• Title/Summary/Keyword: 방사선 영향평가

Search Result 741, Processing Time 0.021 seconds

Treatment Outcome of Thymic Epithelial Tumor: Prognostic Factors and Optimal Postoperative Radiation Therapy (흉선상피종의 치료 성적: 예후 인자 및 방사선치료 방법에 대한 연구)

  • Oh Dong Ryul;Ahn Yong Chan;Kim Kwan Min;Kim Jhingook;Shim Young Mog;Han Jung Ho
    • Radiation Oncology Journal
    • /
    • v.23 no.2
    • /
    • pp.85-91
    • /
    • 2005
  • Purpose : This study was conducted to analyze treatment outcome and prognostic significance of World Health Organization (WHO)-defined thymic epithelial tumor (TET) subtype and to assess optimal radiation target volume in patients receiving surgery and adjuvant radiation therapy with TET. Materials and Methods: The record of 160 patients with TET, who received surgical resection at the Samsung medical Center, from December 1994 to June 2004, were reviewed. 99 patients were treated with postoperative radiation therapy (PORT). PORT was recommended when patients had more than one findings among suspicious Incomplete resection or positive resection margin or Wasaoka stage $II\~IV$ or WHO type $B2\~C$. PORT peformed to primary tumor bed only with a mean dose of 54 Gy. The prognostic factor and pattern of failure were analyzed retrospectively. Results : The overall survival rate at 5 years was $87.3\%$. Age (more than 60 years $77.8\%$, less than 60 years $91.1\%$; p=0.03), Wasaoka stage (I $92.2\%$, II $95.4\%$, III $82.1\%$, IV $57.5\%$; p=0.001), WHO tumor type (A-Bl $96.0\%$, B2-C $82.3\%$; p=0.001), Extent of resection (R0 resection $92.3\%$, R1 or 2 resection $72.6\%$, p=0.001) were the prognostic factors according to univariate analysis. But WHO tumor type was the only significant prognostic factor according to multivariate analysis. Recurrence was observed in 5 patients of 71 Masoka stage I-III patients who received grossly complete tumor removal (R0, R1 resection) and PORT to primary tumor bed. Mediastinal recurrence was observed In only one patients. There were no recurrence within irradiation field. Conclusion : WHO tumor type was the important prognostic factor to predict survival of patients with TET. This study suggest that PORT to only primary tumor bed was optimal. To avoid pleura- or pericardium-based recurrence, further study of effective chemotherapy should be investigated.

Evaluation of Separation Distance from the Temporary Storage Facility for Decontamination Waste to Ensure Public Radiological Safety after Fukushima Nuclear Power Plant Accident (후쿠시마 원전 사고 이후 일반인의 방사선학적 안전성 확보를 위한 제염폐기물 임시저장시설 이격거리 평가)

  • Kim, Min Jun;Go, A Ra;Kim, Kwang Pyo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.3
    • /
    • pp.201-209
    • /
    • 2016
  • The object of this study was to evaluate the separation distance from a temporary storage facility satisfying the dose criteria. The calculation of ambient dose rates took into account cover soil thickness, facility size, and facility type by using MCNPX code. Shielding effects of cover soil were 68.9%, 96.9% and 99.7% at 10 cm, 30 cm and 50 cm respectively. The on-ground type of storage facility had the highest ambient dose rate, followed by the semi-ground type and the underground type. The ambient dose rate did not vary with facility size (except $5{\times}5{\times}2m\;size$) due to the self-shielding of decontamination waste in temporary storage. The separation distances without cover soil for a $50{\times}50{\times}2m\;size$ facility were evaluated as 14 m (minimum radioactivity concentration), 33 m (most probably radioactivity concentration), and 57 m (maximum radioactivity concentration) for on-ground storage type, 9 m, 24 m, and 45 m for semi-underground storage type, and 6 m, 16 m, and 31 m for underground storage type.

Comparison of CT Image Performance with or without Tin Filter based on Blind Image Quality Evaluation Method (블라인드 품질 평가 방법을 사용한 주석필터 사용 유무에 따른 CT 영상 특성 비교)

  • Shim, Jina;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.301-306
    • /
    • 2021
  • The use of tin filters as a way to reduce the medical radiation in computed tomography (CT). However, due to the changed X-ray spectrum with the use of tin filters, disease diagnosis could be affected because it appears as images of different impressions from previous images. Therefore, this study evaluates the changes in images when using tin filter and high pitch in chest low-dose CT. In this study, images were acquired in groups of three for comparison. Group 1 did not apply to tin filter, and used the existing pitch 0.8. Group 2 used a tin filter, pitch 0.8, Group 3 used a tin filter, and pitch 2.5. To compare the image quality, the natural image quality evaluator (NIQE) and the blind/referenceless image quality evaluator (BRISQUE) were used among the blind quality evaluation factors depended on a no-reference basis. As a result, the NIQE values were low in the order of Group 1, Group 3, and Group 2. BRISQUE values were low in the order of Group 3, Group 2 and Group 1. This study confirms the superiority of images of tin filter and high pitch techniques in chest low-dose CT, which is considered to be a fundamental study for acquiring accurate images of patients with difficult breathing control.

Evaluation of Distortion in Measuring the Stability of Distal Radio-ulnar Joint in Wrist PA-Grip View (Wrist PA-grip view에서 먼쪽노자관절의 안정성 정도 측정 시 왜곡도 평가)

  • Shim, Jina;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.321-327
    • /
    • 2021
  • Wrist PA-grip view is used to diagnose triangular fibrocartilage complex (TFCC) tear because it can easily diagnose damage to the surrounding wrist ligaments. However, despite advances in radiology equipment, distortion of images due to geometric elements still has many limitations. In this paper, we propose a method that can minimize the distortions of images by analyzing the distortions occurring in the wrist PA-grip view. A source of image distance (SID) were set at 130 cm and 150 cm for comparison with 110 cm. Depending on the SID, the phantom of wrist was moved at 0, 2, 4, 6, 8, and 10 cm in the X-axis and Y-axis directions, respectively. For quantitative evaluation, the difference of distance between the radius and ulna was measured in picture archiving and communication system (PACS) system. As a qualitative evaluation, survey was conducted among 20 radiologic technologists who examined the Wrist PA-grip view. The Kruskal Wallis test was performed to compare the distortion according to the phantom movement in the X-axis and Y-axis directions based on the SID, and the Tukey test was performed as a post-test. In the quantitative evaluation results, the measured values obtained in the X-axis was not significantly different in all groups (p>0.05). The measured values obtained in the Y-axis was significantly different in the most groups (p<0.05). Therefore, to reduce distortion while maintaining image quality, we recommend what examine the SID at 150 cm than 110 cm.

Radiation Therapy for Carcinoma of the Oropharynx (구인두암의 방사선치료)

  • Park, In-Kyu;Kim, Jae-Choel
    • Radiation Oncology Journal
    • /
    • v.14 no.2
    • /
    • pp.95-103
    • /
    • 1996
  • Purpose : A retrospective analysis for patients with oropharyngeal carcinoma who were treated with radiation was performed to assess the results of treatment and patterns of failure, and to identify the factors that might influence survival. materials and methods : From March 1985 through June 1993, 53 patients with oropharyngeal carcinoma were treated with either radiation therapy alone or combination of neoadjuvant chemotherapy and radiation therapy at the Department of Radiation Oncology, Kyungpook National University Hospital. Patients' ages ranged from 31 to 73 years with a median age of 54 years. There were 47 men and 6 women, Forty-two Patients ($79.2\%$) had squamous cell carcinoma, 10 patients ($18.9\%$) had undifferentiated carcinoma and 1 patient ($19\%$) had adenoid cystic carcinoma. There were 2 patients with stage I, 12 patients with stage II, 12 Patients with stage III and 27 patients with stage IV. According to the TNM classification, patients were distributed as follows: T1 7, T2 28, T3 10, T4 7, TX 1, and N0 17, Nl 13, N2 21, N3 2. The primary tumor sites were tonsillar region in 36 patients ($67.9\%$), base of the tongue in 12 patients ($22.6\%$), and soft palate in 5 patients ($9.4\%$). Twenty-five patients were treated with radiation therapy alone and twenty-eight Patients were treated with one to three courses of chemotherapy followed by radiation therapy. Chemotherapeutic regimens used were either CF (cisplatin and 5-fluorouracil) or CVB (cisplatin, vincristine and bleomycin). Radiation therapy was delivered 180-200 cGy daily, five times a week using 6 MV X-ray with or without 8-10 MeV electron beams A tumor dose ranged from 4500 cGy to 7740 cGy with a median dose of 7100 cGy. The follow-up time ranged from 4 months to 99 months with a median of 21 months. Results : Thirty-seven patients ($69.8\%$) achieved a CR (complete response) and PR (partial response) in 16 patients ($30.2\%$) after radiation therapy. The overall survival rates were $47\%$ at 2 years and $42\%$ at 3 years, respectively. The median survival time was 23 months. Overall stage (p=0.02) and response to radiation therapy (p=0.004) were significant prognostic factors for overall survival. The 2-year disease-free survival rate was $45.5\%$. T-stage (p=0.03), N-stage (p=0.04) and overall stage (P=0.04) were significant prognostic factors for disease-free survival. Age, sex, histology, primary site of the tumor, radiation dose, combination of chemotherapy were not significantly associated with disease-free survival. Among evaluable 32 Patients with CR to radiation therapy, 12 patients were considered to have failed Among these, 8 patients failed locoregionally and 4 Patients failed distantly. Conclusion : T-stage, N-stage and overall stage were significant prognostic factors for disease-free survival in the treatment of oropharyngeal cancer Since locoregional failure was the predominant pattern of relapse, potential methods to improve locoregional control with radiation therapy should be attempted. More controlled clinical, trials should be completed before acceptance of chemotherapy as a part of treatment of oropharyngeal carcinoma.

  • PDF

A Study for Effects of Image Quality due to Scatter Ray produced by Increasing of Tube Voltage (관전압 증가에 기인한 산란선 발생의 화질 영향 연구)

  • Park, Ji-Koon;Jun, Je-Hoon;Yang, Sung-Woo;Kim, Kyo-Tae;Choi, Il-Hong;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.663-669
    • /
    • 2017
  • In diagnostic medical imaging, it is essential to reduce the scattered radiation for the high medical image quality and low patient dose. Therefore, in this study, the influence of the scattered radiation on medical images was analyzed as the tube voltage increases. For this purpose, ANSI chest phantom was used to measure the scattering ratio, and the scattering effect on the image quality was investigated by RMS evaluation, RSD and NPS analysis. It was found that the scattering ratio with increasing x-ray tube voltage gradually increased to 48.8% at 73 kV tube voltage and to 80.1% at 93 kV tube voltage. As a result of RMS analysis for evaluating the image quality, RMS value according to increase of tube voltage was increased, resulting in low image quality. Also, the NPS value at 2.5 lp/mm spatial frequency was increased by 20% when the tube voltage was increased by 93 kV compared to the tube voltage of 73 kV. From this study, it can be seen that the scattering radiation have a significant effect on the image quality according to the increase of x-ray tube voltage. The results of this study can be used as basic data for the improvement of medical imaging quality.

Influence to the Doppler Images by the Defects of Piezoelectric Elements of the Probe of Medical Ultrasonic Scanners (Focusing on the Impact of an Increase in the Defects of Piezoelectric Elements) (초음파 프로브 소자 결함이 도플러 영상에 미치는 영향 (소자 결함 증가에 따른 영향을 중심으로))

  • Lee, Kyung-Sung
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.117-124
    • /
    • 2014
  • This study has investigated the effects of the defects in the probe elements influence Doppler images in the medical ultrasonic scanners. This work was implemented that the quality of Doppler images depended on the extent and location of the probe element defected. The probe performance was rated in terms of the number of piezoelectric elements lost and this was studied in the experiment by electrical disconnection to the elements. The results showed that Doppler velocity became rapidly reduced as the defected elements encountered with the element group activated at the Doppler mode, not as the flow velocity. The effect of the probe defect is decreased when the defects occurred at the element group activated for Doppler mode, as was increased the number of the elements. It was observed that the higher the flow velocity of Doppler flow phantom is, the wider the spectrum of Doppler is. And the Doppler velocity soared up and the dispersion of image brightness is increased when the defected elements got out of the elements activated at Doppler mode. The result showed that TADVP(time-average-Doppler-velocity-profile) is decreased with the increase of the probe element defect, especilly in the region of high frequency. It is expected that the research of various defects of probe elements are needed, and this study can be practical tools for probe based ultrasonic QA in the future.

Monitoring of Trace Elements in $PM_{2.5}/PM_{10}$ of Daejeon region using Neutron Activation Analysis (중성자방사화분석에 의한 대전지역의 $PM_{2.5}/PM_{10}$중 미량 금속 측정연구)

  • 정용삼;문종화;박광원;김선하;백성열
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.317-318
    • /
    • 2001
  • PM$_{10}$ 대기먼지는 자연적이고 인위적인 발생원에 의해 다양한 미량원소들을 함유하고 있기 때문에 흔히 대기질이나 환경영향 평가를 위한 대기관측시료로 이용되고 있으며, 특히 PM$_{2.5}$ 먼지의 질량농도와 특정원소의 농도가 높을 때, 장\ulcorner단기적으로 인체 보건에 큰 영향을 미치는 것으로 알려져 있다. 중성자 방사화분석법은 핵반응을 통해 생성시킨 방사성동위원소로부터 방출되는 방사선을 검색하여 절대적으로 성분원소를 정량하는 핵분석기술(Nuclear Analytical Techniques)중의 하나로서 소량의 시료로부터 미량 원소의 비파괴, 동시 다원소 분석이 가능하고 분석감도($10^{-3}$ - $10^{-7}$$\mu\textrm{g}$)가 탁월한 분석기술이다. (중략)략)

  • PDF

Manufacture of Flow Phantom with Stenosis and Imaging Evaluation of Power Doppler (혈관협착팬텀의 제작 및 파워도플러의 영상 평가)

  • Park, Hee-Young;Bae, Jong-Rim;Kim, Jeong-Koo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.8
    • /
    • pp.732-739
    • /
    • 2009
  • Flow phantom with stenosis was manufactured using an auto-injector to obtain angiostenotic flow information and quality assurance (QA) for ultrasound diagnostic instrumentation. Effectiveness of manufactured flow phantom with stenosis was investigated with power Doppler that was known to have diagnostic efficiency for angiostenosis. The flow phantom with stenosis was manufactured to 70% stenosis with 8 mm and 2.4 mm silicon tube, and silicone tube was covered with gelatin that has acoustic characteristics similar to soft tissue. When the linear transducer was used for measurement, the estimated diameter of normal vessel was measured lower than that of normal value, and the estimated diameter of stenosed vessel was measured higher than that of normal value. The measured parameters were not affected except for the radical conditions such as gain of 60%, PRF of 3000 Hz, use of maximal filter or angle. In addition, when the convex transducer was used for measurement, measurement parameters were affected by gain, PRF, filter, and angle. Therefore it is expected that flow phantom with stenosis manufactured with an auto-injector will be utilized effectively for QA of angiostenotic diagnosis.

The Correlation Between Early Clinical State and Functional Outcome in Acute Stroke Patients (급성기 뇌졸증 환자의 상태와 기능회복도와의 상관관계)

  • Choi, Eun-Jung;Lee, Won-Chul
    • The Journal of Dong Guk Oriental Medicine
    • /
    • v.6 no.2
    • /
    • pp.167-190
    • /
    • 1998
  • Nowadays there were two tendencies of studies about prognostic factors in stroke. One way was to define prognostic factors according to the radiological features. And the other way was to define according to the mental state, recognition, perception, motors, language, urinary&bowel incontinence etc.. The former could be objectively investigated, while the latter was difficult. The purpose of this study was to determine which variables would be predictors of stroke and which factors would be affect predictions most. The subjects of this study were 32 patients who were admitted to the Dept. of Internal Medicine, Dongguk Univ. College of Oriental Medicine whthin 48 hours from attack, Medical records were reviewed FIM, CNS, NIH stroke scale. We compared each sub-items of FIM, CNS, NIH stroke scale about mental state, recognition, perception, motors, language, urinary&bowel incontinence with MBI score at 4 weeks from admission. Also, we analyzed the correlations of sub-items and groups which devided into 5 according to independence of MBI score. And we found out the most influent factors with multiple regression analysis. The major results were as follows; 1. In mean of MBI score at 4 weeks of each groups devided low, middle, high score at mental state, recognition, perception, motors, language, urinary&bowel incontinence items, there were statistical differences in all items. 2. The mental state and lim ataxia sub-items had no significant correlations with groups divided according to independence of MBI score. All the other items were significantly correlated. 3. The most influent factors was recognition. The second was sensory and the third was bowel incontinence. 4. The most influent scales was FIM, and the second was CNS, and NlH had no statistical significancy.

  • PDF