• Title/Summary/Keyword: 방사선동위원소

Search Result 571, Processing Time 0.028 seconds

A Calculation of Effective Dose Equivalent from Data of Environmental Monitoring around the Karlsruhe Nuclear Research Center (Karlsruhe 원자력연구소 주변의 환경방사능 측정자료로부터 실효선량당량계산)

  • Lee, Chang-Woo;Lee, Jeong-Ho;Wicke, A.
    • Journal of Radiation Protection and Research
    • /
    • v.15 no.2
    • /
    • pp.75-85
    • /
    • 1990
  • The dose calculations were carried out using environmental montoring data around Karlsruhe Nuclear Research Center(KfK). Ingestion of plant foods was the most important pathway, and the K-40 and Pb-210 natural radioisotopes in food were the most effective radiation source to man. The dose received from artificial nuclides were mostly emitted by gamma irradiation of Cs-134 and Cs-137 deposited on the ground. The effective dose equivalent in the KfK environment was far less than the dose equivalent limit recommended by ICRP.

  • PDF

Electronic Circuit System of a Portable Rl Gauge for Compaction Control (성토다짐용 휴대용 Rl 계기의 전자회로 시스템)

  • 김기준
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.4 no.2
    • /
    • pp.32-38
    • /
    • 1999
  • In this study, an objection is to develop a electronic circuit of a gauage using radioisotope for compaction control to be needed at public works The developed gauage makes use of radioisotope with the activity exempted from domestic atomic law and consists of measuring circuits for gamma-rays and thermal neutrons, a high voltage supply unit and a microprocessor. To obtain meaningful numbers of pulse counts, parallel five and tow circuits are provided for gamma-rays and thermal neutrons, respectively. Also, to minimize effects of natural environmental radiation and electrical noise, circuits are electrostatically shielded and pulses made by ripples are eliminated by taking frequency of high voltage supplied to the circuit and pulse height of ripples into consideration One-chip microprocessor is applied to process various counts, results are stored, Enough and meaningful numbers of pulses are counted with the prototype gauage for compaction control.

  • PDF

원자로 생산 방사성 핵종의 임상이용

  • 임상무
    • Nuclear Engineering and Technology
    • /
    • v.27 no.4
    • /
    • pp.635-643
    • /
    • 1995
  • 핵의학(nuclear medicine )이 란 방사성 및 안정 핵종의 동위원소표지 화합물을 인체에 투여하여, 관심장기의 형태 및 기능을 평가하여 해부학적 또는 생리학적 상태를 진단, 치료하는 의학의 전문 분야이다. 핵의학에 이용되던 방사성 핵종은 1960년대 까지만 해도 $^{131}$ I이 주였으나 1970년대 부터는 $^{99}$Mo -$^{99m}$ Tc 발생기와 $^{99m}$ TC으로 표지된 방사성의 약품이 활발히 이용되면서 $^{131}$ I을 대신하게 되었다. 원자로-생산핵종들의 특성은 중성자가 과잉이어 붕괴시 배타입자를 방출하는 점으로, 이것이 각종 질병의 치료에 이용되고 있다. 특히 각종 표시 화합물의 성질을 이용하여 원하는 부위에 방사선을 집중시킬 수 있음이 외부조사보다 유리한 점이다. 방사성핵종을 이용한 악성종양의 치료에 가장 성공적인 것은 분화된 갑상선 암환자에서 $^{131}$ I을 사용한 것이며, 갈색세포종 등에 $^{131}$ I-MIBG도 효과적이다. 악성종양의 골전이 치료에 베타선을 방출하는$^{32}$P, $^{186}$ Re, $^{153}$ Sm 등이 이용되었다. 종양의 동맥에 주입하여 세동맥이나 모세혈관에 걸리는 기름, 교진 또는 입자에 의한 치료에 $^{131}$ I-lipiodol, ethiodol, $^{32}$P 또는$^{90}$ Y흡사 ceramic resin 미소구 $^{166}$ Ho 유산중합체 미소구 등이 이용된다. $^{166}$ Ho, $^{198}$ Au, $^{32}$P, $^{90}$ Y, $^{169}$ Er, $^{186}$ Rc, $^{131}$ I, $^{211}$ At 등 의 방사성 핵종의 교질, 미소구 또는 단세포군 항체표지 형태로 직접 종양내 또는 공동이나 체강에 투여하는 치료법이 있다. 류마치스 관절염의 슬관절에 $^{165}$ Dy colloid를 주사하는 $^{166}$ Ho-MAA도 활발히 이용되고 있다.

  • PDF

Safety Evaluation of a Shipping Capsule for Special Form Radioisotope (특수형 방사성 동위원소 운반캡슐의 안전성 평가)

  • Lee, Ju-Chan;Seo, Ki-Seog;Ku, Jeong-Hoe;Bang, Kyoung-Sik;Han, Hyon-Soo;Park, Seong-Won
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.1
    • /
    • pp.35-43
    • /
    • 2001
  • All of sealing capsules to transport a special form radioactive material should be designed and fabricated in accordance with the design criteria prescribed in IAEA standards and domestic regulations. The objective of this study is to demonstrate the safety of a shipping capsule for $^{192}Ir$ special form radioisotope which produced in the HANARO. The safety tests were carried out for the impact, percussion, bending and heat test conditions. And leakage tests were carried out before and after the each test. Also, the safety analyses wert performed using computer codes in order to verify the test results. The capsule showed slight scratches and deformation, and maintained its structural and thermal integrities in all tests without any severe damage or melting. It also met the allowable limits of leakage rate after each test. Therefore, it has been verified that the capsule was designed and fabricated to meet all requirements for the special form.

  • PDF

Fabrication of Virtual Frisch-Grid CdZnTe ${\gamma}$-Ray Detector (가상 Frisch-그리드를 이용한 CdZnTe 감마선 소자 제작)

  • Park, Chansun;Kim, Pilsu;Cho, PyongKon;Choi, Jonghak;Kim, Jungmin;Kim, KiHyun
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.253-259
    • /
    • 2014
  • Large volume of $6{\times}6{\times}12mm^3$ CdZnTe ${\gamma}$-ray detector was fabricated with CdZnTe single crystals grown by Traveling Heater Method (THM) to evaluate the energy resolution of 662 keV in $^{137}Cs$. Hole tailing effect which originated from the large mobility difference in electron and hole degrade energy resolution of radiation detector and its effects become more severe for a large volume detectors. Generally, single carrier collection technique is very useful method to remove/minimize hole tailing effect and thereby improvement in energy resolution. Virtual Frisch-grid technique is also one of single charge collection method through weighting potential engineering and it is very simple and easily applicable one. In this paper, we characterized CZT detector grown by THM and evaluated the effectiveness of virtual Frisch-grid technique for a high energy gamma-ray detector. The proper position and width of virtual Frisch-grid was determined from electric field simulation using ANSYS Maxwell ver. 14.0. Energy resolution of 2.2% was achieved for the 662 keV ${\gamma}$-peak of $^{137}Cs$ with virtual Frisch-grid CdZnTe detector.

Studies on the Chromatin Isolated from the Organs of Animals Received Whole-body X-ray Irradiation (백서장기(白鼠臟器)에서의 Chromatin의 분리(分離)와 그 RNA 합성능(合成能)에 미치는 X-선전신조사(線全身照射)의 영향(影響)에 관(關)한 연구(硏究))

  • Han, Su-Nam
    • The Korean Journal of Nuclear Medicine
    • /
    • v.1 no.2
    • /
    • pp.27-34
    • /
    • 1967
  • 1. Within experimental chromatin, the total protein: DNA ratio did not vary in the same organs of control and irradiated rats. However, the amount of RNA and total protein associated with the DNA varied considerably among the different types of chromatin. In particular, the content of chromatin was the highest in the irradiated tissue, and the lowest in the chromatin control tissue. RNA and total protein ratio of chromatins from brain, liver, testis and spleen declined with experimental organs. 2. There was the same quantitative relationship between the amount of RNA and the amount histone-protein associated with DNA in each chromatin. 3. RNA:DNA ratio of chromatin showed a $1.5{\sim}2$ times increase in the irradiated organs except brain. However, RNA:DNA ratio was decreased in chromatin by irradiation. 4. Histone-protein:Residual protein ratio was greatly varied among the organs. However, the effect was not found by irradiation. 5. Priming activity of chromatins showed a higher value in testis and the activity was greater in organs with higher metabolic activity. 6. Inhibition of Actinomycin D observable in chromatin for testis, liver, spleen and brain declined without relationship between irradiated and non-irradiated conditions. Ammonium sulfate in DNA of chromatin from histone showed increased priming activity with dissociation by Electrostatics. It may give different effect of ammonium sulfate on stimulation by property of chromatins. 7. It is suggested that the results support a proposal that the higher sensitivity of radioactive in testis, spleen by irradiated showed a increase and decrease lower-sensitivity of radioactive from brain, liver than did priming activity under the radioactive conditions.

  • PDF

Study on the Measurement of Radon concentrations in soil samples using γ-spectrometer (γ-spectrometer를 이용한 토양시료의 라돈농도 측정법에 관한 연구)

  • Kang, Sunga;Lee, Sangsoo;Choi, Guirack;Lee, Junhaeng
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.31-36
    • /
    • 2013
  • The radioactive gas radon ($^{222}Rn$), which is generated from the decay process of uranium ($^{238}U$) originating from the soil of more than 85 percent higher the porosity of the soil, the soil can radiate out the possibility that many isotopes. In order to protect the human body from radon, above all, the development of accurate measurement techniques to formulate appropriate measures should be followed. This study Gamma-ray spectrometry using a high purity germanium (HPGe) detector, if you want to measure radon unstable the nature radiation of the background problems can be reduced, radium and radon daughter nuclides after radioactive equilibrium leads to Radon concentration was measured, the soil samples from the Gamma-ray emitting nuclides, and the energy spectrum is analyzed.

HUGE PLEOMORPHIC ADENOMA OF THE PAROTID GLAND: REPORT OF A CASE (이하선에 발생한 거대 다형성 선종)

  • Ryu, Sun-Youl;Ryu, Seung-Hee;Kim, Tae-Hee
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.3
    • /
    • pp.247-253
    • /
    • 2006
  • Pleomorphic adenoma of the parotid gland typically presents as painless, mobile mass of long duration, and originate in the superficial lobe but, more rarely these tumors may involve the deep lobe of the parotid gland. The average size of a parotid neoplasm is 2 to 4 cm. The effective treatment of parotid pleomorphic adenoma is surgical excision. The simple excision or enucleation resulted in recurrence rate of 45% in benign tumor. Therefore, the superficial parotidectomy with identification and preservation of the facial nerve is now the most widely accepted surgery. We report a case of the huge pleomorphic adenoma of the left parotid gland in a 67-year-old man who complained the large mass, measured about $10\times7\times5$cm-sized, in front of the left ear and on the mandibular ascending ramus. The diagnosis was confirmed by the clinical examination, computed tomographic scan, fine needle aspiration, and incisional biopsy. Superficial parotidectomy including the tumor and preservation of the facial nerve using the modified Blair approach was performed. And satisfactory results have been obtained cosmetically and functionally.

Follicle Cell Death during Ovarian Atresia in the Rat (Rat난소폐쇄에서의 난포의 사망기전)

  • ;;A. J. W. Hsueh
    • Korean Journal of Animal Reproduction
    • /
    • v.20 no.4
    • /
    • pp.385-393
    • /
    • 1997
  • 다세포 생물에서 몸의 효율적 생존을 위한 각 기관의 homeostasis는 세포 증식과 사망에 의해 조절된다. 따라서, apoptosis라 명명된 세포사망은 정교한 기전에 의한 능동적이고 자발적인 사망기전으로써 몸의 정상적 유지를 위한 필수적인 현상이다. 발생기 세포나 신경세포 또는 흉선세포 분화 동안 과다한 세포의 제거가 apoptosis의 대표적인 예이며, 각종 호르몬에 의해 그 기능이 조절되는 난소세포에서도 apoptosis가 활발히 일어난다. Rat난소에는 태어날 때 수십 만개의 난포를 지니고 있는데, 이 중 단지 1%만이 배란에 사용되어질 뿐이고 나머지는 모두 사망하게 된다. 이러한 난포사망은 난소의 적절한 세포 수를 유지하기 위한 필수적 과정이며, 인위적으로 apoptosis를 억제하는 유전자인 bcl-2를 과다 발현시키면 난소암이 발생하는 연구결과가 이를 입증해주고 있다. 이처럼 중요한 난포 사망기전은 apoptosis라는 개념이 정립되면서 최근 들어 점차 그 연구가 활발해지고 있다. Apoptosis의 특징 중 뚜렷한 점은 DNA가 일정한 간격으로(180∼200 bp)잘려지는 DNA fragmentation현상으로, 이를 이용하여 DNA3'-end 부위에 방사선동위원소를 label한 후 이를 전기영동으로 분리하면 apoptosis를 손쉽게 측정할 수 있다. 난소의 기능은 시상하부호르몬인 LH와 FSH 뿐만 아니라 난소에서 분비되는 각종 난소국부호르몬들에 의해 조절된다. 특정한 발육단계의 난포는 특정한 호르몬에 의해 그 기능을 조절 받는데, 이러한 난소기능 조절기작은 매우 복잡한 경로를 지니고 있다. 이러한 복잡한 기작으로 인해 초기 연구에서첨 생체 내에서 밝히려는 연구 시도는 어려움에 부딪치게 되었다. 생체내 실험은 난소가 다양한 발육단계의 난포를 동시에 지니고 있어 특정한 발육단계의 난포 사망기전을 연구하기 어렵다. 또한 난포는 생체 내에서 다양한 호르몬을 동시에 분비하기 때문에 특정한 난소국부호르몬이 사망기전에 미치는 영향을 조사하기 힘든 점이 있다. 최근 들어 난포체외배양이 다양하게 개발되면서, 이러한 어려운 점을 극복할 수 있게 되었다. 본 논문은 각 발육단계의 난포를 절단해 체외배양하면서, apoptosis DNA 절단 현상을 이용하여 각종 난소국부 호르몬들이 난포발육단계별로 사망기전에 미치는 영향을 요약해 보였다. 난포는 발육하면서 점차 복잡한 호르몬 경로를 생존을 위해 필요로 한다. Prevulatory난포생존에 필요한 난소국부호르몬들은 early antral 단계의 난포에서는 그 미치는 영향이 감소되다가 preantral단계의 난포에서는 영향을 전혀 미치지 못했다. 단지 예외는 cGMP처리로써, 세포내 cGMP수준을 일정하게 유지시켜주는 것이 난포발육단계에 무관하게 생존에 중요한 인자로, 장래 연구는 난포 세포내의 cGMP수준을 조절하는 기작을 규명하는데 있을 것이다.

  • PDF

A Study on the Penetration of Dexamethasone into Oral Mucosa with the Use of Iontophoresis (이온영동법에 의한 Dexamethasone의 구강점막에의 침투에 관한 연구)

  • Sung-Woo Lee;Young-Ku Kim;Hong-Seop Kho
    • Journal of Oral Medicine and Pain
    • /
    • v.16 no.1
    • /
    • pp.9-23
    • /
    • 1991
  • 이온 영동법은 전기력의 도움으로 이온화된 물질의 신체조직내 침투를 증가시키는 술식으로서 전신적 부작용은 줄어드는 반면, 국소부위의 약물농도를 증가시킬 수 있다는 장점 때문에 효과적인 국소요법으로 인정받고 있다. 치의학 분야에서는 과민상아질의 치료를 위해 불소 이온영동법이 빈번히 이용되어져 왔으며, 국소마취제나 항바이러스 제재의 도포시에도이용되었다.또,이온 영동법에 의한 스테로이드 투여로 피부나 구강점막의 염증성 질환의 효과적 치료를 보고한 많은 문헌이 있으나, 이온영동법에 의한 스테로이드의 구강점막에의 침투량이나 분포에 관해서는 거의 소개된 바가 없는 실정이다. 본 연구는 방사선 동위원소가 부착된 dexamethasone을 이온영동법을 이용하여 가토의 협점막에 침투시킨후 자기방사선 술식에 의해 그 침투량과 분포를 대조군과 비교 평가하였으며 다음과 같은 결과를 얻었다. 1. 이온영동법은 단순 국소도포에 비해 dexamethasone과 0.1M 인산소다 완충용액의 혼합액(dexamethasone in 0.1M sodium phosphate buffer solution)의 가토 협점막 침투량을 증가시켰으며, 양극을 사용하였을 때 더 효과적이었다. 2. Dexamethasone과 0.1M 인산소다 완충용액의 혼합액 투여 4시가, 24시간후 까지도 양극 잉온영동법이 효과적이었으며 은입자의 감소는 투여 4시간부터 24시간 후 사이에 주로 일어났다. 3. 인산소다 완충용액의 첨가는 양극 및 음극에 의한 이온영동법 모두에 효과적이었으며, 양극에 가장 효과적이었고 단순도포군에는 영향을 미치지 않았다. 4. 이온영동법에 의한 스테로이드 투여는 피부뿐만 아니라구강점막 염증성 병소의 효과적 치료술식으로 여거질 수 있다. 시와 maximal clenching시 사이의 치아 접촉시간에서도 유의한 상관관계를 보였다.

  • PDF