• Title/Summary/Keyword: 방사선오염

Search Result 321, Processing Time 0.034 seconds

Microbiological Contamination Level and Radiation Sterilization in Disposable Kitchen Utensil (일회용 주방용품의 미생물 오염도평가 및 방사선 살균)

  • Kim Jin-Hee;Lim Sang-Yong;Song Hyun-Pa;Kim Byeong-Keun;Chung Jin-Woo;Yoon Hae-Jung;Byun Myung-Woo;Kim Dong-Ho
    • Food Science and Preservation
    • /
    • v.12 no.4
    • /
    • pp.317-322
    • /
    • 2005
  • The purposes of this study were to assess the microbiological contamination level of various disposable kitchen utensils and evaluate the effectiveness of gamma irradiation as a sterilization process for the utensils. The 51 kinds in 17 groups of disposable kitchen utensils were tested for the enumeration of total aerobic plate count, coliforms, fungi and Salmonella. Generally, cell density of microorganisms in disposable kitchen utensils were lower than that of cooking utensils currently using in kitchen. The survivals of total aerobic plate counts, putrefactive bacteria, on the surface of the disposable utensils were ranged up to $10^3\;CFU/100\;cm^2$. Filamentous fungi were detected in 13 samples. Coliform bacteria were detected in two kinds of samples but Salmonella spp. was detected below detection limits in all the samples. The microorganisms survived on the surface of utensils were effectively eliminated by gamma irradiation process at 3 kGy.

Microbial Hazards and Microbe Reduction Technologies for Mushrooms (버섯의 미생물 위해성 및 저감화 처리기술 개발 현황)

  • Hyunji Song;Areum Han;Boyang Meng;A-Ra Jang;Ji-Yeon Kim;Sun-Young Lee
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.5
    • /
    • pp.287-296
    • /
    • 2023
  • Mushroom consumption is gradually growing annually worldwide for many centuries. Oyster mushrooms (Pleurotus ostreatus), button mushrooms (Agaricus bisporus), and enokitake (Flammulina filiformis) are mainly consumed in Korea. However, mushrooms can be contaminated with pathogenic microorganisms, such as Listeria monocytogenes, because antibacterial treatment during mushroom cultivation and processing is insufficient. Therefore, many cases of mushroom contamination-related foodborne illnesses and food recalls have been reported. Three representative treatments are used to prevent microbial contamination in mushrooms: chemical, physical, and combination treatments. Among the chemical treatments, chlorine compounds, peroxyacetic acid, and quaternary ammonium compounds are commercially used and ozone and electrolyzed water has recently been used. Additionally, physical treatments, including ultrasound, irradiation, and cold plasma, are being developed. Combination techniques include ultraviolet/chlorine compounds, ozone/organic acid, and ultrasound/organic acid. This review describes the domestically consumed mushroom types and their characteristics, and investigates the mushroom contamination levels. Additionally, effective antibacterial technologies for reducing microbial contamination in mushrooms are also discussed.

Dose Rate of Restroom in Facilities using Radioisotope (방사성동위원소 사용시설(내/외) 화장실의 외부선량률)

  • Cho, Yong-Gwi;An, Seong-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.237-246
    • /
    • 2016
  • This study is therefore aimed at measuring the surface dose rate and the spatial dose rate in and outside the radionuclide facility in order to ensure safety of the patients, radiation workers and family care-givers in their use of such equipment and to provide a basic framework for further research on radiation protection. The study was conducted at 4 restrooms in and outside the radionuclide facility of a general hospital in Incheon between May 1 and July 31, 2014. During the study period, the spatial contamination dose rate and the surface contamination dose rate before and after radiation use were measured at the 4 places-thyroid therapy room, PET center, gamma camera room, and outpatient department. According to the restroom use survey by hospitals, restrooms in the radionuclide facility were used not only by patients but also by family care-givers and some of radiation workers. The highest cumulative spatial radiation dose rate was 8.86 mSv/hr at camera room restroom, followed by 7.31 mSv/hr at radioactive iodine therapy room restroom, 2.29 mSv/hr at PET center restroom, and 0.26 mSv/hr at outpatient department restroom, respectively. The surface radiation dose rate measured before and after radiation use was the highest at toilets, which are in direct contact with patient's excretion, followed by the center and the entrance of restrooms. Unsealed radioactive sources used in nuclear medicine are relatively safe due to short half lives and low energy. A patient who received those radioactive sources, however, may become a mobile radioactive source and contaminate areas the patient contacts-camera room, sedation room, and restroom-through secretion and excretion. Therefore, patients administered radionuclides should be advised to drink sufficient amounts of water to efficiently minimize radiation exposure to others by reducing the biological half-life, and members of the public-family care-givers, pregnant women, and children-be as far away from the patients until the dose remains below the permitted dose limit.

Dose Distribution and Design of Dynamic Wedge Filter for 3D Conformal Radiotherapy (방사선 입체조형치료를 위한 동적쐐기여과판의 고안과 조직내 선량분포 특성)

  • 추성실
    • Progress in Medical Physics
    • /
    • v.9 no.2
    • /
    • pp.77-88
    • /
    • 1998
  • Wedge shaped isodoses are desired in a number of clinical situations. Hard wedge filters have provided nominal angled isodoses with dosimetric consequences of beam hardening, increased peripheral dosing, nonidealized gradients at deep depths along with the practical consequendes of filter handling and placement problems. Dynamic wedging uses a combination of a moving collimator and changing monitor dose to achieve angled isodoses. The segmented treatment tables(STT) that monitor unit setting by every distance of moving collimator, was induced by numerical formular. The characteristics of dynamic wedge by STT compared with real dosimetry. Methods and Materials : The accelerator CLINAC 2100C/D at Yonsei Cancer Center has two photon energies (6MV and 10MV), currently with dynamic wedge angles of 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$ and 60$^{\circ}$. The segmented treatment tables(STT) that drive the collimator in concert with a changing monitor unit are unique for field sizes ranging from 4.0cm to 20.0cm in 0.5cm steps. Transmission wedge factors were measured for each STT with an standard ion chamber. Isodose profiles, isodose curves, percentage depth dose for dynamic wedge filters were measured with film dosimetry. Dynamic wedge angle by STT was well coincident with film dosimetry. Percent depth doses were found to be closer to open field but more shallow than hard wedge filter. The wedge transmission factor were decreased by increased the wedge angle and more higher than hard wedge filters. Dynamic wedging probided more consistent gradients across the field compared with hard wedge filters. Dynamic wedging has practical and dosimetric advantages over hard filters for rapid setup and keeping from table collisions. Dynamic wedge filters are positive replacement for hard filters and introduction of dynamic conformal radiotherapy and intensity modulation radiotherapy in a future.

  • PDF

Study on Radioactive Material Management Plan and Environmental Analysis of Water (II) Study of Management System in Water Environment of Japan (물 환경의 방사성 물질 관리 방안과 분석법에 관한 연구 (II) 일본의 물 환경 방사성물질 관리 체계에 대한 고찰)

  • Han, Seong-Gyu;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.305-313
    • /
    • 2015
  • After Fukushima Daiichi nuclear disaster in 2011, study and maintenance of monitoring systems have been made at home and abroad. As concerns about radioactive contamination of water have increased in Korea, update of maintenance of managing radioactive materials in water is being made mainly by Ministry of Environment. In this study, we analysed current state of monitoring system modification in Japan, the country directly involved and neighboring country. According to the result, Japan modified the legislations first. Then Ministry of Education, Culture, Sports, Science and Technology (MEXT) provides theoretical background of radiological monitoring. And Ministry of the Environment actually watches state of water pollution in public waters and underground water. Finally related agencies like local government are monitoring current state of radioactive contamination in water environment. By region, local monitoring stations share the investigation of the whole country. Also, additional monitoring is running around nuclear facilities. After Fukushima disaster, monitoring for area near Fukushima is added. Among the reference levels, management target value of drinking water and tap water is 10 Bq/kg, and those of public water and underground water are 1 Bq/L. Measuring intervals varied from every hour to once a year, regularly or irregularly depending on the investigation. The main measuring items are air dose rate, gross ${\alpha}$, gross ${\beta}$, ${\gamma}$ radionuclide, Cs-134, Cs-137, Sr-89, Sr-90, I-131, and so on. In comparison, regulations about general public water in Korea need to be modified, while those about area near nuclear facility and drinking water are organized well. In future, therefore, domestic system would be expected to be modified with making reference to the guidelines like WHO's one. As good case of applying international guideline to domestic environment, Japanese system could be a reference when general standard of radioactivity in public water is made in Korea.

Effects of Gamma Irradiation and Ethylene Oxide Fumigation on the Quality of Dried Marine Products (Shrimp, Anchovy) (방사선 조사가 Ethylene oxide 처리가 건조수산가공품(건새우, 건멸치)의 품질에 미치는 영향)

  • 조한옥;변명우;권중호;이재원
    • Journal of Food Hygiene and Safety
    • /
    • v.2 no.1
    • /
    • pp.21-27
    • /
    • 1987
  • ABS1'RACT-Comparative effects of gamma irradiation and ethylene oxide treatment on the sterilization, and physicochemical and sensory quality of dried marine products(shrimp, anchovy) were investigated. Population of mesophilic total bacteria, aerobic spores and tolerant bacteria of samples were $10^{3}-10^{7}/g,\;10^{7}\;to \;10^{4}/g\;and\;10^{2}\;to\;10^{6}/g$, respectively. Coliforms and molds were found only in dried shrimp as $10^{2}/g$. Mesophilic total bacteria, aerobic spores and acid tolerant bacteria were reduced by over 2 to 4 log cycles with irradiation of 5 to 7 kGy and they were completely sterilized by irradiation dose of 7 to 10 kGy. $D_{10}$ value of mesophilic total bacteria of samples ranged from 1.53 to 2.73 kGy. Coliforms and molds were sterilized at 5 to 7 kGy irradiation but ethylene oxide treatment proved insufficient to eliminate the microorgainsms. An optimum dose of irradiation was less detrimental than ethylene oxide treatment to phpicochemical properties of the samples, such as the pH, TBA value, TMA-N, amino acids, minerals and color difference. Sensory quality after three months of storage showed that the overall acceptability of irradiated sample was higher than that of the non treated control as well as ethylene oxide treated samples.amples.

  • PDF

Effect of Combination of Chitosan Coating and Gamma Irradiation on the Foodborne Pathogen Reduction and Nutritional Properties of Chicken Egg (키토산 코팅 및 감마선 조사에 의한 계란에 오염된 위해 미생물 제어 및 영양학적 특성 평가)

  • Kim, Hyun-Joo;Yun, Hye-Jeong;Jung, Samooel;Jung, Yeon-Kuk;Ham, Jun-Sang;Jin, Shil;Jo, Cheorun
    • Korean Journal of Poultry Science
    • /
    • v.37 no.1
    • /
    • pp.35-41
    • /
    • 2010
  • The effect of combination of chitosan coating and gamma irradiation on Escherichia coli inactivation and nutritional properties of shell egg was investigated. The E. coli inoculated on shell egg was not detected by 2 kGy of gamma irradiation at day 0 and/or chitosan coating (1%, pH 5.0) after 3 days of storage. There was no E. coli detected thereafter. In the contents of moisture, crude fat, crude protein, ash, retinol, phospholipid, and minerals, no difference was found by treatment combination. However, the contents of cholesterol and carotenoids were reduced by irradiation of 2 kGy (P<0.05). Results suggest that the combination of gamma irradiation (2 kGy) and chitosan coating (1%) can be a good method to improve the safety and prolonged shelf-life of egg because of effective pathogen inactivation without significant adverse changes in nutritional quality.

Microbiological and Genotoxicological Safety of Gamma-Irradiated Chicken (감마선조사 닭고기의 미생물학적 및 유전독성학적 안전성 평가)

  • 곽희진;정차권;강일준
    • Korean journal of food and cookery science
    • /
    • v.17 no.6
    • /
    • pp.617-624
    • /
    • 2001
  • Gamma irradiation (1-10 kGy) was applied to chicken for the evaluation of their microbiological safety and possible genotoxicity. In 3 kGy-irradiated sample, the growth of psychrophile was inhibited about 1.5 log cycles and no cells were recovered in total microbial counts. All kinds of contaminated microorganism were sterilized by 7 kGy-irradiation. Also, irradiation followed by freeze-storage at the same time was very effective in inhibiting bacterial growth. The genotoxicity of 10 kGy-irradiated chicken was evaluated by Salmonella Typhimurium reversion assay and in vivo micronucleus assay using mouse bone marrow cells. The results were negative in the bacterial reversion assay with S. Typhimurium TA98, TA100, TA1535, and TA1539. Clastogenic effects were not shown in vivo mouse micronucleus assay at 10 kGy-dose tested.

  • PDF

Thoracic Actinomycosis - A Case Report - (흉부 방선균증-1례 보고-)

  • 박찬범;최시영;조덕곤;문석환;조규도;조건현;왕영필;이선희
    • Journal of Chest Surgery
    • /
    • v.35 no.12
    • /
    • pp.914-916
    • /
    • 2002
  • Actinomycosis of the lung is a chronic, suppurative granulomatous infection which is caused by Actinomyces israelii. It is believed to enter the thorax by way of the bronchial tree, by aspiration of contaminated aerosol particles in the upper digestive tract. Symptoms of chronic cough, sputum, hemoptysis, low grade fever, chest pain, and weight loss are common. Chest X-ray shows mass like lesion, pulmonary infiltration, abscess, and tuberculosis like lesion, which makes differential diagnosis from lung cancer very difficult. Surgical intervention is needed for the diagnosis and treatment, and diagnosis of actinomycosis is achieved when histologic examination reveals sulfur granules containing filamentous organisms. Penicillin is the drug of choice. Two or three months of penicillin treatment is recommended to treat the oropharyngeal or dental abscess to avoid recurrences. We present a case of actinomycosis which is suspected to malignant with review of literatures.

Nonuniform Gain Correction Based on the Filtered Gain Map in Radiography Image Detectors (방사선 영상 디텍터에서 필터링된 이득지도를 사용한 불균일 이득 잡음의 보정)

  • Kim, Dong Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.4
    • /
    • pp.97-105
    • /
    • 2016
  • Radiography image detector produces digital images by collecting the charges from the incident x-ray photons and converting it to the voltage signals and then the digital signals. The fixed-pattern noise from the nonuinform amplifier gains in the employed multiple readout circuits. In order to correct the nonuniform gains, a gain-correction technique which is based on the gain map is conventionally used. Since the photon noise remains in the designed gain map, the noise contaminates the gain-corrected images. In this paper, experimental observations are conducted for filtering the remained noise in the gain map, and a filter optimization algorithm is proposed to efficiently remove the noise. For acquired x-ray images from detectors, the filtered gain maps are evaluated and it is shown that optimization algorithm can improve the filtering performance even for relatively strong fixed-pattern noises, which cannot be removed by a simple filter.