the belong in the range of diagnosis. Results for dose of each region were less dissimilar between the maximum and minimum. Its value was different 10 times as many as 3 times. In addition, the range of film density was 2.10 ~ 2.95. These values were exceeded on the allow density of diagnostic value '0.25 ~ 2.0'. Even if the same device and the same condition, measured dose was considerable differance and film density was showed show the inappropriate density range. Those can be caused the patient's re-take and patient's diagnostic errors so patients has affected direct and indirect radiological harm. Therefore, dental radiography devices will be required periodical maintenance and also provided standard on the exposure and processing conditions.

Analysis of Minimum Detectable Activity Concentration of Water Samples and Evaluation of Effective Dose (물 시료의 최소검출가능 농도 분석과 유효선량 평가)

  • Jang, Eun-sung;Kim, Yang-su;Lee, Sun-young;Kim, Jung-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.857-862
    • /
    • 2020
  • In March 2011, a tsunami off Japan caused radioactive material that had seeped into the sea from the Fukushima nuclear accident to flow to the Pacific Ocean, causing pollution to sea life. For a comparative evaluation with the area surrounding the site of a nuclear power plant by the release of radioactive materials, an area 20 to 30 km away from the emergency protection plan area was selected as a comparative point considering weather conditions, population distribution, etc. In addition, the government intends to analyze the minimum detection radiation received by residents around the nuclear power plant and evaluate the effective dose. Analysis of tritium radiation from water samples showed that most of the samples were not detected and that 0.0014 % to 0.777 % of the annual legal standard of 1 mSv for the general public had little effect on the human body. Therefore, the measurement and analysis of water samples around the nuclear power plant site is expected to help relieve anxiety, such as exposure to the general public and neighboring residents due to radiation release.