• Title/Summary/Keyword: 방사선 촬영법

Search Result 262, Processing Time 0.042 seconds

Image Evaluation and Exposure Dose with the Application of Tube Voltage and Adaptive Statistical Iterative Reconstruction of Low Dose Computed Tomography (저 선량 전산화단층촬영의 관전압과 적응식 통계적 반복 재구성법 적용에 따른 영상평가 및 피폭선량)

  • Moon, Tae-Joon;Kim, Ki-Jeong;Lee, Hye-Nam
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.261-267
    • /
    • 2017
  • The study has attempted to evaluate and compare the image evaluation and exposure dose by respectively applying filter back projection (FBP), the existing test method, and adaptive statistical iterative reconstruction (ASIR) with different values of tube voltage during the low dose computed tomography (LDCT). With the image reconstruction method as basis, chest phantom was utilized with the FBP and ASIR set at 10%, 20% respectively, and the change of tube voltage (100 kVp, 120 kVp). For image evaluation, back ground noise, signal-noise ratio (SNR) and contrast-noise ratio (CNR) were measured, and, for dose assessment, CTDIvol and DLP were measured respectively. In terms of image evaluation, there was significant difference in ascending aorta (AA) SNR and inpraspinatus muscle (IM) SNR with the different amount of tube voltage (p < 0.05). In terms of CTDIvol, the measured values with the same tube voltage of 120 kVp were 2.6 mGy with no-ASIR and 2.17 mGy with 20%-ASIR respectively, decreased by 0.43 mGy, and the values with 100 kVp were 1.61 mGy with no-ASIR and 1.34 mGy with 20%-ASIR, decreased by 0.27 mGy. In terms of DLP, the measured values with 120 kVp were $103.21mGy{\cdot}cm$ with no-ASIR and $85.94mGy{\cdot}cm$ with 20%-ASIR, decreased by $17.27mGy{\cdot}cm$ (about 16.7%), and the values with 100 kVp were $63.84mGy{\cdot}cm$ with no-ASIR and $53.25mGy{\cdot}cm$ with 20%-ASIR, a decrease by $10.62mGy{\cdot}cm$ (about 16.7%). At lower tube voltage, the rate of dose significantly decreased, but the negative effects on image evaluation was shown due to the increase of noise.

Analysis of Bone Mellow Density in Adults of Domestic Local Area Using Multi-Detector Computed Tomography: Focus on Corelation About Eating Habits, Lifestyle, Physical Features and Social Characteristics (다중 검출 전산화단층촬영을 이용한 국내 일부 지역 성인의 골밀도 현황 분석: 식습관, 생활습관, 신체적, 사회적 특성과의 상관관계를 중심으로)

  • Lee, Tae Hui;Kim, Tae-Hyung;So, Woon Young;Lim, Hei Gyeom;Lim, Cheong-Hwan;Park, Myeong Hwan;Cheoun, Myung-Ki
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.517-526
    • /
    • 2016
  • This study analyzed the correlation between BMD (bone mineral density) value calculated in the MDCT (multidetector computed tomography) and lifestyle, physical features and social characteristics. From July 15 2015 to June 6 2016, we converted from HU (hounsfield unit) value measured by using MDCT to T-score for BMD of 141 patients (male: 63, female: 78) in W medical center. We measured the 2nd, 3rd and 4th lumbar spine and analyzed the correlation between gender differences in BMD and lifestyle, physical features and social characteristics. Statistical significance was validated using independent sample T test with one way Anova. Gender BMD was confirmed that a statistically significant difference (p<0.05). BMD values decreased with increasing age but for the statistically men, there was no significant difference from 20s to 50s, it only showed a significant difference in 20s and 60s (p<0.001). For the statistically women, there was no significant difference from 20s to 40s. but since 50s BMD was decreased rapidly, which showed a significant difference (p<0.001). women showed significant differences for the menstruation and menopause, childbirth, alcohol, cereals and greasy food in bone mineral density (p<0.05) but there were no significant differences in men. The bone mineral density values calculated by the MDCT and lifestyle, physical features and social characteristics correlation analysis method is considered to be used as a basis for estimating the state in BMD and osteoporosis management.

Usefulness of Deep Learning Image Reconstruction in Pediatric Chest CT (소아 흉부 CT 검사 시 딥러닝 영상 재구성의 유용성)

  • Do-Hun Kim;Hyo-Yeong Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.297-303
    • /
    • 2023
  • Pediatric Computed Tomography (CT) examinations can often result in exam failures or the need for frequent retests due to the difficulty of cooperation from young patients. Deep Learning Image Reconstruction (DLIR) methods offer the potential to obtain diagnostically valuable images while reducing the retest rate in CT examinations of pediatric patients with high radiation sensitivity. In this study, we investigated the possibility of applying DLIR to reduce artifacts caused by respiration or motion and obtain clinically useful images in pediatric chest CT examinations. Retrospective analysis was conducted on chest CT examination data of 43 children under the age of 7 from P Hospital in Gyeongsangnam-do. The images reconstructed using Filtered Back Projection (FBP), Adaptive Statistical Iterative Reconstruction (ASIR-50), and the deep learning algorithm TrueFidelity-Middle (TF-M) were compared. Regions of interest (ROI) were drawn on the right ascending aorta (AA) and back muscle (BM) in contrast-enhanced chest images, and noise (standard deviation, SD) was measured using Hounsfield units (HU) in each image. Statistical analysis was performed using SPSS (ver. 22.0), analyzing the mean values of the three measurements with one-way analysis of variance (ANOVA). The results showed that the SD values for AA were FBP=25.65±3.75, ASIR-50=19.08±3.93, and TF-M=17.05±4.45 (F=66.72, p=0.00), while the SD values for BM were FBP=26.64±3.81, ASIR-50=19.19±3.37, and TF-M=19.87±4.25 (F=49.54, p=0.00). Post-hoc tests revealed significant differences among the three groups. DLIR using TF-M demonstrated significantly lower noise values compared to conventional reconstruction methods. Therefore, the application of the deep learning algorithm TrueFidelity-Middle (TF-M) is expected to be clinically valuable in pediatric chest CT examinations by reducing the degradation of image quality caused by respiration or motion.

A STUDY ON THE POSITION OF CONDYLAR HEAD ON COMPUTED TOMOGRAM (전산화 단층 촬영법을 이용한 하악과두의 위치에 관한 연구)

  • Lee Jong Bok;Kim Jae Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.17 no.1
    • /
    • pp.151-162
    • /
    • 1987
  • The author obtained the computed tomograms around the condylar head from 10 normal subjects and 5 patients having clicking condylar head from 10 normal subjects and 5 patients having clicking sound or limitation of mouth opening by using a Hitachi-W 500. And then. the author had the axial analysis of condyle position and sagittal analysis of that after sagittal reformation on centric occlusion and 18㎜ interincisal opening. Transcranial view and submentovertex view were taken and compared with computed tomographic view. The obtained results were as follows: 1. Median angle of long axis of condylar head was 17 degrees on centric occlusion and the angles of long axis of both condylar heads were reduced symmetrically on 18㎜ interincisal opening in normal group. however. in the patient group, the affected side of condyle heads showed greater change in the angle on 18㎜ interincisal opening. 2. In the patient group, the condyle head of affected side was located superiorly to that of normal side on centric occlusion and the discrepancy of condular positional height was increased after 18㎜ interincisal opening. 3. The distances from medial pole of condylar head to triangular fossa of temporal bone were same on both right and left side in normal group, however, in the patient group, the distance of affected side was wider than that of opposite side on centric occusion and became narrower than the opposite side on 18㎜ interincisal opening. 4. The distances of posterior joint space were same on both right and left side. The distance t lateral pole 1/3 of condyle head was similar to that on transcranial view on centric occlusion in normal group. 5. The distances of posterior joint space were narrower in patient group than in normal group. 6. Conclusively, the affected condylar head of patient showed postero-latero-superior displacement on centric occlusion and larger range of rotational movement on 18㎜ interincisal opening.

  • PDF

SURGICAL REPAIR OF COMPLETE BONY BILATERAL CHOANAL ATRESIA VIA TRANSPALATAL APPROACH (완전 골성 양측성 후비공 폐쇄 환자의 구개부를 통한 외과적 치험례)

  • Kim, Kyoung-Won;Cho, Yong-Seok;Yang, Soo-Nam
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.20 no.2
    • /
    • pp.133-138
    • /
    • 1998
  • Choanal atresia may be membrane or bony, unilateral or bilateral. Approximately 90% of the choanal atresia are bony type. Unilateral choanal atresia often eludes the diagnosis because of the absence of subjective symptoms in the neonatal period. However, bilateral choanal atresia presents at birth with cyclic respiratory distress aggravated by feedings. So complete bilateral choanal atresia is considered as a neonatal emergency. Examinations for the diagnosis of chonal atresia include 1) attempt at passing a rubber catheter or probe through the patient s nose, 2) mirror examination of the nasopharynx, 3) digital examination of the nasopharynx, 4) X-ray examination after installation of radiopaque materal into the nasal cavity. But, computed tomography has become accepted method for evaluation of choanal atresia. Surgical repair of choanal atresia is accomplished via transnasal or transpalatal approach. Advantages of the transpalatal approach are improved exposure and the preservation of mucosal flap along the newly formed apertures. On the other hand, the transpalatal approach carries the risk of injury to the greater palatine neurovascular complex, and requires longer operative time. After careful physical and radiographic examinations, we accomplished the surgical repair of the complete bony bilateral choanal atresia via transpalatal approach without complications.

  • PDF

Diagnostic Approach to a Soft Tissue Mass (연부조직 종양의 진단적 접근)

  • Chun, Young Soo;Song, Seung Hyun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.4
    • /
    • pp.293-301
    • /
    • 2019
  • Soft tissue masses of the extremities and torso are a common problem encountered by orthopaedic surgeons. Although these soft tissue masses are often benign, orthopaedic surgeons need to recognize the key features differentiating benign and malignant masses. An understanding of the epidemiology and clinical presentation of soft tissue masses is needed to develop a practical approach for evaluation and surgical management. Size and depth are the two most important factors on which triage decisions should be based. In a differential diagnosis of a tumor, it is important to know the characteristics of the soft tissue mass through detailed history taking and physical examinations before the diagnostic procedures. A variety of imaging studies, such as simple radiography, ultrasound, magnetic resonance imaging, positron emission tomography, computed tomography, bone scan, and angiography can be used to diagnose tumors. Know the ledge of advantages and disadvantages of each imaging study is essential for confirming the characteristics of the tumor that can be observed in the image. In particular, ultrasonography is convenient because it can be performed easily in an outpatient clinic and its cost is lower than other image studies. On the other hand, the accuracy of the test is affected by the skill of the examiner. A biopsy should be performed to confirm the tumor and be performed after all imaging studies have been done but before the final treatment of soft tissue tumors. When a biopsy is to be performed, careful attention to detail with respect to multidisciplinary coordination beforehand, cautious execution of the procedure to minimize complications, and expedient follow-up and referral to a musculoskeletal oncologist when appropriate, are essential.

Application of Dual Tree Complex Wavelet for Performance Improvement of CT Images (CT 영상의 화질개선을 위한 이중트리복합웨이블릿의 적용)

  • Choi, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.941-946
    • /
    • 2019
  • Computed tomography (CT) has been increasing in frequency and indications for use in clinical diagnosis and treatment decisions. Multidetector CT has the advantage of shortening the inspection time and obtaining a high resolution image compared to a single detector CT, but has been pointed out the disadvantage of increasing the radiation exposure. In addition, when the low tube voltage is used to reduce the exposure dose in the CT, noise increases relatively. In the existing method, the method of finding the optimal image quality using the method of adjusting the parameters of the image reconstruction method is not a fundamental measure. In this study, we applied a double-tree complex wavelet algorithm and analyzed the results to maintain the normal signal and remove only noise. Experimental results show that the noise is reduced from 8.53 to 4.51 when using a complex oriented 2D method with 100kVp and 0.5sec rotation time. Through this study, it was possible to remove the noise and reduce the patient dose by using the optimal noise reduction algorithm. The results of this study can be used to reduce the exposure of patients due to the low dose of CT.

3D Reconstruction Using Segmentation of Myocardial SPECT Images (SPECT 심근영상의 영상분할을 이용한 3차원 재구성)

  • Jung, Jae-En;Lee, Sang-Bock
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.2
    • /
    • pp.5-10
    • /
    • 2009
  • Myocardial imaging in SPECT (Single Photon Emission Computed tomography) scan of the gamma-ray emitting radiopharmaceuticals to patients after intravenous radiopharmaceuticals evenly spread in the heart region of interest by recording changes in the disease caused by a computer using the PSA test is to diagnose. Containing information on the functional myocardial perfusion imaging is a useful way to examine non-invasive heart disease, but the argument by noise and low resolution of the physical landscape that is difficult to give. For this paper, the level of myocardial imaging by using the three algorithms to split the video into 3-D implementation of the partitioned area to help you read the proposed plan. To solve the difficulty of reading level, interest in using the sheet set, partitioned area of the left ventricle was ranked the partitioned area was modeled as a 3-D images.

  • PDF

A Study of Inter-observer Agreements of Spiral Chest Computed Tomography in Diagnosing Pulmonary Embolism (폐색전증에서 나선형 컴퓨터 전산화 단층촬영의 관찰자간의 일치도에 관한 연구)

  • Kim, Yang-Ki;Lee, Young Mok;Kim, Ki-up;Uh, Soo-taek;Kim, Yong Hoon;Park, Choon Sik;Hwang, Jung-Hwa;Kim, Dong Hun;Goo, Dong-Erk;Choi, Deuk-Lin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.5
    • /
    • pp.473-479
    • /
    • 2005
  • Background : A pulmonary embolism often presents with nonspecific symptoms and signs. However, a delayed diagnosis can result in catastrophic outcome. The majority of preventable deaths associated with a pulmonary embolism can be ascribed to a missed diagnosis rather than to the failure of existing treatments. Therefore, accurate and rapid diagnostic methods are essential for the management of a pulmonary embolism. The recent generation of multidetector-row spiral CT scanners appears to outperform other imaging modalities in detecting a central and peripheral pulmonary embolism. However, there are some variations in the interpretations of the findings between observers. This study examined the inter-observer differences of the diagnoses in patients with a pulmonary embolism. Method : 64 patients who were diagnosed with a pulmonary embolism either clinically or with spiral chest CT from 2002 to 2004, were included. Two thoracic radiologists interpreted the multidetector-row spiral CT in terms of the diagnosis of a pulmonary embolism and the location of the thrombus independently. Among 64 patients, 14 patients were excluded because there was no evidence of a pulmonary embolism or there was different interpretation of the pulmonary embolism between radiologists. A clinical diagnosis was based on "Rules for predicting the probability of embolism". Results : The mean score of the patients according to the Wells method was $3.91{\pm}0.30$ (0-9). The accordance of the radiologists was 95% in the main, 85% in the lobar, 91.2% in the segmental, and 96% in the sub-segmental pulmonary arteries. After excluding the negative interpretation from both radiologists, their agreement was 76.2%(${\kappa}.$ 0.83) in the main, 57.6%(${\kappa}.$ 0.63) in the lobar, 51.5%(${\kappa}.$ 0.63) in the segmental, and 34.6%(${\kappa}.$ 0.49) in the sub-segmental pulmonary arteries. Conclusion : Chest CT has been recently applied to patients suspected of having a pulmonary embolism. It was found that spiral CT is a rapid test for diagnosing a thrombus, and there was reliable accordance between the observers from the area of the large pulmonary arteries. However, there was a lack of agreement between the observers in diagnosing thrombi located distal to the sub-segmental arteries.

A Study on the Fabrication and Comparison of the Phantom for CT Dose Measurements Using 3D Printer (3D프린터를 이용한 CT 선량측정 팬텀 제작 및 비교에 관한 연구)

  • Yoon, Myeong-Seong;Kang, Seong-Hyeon;Hong, Soon-Min;Lee, Youngjin;Han, Dong-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.737-743
    • /
    • 2018
  • Patient exposure dose exposure test, which is one of the items of accuracy control of Computed Tomography, conducts measurements every year based on the installation and operation of special medical equipment under Article 38 of the Medical Law, And keep records. The CT-Dose phantom used for dosimetry can accurately measure doses, but has the disadvantage of high price. Therefore, through this research, the existing CT - Dose phantom was similarly manufactured with a 3D printer and compared with the existing phantom to examine the usefulness. In order to produce the same phantom as the conventional CT-Dose phantom, a 3D printer of the FFF method is used by using a PLA filament, and in order to calculate the CTDIw value, Ion chambers were inserted into the central part and the central part, and measurements were made ten times each. Measurement results The CT-Dose phantom was measured at $30.44{\pm}0.31mGy$ in the periphery, $29.55{\pm}0.34mGy$ CTDIw value was measured at $30.14{\pm}0.30mGy$ in the center, and the phantom fabricated using the 3D printer was measured at the periphery $30.59{\pm}0.18mGy$, the central part was $29.01{\pm}0.04mGy$, and the CTDIw value was measured at $30.06{\pm}0.13mGy$. Analysis using the Mann - Whiteney U-test of the SPSS statistical program showed that there was a statistically significant difference in the result values in the central part, but statistically significant differences were observed between the peripheral part and CTDIw results I did not show. In conclusion, even in the CT-Dose phantom made with a 3D printer, we showed dose measurement performance like existing CT-Dose phantom and confirmed the possibility of low-cost phantom production using 3D printer through this research did it.